TITLE 4. THE PHILADELPHIA BUILDING CONSTRUCTION AND OCCUPANCY CODE [A-204 Deleted.] Article B-1.0 Adoption of the “2021 International Building Code” Article EB-1.0 Adoption of the "2021 International Existing Building Code" Article EC-1.0 Adoption of the "2021 International Energy Conservation Code" Article F-1.0 Adoption of the "2018 International Fire Code", with additions, deletions and amendments Article G-1.0 Adoption of the "2021 International Fuel Gas Code" Article M-1.0 Adoption of the "2021 International Mechanical Code" Article P-1.0 Adoption of the "2018 International Plumbing Code" Article PC-1.0 Adoption of the "2021 International Code Council (ICC) Performance Code for Buildings and Facilities" Part 1 – Scope and Application Part 2 – Administration and Enforcement Article R-1.0 Adoption of the "2021 International Residential Code" CHAPTER 4-100.0. LISTING OF SUBCODES § 4-101.0 Listing of Subcodes. This Title shall consist of the following subcodes: 1. Subcode "A" (The Philadelphia Administrative Code); 2. Subcode "B" (The Philadelphia Building Code); 3. Subcode "E" (The Philadelphia Electrical Code); 4. Subcode "EB" (The Philadelphia Existing Building Code); 5. Subcode "EC" (The Philadelphia Energy Conservation Code); 6. Subcode "F" (The Philadelphia Fire Code); 7. Subcode "G" (The Philadelphia Fuel Gas Code); 8. Subcode "M" (The Philadelphia Mechanical Code); 9. Subcode "P" (The Philadelphia Plumbing Code); 10. Subcode "PC" (The Philadelphia Performance Code for Buildings and Facilities); 11. Subcode "PM" (The Philadelphia Property Maintenance Code); 12. Subcode "R" (The Philadelphia Residential Code). CHAPTER 4-200.0. TEXT OF SUBCODES SUBCODE "A" (THE PHILADELPHIA ADMINISTRATIVE CODE) [History: Added, Bill No. 960591-A (approved March 26, 1997). Bill No. 960591-A added this Subcode "A" and repealed in its entirety previous Title 4, which was based on 1991 Ordinances, p. 188, as amended. All Section numbers were amended by Bill No. 030780 (approved December 31, 2003).] CHAPTER 1 GENERAL [History: This Chapter includes certain material inadvertently omitted in the enrolled bill (Bill No. 960591-A). The omissions were subsequently corrected by Bill No. 980795 (approved January 5, 1999).] SECTION A-101 PURPOSE A-101.1 Title: These provisions shall be known as the Philadelphia Administrative Code, shall be cited as such, and will be referred to herein as "this code". A-101.2 Scope: The provisions of this code shall serve as the administrative, enforcement and appeals regulations for the technical codes which regulate the site, construction, alteration, addition, repair, abatement, removal, demolition, location, occupancy and maintenance of all buildings, structures and building service equipment within the City of Philadelphia. A-101.3 Intent: This code shall be construed to secure its expressed intent which is to provide for the clear and consistent administration and enforcement of the technical codes adopted by the City of Philadelphia. The term "technical codes" shall mean the Building Code, Electrical Code, Energy Conservation Code, Existing Building Code, Fire Code, Fuel Gas Code, Mechanical Code, Performance Code for Buildings and Facilities, Plumbing Code, Property Maintenance Code and Residential Code (Subcodes "B", "E", "EC", "EB", "F", "G", "M", "PC", "P", "PM" and "R", respectively of this Title), and the Zoning Code (Title 14). This code incorporates, and amends where authorized, the administrative provisions of the Pennsylvania Uniform Construction Code Act (UCC), adopted by the City of Philadelphia by ordinance on June 21, 2004 for the regulation of construction through the technical codes. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-102 APPLICABILITY A-102.1 General: The provisions of this code shall apply to matters of administration common to the technical codes as set forth in Section A-101.0. Administrative provisions which are unique to one of the technical codes will be set forth in the administrative provisions of such code. Terms used in this code shall be as defined by the technical codes unless defined herein. The codes listed in Section A-101.3 (other than the Zoning Code) and referenced elsewhere in this code and the other technical codes comprise the Philadelphia Building Construction and Occupancy Code and shall be applicable as stated in each of the codes. Provisions in the appendices of the International codes shall not apply unless specifically adopted in the administrative provisions of the adopted code. The Building Construction and Occupancy Code does not apply to: 1. The use, construction or alteration of any building owned and operated by the federal government pursuant to the Public Building, Property and Works Law, 40 U.S.C. § 3101. 2. Pursuant to the UCC, an agricultural building that is a structure used to store farm implements, hay, feed, grain or other agricultural or horticultural products or to house poultry, livestock or other farm animals, which is subject to the Property Maintenance Code, the Zoning Code and the Fire Code. The exemption does not include habitable space or spaces in which agricultural products are processed, treated or packaged, or any place of occupancy by the general public. 3. Installation of tubing, piping, propane gas burning appliances, equipment or fixtures related to liquefied petroleum gas pursuant to the Propane and Liquefied Petroleum Gas Act, Act 61 of 2002, P.L. 421 (35 P.S. §§ 1329.1 – 1329.19). 4. Construction of individual sewage disposal systems pursuant to 25 Pa. Code, Chapter 73 (relating to onlot sewage treatment facilities) as regulated by the Department of Public Health. 5. With respect to electrical provisions of the code only, to a dwelling unit utilized by a member of a recognized religious sect if a code administrator grants an exemption under Section 901(b) of the UCC. 6. Pursuant to the UCC, the construction of structures which are: a. Erected for the purpose of participation in a fair, flea market, arts and crafts festival or other public celebration; b. Less than 1,600 square feet in size; c. Erected for a period of less than 30 days; and d. Not a swimming pool or hot tub. Such structures are subject to the Property Maintenance Code, the Zoning Code and the Fire Code. 7. Pursuant to the UCC, construction of a pole barn that is constructed on agricultural fairgrounds and is used solely for agricultural purposes and animal display. Such structures are subject to the Property Maintenance Code, the Zoning Code and the Fire Code. If an exempted pole barn has electrical service, a permit and inspections to determine compliance with the electrical provisions of the code are required. 8. Pursuant to the UCC, the installation and maintenance of ski lifts, inclined passenger lifts and related devices, elevators, escalators, conveying systems and related equipment as defined in the Building Code, with the exception of the accessibility requirements of the Building Code. Such devices and systems shall be regulated by the Pennsylvania Department of Labor and Industry. 9. Pursuant to the UCC, the construction or alteration of structures used for the direct, seasonal sale of agricultural commodities where such structures are: a. open on at least twenty-five percent (25%) of the perimeter of the structure when in operation. b. operated by a producer whose products make up not less than fifty percent (50%) of the agricultural commodities being sold; c. if not located on the producer's property, erected for less than 180 days of a calendar year; d. comprised of an area of not more than 1,000 square feet; e. used to load, unload or sort livestock at livestock auction facilities; and f. limited to one structure per parcel of land. Such structures are subject to the Property Maintenance Code, the Zoning Code and the Fire Code. A-102.2 Conflicting provisions: Whenever conflicting provisions or requirements occur within or between this code, the technical codes and any other applicable codes or laws, the most restrictive shall govern. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. A-102.3 Referenced codes and standards: The codes and standards referenced in any of the technical codes shall be considered part of the requirements of such code to the prescribed extent of each such reference. Where differences occur between provisions of a technical code and the referenced codes and standards, the provisions of the originating code shall apply. The department is authorized by regulation to update the edition of standards referenced by the technical codes as necessary to maintain current technical provisions. Such regulations shall be subject to the local amendment requirements of the UCC. Exception: Where enforcement of a code provision would violate the conditions of the listing of equipment or an appliance, the conditions of the listing and manufacturer's instructions shall apply. A-102.3.1 Referenced codes. Where this code or the technical codes reference the Administrative Code, International Building Code, ICC Electrical Code, International Energy Conservation Code, International Existing Building Code, International Fire Code, International Fuel Gas Code, International Mechanical Code, International Performance Code for Buildings and Facilities, International Plumbing Code, International Property Maintenance Code, International Residential Code or Zoning Code, it shall mean the City of Philadelphia Code of such title listed in the "Referenced Standards" Chapter of the referencing code and currently in effect unless specifically stated otherwise. A-102.3.2 Referenced standards. The standards referenced in this code or the technical codes shall be those that are listed in the "Referenced Standards" Chapter of the referencing code. A-102.4 Authority: Nothing in this code or in any of the technical codes shall be construed as conferring or attempting to confer upon any officer, department, board or commission of the City, the power of eminent domain. All actions by any officer, department, board or commission pursuant to this code or any of the technical codes shall be deemed to be in the exercise of the police power. The provisions of this code and the technical codes shall not be deemed to nullify any applicable provisions of other local, state or federal laws. A-102.5 Subjects not regulated by this code. Where no applicable standards or requirements are set forth in the technical codes, or are contained within other laws, codes, regulations or ordinances, compliance with applicable nationally recognized standards, as approved, shall be deemed as prima facie evidence of compliance with the intent of the technical code. Nothing herein shall derogate from the authority of the code official to determine compliance with codes or standards for those activities or installations within the code official's jurisdiction or responsibility. Requirements necessary for the strength, stability or proper operation of an existing or proposed building or mechanical system, or for the public safety, health and general welfare, not specifically covered by the technical codes or applicable standards, shall be determined by the code official. A-102.6 Existing structures. The legal occupancy of any structure existing on the date of adoption of the Building Construction and Occupancy Code, or any subcode thereof, shall be permitted to continue without change, except as is specifically covered in such code, the Philadelphia Property Maintenance Code or Philadelphia Fire Code, or as is deemed necessary by the code official for the general safety and welfare of the occupants and the public. This Section (A-102.6) is subject to the following provisions of the UCC: 1. A building that was built before April 27, 1927 is deemed to be legally occupied until the owner proposes to renovate, add an addition, alter or change the occupancy of the building. The renovation, addition, alteration or change in occupancy must comply with the UCC. 2. For all existing structures built on or after April 27, 1927, the code official is authorized to issue a certificate of occupancy if the building meets the requirements of the latest adopted version of the "International Existing Building Code". The code official may deny the issuance of a certificate of occupancy if the official deems that a building is unsafe because of inadequate means of egress, inadequate lighting and ventilation, fire hazards or other dangers to human life or to public welfare. A-102.6.1 Existing installations. Except as otherwise specifically provided for in the technical codes, a provision in the technical codes shall not require the removal, alteration or abandonment of, nor prevent the continued utilization and maintenance of the following systems and equipment lawfully in existence at the time of adoption of this code and the technical codes. 1. Building envelope 2. Electrical systems and equipment 3. Fuel gas installations 4. Mechanical systems 5. Plumbing systems 6. Service water-heating systems A-102.6.2 Buildings not previously occupied. A building or portion of a building that has not been previously occupied or used for its intended purpose in accordance with the laws in existence at the time of its completion shall comply with the Building or Residential Code as applicable for new construction or with any current permit for such occupancy. A-102.7 Maintenance. Buildings and parts thereof shall be maintained in a safe and sanitary condition. Fuel gas installations; mechanical systems; plumbing systems and electrical systems, equipment, materials and appurtenances and parts thereof, shall be maintained in proper operating condition in accordance with the original design and in a safe, hazard-free condition. All existing devices and safeguards that are required by the technical codes shall be maintained in existing buildings. The owner or the owner's designated agent shall be responsible for the maintenance of the building. To determine compliance with this subsection, the code official shall have the authority to require a building to be reinspected. Except where specifically permitted by the Building Construction and Occupancy Code, the code shall not provide the basis for removal or abrogation of fire protection and safety systems and devices in existing buildings. Exception: This Section shall not prohibit the removal of fire protection systems or equipment where such removal is authorized by an approved permit and construction documents for alterations and/or a change in occupancy classification, and the fire protection systems or equipment are not required by the current Building and Fire Codes. A-102.8 Additions, alterations and repairs to structures. Additions, alterations and repairs to an existing building or structure, or portion thereof shall conform to the requirements for new construction per the currently adopted technical codes. Additions, alterations and repairs shall not cause an existing building or structure to become unsafe, hazardous or overloaded. Exception: At the option of the applicant or registered design professional in responsible charge, additions, alterations and repairs shall be permitted to comply with the applicable provisions of the Philadelphia Existing Building Code. A-102.8.1 Additions, alterations and repairs to systems. Additions, alterations, renovations and repairs to the following systems and installations shall conform to the requirements for new systems and installations without requiring any portion of the existing systems and installations to comply with all of the requirements of the applicable technical codes. Additions, alterations and repairs shall not cause an existing system or installation to become unsafe, hazardous or overloaded. 1. Electrical installations 2. Fuel gas installations 3. Mechanical systems 4. Plumbing systems 5. Service water-heating systems Minor additions, alterations, renovations and repairs to existing systems or installations shall meet the provisions for new construction, unless such work is done in the same manner and arrangement as was done in the existing system, is not hazardous and is approved. A-102.9 Change of occupancy. It shall be unlawful to make a change of occupancy, as specifically defined in this code and the technical codes, of any building unless such building is made to comply with the requirements of this code and the applicable technical codes for such new occupancy. A-102.10 Historic buildings. The Building Construction and Occupancy Code shall be fully applicable to buildings designated as historic pursuant to Chapter 14-1000 or listed in the National Register of Historic Places; provided, however, that variances shall be available pursuant to Section A-802.2. A-102.11 Moved structures. Structures moved into or within the City of Philadelphia shall comply with the requirements of the Building Code for new structures. Electrical systems and equipment, fuel gas installations, and mechanical systems that are a part of buildings or structures moved into or within the City of Philadelphia shall comply with the provisions of the Electrical Code, Fuel Gas Code and Mechanical Code respectively for new installations. This subsection shall not apply to structures regulated under the Industrialized Housing Act, Act 70 of 1972, P.L. 286 (35 P.S. §§ 1651.1 – 1651.12) or the Manufactured Housing Construction and Safety Standards Authorization Act, Act 192 of 1982, P.L. 676 (35 P.S. §§ 1656.1 – 1656.9). A-102.12 Manufactured and industrialized housing and industrialized commercial buildings. Manufactured housing pursuant to the Manufactured Housing Construction and Safety Standards Authorization Act (35 P.S. §§ 1656.1 – 1656.9) and industrialized housing and industrialized commercial buildings pursuant to the Industrialized Housing Act (35 P.S. §§ 1651.1 – 1651.12) respectively shall be governed by Sections A-102.12.1 through A-102.12.2.2. A-102.12.1 Manufactured housing. Manufactured housing shall comply with the provisions of Sections A-102.12.1.1 through A-102.12.1.3. A-102.12.1.1 Exemption. Except as provided in Section A-102.12.1.2, the Building Construction and Occupancy Code does not apply to manufactured housing assembled by and shipped from the manufacturer and which bears a label which certifies that it conforms to Federal construction and safety standards adopted under the Housing and Community Development Act of 1974 (42 U.S.C. §§ 5401 – 5426). A-102.12.1.2 Site construction. Relevant provisions of the Philadelphia Residential Code shall apply to the following: 1. Site preparation 2. Foundation construction 3. Connection to utilities A-102.12.1.3 Code application. The Building Construction and Occupancy Code applies to the following: 1. Alteration or repair to the unit that is not within the scope of 24 C.F.R. 3280.1 – 3280.904 (relating to manufactured home construction and safety standards) and the manufacturer's installation instructions after assembly and shipment by the manufacturer. 2. Additions to the unit after delivery to the site. 3. Construction, alteration, repair or change of occupancy if the manufactured housing is resold to a subsequent purchaser. 4. Construction, alteration, repair or change of occupancy if the original purchaser relocates the manufactured housing. A-102.12.2 Industrialized housing and industrialized commercial buildings. Industrialized housing and industrialized commercial buildings shall comply with the provisions of Sections A-102.12.2.1 through A-102.12.2.2. A-102.12.2.1 Exemption. Except as provided in Section A-102.12.2.2, the Building Construction and Occupancy Code does not apply to industrialized housing and industrialized commercial buildings assembled by and shipped from the manufacturer. A-102.12.2.2 Code application. The Building Construction and Occupancy Code applies to the following: 1. Site preparation 2. Foundation construction 3. Utilities connection 4. Installation 5. Construction, alteration or repair to the industrialized housing unit after installation. 6. Change of occupancy classification if the industrialized housing or industrialized commercial building is resold to a subsequent purchaser or relocated. A-102.13 Swimming pools. Swimming pools shall be governed by the provisions of Sections A-102.13.1 through A-102.13.3. A-102.13.1 Requirements. Swimming pools, hot tubs and spas that are accessory to residential buildings shall comply with all of the following: 1. Philadelphia Residential Code. 2. Philadelphia Building Code provisions related to glazing in walls and fences enclosing indoor and outdoor swimming pools, hot tubs and spas. A-102.13.2 Swimming pools not accessory to dwellings. Pursuant to the UCC, swimming pools that are not accessory to one- or two-family dwellings shall comply with this Section (A-102.13), the "American National Standards for Public Pools" issued by ANSI and NSPI (ANSI/NSPI-1 2003) and the Public Bathing Law (35 P.S. §§ 672 – 680d). A-102.13.3 Hot tubs and spas. Pursuant to the UCC, hot tubs and spas that are not accessory to one- or two- family dwellings shall comply with this Section (A-102.13) and the "American National Standard for Public Spas" issued by ANSI and NSPI (ANSI/NSPI-2 1999). A-102.14 State-owned buildings. The provisions of this Title 4 shall apply to all State-owned buildings; provided, however, that pursuant to the UCC, the Commonwealth Department of Labor and Industry will conduct plan and specification review of permit applications, issue permits and perform inspections to ensure compliance with the UCC. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012.] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 120774-A (approved January 14, 2013); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-103 VALIDITY A-103.1 Partial invalidity: In the event any part or provision of this code or the technical codes is held to be illegal or void, this shall not have the effect of making void or illegal any of the other parts or provisions thereof, which are determined to be legal; and it shall be presumed that this code and the technical codes would have been passed without such illegal or invalid parts or provisions. A-103.2 Segregation of invalid provisions: Any invalid part of this code or the technical codes shall be separated from the remainder of such codes by the court holding such part invalid, and the remainder shall remain effective. A-103.3 Existing structures: The invalidity of any provision in any Section of this code or the technical codes as applied to existing structures shall not be held to affect the validity of such Section in its application to structures hereafter erected. A-103.4 Saving clause: The enactment of this code and/or any of the technical codes shall not affect violations of any ordinance, code or regulation existing prior to the effective date of this code or the technical codes. Any such violation shall be governed and shall continue to be punishable to the full extent of the law under the provisions of those ordinances, codes or regulations in effect at the time the violation was committed. Exception: The code official shall have the authority, upon proper evaluation, to not enforce a violation issued under any ordinance, code or regulation existing prior to the effective date of this code or the technical codes where such violation does not constitute a violation of this code and the current technical codes. A-103.5 Flood protection provisions. The degree of flood protection sought by the provisions of this code is considered reasonable for regulatory purposes and is based on accepted engineering methods of study. Larger floods may occur or flood heights may be increased by man-made or natural causes, such as ice jams and bridge openings restricted by debris. This code does not imply that areas outside any identified floodplain areas, or that land uses permitted within such areas will be free from flooding or flood damages. This code shall not create liability on the part of the City of Philadelphia or any officer or employee thereof for any flood damages that result from reliance on this code or any administrative decision lawfully made thereunder. [History: Added, Bill No. 180175 (approved June 6, 2018).] SECTION A-104 WORKMANSHIP A-104.1 General: All work which is performed either directly or indirectly for compliance with this code and all other technical codes and the mandates of the Department's bulletins, shall be conducted, installed and completed in a workmanlike and acceptable manner so as to secure the results intended by such codes. [History: Amended, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015). Enrolled bill read "...for compliance with the this code...."] SECTION A-105 RESPONSIBILITY A-105.1 Owners: The owner shall be responsible for the testing, maintenance and repair of structures and systems in accordance with the maintenance provisions of this code and the technical codes. A-105.2 Occupant responsibility: If an occupant of a structure creates conditions in violation of this code or the technical codes, by virtue of any improper use of the premises or by virtue of storage, handling and use of substances, materials, devices and appliances, the occupant shall be responsible for the abatement of said hazardous conditions. A-105.3 Contractor responsibility: All contractors, whether licensed by the Department or exempt from licensing under State law, shall be responsible for compliance with this code and the technical codes in the performance of their work. A-105.4 Transfer of responsibility: A contract between owner and operator, owner and contractor, operator and occupant, operator and contractor, occupant and contractor, or owner and occupant with regard to compliance with this code and the technical codes shall not relieve any party of direct responsibility under such codes. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Renumbered and amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-106 DEFINITIONS A-106.1 General. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code and the technical codes, have the meanings shown in this Section. AFFORDABLE HOUSING PROJECT: A proposal for the development of one or more residential units that requires obtaining a Zoning Permit and includes any of the following: 1. The Mixed Income Housing density bonus requirements as set forth in subsection 14-702(7). 2. The /MIN, Mixed Income Neighborhoods Overlay District requirements as set forth in Section 14-533 or the Affordable Housing Preservation Overlay as set forth in subsection 14-534(3). 3. The terms of a City, state, or federal financing program that requires affordable housing be constructed or preserved pursuant to a restrictive covenant or regulatory agreement, including but not limited to those found in subsection 7-202(1). 4. The requirements for redevelopment of surplus City property disposed by the Philadelphia Land Bank or Philadelphia Redevelopment Authority as affordable housing pursuant to subsection 16-404(2)(d)(.1)(.e). 5. An executed restrictive covenant or other restrictive instrument that is voluntarily executed and recorded with the City, is included in the Zoning Permit application, and provides that at least ten percent (10%) of residential dwelling units shall be designated and maintained as affordable for a term of not less than fifty (50) years, in accordance with the minimum affordability criteria set forth at subsection 14-702(7)(a)(.1) or subsection 14-702(7)(a)(.2) of the Code. AGRICULTURAL BUILDING: In accordance with the UCC, a structure utilized to store farm implements, hay, feed, grain or other agricultural or horticultural products or to house poultry, livestock or other farm animals, a milk house or a structure used to grow mushrooms, agricultural or horticultural products. The term includes a carriage house owned and used by members of a recognized religious sect for the purposes of housing horses and storing buggies. The term includes a structure that is less than 1,000 square feet in size which is utilized to process maple sap. The term shall not include habitable space or spaces in which agricultural products are processed, treated or packaged and shall not be construed to mean a place of occupancy by the general public. CHANGE OF OCCUPANCY: A change in the use of a building or a portion of a building that results in any of the following: 1. A change of occupancy classification. 2. A change from one group to another group within an occupancy classification. 3. Any change in use within a group for which there is a change in application of the requirements of this code and the technical codes. CODE OFFICIAL (OR BUILDING OFFICIAL): The Commissioner of Licenses and Inspections or his or her duly authorized representative charged with the administration and enforcement of such codes. Exception: In the Fire Code, the term "fire code official" or "code official" shall mean the Fire Commissioner and/or the Commissioner of Licenses and Inspections or their duly authorized representatives charged with the administration and enforcement of the code in accordance with practices established by the two departments. COMPETENT PERSON: An individual who is capable of identifying existing and predictable hazards at the job site or is knowledgeable of policies and practices that affect working conditions which are unsanitary, hazardous or dangerous to employees, and who has authority to take prompt corrective measures to eliminate them. DEPARTMENT: The Department of Licenses and Inspections unless otherwise specified. Exception: In the Fire Code, the term "Department" shall mean the Fire Department unless otherwise specified. HEALTH CARE FACILITY: Any of the following, regardless whether the facility is operated for profit, nonprofit or by an agency of the Commonwealth or local government: a general, chronic disease or other type of hospital, a home health care agency, a hospice or long-term care nursing facility, a cancer treatment center using radiation therapy on an ambulatory basis, an ambulatory surgical facility, a birth center, or any other health care facility licensed by the Commonwealth Department of Health as may be necessary due to emergence of new modes of health care; provided that the term "health care facility" shall not include an office used primarily for the private practice of a health care practitioner, a program which renders treatment or care for drug or alcohol abuse or dependence unless located within a health facility, a facility providing treatment solely on the basis of prayer or spiritual means, or a facility which is conducted by a religious organization for the purpose of providing health care services exclusively to clergymen or other persons in a religious profession who are members of a religious denomination. OSHA 10: The 10-hour program designed and approved by the United States Occupational, Safety and Health Administration ("OSHA") under its Outreach Training Program for Construction intended to train workers on the recognition, avoidance, abatement, and prevention of safety and health hazards in workplaces in general industry. OSHA 30: The 30-hour program designed and approved by the United States Occupational, Safety and Health Administration ("OSHA") under its Outreach Training Program for Construction for additional training of supervisors and workers with some safety responsibilities. PERMIT HOLDER: The person(s) or business entity who owns the parcel, building or structure and is responsible for such property. While a permit may be obtained by another person or entity, that person or entity must have approval of the owner and the permit must always be subject to the control of the owner. The permit holder may be a person or entity with written documentation of equitable ownership of that real property. The permit holder may designate an agent such as a contractor to be the permit holder. REGISTERED DESIGN PROFESSIONAL: A licensed architect, licensed engineer or other licensed design professional that holds a currently valid license to practice in Pennsylvania. RESIDENTIAL BUILDING: Detached one-family and two-family dwellings and multiple single-family dwellings, including their accessory structures, which are not more than three stories in height with a separate means of egress. STATE-OWNED BUILDING: Pursuant to the UCC, a building owned by or to be constructed for Commonwealth entities, including the General Assembly, the Unified Judicial System, the Pennsylvania Higher Education Assistance Agency, an executive agency, independent agency, and a State-affiliated entity or State-related institution. A Commonwealth authority or a Commonwealth entity shall be considered a "State-affiliated entity". The term includes the Pennsylvania Turnpike Commission, the Pennsylvania Housing Finance Agency, the Pennsylvania Municipal Retirement System, the Pennsylvania Infrastructure Investment Authority, the State Public School Building Authority, the Pennsylvania Higher Educational Facilities Authority and the State System of Higher Education. The term does not include any court or other officer or agency of the unified judicial system, the General Assembly and its officers and agencies, any State-related institution, political subdivision or any local, regional or metropolitan transportation authority. UCC: The Pennsylvania Uniform Construction Code Act, Act 45 of November 10, 1999, P.L. 491, as amended. [History: Added, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 250043 (became law September 11, 2025).] [History: Added, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015).] [History: Added, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015).] CHAPTER 2 ENFORCEMENT AUTHORITY SECTION A-201 GENERAL A-201.1 Administration: This code and the technical codes shall be administered and enforced by the department except: 1. The Fire Code which is administered and enforced mutually by the Fire Department and the department; and 2. As otherwise specified in this code or the technical codes. A-201.1.1 Reasonable accommodations. The Department is authorized to develop regulations governing requests for reasonable accommodations under the Fair Housing Act and the American Disabilities Act. [History: Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 130847-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-202 DUTIES AND POWERS OF THE CODE OFFICIAL A-202.1 General: The code official shall enforce all of the provisions of this code and the technical codes and shall refer any observation of worker safety violations to OSHA, and shall act on any question relative to the following items, except as otherwise specifically provided for by statutory requirements or as provided for in this code or the technical codes: 1. The mode or manner of construction and materials to be used in the erection, addition to, alteration, repair, removal and demolition of structures; 2. The location, occupancy and maintenance of structures; 3. The installation of service equipment; 4. The installation, alteration, repair, maintenance or operation of all mechanical, electrical and plumbing systems devices and equipment; and 5. The installation, alteration, repair, maintenance or operation of all fire protection systems, devices and equipment. A-202.1.1 Training: In addition to the training and certification requirements of the Pennsylvania Uniform Construction Code, the Department shall ensure that inspectors responsible for construction and demolition code enforcement receive training by OSHA on identifying worker safety issues. The Department shall make every attempt to develop and maintain a formal training program in conjunction with OSHA which meets or exceeds OSHA 30 training certification. Should OSHA fail to provide such training, the Department shall have such inspectors receive OSHA 30 training either through a private provider or through certified individuals within the Department. A-202.1.2 Code Official Training: The Department shall do the following to ensure adequate enforcement of this Title, to the extent permitted under the PA Construction Code Act and Uniform Construction Code. 1. Any code official assigned to enforce the construction provisions of this Title shall have completed OSHA administered training equivalent to the OSHA 30. 2. All code officials assigned to enforce the provisions of this Title shall complete at least 3 hours of annual continuing education training focused on construction, hazmat issues, fire prevention strategies, safety, and other related industry or legal updates as applicable to their duties. A-202.1.3 Code Official Qualifications: The Department shall maintain job descriptions and continuing education requirements to conform to the training and certification requirements of the UCC. A-202.1.4 Notification of Worker Safety Issues: The code official shall be responsible for notifying OSHA whenever any worker safety hazard is observed during the course of an inspection or site visit. The Department shall develop and maintain a formalized notification process with OSHA. A-202.2 Applications and permits: The department shall receive applications and issue permits for the following activities, inspect the premises for which such permits have been issued and enforce compliance with the provisions of this code and the technical codes: 1. Construction, alteration and demolition of structures; 2. Installation and alteration of mechanical, electrical and plumbing systems, devices and equipment; 3. Installation and alteration of fire protection systems, devices and equipment; and 4. Such other activities specified in this code or the technical codes. 5. Installation and alteration of all intelligence/ communication systems and services. A-202.3 Notices and orders: The code official shall issue all necessary notices or orders to ensure compliance with this code and the technical codes. A-202.4 Inspections: The code official shall make all of the required inspections, or shall have the authority to accept reports of inspection by approved agencies or individuals. All reports of such inspections shall be in a form established by the Department and certified by a responsible officer of such approved agency or by the responsible individual. The code official is authorized to engage such expert opinion as deemed necessary to report upon unusual technical issues that arise, subject to approval. A-202.5 Regulations: The department shall have authority as necessary in the interest of public health, safety and general welfare, to adopt and promulgate rules and regulations in accordance with Section 8-407 of the Philadelphia Home Rule Charter, to interpret and implement the provisions of this code and the technical codes to secure the intent thereof and to designate requirements applicable because of special conditions. Such regulations shall not have the effect of waiving structural, fire performance or fire safety requirements specifically provided for in the technical codes, and such regulations shall conform with accepted engineering practice involving public safety. A-202.6 Policies and procedures: The Department shall have the authority to render interpretations of this code and the technical codes and to adopt policies and procedures in order to clarify the application of the provisions. Such interpretations, policies and procedures shall be in compliance with the intent and purpose of the codes. A-202.7 Issuance Requirement: No license or permit required by any provision of Title 4 or by Sections 9-3901 et seq. shall be issued or renewed if the applicant is delinquent in the payment of any City or School District of Philadelphia taxes, charges, fees, rents or claims, or any penalties or fines which have been imposed as a result of a violation of any provision of this code or the technical codes, or any penalties or fines related to the property or the applicant's business for which the applicant is responsible, unless the applicant or owner has entered into an agreement to pay any such delinquency and is abiding by the terms of such agreement. No permit shall be issued if the owner of the property is delinquent in the payment of any City or School District of Philadelphia taxes, unless the owner has entered into an agreement to pay such delinquency and is abiding by the terms of such agreement. Compliance is required by the person or business required to obtain the license or permit. Proof of compliance shall be required prior to issuance of any license or permit. Exception: The requirements of this subsection (A-202.7) may be waived upon the code official's determination that the permit is required for work needed to properly maintain the property or correct a violation of The Philadelphia Code. Waiver under this provision shall not be available for building permits relating to new construction or additions to existing structures, or for zoning and use registration permits. A-202.8 Liability: The code official, member of the board of appeals or employee charged with the enforcement of this code, while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be civilly or criminally rendered liable personally and is hereby relieved from personal liability for any damage accruing to persons or property as a result of any act or by reason of an act or omission in the discharge of official duties. [History: Added, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 030780 (approved December 31, 2003).] [History: Added, Bill No. 050204 (approved June 15, 2005), effective December 31, 2005; Bill No. 051025 (approved January 24, 2006) changed the effective date to June 30, 2006. Amended, Bill No. 160138-A (approved June 28, 2016), effective January 1, 2017; amended, Bill No. 180175 (approved June 6, 2018).] [History: Enrolled bill read "...Section 9-3900 et. seq...."] [History: Added, Bill No. 180175 (approved June 6, 2018).] SECTION A-203 APPROVAL A-203.1 Approved materials and equipment: All materials, equipment and devices approved by the code official shall be constructed and installed in accordance with such approval. A-203.2 Used materials and equipment: The use of used materials, equipment, appliances and devices that meet the requirements of the technical codes for new materials is permitted. Used equipment and devices shall not be reused unless they have been reconditioned and placed in good and proper working condition, tested, and approved by the code official. A-203.3 Alternative materials and equipment: The provisions of the technical codes are not intended to prevent the installation of any material, design or method of construction not specifically prescribed by the technical codes, provided that any such alternative has been reviewed and approved. The commissioner is authorized to approve an alternative material, design or method of construction upon favorable recommendation of the Board of Building Standards (Board of Safety and Fire Prevention for matters exclusive to the Fire Code) when he or she finds that the proposed design is satisfactory and complies with the intent of the provisions of the technical codes, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in the technical codes in quality, strength, effectiveness, fire resistance, durability and safety. Exception: Alternative materials, designs or methods of construction not specifically prescribed by the technical codes may be permitted by the code official in accordance with Sections A-203.3.1 or A-203.3.2. A-203.3.1 Research and investigation: Sufficient technical data shall be submitted to substantiate the proposed installation of any material or assembly. If it is determined that the evidence submitted is satisfactory proof of performance for the proposed installation, the code official shall approve such alternative subject to the requirements of the technical codes. Whenever there is insufficient evidence of compliance with the provisions of the technical codes, or evidence that a material or method does not conform to the requirements of the technical codes, or in order to substantiate claims for alternative materials or methods, the code official shall have the authority to require tests as evidence of compliance to be made at no expense to the Department. Test methods shall be as specified in the technical codes or other recognized test standards. In the absence of recognized and accepted test methods, testing procedures shall be subject to the approval of the code official. Tests shall be performed by an approved agency. The cost of all tests, reports and investigations required under these provisions shall be paid by the applicant. A-203.3.2 Research reports: Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in the technical codes, shall consist of valid research reports from approved sources. A-203.3.2.1 Evaluation services. Materials, product, and methods of construction that were evaluated as meeting subcodes of the Building Construction and Occupancy Code by the ICC Evaluation Service, Inc. or an evaluation service accredited under ISO/IEC 17065:2012, “Conformity assessment – Requirements for bodies certifying products, processes and services” (or equivalent), are approved for use. The use shall conform with the evaluation. A-203.3.2.2 Testing laboratories. Materials, equipment and devices bearing the label or listed by a testing laboratory or quality assurance agency accredited by the International Accreditation Service, Inc. or another recognized agency under ISO/IEC 17025:2017, “General requirements for the competence of testing and calibration laboratories” (or equivalent), are approved for use if: 1. The testing laboratory or quality assurance agency deemed the material as meeting standards required by the Building Construction and Occupancy Code, and 2. The scope of accreditation is applicable to standards required by the Building Construction and Occupancy Code. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [SECTION A-204 DELETED] [History: Added, Bill No. 130847-A (approved February 19, 2014), effective within 18 months (August 19, 2015); deleted, Bill No. 180175 (approved June 6, 2018).] CHAPTER 3 PERMITS SECTION A-301 APPLICATION FOR PERMIT A-301.1 Permits required: An application shall be submitted to the department for the activities listed in Sections A-301.1.1 through A-301.1.6 and these activities shall not commence without a permit being issued in accordance with Section A-302.0. Where the scope of work includes demolition, moving or removal of a structure greater than one story or greater than 500 square feet, a separate application and permit for such work shall be required. Where the scope of work includes more than one lot, a separate permit shall be required for each lot. Exception: Permits shall not be required for the construction, alteration and use of those buildings, elements and systems not regulated by this code as detailed in Section A-102.1 of this code, including but not limited to the following: 1. Pursuant to the UCC, State-owned buildings. 2. Pursuant to the UCC, the installation, repair or replacement of a boiler or unfired pressure vessel regulated by the Boiler and Unfired Pressure Law (35 P. S. §§ 1331.1 – 1331.19) and Chapter 3 (relating to boilers and unfired pressure vessels) as administered by the Pennsylvania Department of Labor and Industry. 3. Federally owned and operated buildings. 4. Pursuant to the UCC, the installation, alteration or repair of generation, transmission, distribution, metering or other related equipment that is, by established right, under the ownership and control of public services agencies. A-301.1.1 Building permits: A building permit is required for the following activities: 1. Construction or erection of a structure. 2. Construction of an addition to a structure. 3. Altering, modifying, repairing, or improving a structure. 4. Demolishing, moving or removing a structure. 5. Making a change of occupancy as defined in Section A-106.1 of this code. 6. Installing, erecting, enlarging, removing, replacing, converting, repairing or altering any equipment which is regulated by the Building Code, Fuel Gas Code, Mechanical Code or Residential Code. This includes the installation of a boiler in a building with less than five (5) dwelling units. 7. Installing any trailer, regardless of the method of support, including support on wheels or blocks. The provisions of this Title shall apply to a trailer in the same manner as if the trailer were a site-built structure. 8. Site clearing, grubbing or earth disturbance of land area of 5,000 square feet or more. No building permit shall be issued unless an erosion control plan has been approved for the site pursuant to applicable state and local stormwater-management requirements. 9. Earth disturbance exceeding 1,400 square feet on slopes greater than fifteen percent (15%) within the Steep Slope Protection Area, as defined in subsection 14-704(2), or exceeding 500 square feet within the Wissahickon Watershed Overlay, as defined in Section 14-510, except on sites designated as Category 5 on the associated Impervious Coverage Map. 10. Construction in the right of way as required by Title 11 of The Philadelphia Code. The provisions of this Title 4 shall apply to the issuance of a building permit. No such permit shall be issued without the approval of the Streets Department. 11. Excavation exceeding a depth of five (5) feet below adjacent grade. Exception: This provision shall not apply to the following activities, unless otherwise required by regulation: 1. Digging, trenching, or boring performed for utilities or geotechnical exploration. 2. Excavation for accessory structures or appurtenances serving a one- or two-family dwelling, provided the work is located more than ten (10) feet from an existing building on an adjacent lot and is demonstrated to the Department to have no potential impact on any existing building. 3. Excavation for sign structures, provided the work is located more than ten (10) feet from an existing building and is demonstrated to the Department to have no potential impact on any existing building. 4. Minor work that is demonstrated to the Department to have no potential impact on any existing building. A-301.1.2 Fire permits: A permit or license is required for those operations, facilities, trades and hazardous materials specified in the Fire Code. A-301.1.3 Electrical permits: An electrical permit is required for the installation, alteration, replacement or repair of electrical and communication wiring and equipment within or on any structure or premises and for the alteration of any such existing installation. A-301.1.4 Plumbing permits: A plumbing permit is required for the installation, alteration, renewal, replacement and repair of plumbing. A-301.1.5 Zoning and use registration permits: A zoning permit is required for the construction, erection, removal, demolition, or change in exterior dimension of any structure. A use registration permit is required for every new use commenced on any land or in any structure except for use as a single-family dwelling. An application for an affordable housing project must document in the scope of work that the project satisfies the criteria to be considered as an affordable housing project as defined in Section A-106. Examples of such documentation include: 1. Written confirmation from the Department of Planning and Development that the project complies with any of Sections A-106.1.1 through A-106.1.4. 2. Written confirmation from a government financing agency that the project complies with Section A-106.1.3. 3. Written confirmation from a public land holding agency that the project complies with Section A-106.1.4. 4. Written proof of an independently recorded written instrument that complies with Section A-106.1.5. A-301.1.6 Emergency repairs: Where equipment replacements and repairs of systems and structures that require a permit must be performed in an emergency situation, the permit application shall be submitted within the next three business days to the Department. In such cases, the Department shall be notified of the emergency as soon as possible. A-301.2 Permits not required: Permits shall not be required for the activities listed in Sections A-301.2.1 through A-301.2.5 and the regulations promulgated pursuant thereto. Exemptions from permit requirements of this code or the technical codes shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of The Philadelphia Code. Exception: Permits are required in flood protection areas for any construction, reconstruction, modification, extension, expansion, or substantial improvement of structures; filling; dredging; mining; grading; paving; excavation; drilling operations; or storage of equipment or materials; land excavation; land clearing; land improvement; or any construction thereof. A-301.2.1 Building permits: A building permit shall not be required for the following activities. This subsection does not exempt any activity from any other applicable permit requirements under The Philadelphia Code, including Chapter 14-1000 relating to historic designations. 1. Ordinary repairs to restore to good or sound condition any part of an existing structure for the purpose of its maintenance. Such repairs shall not include the cutting away of any wall, partition or portion thereof, the removal or cutting of any structural beam or loadbearing support, or the removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements; nor shall ordinary repairs include addition to, alteration of, replacement or relocation of any standpipe, gas, or similar piping or mechanical or other work affecting public health or general safety. 2. Recreational trailers, vacant trailers parked on site and trailers used in conjunction with construction for storage and construction management facilities during the construction operations. 3. Non-masonry fences that do not exceed six feet high. 4. Masonry fence walls that do not exceed two feet high. 5. Retaining walls that do not exceed two feet in height measured from the lowest level of grade to the top of the wall where no surcharge is supported and that do not impound Class I, II or III-A liquids. 6. Pointing of masonry. 7. Water tanks supported directly on grade where the tank capacity does not exceed 5,000 gallons and the ratio of height to diameter or width does not exceed 2-to-1. 8. Painting, papering and similar wall and ceiling finishes that do not exceed 0.036 inches (0.9 mm) in thickness. 9. Paneling or gypsum wallboard installed over existing wall surfaces and ceiling material applied directly to existing ceilings in one- and two-family and Group U occupancies. 10. Insulation installed in one- and two-family and Group U occupancies without removal of wall or ceiling surfaces. 11. Traditional floor coverings such as wood, vinyl, linoleum, terrazzo and resilient floor coverings that are not comprised of fibers. 12. Carpeting and similar floor coverings that are not installed in exit access corridors, exit passageways or vertical exits. 13. Cabinets, counter tops and similar finishing work. 14. Movable cases, counters and partitions that are not over 5 feet 9 inches in height. 15. Temporary motion picture, television, and theater stage sets and scenery. 16. One-story detached structures accessory to one- and two-family occupancies, provided the floor area does not exceed 200 square feet (18.58 m2). 17. Prefabricated swimming pools accessory to one- and two-family occupancies where the pool is less than 24 inches deep, does not exceed 5,000 gallons and is installed entirely above ground. 18. Window awnings that are supported solely by, and do not project more than 54 inches from, the exterior wall of buildings containing one- and two-family or Group U occupancies. 19. Shade cloth structures constructed for nursery or agricultural purposes that do not include service systems. 20. Swings, playground equipment and structures limited to the use of a household pet, accessory to one- and two-family occupancies. 21. Sidewalks, driveways, patios, and similar concrete or other hard surface materials constructed on grade where they are not part of an accessible route. This exception includes decks of any material, accessory to one- and two-family occupancies where the deck is located not more than 12 inches above the ground surface below and is not over a story or basement. 22. Replacement of non-fire-resistance rated windows and doors in one- and two-family occupancies without structural change (no change in shape or size of existing openings). 23. Portable units including: ventilation equipment, heating appliances, cooling units, evaporative coolers, clothes drying appliances, fuel cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. 24. Steam, hot or chilled water piping within any heating or cooling equipment regulated by the Building Construction and Occupancy Code. 25. Replacement of any component part or assembly of an appliance or equipment that does not alter its original approval and does not render the appliance or equipment unsafe. 26. Self-contained refrigeration systems that contain 10 pounds (4.5 kg) or less of refrigerant, or that are actuated by motors of 1 horsepower (0.75 kW) or less. 27. Bridge structures for rail, vehicular and/or footway traffic only, that are within street or rail rights-of- way. 28. Replacement of exterior stairs, ramps, platform lifts, steps and landings accessory to one- and two- family occupancies provided that they do not exceed 6 feet in vertical height; do not encroach upon the public right- of-way; and the landing does not have a surface area greater than 36 square feet with no individual dimension greater than 6 feet. This exclusion does not provide for vertical enclosure of the covered element(s) except guards required by the Building Code. 29. Buildings and structures subject to the Pennsylvania Industrialized Housing Act, Act 70 of 1972, P.L. 286, or the Pennsylvania Manufactured Housing Construction and Safety Standards Authorization Act, Act 192 of 1982, P.L. 676. This permit exception is limited in accordance with the provisions of Section A-102.12 of this code. 30. The installation of tubing, piping, propane gas burning appliances, equipment or fixtures related to liquefied petroleum gas pursuant to the Propane and Liquefied Petroleum Gas Act, Act 61 of 2002, P.L. 421 (35 P.S. §§ 1329.1 – 1329.19), as regulated by the Pennsylvania Department of Labor and Industry. A-301.2.2 Fire permits and licenses: A permit or license shall not be required for the following operations: 1. Storage of those quantities of materials or conditions exempted by the applicable provisions of the Fire Code. 2. Cutting and welding performed as part of a permitted construction activity. A-301.2.3 Electrical permits: An electrical permit shall not be required for the following activities: 1. Minor repair and maintenance work including, the replacement of lamps, circuit breakers and fuses; repairing or replacement of switches, lamp sockets, ballasts, drop cords, receptacles, bulbs; taping bare joints; and replacing lighting fixtures to existing connections. 2. The connection of approved portable electrical equipment to approved permanently installed receptacles. 3. The installation, alteration or repair of electrical equipment of a regulated public utility for its use in the generation, transmission, distribution or metering of electricity. 4. The installation of a temporary system required for the testing or servicing of electrical equipment or apparatus. 5. Removal of electrical wiring in the total demolition of a structure. 6. The installation of electrical componentry used in connection with the installation or reinstallation of partition systems listed in published reports of inspected electrical equipment by the Underwriters Laboratories, Inc. (UL). 7. The installation of low voltage wiring in one- and two-family and Group U occupancies. 8. Installations in railway cars or automotive equipment. 9. The installation of conductors or equipment for or by public utilities, common carriers or commercial radio or television stations that are under the jurisdiction of the Commonwealth of Pennsylvania or a federal regulatory body. This exemption applies only to conductors and equipment used directly in the conduct of the entity's business as a utility, common carrier or commercial radio or television station and that are located either outdoors or in a building or portion thereof used exclusively for the business function of such entity. A-301.2.4 Plumbing permits: A plumbing permit shall not be required for the following activities: 1. Minor repairs including the replacement of faucets or valves or parts thereof with like material or material serving the same purpose; or the removal and reinstallation of water closets, provided the work does not include the replacement or rearrangement of valves, pipes or fixtures. 2. The sealing of sewer laterals for building demolitions contracted by the Department. 3. Stopping leaks in a drain, water, soil, waste, or vent pipe provided that no piping is replaced with new material. 4. Clearing stoppages or repairing leaks in pipes, valves or fixtures, provided that valves, pipes or fixtures are not replaced or rearranged. A-301.2.5 Zoning and use registration permits: A zoning or use registration permit shall not be required for the following activities: 1. Construction and use of structures totally outside of lot lines. 2. A use registration permit is not required for single-family dwellings. 3. Alterations to an existing structure which do not change the area, height, floor area or bulk of the structure and the existing use is legal and unchanged. 4. Temporary uses, structures and signs for special events of a limited time period, typically open to the public and of a non-commercial nature, as approved by the Code Official after consideration of the impact on the immediate area. 5. Mobile Food Vendors, licensed under Section 9-203 of this Code and operating on privately-owned property, provided that such vendors comply with all of the requirements of subsection 9-203(10). 6. Demolitions performed under contract with the Department and in compliance with current Procurement Department Specifications. 7. Fences at or below the height allowable by the Zoning Code (Title 14). 8. Swimming pools accessory to one- and two-family dwellings. 9. Canopies or awnings accessory to a one- or two-family dwelling, provided the canopy or awning does not exceed 120 square feet. 10. Sheds, playhouses, pergolas and similar structures accessory to one- or two-family dwellings, provided the structure is located in the rear yard and does not exceed 130 square feet and 15 feet in height. 11. Temporary motion picture, television and theater sets and scenery. 12. Concrete or other hard surface materials on grade, such as driveways, walkways and patios not used for parking. 13. Decks within building lines, not more than 12 inches above the ground surface below and not over any basement or story below. 14. Decks located in the rear yard and accessory to one-family dwellings allowable by the Zoning Code (Title 14). 15. Building service equipment, such as mechanical, electrical or plumbing equipment, including necessary mounting systems, required to operate and maintain facilities located on the same lot. To qualify for this exemption, the equipment may not be located within a required setback from the street nor conflict with any dimensional restriction of the Zoning Code. A-301.3 Form of application: The application for a permit shall be submitted in such form as this Code requires and as the department prescribes and shall be accompanied by the required fee as prescribed in Chapter 9. A-301.4 By whom application is made: Application for a permit shall be made by the owner or lessee of the building or structure, or agent of either, by the registered design professional employed in connection with the proposed work; by any person or entity with written documentation of equitable ownership of that real property; by a conservator of the property; or other licensed person authorized to apply by the codes. If the application is made by a person other than the owner in fee, it shall be accompanied by a signed statement or electronic confirmation of the qualified applicant to the effect that the proposed work is authorized by the owner in fee and that the applicant is authorized to make such application. With respect to (1) building permits required pursuant to Section A-301.1.1 and (2) zoning and use permits required pursuant to Section A-301.1.5, if the owner of the property is not a natural person or a publicly traded company, the application shall identify, in addition to the owner of the property, the name and preferred mailing address of each natural person who has an equity interest in such owner or owners of the property that exceeds one or more of the following, regardless of whether the natural person has a direct equity interest or such natural person's equity interest is held through one or more tiers of a corporate structure, such as parent-subsidiary structure: (a) forty-nine percent (49%) of the value of the property or (b) forty-nine percent (49%) of the value of the owner of the property. If no natural person has such an interest, the application shall identify the name and preferred mailing address of the two natural persons who have the largest equity interest in the property. A-301.5 Contents of application: Every permit application shall, to the extent applicable: 1. Contain a general description of the proposed work. 2. Provide the specific street address of the proposed work. 3. Further identify the location of the proposed work if in a portion of a structure. 4. State the occupancy of the structure and for which the proposed work is intended. 5. State the total valuation of the work for which application is made. 6. Be signed by the applicant or when required, by the licensed holders. 7. State the name, address and license number of licensed contractor(s) who will perform work under the permit. 8. Provide the Commercial Activity License numbers of contractors, design professionals, agents, owners, lessors, etc. as appropriate to the application. 9. Give such additional information as required by the department. A-301.6 Construction documents: Applications for permits shall be accompanied by construction documents that include the information required by Section A-305.0, the technical codes, regulations, plan submission standards, and any other information that the code official determines is necessary to issue the permit. As used in this Chapter, construction documents shall include demolition plans as described in Section A-305.2.2.1. When paper copies of any construction documents are submitted, three sets shall be required, and the applicant shall be required to pay an electronic imaging fee as established by regulation. The code official may waive the requirement for the submission of construction documents in accordance with Section A-305.1.1. A-301.7 Amendments to application: Subject to the limitations of Section A-301.8, amendments to a plan, application or other records accompanying the same shall be filed at any time before completion of the work for which the permit is sought or issued. Such amendments shall be deemed part of the original application and shall be filed therewith and requisite fees paid. A-301.7.1 Zoning and use registration permit amendments: Amendments to zoning and use registration permits shall be subject to the Code provisions in effect on the date the amendment application is filed. A-301.8 Time limitation of application: An application for a permit for any proposed work shall be deemed to have been abandoned 60 days after the date of any request by the Department for information from the applicant or 60 days after notification by the Department that the application is approved and available for pick-up, unless the applicant provides any requested information to the Department and has taken the necessary steps to pick up the permit from the Department. The code official may grant one or more extensions of time for additional periods not exceeding 90 days each if there is reasonable cause. A-301.8.1 Court order: The Department is authorized to deem abandoned any permit application where a Court of proper jurisdiction has authorized the Department to act upon its police powers to abate an unsafe condition. A-301.9 Waste collection plan: The applicant for any building or demolition permit that requires the submission of plans must list on the building permit application the names of all waste haulers. Copies of all tipping receipts and evidence of proper disposal must be retained for audit upon request for three (3) years after the building permit is finalized. Failure to properly dispose of construction, demolition, or alteration debris on a project on any size, regardless of the need for a permit, shall result in the suspension or revocation of the Contractor License in addition to any criminal penalties that may be imposed. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012; amended, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017.] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 200160 (approved October 15, 2020); amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Renumbered, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023 ; renumbered and amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 250043 (became law September 11, 2025).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 120774-A (approved January 14, 2013); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 070821 (approved November 15, 2007).] [History: Amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012 ; amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 090842 (approved January 13, 2010).] [History: Amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012; amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 210135-AA (approved May 11, 2021); subsection (4)(a) deleted, Bill No. 260073 (approved March 30, 2026).] [History: Added, Bill No. 150056-A (approved May 5, 2015).] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 200417 (became law November 12, 2020), effective January 1, 2022.] [History: Amended, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 170898 (approved December 20, 2017); subsection 10 deleted, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 110758 (approved December 21, 2011), effective May 1, 2012.] [History: Amended, Bill No. 130698-A (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 180175 (approved June 6, 2018).] [History: Enrolled bill referenced A-301.5(10)(c), which was renumbered to A-305.2.2.1 and amended by Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 200260 (approved October 15, 2020).] [History: Amended, Bill No. 070821 (approved November 15, 2007).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 160768 (approved January 3, 2018), effective January 1, 2019.] SECTION A-302 PERMITS A-302.1 Action on application: The Department shall examine or cause to be examined all applications for permits and amendments thereto. If the application or the construction documents do not conform to the requirements of all pertinent laws, the code official shall reject such application in writing, stating the reasons therefor. If the code official is satisfied that the proposed work conforms to the requirements of this code and the technical codes and all laws and ordinances applicable thereto, the code official shall issue a permit therefor as soon as practicable upon payment of requisite fees. A-302.1.1 Time limits for permit application consideration. The code official shall grant or deny a complete permit application in whole or in part or request further information, within the following number of business days after the filing date: 1. for commercial construction, 20 days, to the extent capacity permits, but in no event more than 30 days. 2. for residential construction, 15 days. 3. for building and trade permit applications for affordable housing projects, as defined in Section A-106, 10 days. 4. for accelerated review provided under Section A-901.10, including zoning permit applications for affordable housing projects, 5 days. A-302.1.2 Application amendments: The code official shall endeavor to grant or deny a complete application for an amendment to a permit within 10 business days of the filing date, provided the amendment is the result of an unforeseen field condition or constraint that necessitates a change in configuration, design, or materials. An applicant may obtain accelerated plan review pursuant to the requirements of Section A-901.10 for any application for an amendment to a permit. A-302.1.3 Imminently dangerous structures: If the permit application is for an imminently dangerous structure as determined under the Property Maintenance Code Section PM-110, then the code official shall preliminarily review such application for completeness at the time submitted, and shall grant or deny a complete permit application within 5 business days of receipt. Reasons for a denial shall be in writing and sent to the applicant. A-302.1.4 Extension of consideration time limits: When agreed to by the code official and the permit applicant in writing, the deadline for action shall be extended by the number of days specified in the agreement. In connection with any application for accelerated review under Section A-901.10, the Department may determine, in writing provided to the applicant, that resource constraints prohibit compliance with the 5-day time line and may extend the time limit for up to an additional 5 days. A-302.1.5 Time limits for historic properties: The deadline for action on permits for structures that have been designated as historic or are located in an historic district is no earlier than the time of decision on the application by the Historical Commission. A-302.1.6 Accelerated zoning plan review: Upon payment of the fee, the department shall complete its plan review of any zoning application that is subject to civic design review under subsection 14-304(5) and issue a decision no later than ten business days after submission of a complete application, absent an emergency that would prevent such completion. A-302.1.7 Substantially improved or substantially damaged existing buildings in flood hazard areas. For applications for reconstruction, rehabilitation, addition or other improvement of existing buildings or structures subject to the technical codes and located in a flood hazard area as established by the Flood Insurance Rate Map (FIRM) of the U.S. Department of Homeland Security Federal Emergency Management Agency (FEMA), the code official shall examine or cause to be examined the construction documents and shall prepare a finding with regard to the value of the proposed work. For buildings that have sustained damage of any origin, the value of the proposed work shall include the cost to repair the building or structure to its pre-damage condition. If the code official finds that the value of proposed work equals or exceeds fifty percent (50%) of the market value of the building or structure before the damage has occurred or the improvement is started, a determination of substantial improvement or substantial damage shall be issued and the applicable requirements of the Building Code or Residential Code shall be applied. The term substantial improvement shall not include: 1. Improvements of a building or structure required to correct existing health, sanitary or safety code violations identified by the code official and which are the minimum necessary to assure safe living conditions; or 2. Any alteration of an historic building or structure, provided that the alteration will not preclude the continued designation as an historic building or structure. For the purposes of this exclusion, an historic building is: 2.1 Listed or preliminarily determined to be eligible for listing in the National Register of Historic Places; or 2.2 Determined by the Secretary of the U.S. Department of Interior as contributing to the historical significance of a registered historic district or a district preliminarily determined to qualify as an historic district; or 2.3 Designated as historic under Chapter 14-1000 of The Philadelphia Code. If the building or structure has sustained substantial damage, all repairs are considered substantial improvement regardless of the actual repair work performed. A-302.2 Suspension of permit: Any permit issued shall become invalid if the authorized work is not commenced within six months after issuance of the permit, or if the authorized work is suspended or abandoned for a period of six months after the time of commencing the work. The code official is authorized, for reasonable cause, to extend in writing the time for commencing or suspending the work for a period not exceeding six months upon written request of the permittee. A maximum of two extensions for a total period not exceeding twelve months may be granted to extend the time to commence work. A maximum of one extension for a period not exceeding six months may granted to extend time on suspended work. In order to proceed with the work authorized by an expired permit, a new permit shall be obtained. Exception: Those permits regulated by Sections A-302.2.1 through A-302.2.5. A-302.2.1 Fire permits shall be limited to the time period specified by the permit. A-302.2.2 Zoning and use registration permits: See subsection 14-303(10). A-302.2.3 Permits related to imminently dangerous and unsafe structures or conditions. 1. For permits issued in connection with imminently dangerous structures or conditions (see PM-110.1 ), the permit shall become invalid if the work does not commence within 10 days after issuance or does not progress continuously until the structure or condition is made safe, unless the permit is otherwise extended by the Department. 2. For permits issued in connection with an unsafe structure or condition (see PM-108, PM-109 ), the permit shall become invalid if the work does not commence within 30 days after permit issuance or does not progress continuously until the structure or condition is made safe, unless the permit is otherwise extended by the Department. A-302.2.4 Rough-in permits. A rough-in permit shall become invalid if the work is not initiated and the associated complete permit is not obtained within 60 days of issuance. A-302.2.5 Construction permits. Pursuant to the UCC, a permit issued for construction or demolition under the authority of the UCC may be valid for no more than 5 years from its issue date. A-302.3 Previous approvals: This code and the technical codes shall not require changes in the construction documents, construction or designated occupancy classification of a building or structure for which a permit has been issued pursuant to the requirements of a previously adopted code(s) and the construction of which has been actively pursued within the time periods specified by Section A-302.2. A-302.4 Signature to permit: The code official charged with the review of permit applications and related construction documents shall affix a signature or provide electronic approval to each approved application and/or permit in accordance with procedures of the department. A-302.5 Construction documents: Upon approval, the code official shall stamp or endorse electronic approval on each page of construction documents, unless otherwise specified. Such approved construction documents shall not be changed, modified or altered without authorization from the code official. Work shall be done in accordance with the approved construction documents and required non-design changes marked thereon by the code official. A-302.5.1 Distribution: The approved construction documents shall be distributed as follows: 1. One set shall be retained in the records of the Department according to the established retention schedule. 2. One set shall be available to the appropriate inspection office. 3. One set shall be returned to the applicant. A paper copy shall be retained by the applicant at the construction site and shall be available for inspection by the code official. A-302.5.2 Responsibility: Construction documents approved by the Department are approved with the intent that such construction documents comply in all respects with this code and the applicable technical codes. Any omissions or errors on the construction documents do not relieve the applicant or other responsible persons of having to comply with all applicable requirements of this code and the technical codes. The issuance of a permit based on construction documents and other data shall not prevent the code official from requiring the correction of errors in the construction documents and other data. The code official is authorized to prevent occupancy or use of a structure where in violation of The Philadelphia Code. A-302.6 Foundation permit: The code official is authorized to issue a permit for the construction of foundations before the construction documents for the entire structure have been submitted provided the zoning permit for the entire structure has been issued and provided that appropriate construction documents and required statements have been filed. Approval of the Philadelphia Water Department for water and sewer availability and storm water management is required prior to the issuance of a foundation permit. A-302.6.1 Related work: Issuance of a foundation permit for a structure shall be the basis for issuance of plumbing and electrical permits for such work below grade. A-302.6.2 Owner's risk: The owner of a structure for which a foundation and related permits have been issued shall proceed at the owner's risk without assurance that a permit for the entire structure will be granted. Issuance of a foundation permit shall not be construed to establish vested rights to the building or related permits on the part of any party to the construction project. A-302.7 Annual permit. In lieu of an individual permit for each repair, replacement, maintenance operation or alteration to an already approved electrical, gas, mechanical, or plumbing installation, the code official is authorized to issue an annual permit upon application therefor. The work authorized under an annual permit does not include new installations or the extension of existing systems. The applicant shall be a person, firm, institution or corporation regularly employing one or more qualified trade persons in the building, structure, or on the premises owned or operated by the applicant for the permit. A licensed trades person employed by the firm, institution or corporation and responsible for the work regulated by the permit shall be identified prior to the issuance of the annual permit. A-302.7.1 Records. The entity to whom an annual permit is issued shall keep a detailed record of all work performed under the annual permit. The work record shall be available for inspection by the code official at all times, or at the code official's discretion, shall be filed with the code official. A-302.8 Posting of permits and licenses: Permits and licenses shall be kept on the premises designated therein at all times and shall be readily available for inspection by the code official. A true copy of all permits or notice of permits issued by the Department authorizing construction activity shall be posted on the site of the operations, open to public inspection during the entire time of the prosecution of the work for which the permit has been issued. Each permit or notice of permit required to be posted by this subsection shall include the full name and address of the owner; provided, further, that if the owner is not a natural person, the posting shall also include the full names and addresses of the owner's responsible officers. If the owner is not a natural person or a publicly traded company, the permit or notice of permit shall also include, in addition to the owner of the property, the name and preferred mailing address of each natural person who has an equity interest in such owner or owners of the property that exceeds one or more of the following, regardless of whether the natural person has a direct equity interest or such natural person's equity interest is held through one or more tiers of a corporate structure, such as parent-subsidiary structure: (a) forty-nine percent (49%) of the value of the property or (b) forty-nine percent (49%) of the value of the owner of the property. If no natural person has such an interest, the permit or notice of permit shall identify the name and preferred mailing address of the two natural persons who have the largest equity interest in the property. The Department shall be authorized to establish Regulations for additional posting and signage requirements related to construction. Exceptions: 1. Rental license, where there is no on-premises management office. 2. The posting of zoning and use registration permits shall be regulated by Title 14. A-302.8.1 Insurance certificates: An applicant, developer, and/or contractor who obtains a permit for new construction or demolition operations shall procure and maintain, in full force and effect for the duration of the operations, at applicant’s own expense, an insurance policy also naming the adjoining or adjacent address as an additional insured, and submit such certificate of insurance to the Department, which shall make this information publicly available and shall include such certificate of insurance in any notifications to adjacent or adjoining property owners pursuant to requirements under Section A-305.2.2.6. The policy shall afford comprehensive general liability insurance in accordance with insurance limits based on license types as determined by the Department, including products and completed operations coverage and contractual liability insurance covering any indemnification and hold harmless obligations. The holder of any permit authorizing construction activity shall maintain a true copy of the developer or contractor’s certificate of insurance on the site of the operations, open to public inspection upon request during the entire time that the construction permit or notice of permits issued by the Department is to be posted, and shall supply a copy of the certificate of insurance to the adjoining or adjacent address(es). The applicant, developer and/or contractor shall notify the adjoining or adjacent address(es) in writing upon the expiration of coverage for any reason within ten (10) days. A-302.9 Revocation of permit: The code official is authorized to revoke a permit or approval issued pursuant to the provisions of this code and the technical codes in case of any of the following: 1. The permit was issued in error. 2. The permit was issued on the basis of incorrect, inaccurate or incomplete information in the application or construction documents. 3. The permit was issued on the basis of false statement or misrepresentation of fact in the application or construction documents. 4. An ordinance, regulation, or condition of permit has been violated. 5. Work is being conducted in an unsafe manner. 6. A Stop Work Order or Cease Operations Order has been issued. A-302.9.1 Correction: When the department determines that grounds exist for the revocation of a permit, it shall serve written notice upon the permit holder, stating the nature of the violation. The Department is authorized to allow for a reasonable period within which compliance with all the requirements of such permit shall be achieved. The notice may also describe a course of remedial action. A-302.10 Conditions of permit: Permits issued pursuant to this code and the technical codes are subject to the conditions stated in Sections A-302.10.1 through A-302.10.5 as applicable. A-302.10.1 Payment of fees: A permit shall not be issued until the fees prescribed in Chapter 9 have been paid. A-302.10.2 Compliance with code: The permit shall be a license to proceed with the work and shall not be construed as authority to violate, cancel or set aside any of the provisions of this code or the technical codes, except as specifically stipulated by legally granted variance. A-302.10.3 Compliance with permit: All work shall conform to the approved application and the approved construction documents for which the permit has been issued and any approved amendments to the approved application or the approved construction documents. Permits are not transferable except by approval of the department. A-302.10.4 Compliance with site plan: All new work shall be located strictly in accordance with the approved site plan. A-302.10.5 Asbestos inspection report: A permit for any demolition or alteration in excess of fifty thousand dollars ($50,000) shall not be issued until an asbestos inspection report including all laboratory sample reports and analyses, furnished by an independent certified asbestos investigator as defined in Section 6-601 of the Philadelphia Health Code, has been submitted. Submission of an asbestos inspection report is not required for buildings erected pursuant to a building permit issued after December 31, 1980, or any residence with three dwelling units or less. The Department is responsible for forwarding the submitted asbestos inspection report to the Department of Public Health for review and appropriate action. Notwithstanding this requirement, where asbestos is found, all regulations of the Department of Public Health shall be followed. A-302.11 Temporary structures and uses. Subject to the exclusions established by the UCC in Section A-102.1 of this code, the code official is authorized to issue a building permit for temporary structures and temporary uses. Such permits shall be limited as to time of service, but shall not be permitted for more than 180 days. The code official is authorized to grant extensions for demonstrated cause. A-302.11.1 Conformance. Temporary structures and uses shall comply with the relevant requirements of Chapter 31 of the Building Code. A-302.11.2 Termination of approval. The code official is authorized to terminate such permit for a temporary structure or use and to order the temporary structure or use to be discontinued. A-302.12 Partial completion and abandonment of work. A-302.12.1 Completion requirement. The permit holder shall complete the full scope of work authorized under the permit. A-302.12.2 Partial Completion. Work that is partially completed under a permit that subsequently expires pursuant to Section A-302.2 shall require the submission of a new permit application. The new application shall serve to: 1. Legalize the partially completed work; 2. Obtain approval for any remaining work; or 3. Authorize demolition or removal of partial construction to restore the site to its original condition. New permit applications shall be subject to all requirements in effect at the time of submission. Construction exposed to weather or that has sustained damage may require certification of a Pennsylvania-licensed professional engineer or replacement, as determined by the Department. A-302.12.3 Site maintenance and safety. Where there is partially completed work under a permit that subsequently expired, the permit holder shall ensure that the site is maintained in a safe and secure manner and complies with all applicable requirements of the Building Code and any additional protection requirements established by the Department. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: A mended, Bill No. 190767 (approved November 12, 2019), effective July 1, 2020.] [History: Amended, Bill No. 250043 (became law September 11, 2025).] [History: Amended, Bill No. 250043 (became law September 11, 2025).] [History: Amended, Bill No. 130698-A (approved February 19, 2014); amended, Bill No. 160469 (approved June 28, 2016); amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 220384 (approved July 6, 2022) .] [History: Amended, Bill No. 070821 (approved November 15, 2007).] [History: Added, Bill No. 090127 (approved June 3, 2009); amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012.] [History: Added, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 020758 (approved January 31, 2003), effective January 1, 2003; amended, Bill No. 130691-A (approved February 19, 2014). Section 6 of Bill No. 130691-A provides: "The provisions of this Ordinance that are subject to review under the Pennsylvania Construction Code Act (Act 45 of 1999, P.L. 491, as amended) shall not become effective until the Secretary of the Pennsylvania Department of Labor and Industry certifies approval of this Ordinance or the City Solicitor certifies to the Chief Clerk of Council that the requirements of Section 503 of Act 45 of 1999, as amended (35 P.S. sec. 7210.503), have otherwise been satisfied so as to permit the Ordinance to go into law. The remainder of this Ordinance shall take effect immediately." The Pennsylvania Department of Labor and Industry provided the necessary approval on January 15, 2014. Pursuant to 35 P.S. § 7210.503(j), the provisions are effective 35 days after enactment, i.e., March 27, 2014. Amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 200417 (became law November 12, 2020), effective January 1, 2022.] [History: Added, Bill No. 060346 (approved September 14, 2006); amended, Bill No. 240304-A (approved January 20, 2026), effective January 1, 2025 .] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Enrolled Bill No. 030780 read "A-302.9.1 through A-302.9.5".] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 130685 (approved February 19, 2014), effective within 18 months (August 19, 2015); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] SECTION A-303 DEMOLITION AND RELOCATION OF STRUCTURES A-303.1 Service connections: Before a structure is demolished or removed, the Demolition Contractor licensed pursuant to Section 9-1008 of The Philadelphia Code responsible for the demolition shall notify all utilities having service connections within the structure such as water, electric, gas, sewer and other connections. Service connections and appurtenant equipment, such as meters and regulators shall be removed or sealed and plugged in a safe manner. A-303.2 Posting and Notice: Upon submittal of an application for a permit for the demolition of a structure, the department shall provide a notice to the Demolition Contractor to be posted prior to the demolition of the structure. The Demolition Contractor shall post such notice on the structure to be demolished. Upon issuance of the building permit for the demolition, and in addition to the notification requirements for contractors established in this Section and the Building Code, the department is authorized to distribute an informational bulletin indicating that the City or owner intends to demolish said structure. The department shall distribute the informational bulletin to the properties located within a 250 foot radius of the subject property, the Councilmember whose district includes the property, and any Registered Community Organization the registered boundaries of which include the property. The requirement to distribute an informational bulletin shall not create any actionable right for any resident or owner of the subject property or any neighboring property. Exceptions: 1. In the event of an emergency which requires immediate action to protect the health or safety of the public, which shall include any time the Department has served notice of a requirement to demolish an imminently dangerous structure under Section PM-110.2 of this Title and demolition is carried out within 10 days of service by the Department of the notice requiring demolition; provided that the Department distributes the informational bulletin to any property abutting the property on which a structure is to be demolished. 2. When the structure has been posted as required by subsection 14-303(13) of The Philadelphia Code. 3. When the structure has been the subject of a variance granted by the Zoning Board of Adjustment. A-303.2.1 Location and Time: The notice shall be posted by the Demolition Contractor on each street frontage of the premises with which the notice is concerned. Posted notices shall remain until demolition of the structure, which shall not commence less than 21 days from the date of the initial posting of the notice. A-303.2.2 Content: Such posted notice shall be clearly visible to the public. All notices shall contain the date on which the permit application for demolition was submitted to the Department. A-303.2.3 Removal: No person shall remove such notice prior to the approved date on which demolition is permitted to commence, unless the owner notifies the department that the structure will not be demolished and the permit has been revoked by the department upon such request, in which case, the Demolition Contractor shall remove the notice. A-303.2.4 Penalties: Any Demolition Contractor who violates the provisions of this Section shall be subject to penalties as prescribed in Chapter 6. A-303.2.5 Additional posting and notice: The Department shall include in any informational bulletin distributed pursuant to this Section all of the following: education material explaining the inherent safety risks of demolition; contractor obligations regarding party walls; information concerning shoring and bracing of walls; waterproofing and enclosure of breaches for interior walls that become exterior walls, and other required finishings. A-303.3 Permits: A demolition permit shall be valid only in connection with work performed by the licensed Demolition Contractor identified on the permit. A Demolition Contractor that seeks to perform demolition work under a permit identifying another contractor must obtain an amendment of such permit that authorizes work by the new Demolition Contractor. A-303.4 Moved structures: Before any structure which has been moved is occupied, the structure and mechanical equipment shall be inspected for safe use and operation and for compliance with applicable provisions of this code and the technical codes. A-303.5 Current or Former Religious Facilities: The Department shall verify whether the structure that is the subject of a demolition permit is currently or was formerly used as a church, synagogue, mosque, or other religious facility. If the structure that is the subject of a demolition permit is currently or was formerly used as a church, synagogue, mosque, or other religious facility and is at least 50 years old, then the Department shall not issue a permit for demolition, until: 1. The Department notifies the District Councilmember and Registered Community Organization (RCO) of the application of a demolition permit for the structure; 2. The Department receives confirmation that the RCO held a meeting to discuss the demolition of the structure within 30 days of receiving notice of the demolition; and 3. The Department fully considers the position of the RCO in making the decision of whether to issue a permit for the structure. [History: Amended, Bill No. 160075 (approved May 10, 2016). Section 2 of Bill No. 160075 provides: "The provisions of this Ordinance that are subject to review under the Pennsylvania Construction Code Act (Act 45 of 1999, P.L. 491, as amended) shall not become effective until the Secretary of the Pennsylvania Department of Labor and Industry certifies approval of this Ordinance or the City Solicitor certifies to the Chief Clerk of Council that the requirements of Section 503 of Act 45 of 1999, as amended (35 P.S. sec. 7210.503), have otherwise been satisfied so as to permit the Ordinance to go into law." The Pennsylvania Department of Labor and Industry provided the necessary approval on March 25, 2016. Pursuant to 35 P.S. § 7210.503(j), the provisions are effective 35 days after enactment, i.e., June 14, 2016.] [History: Amended, Bill No. 020411 (approved October 15, 2002); Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions. Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 210677 (approved June 22, 2022) .] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 120774-A (approved January 14, 2013).] [History: Amended, Bill No. 020411 (approved October 15, 2002); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 020411 (approved October 15, 2002).] [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions. Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 220110 (became law September 15, 2022).] SECTION A-304 REGISTERED DESIGN PROFESSIONAL SERVICES A-304.1 General: The construction documents for new construction, alteration, repairs, expansion, addition or modification for buildings or structures required for a permit application shall be prepared by a registered design professional consistent with the professional registration laws of the Commonwealth of Pennsylvania. Where special conditions exist, the code official is authorized to require additional construction documents to be prepared by a registered design professional. The construction documents shall include the name and address of the registered design professional and shall be signed, sealed and dated by the registered design professional in accordance with the professional registration laws. Exceptions: 1. A registered design professional is not required to prepare the construction documents for the remodeling or alteration of a building where there is no compensation paid for such preparation and the remodeling or alteration does not relate to additions to the building or changes to the building's structure or means of egress and where the cost of the work is less than twenty-five thousand dollars ($25,000). 2. A registered design professional is not required to prepare designs submitted under the provisions of Chapter 24 of the Residential Code for residential buildings having a conditioned floor area of 5,000 square feet (465 m2) or less, provided a qualified person prepares such designs. 3. The seal of a registered design professional shall not be required for ground floor additions to one- and two-family buildings of less than 120 square feet. A-304.2 Special inspections: Special inspections shall be made in accordance with the Building Code. A-304.2.1 Building permit requirement: The special inspection requirements shall be determined prior to the issuance of the building permit and shall be a requisite for the permit issuance as described in the Building Code. A-304.2.2 Fees and costs: All fees and costs related to the performance of special professional services shall be borne by the owner. A-304.3 Design professional in responsible charge: When it is required that documents be prepared by a registered design professional, the code official is authorized to require the owner to engage and designate on the permit application, a registered design professional who shall act as the registered design professional in responsible charge. If the circumstances require, the owner shall designate a substitute registered design professional in responsible charge, who shall perform the duties required of the original registered design professional in responsible charge. The code official shall be notified in writing by the owner if the registered design professional in responsible charge is changed or is unable to continue to perform the duties. The registered design professional in responsible charge shall be responsible for reviewing and coordinating submittal documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building. A-304.3.1 Deferred submittals: For the purposes of this Section, deferred submittals are defined as those portions of the design that are not submitted at the time of the application and that are to be submitted to the code official within a specified period. Deferral of any submittal items shall be subject to the prior approval of the code official. The registered design professional in responsible charge shall list the deferred submittals on the construction documents for review by the code official. Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the code official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall not be installed until their design and submittal documents have been approved by the code official and any additional or amended permits have been issued. [History: Amended, Bill No. 030780 (approved December 31, 2003); caption amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-305 CONSTRUCTION DOCUMENTS A-305.1 General. Submittal documents consisting of construction documents and other data shall be submitted with each permit application. Plans shall be drawn on suitable material, generally to scale, dimensioned, and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed. Plans shall show in detail that the work will conform to the provisions of the technical codes including applicable items specified in this Section A-305 and all applicable standards, regulations and ordinances. The Department is authorized to develop and require the submittal of forms to collect required information in a consistent format. Where special conditions exist, the building official is authorized to require additional construction documents to be prepared by a registered design professional. A-305.1.1 Waiver. The code official is authorized to waive the submission of construction documents and other data that is not required to be prepared by a registered design professional where the code official determines that the nature of the work applied for is such that review of construction documents is not necessary to obtain compliance with the technical codes. A-305.1.2 Plan submission standards. The Department is authorized to establish plan submission standards. Electronic media documents may be submitted where approved by the Department. A-305.1.3 Material quality. Where the quality of the materials is essential for conformity to the technical codes, specific information shall be given to establish such quality, and the code shall not be cited, nor shall the term "legal" or its equivalent be used as a substitute for specific information. A-305.1.4 Engineering details. Construction documents shall include adequate details of structural, mechanical, plumbing and electrical work, including computations, diagrams and other essential technical data as determined by the code official. A-305.1.5 Fire and zoning permits. Applications for fire permits and zoning permits shall be accompanied by such documentation as this Section, the technical codes, regulations and departmental procedures require. A-305.2 Contents. The construction documents for permitting shall contain the information required by the technical codes and additional provisions included in A-305.2.1 through A-305.2.6. Required approvals for each permit are provided herein. Additional officials or agencies may be involved based on the character of the permit application or the size or type of development involved. No provision of this Section adds to or detracts from a power, duty, or responsibility granted to any board, commission, department, committee, or agency of the City by a grant of power, duty, or responsibility in another Section of The Philadelphia Code or by the Philadelphia Home Rule Charter. In the case of any conflict between the provisions of this Section and the Philadelphia Home Rule Charter or other provisions of The Philadelphia Code, including this Administrative code, the provisions of the Philadelphia Home Rule Charter or The Philadelphia Code shall govern. A-305.2.1 Building permits. Specific requirements for building permits include the items or data included in A-305.2.1.1 through A-305.2.1.7. Other requirements for building permit application construction documents are found in the appropriate Sections of the technical codes. A-305.2.1.1 Site plan. In the case of new construction and additions, building permit applications shall be accompanied by a site plan showing to scale the size and location of all new construction and all existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades, and as applicable, flood hazard areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate boundary line survey. Required accessibility features shall be shown including but not limited to: parking spaces, public transportation stops and accessible routes. In the case of multiple spaces, buildings or parcels, the site plan shall include a key plan to identify the uses, spaces and structures within the site. For buildings and structures in flood hazard areas the site plan shall include the delineation of flood hazard areas, floodway boundaries, and flood zones. Submitted site plans shall be generally consistent with the site plans approved by the zoning permit for the construction. A-305.2.1.2 Code analysis information. Code analysis information shall be submitted with the construction documents. The code analysis information shall include the construction type, use and occupancy classification, means of egress information, occupant loads, and fire protection elements. A-305.2.1.3 Flood protection. If any proposed construction or development is located entirely or partially within any identified floodplain area, in addition to the requirements of the Building or Residential Code, the construction documents shall provide all the necessary information in sufficient detail and clarity to enable the code official to determine that: 1. all such proposals are consistent with the need to minimize flood damage and conform with the requirements of the technical codes; 2. all utilities and facilities, such as sewer, gas, electrical and water systems, are located and constructed to minimize or eliminate flood damage; 3. adequate drainage is provided to reduce exposure to flood hazards; 4. structures will be anchored to prevent flotation, collapse, or lateral movement; 5. building materials are flood-resistant; 6. appropriate practices that minimize flood damage have been used; and 7. electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities have been designed and located to prevent water entry or accumulation. A completed Flood Elevation Certificate (or Floodproofing Certificate as applicable) as published by FEMA shall also be submitted. A-305.2.1.4 Energy conservation. Supporting documentation shall be required to detail compliance with energy conservation requirements. The building's thermal envelope shall be represented on the construction drawings. A-305.2.1.5 Foundation and soils investigations. The soil classification and design load-bearing capacity shall be shown on the construction documents. The owner or applicant shall submit a foundation and soils investigation to the code official where required in the Building Code. Where required by the code official, a written report of the soils investigation shall be prepared and sealed by a professional engineer licensed by the Commonwealth of Pennsylvania and submitted for any new construction, additions or foundations. A-305.2.1.6 Requisite approvals. The following approvals of departments and agencies of the City of Philadelphia and/or the Commonwealth of Pennsylvania shall be required before a building permit may be issued: 1. Zoning. A zoning and/or use registration permit shall be required for any change in use of the property, new construction or any changes in the gross floor area or height of an existing building in accordance with Title 14 of The Philadelphia Code. 2. Philadelphia Water Department. The approval of the Philadelphia Water Department is required for conditions set forth in Pa. Act 537 and the Clean Streams Act, and to confirm water and sewer availability. 3. Philadelphia Streets Department. Philadelphia Streets Department approval is required as per Title 11 of The Philadelphia Code, including but not limited to curb cuts, encroachments and parking lots. 4. Pennsylvania Department of Health. Pursuant to the UCC, Pennsylvania Department of Health approval is required for healthcare facilities. 5. Philadelphia Historical Commission. Philadelphia Historical Commission approval is required for all work performed on properties listed on the Philadelphia Register of Historic Places in accordance with Title 14 of The Philadelphia Code. 6. Philadelphia Art Commission. Philadelphia Art Commission approval is required as per the Philadelphia Home Rule Charter and Title 14 of The Philadelphia Code. 7. Parks and Recreation. Parks and Recreation approval is required as per Titles 14 and 15 of The Philadelphia Code. 8. Philadelphia Fire Department. Philadelphia Fire Department approval is required as per Subcode F of Title 4 of The Philadelphia Code. 9. Philadelphia City Planning Commission. Philadelphia City Planning Commission approval is required per Title 14 of The Philadelphia Code. 10. Philadelphia Department of Public Health approval is required prior to permit issuance for buildings connected to an on-lot sewage disposal system and for dust control measures associated with clearing, grubbing, or earth disturbance of any land in excess of 5,000 square feet. Acceptance of water quality from a private well is required prior to final permit approval. A-305.2.1.7 Monitoring plan. A monitoring plan must be submitted where required by the Philadelphia Building Code. The plan must be prepared by a licensed professional engineer and specify scope of monitoring, frequency, and acceptable tolerances. A-305.2.1.8 Preconstruction Survey. Where required by the Philadelphia Building Code, a preconstruction survey prepared by a licensed professional engineer that documents the existing conditions of all adjoining and adjacent buildings and that identifies any potential hazards must be submitted. A-305.2.1.9 Notification. Where required by the Building Code, proof of notification to the property owner of all adjoining and adjacent buildings must be submitted. A-305.2.2 Demolition permits. Construction documents for a permit for the complete demolition of a structure shall be submitted in accordance with Sections A-305.2.2.1 through A-305.2.2.6. Exception: Construction documents for demolition permits are not required for demolition of a one-story structure of 500 square feet or less when no other structures are located within ten (10) feet of the structure, unless the Department determines that provision of such documents is necessary to address health and safety concerns. A-305.2.2.1 Site Safety Plan. A site safety demolition plan or complete "engineering survey" as required by the Occupational Safety and Health Administration (OSHA) regulations developed by a competent person shall be submitted. The plan must address the methods used to carry out the demolition, as well as the proposed measures for protecting adjoining structures, property and pedestrians. A schedule of the demolition activities shall be developed as part of demolition planning. At a minimum, the plan shall include the following: 1. Details on the type of construction and condition of the structure(s) to be demolished, including photographs of the structure and the site that accurately depict its present condition. 2. Inspection details on the structural conditions of the adjoining properties. 3. Description of the means and methods for protection of adjoining or adjacent structures and public right-of-ways. Where required by the Building Code, a preconstruction survey complying with Section B-3307.9 and prepared by a licensed engineer shall be submitted. 4. Description of the method of demolition to be used. 5. Details on any potential hazards. 6. Underground utility confirmation number. 7. Description of any safety exposures and environmental issues. 8. In cases where the demolition requires Special Inspections in accordance with the Building Code, the site safety plan shall be approved by a professional engineer licensed by the Commonwealth of Pennsylvania. The plan shall include the name and address of the licensed engineer and shall be signed, sealed and dated by the engineer in accordance with the professional licensing laws. Submission of the plan by the demolition contractor constitutes agreement by the contractor to follow and carry out the plan. A-305.2.2.2 Site Plan. A site plan which includes the following information shall be submitted: 1. Identification of elements listed below with the distance between each element and the structure(s) to be demolished: (a) Property lines. (b) Location and widths of adjacent walkways, streets, and easements. (c) All existing buildings, including height, number of stories, and construction type. (d) Neighboring structures on adjacent lots, including height, number of stories, and construction type. (e) Location of utilities within the work area. (f) Trees, light and other utility poles, street furniture and other items of a height of 8 feet or more not considered structures located on adjacent lots or public right-of-ways potentially impacted by the demolition. (g) Location of all construction fences and sidewalk sheds around work site. 2. The extent of demolition, including underground removal. 3. Planned pedestrian protections. A-305.2.2.3 Demolition schedule. The contractor shall submit a schedule of the proposed demolition which shall include the following: 1. The start date that is consistent with code requirements for public notice. 2. Identification of demolition milestones and projected dates of completion. 3. The proposed start and stop times for daily activity. 4. Confirmation that the work will not begin before site safety measures are in place and those measures are inspected and approved by the code official. A-305.2.2.3.1 Revised demolition schedule. As soon as practicable, the contractor is required to submit to the Department a revised demolition schedule if the demolition does not start in the time frame established by the schedule submitted with the permit application. Failure to submit the revised demolition schedule shall be a Class II violation. A-305.2.2.4 Requisite approvals. The following approvals shall be required before a demolition permit may be issued: 1. Zoning permit for the demolition. 2. Plumbing permit for sealing of the building sewer at the curb trap. 3. Water service discontinuance permit from the Philadelphia Water Department. 4. Philadelphia Historical Commission approval for any buildings listed on the Philadelphia Register of Historic Places. 5. Philadelphia Water Department approval of stormwater management where the area of disturbance equals or exceeds 5,000 square feet. 6. Dust control permit and plan approved by the Department of Public Health for any a structure that exceeds 3 stories, 40 feet in height, or encompasses more than 10,000 square feet. 7. Philadelphia City Planning Commission approval is required per Title 14 of The Philadelphia Code. 8. A building permit for the construction, expansion, or alteration of a new or existing building is required per Title 14 of The Philadelphia Code. 9. Authorization of the owner of the property in the form of an affidavit or a signed statement to the effect that the proposed work is authorized by the owner. The Department is authorized to accept electronic confirmation of such authorization. A-305.2.2.5 Monitoring plan. A monitoring plan must be submitted where required by the Philadelphia Building Code. The plan must be prepared by a licensed professional engineer and specify scope of monitoring, frequency, and acceptable tolerances. A-305.2.2.6 Notification. Where required by the Building Code, proof of notification to the adjoining and adjacent property owner and resident must be submitted. A-305.2.3 Electrical permits. Specific requirements for electrical permits include the items or data included in A-305.2.3.1 through A-305.2.3.6. A-305.2.3.1 General. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of the applicable code and standard, and relevant laws, rules and regulations, as determined by the code official. The detail shall include but not be limited to the location and capacity of lighting facilities, electrically operated equipment and electrical circuits required for service equipment that is included in, or affected by, the scope of work covered by the permit. A-305.2.3.2 Penetrations. Construction documents shall indicate where penetrations will be made for electrical systems and shall indicate the materials and methods for maintaining required structural safety, fire- resistance rating and fireblocking. A-305.2.3.3 Load calculations. Where an addition or alteration is made to an existing electrical system, an electrical load calculation shall be prepared to determine if the existing electrical service has the capacity to serve the added load. A.305.2.3.4 Building permit. Information on the associated building permit for the project, where applicable. A-305.2.3.5 Fire alarms. Construction documents for fire alarm systems shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code, the applicable code and standard, and relevant laws, ordinances, rules and regulations, as determined by the code official. A-305.2.3.6 Requisite approvals. The following approvals of departments of the City of Philadelphia and/or the Commonwealth of Pennsylvania shall be required before an electrical permit may be issued: 1. Pennsylvania Department of Health. Pursuant to the UCC, Pennsylvania Department of Health approval is required for healthcare facilities. 2. Philadelphia Historical Commission. Philadelphia Historical Commission approval is required for the installation of solar and photovoltaic systems on properties listed on the Philadelphia Register of Historic Places, in accordance with Title 14 of The Philadelphia Code. A-305.2.4 Mechanical and fuel gas permits. Specific requirements for mechanical and fuel gas permits include the items or data set forth in A-305.2.4.1 through A-305.2.4.4. Other requirements for mechanical and fuel gas permit application construction documents are found in the appropriate Sections of the technical codes. A-305.2.4.1 General. The construction documents shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed and show in detail that the work will conform to the provisions of the mechanical and fuel gas codes and relevant laws, rules and regulations, as determined by the code official. A-305.2.4.2 Energy conservation. Supporting documentation shall be required to detail compliance with energy conservation requirements. A-305.2.4.3 Building permit. Information on the associated building permit for the project, where applicable. A-305.2.4.4 Requisite approvals. The following approvals of departments of the City of Philadelphia and/or the Commonwealth of Pennsylvania shall be required before a mechanical or fuel gas permit may be issued: 1. Philadelphia Streets Department. Philadelphia Streets Department approval is required for any encroachments, as per Title 11 of The Philadelphia Code. 2. Pennsylvania Department of Health. Pursuant to the UCC, Pennsylvania Department of Health approval is required for healthcare facilities. 3. Philadelphia Historical Commission. Philadelphia Historical Commission approval is required for the placement of any equipment on the exterior of properties listed on the Philadelphia Register of Historic Places, in accordance with Title 14 of The Philadelphia Code. 4. Philadelphia Department of Public Health approval is required for parking garage ventilation systems. A-305.2.5 Plumbing permits. Specific requirements for plumbing permits include the items or data set forth in A-305.2.5.1 through A-305.2.5.5. Other requirements for plumbing permit application construction documents are found in the appropriate Sections of the technical codes. A-305.2.5.1 General. The construction documents shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed and show in detail that the work will conform to the provisions of the Plumbing Code and relevant laws, rules and regulations, as determined by the code official. A-305.2.5.2 Backflow preventer assembly. Confirmation that the water supply is to be protected by a backflow preventer as required and approved by the Philadelphia Water Department. A-305.2.5.3 Site plan. In the case of multiple buildings or parcels, the site plan shall identify the water and sewer connections and pipe serving the structures within the site. The approved point of disposal for storm water management systems required by regulations of the Philadelphia Water Department shall be shown. A.305.2.5.4 Building permit. Information on the associated building permit for the project, where applicable. A-305.2.5.5 Requisite approvals. The following approvals of departments of the City of Philadelphia and/or the Commonwealth of Pennsylvania shall be required before a fire suppression permit may be issued: 1. Philadelphia Water Department. The approval of the Philadelphia Water Department is required for water and sewer connections. 2. Pennsylvania Department of Health. Pursuant to the UCC, Pennsylvania Department of Health approval is required for healthcare facilities. 3. Philadelphia Department of Public Health approval is required for plumbing connected to an on-lot sewage disposal system or private well and for food service facilities. A-305.2.6 Fire suppression permits. Specific requirements for building permits for fire suppression systems include the items or data set forth in A-305.2.6.1 through A-305.2.6.6. Other requirements for fire suppression permit application construction documents are found in the appropriate Sections of the technical codes and related standards. A-305.2.6.1 General. The construction documents shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed and show in detail that the work will conform to the provisions of the Building Code, related NFPA standards and relevant laws, rules and regulations, as determined by the code official. A-305.2.6.2 Hydraulic calculations. Submittal of hydraulic calculations as detailed by the appropriate NFPA standard to provide verifiable analysis of the water delivery and supply as it relates to the proposed fire suppression system. A-305.2.6.3 Backflow preventer assembly. Confirmation that the water supply is to be protected by a backflow preventer as required and approved by the Philadelphia Water Department. A-305.2.6.4 Site plan. In the case of multiple spaces, buildings or parcels, a site plan shall be submitted identifying the water connections and supply pipe to the uses and structures within the site. A-305.2.6.5 Building permit. Information on the associated building permit for the project, where applicable. A-305.2.6.6 Requisite approvals. The following approvals of departments of the City of Philadelphia and/or the Commonwealth of Pennsylvania shall be required before a fire suppression permit may be issued: 1. Philadelphia Water Department. The approval of the Philadelphia Water Department is required for water connections. 2. Pennsylvania Department of Health. Pursuant to the UCC, Pennsylvania Department of Health approval is required for healthcare facilities. 3. Philadelphia Historical Commission. Philadelphia Historical Commission approval is required for all work performed on properties listed on the Philadelphia Register of Historic Places, in accordance with Title 14 of The Philadelphia Code. 4. Philadelphia Fire Department. Philadelphia Fire Department approval is required for hydrants as per Subcode F of Title 4 of The Philadelphia Code. A-305.2.7 Excavation permits. Construction documents for a permit for excavation shall be submitted in accordance with Sections A-305.2.7.1 through A-305.2.7.4. Exception: Construction documents are not necessary for excavations incidental to a complete demolition of a structure which complies with the requirements of Section A-305.2.2. A-305.2.7.1 Excavation Plan. An excavation plan prepared by a licensed professional engineer which includes the following information shall be submitted: 1. Identification of elements listed below with the distance between each element and the excavation: (a) Property lines. (b) Location and widths of adjacent walkways, streets, and easements. (c) All existing buildings, including height, number of stories, and construction type. (d) Neighboring structures on adjacent lots, including height, number of stories, and construction type, within ten feet of the excavation. (e) Any foundation or retaining wall within ten feet of the excavation, including depth of footing. (f) Location of utilities within the work area. 2. The area and depth of excavation. 3. Required protections of footings and foundations of buildings and structures within ten feet of the excavation from settlement or lateral translation. (a) Where no special precautions are warranted, the licensed professional engineer shall provide a sealed statement that no special precautions or measures are required to protect existing footings and foundation on the subject property or on the immediately adjoining property. 4. Protective or support systems for immediately adjacent rights-of-way, alleys and yards of adjacent properties in accordance with the regulations of the United States Occupational Safety and Hazard Administration. 5. Damp-proofing of exposed foundation walls. 6. Size and location of construction barriers. 7. Underground utility confirmation number. A-305.2.7.2 Preconstruction Survey. A preconstruction survey documenting the existing conditions of all adjacent buildings and identifying any potential hazards prepared by a licensed professional engineer must be submitted. A-305.2.7.3 Requisite approvals. The following approvals shall be required before an excavation permit may be issued: 1. Philadelphia Streets Department approval is required as per Title 11 of The Philadelphia Code for any encroachments into the right-of-way. 2. Philadelphia Water Department approval of stormwater management where the area of disturbance equals or exceeds 5,000 square feet. A-305.2.7.4 Monitoring plan. A monitoring plan must be submitted where required by the Philadelphia Building Code. The plan must be prepared by a licensed professional engineer and specify scope of monitoring, frequency, and acceptable tolerances. A-305.3 Maintenance of construction documents. The prime contractor and/or owner must keep the approved set of construction documents on-site at all times and make the documents accessible for inspection upon demand of the code official. Failure to keep or make construction documents available on-site shall result in the issuance of a stop work order until the documents are produced and the Department determines that work can proceed safely. [History: Added, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] [History: Amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012.] [History: Amended and subsection 11 deleted, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] [History: Added, Bill No. 220008 (approved July 6, 2022), effective January 1, 2023.] [History: Added, Bill No. 220008 (approved July 6, 2022), effective January 1, 2023.] [History: Amended, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions. Amended, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023; amended, Bill No. 220008 (approved July 6, 2022), effective January 1, 2023.] [History: Added, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017.] [History: Amended, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017; amended, Bill No. 220008 (approved July 6, 2022), effective January 1, 2023..] [History: Added, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017.] [History: Amended, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017.] [History: Added, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017.] [History: Added, Bill No. 170091-A (approved April 17, 2017), effective May 22, 2017.] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 190866 (approved December 30, 2019).] [History: Added, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] [History: Added, Bill No. 220008 (approved July 6, 2022), effective January 1, 2023.] [History: Added, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 180175 (approved June 6, 2018).] SECTION A-306 COMMERCIAL CONSTRUCTION RECORDS A-306.1 Record retention. Pursuant to the UCC, the Department shall keep records of all applications received, permits issued, reviewed building plans and specifications, certificates issued, fees collected, reports of inspections, notices and orders issued for all commercial buildings and structures related to construction activities regulated under the Building Construction and Occupancy Code. The Department shall retain these records as long as the related structure remains in existence. [History: Added, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 180175 (approved June 6, 2018).] CHAPTER 4 INSPECTIONS SECTION A-401 RIGHT OF ENTRY A-401.1 Permit inspections: Pursuant to Section 5-1004 of the City Charter, the code official shall have the authority to enter at any reasonable time any structure or premises for which a permit has been issued to inspect for compliance with the permit, any construction documents pertinent thereto and the applicable provisions of this code and the technical codes. A-401.2 Existing premises: The code official shall have the authority to enter at any reasonable time any structure or premises to inspect, conduct investigations or survey: 1. To determine compliance with the provisions of this code or the technical codes applicable to the continuing occupancy of premises; 2. When there is reasonable cause to believe that a code violation exists; or 3. To ascertain and cause to be corrected any conditions liable to cause fire, contribute to the spread of fire, interfere with fire-fighting operations, endanger life or any violations of the provisions or intent of this code, the technical codes or any other ordinance affecting fire safety. A-401.2.1 Non-public spaces: Prior to entering into a space not otherwise open to the general public, the code official shall make a reasonable effort to locate the owner or other person having charge or control of the space or premises, present proper identification and request entry. Failure or refusal by the owner or other person in charge of the space or premises to permit such entry shall constitute a basis for the code official to apply to a court of competent jurisdiction for proper orders authorizing entry. A-401.2.2 Access by owner or operator: Every occupant of a structure or premises shall give the owner or operator thereof, or agent or employee, access to any part of such structure or premises at reasonable times for the purpose of making such inspection, maintenance, repairs or alterations as are necessary to comply with the provisions of this code and the technical codes and with any notice or orders issued pursuant thereto. [History: Amended, Bill No. 030780 (approved December 31, 2003).] SECTION A-402 PERMIT INSPECTIONS A-402.1 General: The code official shall conduct inspections as provided in this Section and the technical codes. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code, the technical codes, or of other ordinances. Inspections presuming to give authority to violate or cancel the provisions of The Philadelphia Code shall not be valid. It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes until approved. Neither the code official nor the City of Philadelphia shall be liable for expense entailed in the removal or replacement of any material to allow inspection. A-402.1.1 Concealed work. Where any installation subject to inspection prior to use is covered or concealed without having first been inspected, the code official shall have the authority to require that such work be exposed for inspection. A-402.2 Preliminary inspection: Before issuing a permit, the code official is authorized to examine or cause to be examined buildings, structures and sites for which an application has been filed. A-402.3 Record: A record of all inspections and violations of this code or the technical codes shall be maintained by the code official. A-402.4 Special inspections: The owner shall provide for special inspections in accordance with the Building Code, departmental procedures and Section 9-1306. A-402.5 Final inspection: Upon completion of the work authorized by the permit and before issuance of the certificate of occupancy or final approval, a final inspection shall be made. All violations of the permit and approved construction documents shall be noted and the holder of the permit shall be notified of the violations. A re- inspection shall be conducted to confirm compliance with all such violations prior to issuance of the certificate of occupancy or final approval. The final inspection shall be performed by persons who are certified in accordance with the regulations of the Commonwealth of Pennsylvania in the categories appropriate for the scope of work to be inspected. Where the permit holder does not provide for a final inspection, the permit shall become invalid and appropriate code violations shall be issued. A-402.6 Approved inspection agencies: The Department is authorized to accept reports of approved inspection agencies provided such agencies satisfy the Department's requirements, including those established in Chapter 9-1300 of The Philadelphia Code, as to qualifications and reliability. A-402.7 Plant inspection: Where required by the provisions of the technical codes or regulations, materials or assemblies shall be inspected at the point of manufacture or fabrication in accordance with applicable provisions of the technical codes and Department procedures by a Special Inspector or Special Inspection Agency registered pursuant to Section 9-1306 of The Philadelphia Code. A-402.8 Inspection requests: It shall be the duty of the holder of the permit or their duly authorized agent to notify the code official when work is ready for inspection. It shall be the duty of the permit holder and contractor to provide access to and means for inspection of such work for any inspections that are required by this code or the technical codes. A-402.8.1 Notice of start: The permit holder, or their authorized designee, shall notify the code official or inspection agency having jurisdiction not less than twenty-four (24) hours and not more than fourteen (14) calendar days prior to the start of work authorized under a permit. If work does not commence within fourteen (14) days following the initial notice, the permit holder shall notify the code official or inspection agency of the delay and provide an updated anticipated start date. A-402.8.1.1 Definition: start of work. For the purposes of this code, the start of work shall be defined as the initiation of any construction, alteration, or other activity explicitly authorized by the issued construction permit. This includes any physical work that falls within the permitted scope of construction, alteration, or installation covered under the permit. A-402.8.1.1.1 Activities solely associated with site preparation shall not constitute the start of work. This includes but is not limited to the installation of site safety protections; grading, clearing, or other preparatory activities that are exempt from permitting; and the installation of erosion and sediment control measures or other environmental protections. A-402.8.1.1.2 When grading, clearing, or other preparatory work requires a permit and such work is specifically included within the scope of an issued building permit, the commencement of that permitted preparatory activity shall be considered the start of work for the purposes of this section. A-402.8.1.2 Initial inspection. Prior to the start of work, the code official or inspection agency having jurisdiction may conduct an initial inspection to verify that all required site safety protections, erosion and sediment controls, and other required preparatory measures are properly installed and maintained. A-402.9 Approval required: Work shall not be done nor concealed beyond the point indicated in each successive inspection without first obtaining the approval of the code official. The code official, upon notification, shall make the requested inspections and shall either indicate the portion of the construction that is satisfactory as completed, or shall notify the permit holder or an agent of the permit holder wherein the same fails to comply with the code. Any portions that do not comply shall be corrected and such portion shall not be covered or concealed until authorized by the code official. A-402.10 Required inspections. Required inspections shall include the following items as they relate to the technical codes. The Department is authorized to conduct additional inspections as determined by conditions and the scope of work authorized by the permit. The permit holder and contractor shall be responsible for the scheduling of such inspections. The contractor shall be responsible for ensuring that the required inspections are approved before proceeding. A-402.10.1 Building permits. Building permit inspections include the inspections of construction site and building location, footings and foundations, wood and steel framing and connections, masonry construction, precast and cast-in-place concrete, exterior weather boarding, fire-stopping and draft-stopping, building components related to life safety and fire protection systems and building components related to size, installation and workmanship. Specific building permit inspections include the items included in A-402.10.1.1 through A-402.10.1.10 as applicable to the scope of work authorized by the permit. A-402.10.1.1 Footing and foundation inspection. Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place prior to inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94, the concrete need not be on the job. Required waterproofing or dampproofing shall be installed prior to backfilling. A-402.10.1.2 Concrete slab or under-floor inspection. Concrete slab and under-floor inspections shall be made after in-slab or under-floor reinforcing steel and building service equipment, conduit, piping accessories and other ancillary equipment items are in place, but before any concrete is placed or floor sheathing installed, including subfloor. A-402.10.1.3 Lowest floor elevation. In flood hazard areas, upon placement of the lowest floor, including the basement, and prior to further vertical construction, the elevation certification or dry floodproofing certification required by the Building or Residential Code shall be submitted to the code official. A-402.10.1.4 Frame inspection. Framing and masonry construction inspections shall be made after the roof deck or sheathing, all interior and exterior framing, fire blocking and bracing are in place and pipes, chimneys and vents to be concealed are complete and the rough electrical, plumbing, heating wires, pipes and ducts have been approved. A-402.10.1.5 Wall board inspection. Wall board inspections shall be made after wall covering, interior and exterior, is in place, but before any finish material is applied or gypsum board joints and fasteners are taped and finished. Exception: Gypsum board that is not part of a fire-resistive assembly or a shear assembly. A-402.10.1.6 Fire-resistant and smoke-resistant penetrations. Protection of joints and penetrations in fire-resistance-rated assemblies, smoke barriers and smoke partitions shall not be concealed from view until inspected and approved. A-402.10.1.7 Energy efficiency inspections. Inspections shall be made to determine compliance with the Energy Conservation Code and shall include, but not be limited to, inspections for: envelope insulation R and U values, fenestration U value, duct system R value, and HVAC and water heating equipment efficiency. A-402.10.1.8 Accessibility inspections. Inspections shall be made of building sites and all interior building components to verify compliance with required accessibility standards. A-402.10.1.9 Other inspections. In addition to the inspections specified above, the code official is authorized to make or require other inspections of any construction work to ascertain compliance with the provisions of this code and other laws that are enforced by the Department. A-402.10.1.10 Special Inspections. For special inspections, see Chapter 17 of the Building Code. A-402.10.2 Plumbing permits. The code official shall make the following inspections and such other inspections as necessary, and shall either release that portion of the construction or shall notify the permit holder, designated agent or Registered Master Plumber of any violations that must be corrected. 1. Underground inspection shall be made after trenches or ditches are excavated and bedded, piping installed, and before any backfill is put in place. 2. Rough-in inspection shall be made after the roof, framing, fireblocking, firestopping, draftstopping and bracing is in place and all sanitary, storm and water distribution piping is roughed-in, and prior to the installation of wall or ceiling membranes. 3. Final inspection shall be made after the building is complete, all plumbing fixtures are in place and properly connected, and the structure is ready for occupancy. A-402.10.3 Fuel gas and mechanical permits. The code official, upon notification from the permit holder or the permit holder's agent, shall make the following inspections as applicable to the scope of work, and other such inspections as necessary, and shall either release that portion of the construction or notify the permit holder or the permit holder's agent of violations that are required to be corrected. 1. Underground inspection shall be made after trenches or ditches are excavated and bedded, piping is installed and before backfill is put in place. When excavated soil contains rocks, broken concrete, frozen chunks and other rubble that would damage or break the piping or cause corrosive action, clean backfill shall be on the job site. Exception: Ground-source heat pump loop systems tested in accordance with Section 1210.10 of the Mechanical Code shall be permitted to be backfilled prior to inspection. 2. Rough-in inspection shall be made, after the roof, framing, fireblocking and bracing are in place, of all piping and ducting before fixtures or appliances are set or installed, and all components to be concealed are complete, and prior to the installation of wall or ceiling membranes. 3. Final inspection shall be made upon completion of the installation. The requirements of this Section shall not be considered to prohibit the operation of any heating equipment or appliances installed to replace existing heating equipment or appliances serving an occupied portion of a structure provided that a request for inspection of such heating equipment or appliances has been filed with the department not more than 48 hours after such replacement work is completed, and before any portion of such equipment or appliances is concealed by any permanent portion of the structure. A-402.10.4 Electrical permits. The inspections required for electrical permits shall include the following inspections as applicable to the scope of work, and other such inspections as necessary, and shall either release that portion of the construction or notify the permit holder or the permit holder's agent of violations that are required to be corrected. The licensed electrical contractor shall be responsible for the scheduling of such inspections. 1. A rough-in inspection is required before any wiring is concealed by insulation, wall covering, ceiling covering, trench backfill, etc. If conditions require partial coverage of the permitted electrical work, permission shall be requested of and received from the department or electrical inspector having jurisdiction prior to coverage or concealment. 2. A final inspection is required when all equipment and appliances are installed, grounded, and energized, including low voltage and data wiring systems. A-402.10.5 Residential permits. For onsite construction, from time to time the code official, upon notification from the permit holder or the permit holder's agent, shall make or cause to be made any necessary inspections and shall either approve that portion of the construction as completed or shall notify the permit holder or the permit holder's agent wherein the same fails to comply with the code. Specific required inspections include those in Sections A-402.10.5.1 through A-402.10.5.5.1 as applicable to the scope of work. A-402.10.5.1 Foundation inspection. Inspection of the foundation shall be made after poles or piers are set or trenches or basement areas are excavated and any required forms erected and any required reinforcing steel is in place and prior to the placing of concrete. The foundation inspection shall include excavations for thickened slabs intended for the support of bearing walls, partitions, structural supports, or equipment and special requirements for wood foundations. A-402.10.5.2 Plumbing, mechanical, gas and electrical systems inspection. Rough inspection of plumbing, mechanical, gas and electrical systems shall be made prior to covering or concealment, before fixtures or appliances are set or installed, and prior to framing inspection. Exception: Ground-source heat pump loop systems tested in accordance with Section M2105.28 of the Residential Code shall be permitted to be backfilled prior to inspection. A-402.10.5.3 Floodplain inspections. For construction in areas prone to flooding as established by Table R-R301.2(1) of the Residential Code, upon placement of the lowest floor, including basement, and prior to further vertical construction, the code official shall require submission of documentation, prepared and sealed by a registered design professional, of the elevation of the lowest floor, including basement, required in the Residential Code. A-402.10.5.4 Frame and masonry inspection. Inspection of framing and masonry construction shall be made after the roof, masonry, all framing, firestopping, draftstopping and bracing are in place and after the plumbing, mechanical and electrical rough inspections are approved. A-402.10.5.5 Other inspections. In addition to the called inspections above, the code official may make or require any other inspections to ascertain compliance with the Residential Code and other laws, rules and regulations enforced by the code official. A-402.10.5.5.1 Fire-resistance-rated construction inspection. Where fire-resistance-rated construction is required between dwelling units or due to location on property, the code official shall require an inspection of such construction after all lathing and/or wallboard is in place, but before any plaster is applied, or before wallboard joints and fasteners are taped and finished. A-402.10.6 Demolition permits. Specific demolition permit inspections are included in Sections A-402.10.6.1 through A-402.10.6.5, as applicable to the scope of work. A-402.10.6.1 Initial site safety inspection. The contractor shall schedule an initial inspection with the Department a minimum of 48 hours prior to the start of work. During the initial on-site inspection, the contractor shall be present and conduct a review of the site safety demolition plan with the code official prior to the start of any demolition activity. The contractor shall provide the code official with proof of all utility disconnections. Pedestrian protection required by the Building Code must be in place before the start of work. If adequate pedestrian protection is not in place and any work has commenced, the Department shall issue a Stop Work order which will remain in effect until the necessary pedestrian protections are put in place, inspected and approved by a code official. A-402.10.6.2 Demolition progression inspection. An inspection is required to ensure that the contractor is maintaining all safety measures detailed in the site safety demolition plan and using the means and methods detailed in the plan in a safe and workmanlike manner. A review of the submitted schedule shall be performed on- site by the code official. An inspection shall be required for each floor of the building being demolished. When necessary, an additional inspection may be required to ensure proper drainage of the cellar cavity has been achieved by breaking up the cellar floor. A-402.10.6.3 Adjacent wall inspection. An inspection is required to ensure that any adjacent foundation walls have been properly treated prior to backfilling of any areas below the finished grade. Additionally, the code official shall confirm that the contractor has completed the closing of all openings in any exposed party walls prior to finished treatment. A-402.10.6.4 Pre-final inspection. The pre-final inspection is required to ensure that all improper fill has been removed from the site prior to the backfilling of the cellar cavity and that clean fill is provided. A-402.10.6.5 Final inspection. A final inspection is required to determine compliance of the permitted demolition, and when necessary, to confirm proper grading of the site has been achieved upon completion of the demolition. A-402.10.7 Fire Suppression permits. The code official, upon notification from the permit holder or the permit holder's agent, shall make the following inspections as applicable to the scope of work, and other such inspections as necessary, and shall either release that portion of the construction or notify the permit holder or the permit holder's agent of violations that are required to be corrected. 1. Underground inspection shall be made after trenches or ditches are excavated and bedded, piping is installed and before backfill is put in place. When excavated soil contains rocks, broken concrete, frozen chunks and other rubble that would damage or break the piping or cause corrosive action, clean backfill shall be on the job site. 2. Rough-in inspection shall be made of all components prior to the installation of wall or ceiling membranes. 3. Final inspection shall be made upon completion of the installation. The licensed fire suppression company shall provide documentation of final testing and approval of the systems in compliance with the technical codes and referenced standards. A-402.11 Other inspections. In addition to the required inspections specified in A-402.10, the code official is authorized to make or require other inspections of any construction work to ascertain compliance with the provisions of this code, the technical codes and provisions of other codes enforced by the Department. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 180175 (approved June 6, 2018).] SECTION A-403 COORDINATION OF INSPECTIONS A-403.1 Multiple responsibility: Whenever in the enforcement of this code or another code or ordinance, the responsibility of more than one official or department is involved, it shall be the duty of the officials involved to coordinate their inspections and administrative orders as fully as practicable so that the owners and occupants of the premises shall not be subjected to visits by numerous inspectors or multiple or conflicting orders. Whenever an inspector from any agency or department observes an apparent or actual violation of some provision of a law, ordinance or code not within the inspector's authority to enforce, the inspector shall report the findings to the code official having jurisdiction. A department shall not, however, delay the issuance of any emergency orders. A-403.2 Jurisdictional cooperation: The assistance and cooperation of Licenses and Inspections, Fire, Police, Health and all other officials shall be available as required in the performance of duties. SECTION A-404 SERVICE UTILITIES A-404.1 Connection of service utilities. No person shall make connections from a utility, source of energy, fuel or power to any building or system that is regulated by this code or the technical codes for which a permit is required, until released by the code official. A-404.2 Temporary connection. The building official shall have the authority to authorize the temporary connection of the building or system to the utility source of energy, fuel or power. A-404.3 Authority to disconnect service utilities. The code official shall have the authority to authorize disconnection of utility services or energy sources to a building, structure or system regulated by the Philadelphia Building Construction and Occupancy Code where it is necessary to eliminate an immediate hazard to life or property. The code official shall notify the serving utility, and wherever possible, the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure or service system shall be notified in writing as soon as practical thereafter. A-404.3.1 Connection after order to disconnect. A person shall not make utility service or energy source connections to systems regulated by the Philadelphia Building Construction and Occupancy Code, which have been disconnected or ordered to be disconnected by the code official, or the use of which has been ordered to be discontinued by the code official until the code official authorizes the reconnection and use of such systems. [History: Added, Bill No. 030780 (approved December 31, 2003).] SECTION A-405 IDENTIFICATION A-405.1 Credentials: The department's employees shall carry proper identification when inspecting structures or premises in the official performance of their duties under this code and the technical codes. CHAPTER 5 VIOLATIONS SECTION A-501 GENERAL A-501.1 Unlawful acts: It shall be unlawful for any person, firm or corporation to erect, construct, alter, extend, repair, remove, demolish, maintain, fail to maintain, provide, fail to provide, occupy, let to another to occupy or permit another person to occupy any structure or equipment regulated by this code or the technical codes, or cause same to be done, contrary to or in conflict with or in violation of any of the provisions of this code or the technical codes, or to fail to obey a lawful order of the code official, or to remove or deface a placard or notice posted under the provisions of this code or the technical codes. SECTION A-502 NOTICES AND ORDERS A-502.1 Notice of violation: Whenever the code official observes an apparent or actual violation of a provision of this code or the technical codes or of a permit, certificate or construction document issued thereunder, the code official shall prepare a written notice of violation describing the condition of violation and specifying time limitations not to exceed 35 days for the required correction, discontinuance of illegal action or condition, repairs, improvements or abatement of violation. Where the code official determines that a condition exists which creates a hazard to life or property requiring immediate action, an immediate oral order to repair or otherwise immediately remove the hazard shall have the full effect of the required subsequent written notice of violation. A-502.2 Form: The written notice prescribed in Section A-502.1 shall: 1. Include the address of the premises in violation; 2. Include a description of the violation(s); 3. Include a correction order to eliminate the violation(s); and 4. Include a time limitation for correction of the violation(s). A-502.3 Service of notice: The written notice of violation shall be served upon the owner, owner's agent, occupant or other person responsible for the erection, construction, installation, alteration, extension, repair, removal, demolition, operation or occupancy of a building, structure, equipment or system under violation. If such person is not the owner of the premises where the violation is deemed to exist or to have occurred, a copy of the notice shall be sent by first class mail to the last registered owner of the premises. The failure of the code official to serve any person required herein to be served shall not invalidate any proceedings hereunder as to any other person duly served or relieve any such person from any duty or obligation imposed by the provisions of this code or the technical codes. A-502.4 Method of service: A notice of violation shall be deemed to be properly served if a copy thereof is delivered to such persons prescribed in Section A-502.3 by one or more of the following: 1. Personally; 2. By first class mail to the last known residence or business address; 3. By certified or registered mail to the last known residence or business address, return receipt requested; 4. By leaving it in the possession of an adult member of the person's family; 5. By leaving it in the possession of an adult in charge of the premises or persons place of business; or 6. If no address is known or the mail is returned indicating no delivery, a copy of the notice shall be posted in a conspicuous place at the entrance or avenue of access to the premises in violation and such procedure shall be deemed the equivalent of personal notice. A-502.5 Date of service: The date of service shall be the date of personal service, the date of posting, or the date of mailing by first class, registered or certified mail. [History: Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 030780 (approved December 31, 2003).] SECTION A-503 PROSECUTION A-503.1 Failure to correct: After the expiration of the time for compliance as stated on the notice of violation, a reinspection or reinvestigation shall be made by the code official to determine compliance. If the violation has not been corrected and no appeal is pending, the code official shall institute the appropriate legal proceedings to apply penalties as provided for in this code or for the purpose of ordering the responsible person: 1. To restrain, correct or remove the violation or refrain from any further execution of work; 2. To restrain or correct the erection, construction, conversion, installation, maintenance, repair or alteration of the structure in violation; 3. To require the removal of work in violation; or 4. To prevent the use or occupancy of the premises or structure that is not in compliance with the provisions of this code or the technical codes. A-503.1.1 Immediate hazard: Notwithstanding the provisions of Section A-503.1, nothing shall prevent the code official from instituting appropriate remedies to protect occupants or the public from conditions which pose an immediate threat to health or safety. A-503.2 Abatement of violation: Whenever any violation of this code or the technical codes or any order issued pursuant thereto is not corrected, the department, in addition to invoking any other sanction or penalty shall be authorized to, itself or by contract, correct the violation, charge the costs (including administrative costs) thereof to the violator, and with the approval of the Law Department collect the costs by lien or otherwise. Repeat violations of the Property Maintenance Code, requiring more than one such abatement of violation on the same property in a twelve-month period, may be assessed an additional penalty pursuant to subsection 1. of Section A-601.1. A-503.2.1 Vacant lots: Where a vacant lot is enclosed by fencing and secured by a lock that prevents the code official from entering upon the lot for the purpose of correcting a violation, the code official may gain access to the lot by all legal means, including obtaining an administrative warrant. [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 130721 (approved January 8, 2014); amended, Bill No. 180521 (approved June 28, 2018).] [History: Enrolled bill read "...pursuant to § A-601.1.1."] [History: Added, Bill No. 130721 (approved January 8, 2014); renumbered and former Section A-503.2.1 deleted, Bill No. 180175 (approved June 6, 2018).] SECTION A-504 STOP WORK ORDER A-504.1 General: The Department and, to the extent permitted under the PA Construction Code Act and Uniform Construction Code, any Philadelphia Fire Department Battalion Chief is authorized to issue Stop Work Orders directing that erection, construction, alterations, installation, repairs, removal, demolition and other activities cease immediately and that the premises be vacated pending compliance with such orders whenever: 1. Any structure or part thereof, including any adjoining or abutting structures, is found to be in a dangerous or unsafe condition due to inadequate maintenance, deterioration, damage by natural causes, fire, or faulty construction that it is likely to cause imminent injury to persons or property. 2. Any erection, construction, alterations, installation, repairs, removal, demolition or other activity is being performed in or on any structure or premises, or part thereof, contrary to accepted construction practices or in a dangerous or unsafe manner which imperils life, safety or property, constitutes a fire or health hazard, or will interfere with a required inspection. 3. Any erection, construction, alterations, installation, repairs, removal, demolition or other activity is being performed in or on any structure or premises, or any part thereof, without required permits. 4. In cases of demolition activity, there is a failure to provide for a site safety review as required by Chapter 4 of this Code. Upon the issuance of a stop work order under this subsection, the work shall be stopped for a minimum of three (3) business days. The Department shall take any other appropriate actions necessary, including revoking any permits, and shall not allow work to begin until the code official is satisfied that the demolition will proceed in a safe manner. 5. A contractor is found performing construction without a license required by Chapter 9-1000. A-504.2 Orders by the Department: The Stop Work Order shall be in writing and shall describe the nature of the dangerous or unsafe condition, the manner of correction and the conditions under which work can be resumed. Where the department observes a condition which creates a hazard to life or property requiring immediate action, an immediate oral order shall have the full effect of the subsequent written order. A-504.3 Service: The Stop Work Order shall be served on the person from whom action, forbearance or compliance is required and the owner of the premises. Upon notice of the Stop Work Order, all work shall stop immediately and the premises shall be vacated and closed to the public until there has been compliance with the terms of the Stop Work Order. A-504.4 Posting: The Stop Work Order shall be posted at every entrance to the premises in conspicuous places clearly visible to the public. The Stop Work Order shall remain posted on the premises until the required repairs have been made, the dangerous and unsafe conditions eliminated and required permits obtained. A-504.5 Police assistance: The department shall promptly notify the Police of the issuance of every Stop Work Order. The Police, upon the request of the department, shall render assistance in the enforcement of any Stop Work Order and shall have the right to enter the premises for such purpose and to arrest anyone violating any Stop Work Order as provided in this Section. A-504.6 Permit revocation: The department, in addition to issuing a Stop Work Order, shall have the option to revoke any permits which have been previously issued. Revoked permits shall not be reinstated except upon compliance with the terms of the Stop Work Order and payment of required fees. A-504.7 Prohibited conduct: It shall be a violation of this Section for any person with knowledge of a Stop Work Order to: 1. Continue any work in or about any structure or premises, or part thereof, after a Stop Work Order has been issued, except work required to correct the dangerous or unsafe conditions described in the Stop Work Order; 2. Enter any structure or premises, or part thereof, on which a Stop Work Order has been posted, except for the purpose of correcting the dangerous or unsafe conditions described in the Stop Work Order; 3. Permit any structure or premises, or part thereof, to be occupied by the public until the Stop Work Order has been lifted by the department; 4. Remove, damage, alter or deface any Stop Work Order; 5. Resist or interfere with any inspector or other official in the performance of their duties or the enforcement of any provision of this Section. A-504.8 Penalties: Notwithstanding the provisions of Chapter 6 of this code, a violation of this Section shall be punishable as follows: 1. Any person in violation of this Section shall have committed a Class III offense and be subject to the fines set forth in subsection 1-109(3) of The Philadelphia Code for each offense. 2. Each day of violation shall constitute a separate offense for which the violator is subject to fine. [History: Amended, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 041079 (approved May 12, 2005); amended, Bill No. 250708 (approved January 7, 2026) .] SECTION A-505 CEASE OPERATIONS ORDER A-505.1 General: The department and the Fire Department are authorized to issue Cease Operations Orders directing that use and other activities cease immediately and that the premises be vacated pending compliance with such orders whenever: 1. Any occupancy, use or other activity is being performed in or on any building, structure or land, or any part thereof, without required Zoning and/or Use Registration permits, Certificate of Occupancy or other permits; 2. There is actual or potential danger to the building occupants or those in the proximity of any structure or premises because of explosives, explosive fumes or vapors or the presence of toxic fumes, gases or materials, or operation of defective or dangerous equipment; 3. Any structure or part thereof is found to be in a dangerous or unsafe condition due to inadequate maintenance, deterioration, damage by natural causes, fire or faulty construction that it is likely to cause imminent injury to persons or property. 4. Any condition is observed which presents an immediate danger to life or property, including any danger to life or property of adjoining or abutting structures. 5. Any unsafe or unsanitary condition is observed which presents an immediate danger to the health of the occupants of any abutting premises due to the presence of raw sewage, garbage, rubbish or infestation. A-505.2 Orders: The Cease Operations Order shall be in writing and shall describe the occupancy, use or other activity that is being performed without required permits or certificates or which presents a danger, the manner of correction and the conditions under which occupancy, use or other activity can be resumed. If the code official observes a condition which requires immediate action, an immediate oral order shall have the full effect of the subsequent written order. A-505.3 Service: The Cease Operations Order shall be served on the person from whom action, forbearance or compliance is required and the owner of the premises. Upon notice of the Cease Operations Order all occupancy, use or other activity shall stop immediately and the premises shall be vacated of all employees, patrons and occupants until there has been compliance with the terms of the Cease Operations Order. A-505.4 Posting: The Cease Operations Order shall be posted at every entrance to the premises in conspicuous places clearly visible to the public. The Cease Operations Order shall remain posted on the premises until removal by, or with the approval of, the code official upon compliance with its terms. A-505.5 Additional violations upon reinspection: If upon reinspection, the code official discovers additional violations which present an immediate danger to life or property, a new Cease Operations Order shall be issued which shall include the additional violations as well as the previously stated violations which are not in compliance. A-505.6 Police assistance: The code official shall promptly notify the Police of the issuance of every Cease Operations Order. The Police, upon the request of the code official, shall render assistance in the enforcement of any Cease Operations Order and shall have the right to enter the premises for such purpose and to arrest anyone violating any Cease Operations Order as provided in this Section. A-505.7 Permit revocation: The department, in addition to issuing a Cease Operations Order, shall have the option to revoke any permits which have been previously issued. Revoked permits shall not be reinstated except upon compliance with the terms of the Cease Operations Order and payment of required fees. A-505.8 Prohibited conduct: No person with knowledge of a Cease Operations Order shall: 1. Continue any occupancy, use or other activity in or about any structure or land or part thereof after a Cease Operations Order has been issued, except work required to comply with the Cease Operations Order; 2. Enter any structure or land, or part thereof on which a Cease Operations Order has been posted, except for the purpose of complying with the Cease Operations Order; 3. Permit any structure or land, or part thereof to be occupied by the public until the Cease Operations Order has been lifted by the code official; 4. Remove, damage, alter or deface any Cease Operations Order; 5. Resist or interfere with any inspector or other official in the performance of their duties or the enforcement of any provision of this Section. 6. Refuse to leave, interfere with the evacuation of other occupants or continue any operation after having been given an evacuation order except such work as that person is directed to perform to remove a violation or unsafe condition. A-505.9 Penalties: Notwithstanding the provisions of Chapter 6 of this code, a violation of this Section shall be punishable as follows: 1. Any person in violation of this Section shall be subject to the fines set forth in subsection 1-109(3) of The Philadelphia Code for each offense. 2. Each day of violation shall constitute a separate offense for which the violator is subject to fine. A-505.10 Notice to Tenant: The Department shall provide a Notice of Intent to Cease Operations to each tenant of a residential rental property at least ten (10) days before issuing a Cease Operations Order on that property, provided that such notice is feasible in the interests of health and safety. 1. If the Department has established an Anti-Displacement Fund, the Notice shall include information explaining that tenants displaced due to a Cease Operations Order may be eligible for relocation assistance from the Anti-Displacement Fund. 2. The Notice shall include information explaining that tenants are protected from retaliation and harassment pursuant to Section 9-804 of the Philadelphia Code. [History: Amended, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 980646 (approved December 30, 1998).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 041079 (approved May 12, 2005); amended, Bill No. 250708 (approved January 7, 2026).] [History: Added, Bill No. 250331 (became law September 11, 2025), effective December 10, 2025.] SECTION A-506 CODE VIOLATION NOTICES (CVN) A-506.1 General. The code official is authorized to issue code violation notices for any violation of any provision of this code or the technical codes, pursuant to the procedures set forth in Section 1-112 of The Philadelphia Code. A-506.2 Remittance amount. The amount required to be remitted in response to a code violation notice is the amount indicated in Section 1-112 of The Philadelphia Code unless otherwise specified. Exceptions: The amount required to be remitted shall be as follows for violation of the following provisions: 1. Section F-1104.28 (door operations). . . . . One hundred dollars ($100) 2. Section F-1032 (egress maintenance). . . . . One hundred dollars ($100) 3. Section F-401.3 (notice of fire or fire alarm). . . . . Three hundred dollars ($300) 4. Section F-1004.1 (exceeding the lawful occupancy). . . . . One hundred dollars ($100) 5. Section 9-3901(3) (notification of license changes). . . . . Seventy-five dollars ($75) 6. Section 9-3907 (managing agents and property managers). . . . . One hundred fifty dollars ($150) 7. Section PM-902 (Foreclosed Vacant Residential Properties). . . . . Three hundred dollars ($300) 8. Section A-504.7 (Prohibited conduct during a Stop Work Order). . . . . Five hundred dollars ($500) 9. Section A-402.10.6 (Failure to provide for required demolition inspections). . . . . Five hundred dollars ($500) 10. Section PM-904 (Chronic Non-Compliant Owner). . . . . One hundred fifty dollars ($150) A-506.3 Licensed Contractors. The Department is authorized to deny the issuance of permits to any contractor licensed pursuant to The Philadelphia Code or licensed or registered by the Commonwealth of Pennsylvania who has been issued more than three (3) code violation notices and has either failed to remit the required amount of the code violation notice, or failed to appeal the issuance of the code violation notice. Such limitation shall remain in place until the contractor has remitted the required amounts or presented confirmation of an appeal. [History: Added, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 040998 (approved January 25, 2005); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added, Bill No. 090834 (approved April 28, 2010); amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added, Bill No. 100749 (approved January 26, 2011), effective April 26, 2011; amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 160365-A (approved October 19, 2016).] [History: Added, Bill No. 180175 (approved June 6, 2018).] CHAPTER 6 PENALTIES SECTION A-601 FINES A-601.1 Basic Fines: Any person who violates any provision of this code or the technical codes or regulations adopted thereunder; or who fails to comply with any order issued pursuant to any Section thereof; or who erects, constructs, installs, removes, alters or repairs a structure, equipment or system in violation of the approved construction documents or directive of the code official or of a permit or certificate issued under the provisions of this code or the technical codes, shall be subject to a fine of three hundred dollars ($300) for each offense. 1. In addition to the Basic Fine, repeat violations of Section PM-301 ("General") or Section PM-302 ("Exterior Property Areas"), requiring more than one abatement of the same property in a twelve-month period, shall be subject to a penalty of one hundred dollars ($100) for each such repeat abatement action. A-601.2 Fines for Class II offenses: Notwithstanding Section A-601.1, any person who violates any of the following provisions shall have committed a Class II offense and be subject to the maximum fine set forth in subsection 1-109(2) of The Philadelphia Code: 1. Section F-106.5 (Rendering equipment inoperable); 2. Section F-106.5.1 (Fire Department notification); 3. Section F-106.5.1 (Obstructing operations); 4. Section F-106.8 (Obstructions); 5. Section F-307 (Open Burning and Recreational Fires); 6. Section F-308 (Open-flame devices); 7. Section F-901.8 (Changes to fire protection equipment); 8. Section F-901.7 (Systems out of service); 9. Section F-106.2 (Periodic Testing Of Fire Protection Systems); 10. Section F-1032 (Maintenance of the Means of Egress); 11. Section PM-702 (Means of Egress); 12. Section PM-902 (Foreclosed Vacant Residential Properties); 13. Section PM-904 (Chronic Non-Compliant Owner); 14. Section PM-703 (Fire Resistance Ratings); 15. Section PM-704 (Fire Protection Systems); and 16. Section PM-804.2 (Historic Area Standards). A-601.3 Fines for Class III offenses: Notwithstanding Section A-601.1, any person who violates any of the following provisions shall have committed a Class III offense and shall be subject to the maximum fine set forth in subsection 1-109(3) of The Philadelphia Code: 1. Section A-301.1.5 (Zoning and Use Registration Permits); 1.1. Section A-402.10.6 (Failure to provide for required demolition inspections); 2. Section A-701 (Certificate of Occupancy); 2.1. Section B-1705.1.1.1 (Special Inspections of Special Cases); 3. Section B-3301.1 (Safeguards During Construction); 4. Section F-103 (Unsafe Conditions); 5. Section F-105.7.1 (Transportation of Explosives); 6. Section F-106.7 (Overcrowding); 7. Section F-105.7.1 (Explosives); 7.1 Section F-1104.16 (Fire Escapes); 8. Section F-5003.3 (Release of Hazardous Materials); 9. Section F-5601.1.3 (Fireworks); 10. Section PM-302.3 (Sidewalks and Driveways); 11. Section PM-314 (Piers and Other Waterfront Structures); 12. Reserved; 13. Section PM-109 (Unfit Structures); Section PM-108 (Unsafe Structures and Equipment); Exception: Violations of Section PM-108.1.3 (Unsafe shared retaining walls) shall be subject to the Basic Fines set forth in subsection A-601.1 of The Philadelphia Code. 14. Section PM-110 (Imminently Dangerous Structures); Exception: Violations of Section PM-110.1.1 (Imminently dangerous shared retaining wall) shall be subject to the Basic Fines set forth in subsection A-601.1 of The Philadelphia Code. 15. Reserved; 16. Section PM-315 (Periodic Inspection of Exterior Walls and Appurtenances of Buildings). 17. Section 14-906 (Market Street East Sign Regulations ). 18. Section PM-902.1; Sections PM-902.3 through 902.8. A-601.4 Separate offense: Each day that a violation continues after issuance of a notice or order shall be deemed a separate offense. A-601.5 Accrual of fines: Each day that a violation continues after the time for correcting the violation as stated in the initial notice of violation has passed, and where no timely appeal has been filed pursuant to Section A-801 or Section A-803, shall be deemed a separate offense for purposes of determining the accrual of fines. A-601.6 Imposition and accrual of fines: If no timely appeal is filed from the issuance of a violation notice issued under this Section, the applicable fines set forth for such violation in this Section shall be deemed imposed for purposes of Section A-202.7 and Section A-503.1; all fines so imposed shall continue to accrue for each separate offense of each violation. [History: Caption amended, Bill No. 041079 (approved May 12, 2005); amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 180521 (approved June 28, 2018).] [History: Added, Bill No. 041079 (approved May 12, 2005); amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added and subsequent subsections renumbered, Bill No. 100749 (approved January 26, 2011), effective April 26, 2011; amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015; amended, Bill No. 160365-A (approved October 19, 2016).] [History: Added and former subsection renumbered as 12, Bill No. 160365-A (approved October 19, 2016).] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added, Bill No. 041079 (approved May 12, 2005); amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 160462 (approved June 28, 2016).] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added, Bill No. 230647 (approved December 13, 2023).] [History: Added, Bill No. 230647 (approved December 13, 2023).] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Added, Bill No. 090568-AAA (approved February 17, 2010); amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015; amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012.] [History: Added, Bill No. 140608 (approved November 12, 2014), effective January 1, 2015; amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended by renumbering, Bill No. 041079 (approved May 12, 2005).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 180175 (approved June 6, 2018).] SECTION A-602 FACILITY LICENSE A-602.1 Suspension: Any owner or operator of a facility licensed under this code or the technical codes who has been ordered to pay a fine pursuant to this Section and who has not paid such fine within 10 days of imposition of a final order from which all appeals have been exhausted shall have said license suspended and shall cease operations until all fines and costs are paid. A-602.2 Cease operation: To enforce the provision of Section A-602.1, the department shall, without further notice, issue a Cease Operations Order setting forth the unpaid fines and costs and cause the premises to be vacated of all employees, patrons and occupants until all such fines and costs are paid. Such Cease Operations Order shall otherwise meet the requirements of and be subject to the procedures set forth in Section A-505.0. SECTION A-603 INDIVIDUAL LICENSE A-603.1 Suspension: Any person licensed to conduct a trade or practice under this code or the technical codes who has been ordered to pay a fine pursuant to this Section and who has not paid such fine within 10 days of imposition of a final order from which all appeals have been exhausted shall have said license suspended and shall stop any work in progress under said license until all fines and costs are paid. A-603.2 Stop Work Order: To enforce the provision of Section A-603.1, the department shall, without further notice, issue a Stop Work Order at each location where work is in progress under said license. The Stop Work Order shall set forth the unpaid fines and costs and shall otherwise meet the requirements and be subject to the procedures set forth in Section A-504.0. A-603.3 Willful violation: The department is authorized to suspend or revoke a trade or practice license for willful violation of this code or the technical codes. A-603.4 Unpaid fees: When a license holder has been issued a permit and has failed to properly remit the required fees for that permit, the Department is authorized to refuse issuance of additional permits to that licensed person or business until the outstanding fees have been paid in full. [History: Added, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] SECTION A-604 COMPLIANCE REQUIRED A-604.1 Penalty not withstanding: The imposition of any penalty imposed by this Chapter shall not relieve the violator from compliance with the notice of violation; nor shall it prevent the department from instituting any appropriate action to prevent unlawful construction or to restrain, correct or abate a violation, or to prevent illegal occupancy or use of a building, structure or premises or to stop an illegal act, conduct, business or occupancy of a building or structure or operation of mechanical equipment or systems on or about any premises. CHAPTER 7 CERTIFICATES AND APPROVALS SECTION A-701 CERTIFICATE OF OCCUPANCY A-701.1 General: A certificate of occupancy, indicating compliance with permits and construction documents, shall be obtained prior to occupancy of a building or portion thereof in the following cases: 1. Erection of a new building, 2. Erection of an addition to a building, 3. Change from one Occupancy Classification to another, 4. Relocation of a building, 5. Interior alteration of an existing building or space, 6. A change of occupancy as defined in A-106.1. Exceptions: A certificate of occupancy shall not be required under the following conditions: 1. The work is limited to additions or alterations to existing one- or two-family occupancies. 2. The work is limited to minor alterations of any existing occupancy that do not impact the egress or fire protection of the building or space. 3. Where a Family Child Day Care facility is operated in a one- or two-family dwelling, provided it is licensed pursuant to the Fire Code. A-701.2 Review and approval: In each case where a Certificate of Occupancy is required by Section A-701.1, construction documents shall be submitted as prescribed in Section A-301.6 for review by the department for conformance to the Building Code in effect at the time of application. Upon approval, the code official shall prepare the certificate in accordance with this Section and procedures of the department. A maximum of one building as defined by the Building Code shall be included on any one certificate. A-701.2.1 Approval prior to occupancy. Newly constructed buildings, altered areas of existing buildings and relocated buildings shall not be used or occupied, and a change of occupancy of a building or portion thereof shall not be made, until the code official has issued a certificate of occupancy. A-701.2.2 Certificates of Occupancy for uncertified buildings. Pursuant to the UCC, the Department shall issue a Certificate of Occupancy to an existing building that was not previously issued a Certificate of Occupancy if the building meets the requirements of the Existing Building Code. The code official may deny the issuance of a Certificate of Occupancy if the official deems that a building is unsafe because of inadequate means of egress, inadequate lighting and ventilation, fire hazards or other dangers to human life or to public welfare. A-701.3 Issuance: Upon successful completion of the final inspection in accordance with Section A-402.5 and within five business days thereafter, the certificate of occupancy shall be issued by the code official. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the technical codes or other provisions of The Philadelphia Code. The certificate shall be available for inspection by the code official at any reasonable time. A-701.3.1 Health care facilities. The code official shall not issue a Certificate of Occupancy for a health care facility until the Pennsylvania Department of Health has approved the occupancy under 28 Pa. Code § 51.5. A-701.3.2 Conditions related to prerequisite approvals. Where the issuance of the building permit includes a prerequisite approval as listed in Section A-305.2.1.6, and such approval was granted with conditions, the Department is authorized to withhold the issuance of the Certificate of Occupancy until such conditions of approval have been satisfied. The department issuing the conditional approval must notify the Department and the permit holder prior to the final inspection of the permit where conditions of approval have not been satisfied. A-701.3.3 Flood protection confirmation. Prior to the issuance of a Certificate of Occupancy, the permit holder shall submit a Flood Elevation Certificate (or Floodproofing Certificate if a non-residential structure) as published by FEMA. The Certificate shall be completed by a registered design professional. A-701.4 Contents of certificate: The certificate of occupancy shall include a statement that the described portion of the structure has been inspected for compliance with the applicable code requirements for the occupancy and division of occupancy and the use for which the proposed occupancy is classified and shall specify the following: 1. The address of the building. 2. The location within the building if for part of a building. 3. The edition of the code under which the permit was issued. 4. The Occupancy Classification Group(s) in accordance with the Building Code. 5. The type of construction as defined by the Building Code. 6. If and where an automatic sprinkler system is provided and whether it is required. 7. Any variances or special conditions. 8. The permit number. 9. The date of the final inspection. 10. The name and address of the permit holder. 11. The printed name of the building code official. A-701.5 Partial or temporary occupancy: Upon request of the applicant, a temporary or partial certificate of occupancy may be issued to occupy the premises or a portion of the premises before completion of the entire work or operation covered by the permit provided that such portion or portions will be occupied safely prior to full completion of the structure or installation of equipment and systems without endangering life or public welfare. Such issuance shall be in accordance with departmental procedures and the code official shall notify the applicant of any limitations or restrictions imposed by the partial or temporary occupancy. A-701.6 Posting: Either the original or a true copy of the Certificate of Occupancy shall be posted in each building, available to inspection. Exceptions: 1. Residential buildings and buildings of Group R-3 occupancy; 2. Buildings of Group R-2 occupancy which have no management office on premises. A-701.7 Revocation: The code official is authorized to, in writing, suspend or revoke a certificate of occupancy issued under the provisions of this code and the technical codes wherever the certificate is issued in error or on the basis of incorrect information supplied. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-702 CERTIFICATE OF APPROVAL A-702.1 General: A certificate of approval shall be issued by the code official upon completion of the final inspection in accordance with Section A-402.5 for permits issued pursuant to the Philadelphia Building, Construction and Occupancy Code for which a certificate of occupancy is not issued. A-702.2 Contents of certificate: The certificate of approval shall specify the following: 1. The address of the building. 2. The location within the building if for part of a building. 3. The permit number. A-702.3 Inspection: The certificate shall be available for inspection by the code official at any reasonable time. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-703 SPECIAL CERTIFICATE OF INSPECTION A-703.1 Special occupancy requirement for structures in Group E occupancy: No structure in Group E occupancy, the Educational occupancy, as defined in Subcode "B" of Title 4 owned or operated by an entity to which the City provides substantial funding, shall be occupied unless a current special certificate of inspection has been issued in connection with such structure. Exception: Day care facilities that are not part of a school are not regulated under this subsection, except that day care facilities that are not part of a school, but at which thirteen or more children are cared for must comply with the certification requirements pertaining to water quality set forth in subsection 4.B. of Section A-703.2. A-703.2 Issuance of special certificates of inspection: Special certificates of inspection shall be issued on the following basis: 1. A special certificate of inspection shall be valid for no more than a single one year period, between August 1 of a given year and July 31 of the following year; 2. For use at the start of such one year period on August 1, such special certificate must be obtained during the nine month period between November 1 and August 1 immediately preceding the beginning of the one year period; 3. A certificate obtained after the one year period has started on August 1 is valid only for the remainder of that one year period; 4. The Department shall not issue a special certificate of inspection unless the building has been inspected for fire, safety, electrical, lead paint, water quality, asbestos, and all other property-related hazards and: A. the Commissioner of Licenses and Inspections has certified that the building is in substantial compliance with the fire, safety and all other property-related requirements of this Code and that the building can be occupied safely without endangering life or public safety or welfare; B. the Health Department or a testing agency certified by the Pennsylvania Department of Environmental Protection has certified, within the previous five years, that the building is in substantial compliance with applicable water quality requirements of the Board of Health, provided that in no event shall applicable water quality requirements be deemed to permit lead in water at an outlet such as a sink or water fountain that is in service at 10 ppb or more. Any water outlet determined to exceed any such water quality requirements shall be taken out of service within 24 hours of notification of the relevant test. The owner of the educational occupancy shall post the results of the most recent water quality testing at each particular educational occupancy to a generally available website within ten days of receipt of the results. Effective June 1, 2025, any drinking fountain at an Educational Group E occupancy that satisfies the requirements of Section PM-502.6 shall be deemed compliant with water quality requirements of this subsection. C. the owner of the building or its agent has provided either a certification from an Electrical Inspection Agency licensed by the City or, if the owner of the structure employs, on a full-time basis, an electrician licensed by the City, a certification from such electrician that is also signed by a person with supervisory authority over the electrician, such as a facilities manager, operations manager, or chief operating officer, that the building is in substantial compliance with the provisions of the Philadelphia Electrical Code. D. the owner of the building or its agent has provided certification that the building either (i) was built subsequent to 1978; or (ii) is not regularly occupied by students; or (iii) all areas of the building that are frequented by students have been inspected and determined to be safe from lead based paint hazards. (.1) An area of a building shall be determined to be safe from lead based paint hazards only if it is free of any lead contaminated debris, such as dust, chips or other paint particulate, on surfaces; and it is free of any condition that may cause exposure to lead from lead-contaminated paint dust or debris, including, but not limited to: flaking, peeling, spalling or efflorescing paint. Flaking or peeling means that paint is visibly flaking from the surface or a person is able to get a fingernail under a paint layer. Spalling means moisture intrusion causing plaster to delaminate from substrate. Efflorescing means that crystalline deposits or white powdery residue is on plaster surfaces. (.2) A building area shall be certified as safe from lead based paint hazards based on the visual observation of a certified lead inspector. A "certified lead inspector" shall be as defined in Section 6-802. (a) All inspections relating to lead paint, including any assessments or evaluations, performed pursuant to subsection (.1) or otherwise, shall be performed in accordance with the following: (i) No fewer than ten (10) days prior to the inspection, the person responsible for management of the building shall ensure that notice of the pending inspection and the scope of work involved is given to staff and parents of children in the school, or their representatives. (ii) No more than ten (10) days after the completion of any inspection, the person responsible for management of the building shall ensure that the results of the inspection, including the location, amount and condition of any lead paint that was found, is posted on the website of the entity responsible for operation of the building. (.3) To the extent any condition is found during the course of any inspection pursuant to subsection (.2) or otherwise that would prevent any portion of the building frequented by students from being certified as safe from lead based paint hazards, the entity responsible for operation of the building shall take all appropriate steps to achieve such certification within ninety (90) days of the adverse finding. Until any appropriate remediation or stabilization activity takes place, the area shall be kept clean by the use of a HEPA (high efficiency particulate air) filtration vacuum cleaner or wet wiping; monitoring of paint conditions; and ongoing cleaning of surfaces; and if there is a potential for occupant contact with any damaged conditions, the area shall be isolated by means of a plastic barrier adhered to the wall surface, or other appropriate isolation tool. During remediation or stabilization, the person responsible for management of the building shall not allow any students to occupy the affected portion of the building. (a) The person responsible for management of the building shall ensure that advance notice of any remediation, abatement or clean-up work be given to staff and parents of children in the school, or their representatives, and posted on the entity's website, as promptly as practicable; and that the results of the work be posted on the website within ten (10) days after completion. E. the Health Department or a testing agency certified by the Pennsylvania Department of Labor and Industry has certified, within the previous three (3) years and four (4) months, that the building is in substantial compliance with the best practices for testing, remediation, abatement, cleaning, and management of asbestos, and other property-related hazards not otherwise regulated in this Section as identified by the Managing Director no less than six (6) months prior to the issuance of the special certificate of inspection. (.1) The owner of the educational occupancy shall post the results of the testing required by this Section at each particular educational occupancy to a generally available website within ten (10) days of receipt of the results. F. The Managing Director shall identify any additional property-related hazards as well as best practices regarding the identification and remediation of all property-related hazards after considering the recommendations of the Facility Safety and Improvement Advisory Group, which shall consist of the following appointments by the Mayor: (.1) One (1) representative of the School District of Philadelphia; (.2) One (1) representative of the Philadelphia Federation of Teachers; (.3) One (1) representative of the Service Employees International Union Local 32BJ; (.4) One (1) representative of the Commonwealth Association of School Administrators Local 502; (.5) One (1) parent-representative of Philadelphia Home & Schools Council; (.6) One (1) parent-representative of Philadelphia School Advisory Councils; (.7) One (1) parent who advocates on environmental justice, health, construction, or related matters; (.8) One (1) expert on environmental testing and abatement who is unaffiliated with the School District of Philadelphia; (.9) One (1) representative of Laborers District Council of the Metropolitan Area of Philadelphia and Vicinity; (.10) One (1) representative of International Association of Heat and Frost Insulators and Allied Workers Local 14; (.11) One (1) representative of the Philadelphia Building & Construction Trades Council; (.12) One (1) representative of the Council of the City of Philadelphia; and (.13) No fewer than one (1) and not more than three (3) students of Philadelphia schools, who may serve in a non-voting capacity. 5. The contents of special certificates of inspection issued under this subsection shall be made available for inspection by the Department and shall contain the following information: A. The name of the owner of the building; B. The address of the building; C. The location of automatic fire sprinkler system(s), if any; D. Location and type of fire alarm system(s), if any; E. Location of fire standpipe system(s), if any; F. If provided for only a portion of the building, a description of the portion of the building covered by the certificate of inspection; G. The time period for which it has been issued. 6. Upon the request of the owner of the structure, a partial special certificate of inspection shall be issued to occupy a portion of the premises upon certification by the Commissioner of Licenses and Inspections that such portion of the premises has been certified to be in substantial compliance with fire, safety, electrical, lead paint, water quality and other property-related requirements provided that such portion or portions can be occupied safely prior to correction of the defect preventing full certification without endangering life or public safety or welfare. Such issuance shall be in accordance with procedures established by the Department and the code official shall notify the applicant of any limitations or restrictions imposed by the partial occupancy; and 7. No fee shall be charged by the City for the issuance of special certificates of inspection or the inspections performed by the City in connection therewith. A-703.3 Reporting Requirement. On August 15 of each year, the Commissioner of Licenses and Inspections shall provide the following information in a report to the Mayor, the President of City Council, and the owner or person responsible for each structure, including the Superintendent of Schools, and shall provide a copy to the Chief Clerk of City Council, containing the following information: 1. The names and addresses of the structures in Group E occupancy for which a special certificate of inspection under Section A-703.1 is required to permit occupancy; 2. The list of structures for which certification is required shall be divided into three subgroups: structures for which certification pursuant to Section A-703 has been issued; structures for which partial certification has been issued; and structures for which certification has not been issued; 3. In connection with the listing of structures for which certification has been issued, the listing shall include, for each of the structures, a description of the conditions, if any, that bring the structure out of total compliance with the fire, safety, electrical, lead paint and all other property-related requirements of this Code and any applicable water quality requirements of the Health Department, but which do not prevent certification that the building can be occupied safely without endangering life or public safety or welfare. 4. In connection with the listing of structures for which partial certification has been issued or for which certification has not been issued, the listing shall include a description of the fire, safety, electrical, lead paint, water quality and other property-related requirements that prevented full certification and a description of the actions that must be taken by the owner of the structure to obtain full certification. Such description shall also include a description of the conditions, if any, that bring the structure out of total compliance with the fire, safety, electrical, lead paint and all other property-related requirements of this Code and any applicable water quality requirements of the Health Department, but which do not themselves prevent certification that the building can be occupied safely without endangering life or public safety or welfare. 5. The Health Department and any Electrical Inspection Agency or electrician involved in inspection of the structure shall provide to the Department of Licenses & Inspections any information in its possession relevant to such reports within ten days of the inspection. [History: Added, Bill No. 020313-A (approved January 27, 2003). Section 2 of Bill No. 020313-A provides: "Effective date. No special certificate of inspection shall be required under the provisions of this Ordinance until August 1, 2003. By February 1, 2003, the Department of Licenses and Inspections shall provide to the recipients listed in Subsection A-703.3 any information available to it, based on inspections performed in the preceding nine months, that in future years must be provided by the Department pursuant to Section A-703.3." Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 160618 (approved January 24, 2017). Section 2 of Bill No. 160618 provides: "This Ordinance shall be effective with respect to special certificates of inspection required on and after August 1, 2017."] [History: Amended, Bill No. 210685-AA (approved June 1, 2022). Section 2 of Bill No. 210685-AA provides: "This Ordinance shall be effective with respect to special certificates of inspection required for occupancy for one-third of School District of Philadelphia-funded schools on and after August 1, 2023; one-third of such schools on and after August 1, 2024; and the remaining third of such schools on and after August 1, 2025. The specific schools with respect to which such certificates are required by such deadlines shall be determined by the Managing Director, in consultation with the School District, and a listing of all such schools, and the deadline for the applicable certificate for each school, shall be filed with the Chief Clerk of Council by August 1, 2022."] [History: Amended, Bill No. 160618 (approved January 24, 2017). See note 208 for effective date provisions. Amended, Bill No. 180700 (approved January 22, 2019); amended, Bill No. 220415 (approved September 13, 2022).] [History: Added, Bill No. 180700 (approved January 22, 2019).] [History: Added, Bill No. 210685-AA (approved June 1, 2022). See note 209 for effective date provisions.] [History: Added, Bill No. 210685-AA (approved June 1, 2022). See note 209 for effective date provisions.] [History: Amended, Bill No. 030780 (approved December 31, 2003).] CHAPTER 8 APPEALS AND VARIANCES SECTION A-801 TECHNICAL APPEALS A-801.1 Right of appeal: Any person who is directly aggrieved by the issuance, transfer, renewal, refusal, suspension, revocation or cancellation of any license issued pursuant to this code and the technical codes (except licenses issued pursuant to the Property Maintenance Code); by a refusal of permit pursuant to this code and the technical codes; or by any notice, order or other action by the code official as a result of any inspection pursuant to this code and the technical codes, shall have the right to appeal to the appropriate technical board as set forth in Section A-802.1. A-801.2 Application for appeal: Appeals shall be filed in writing on forms provided by the department in accordance with procedures established by the department and/or the appeal boards. The appeal shall be accompanied by the required fee and a copy of the violation or permit refusal notice when applicable. The appeal shall be filed within 30 days of the date of the action being appealed. Exception: Appeals from unsafe or imminently dangerous designations by the department shall be filed within 5 days of the date of such notice. A-801.3 Basis for appeal: An application for appeal shall be based on a claim that: 1. The true intent of the applicable code or regulations adopted thereunder has been incorrectly interpreted; 2. The provisions of the code do not fully apply; or 3. An equivalent form of construction or installation is proposed. A-801.4 Public hearing: All appeals considered by the technical boards shall be heard in public at such times and locations scheduled by the boards. The appellant, the owner or the owner's agent, and the code official shall be notified of the date, time and place of the hearing. The board shall recommend to: 1. Deny the request in whole or in part; 2. Grant the request in whole or in part; or 3. Grant the request upon certain conditions being satisfied. A-801.5 Notice of decision: The board shall provide a written notice of its decision to the appellant, the owner or owner's agent, and the code official. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Added, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012.] SECTION A-802 TECHNICAL BOARDS A-802.1 General: Appeals filed pursuant to Section A-801 shall be submitted to the technical board specified in Table A-802.1. The code official shall transmit to such board all the documents, or photocopies thereof, which constitute the record upon which the action appealed from was taken and the reasons for said action. TABLE A-802.1 TECHNICAL APPEAL BOARDS Subject Code | Technical Appeal Board Electrical Code Energy Conservation Code Existing Building Code Fuel Gas Code Mechanical Code Performance Code for Buildings and Facilities Plumbing Code Property Maintenance Code Residential Code | Board of Building Standards Building and Residential Codes – Accessibility for the physically disabled | Pennsylvania Accessibility Advisory Board Fire Code | Board of Safety and Fire Prevention Zoning Code | Zoning Board of Adjustment A-802.2 Variances: Variances from the technical codes shall be granted subject to the provisions of Sections A-802.2.2.1 through A-802.2.2.4, shall be in writing and shall be available for public inspection in the department. A-802.2.1 Board of Building Standards: The commissioner of the Department is authorized to grant an extension of time or a variance from the requirements of the Building, Electrical, Energy Conservation, Existing Building, Fuel Gas, Mechanical, Performance, Plumbing, Property Maintenance and Residential Codes upon the written recommendation of a majority of the Board of Building Standards, as established by provisions of the Philadelphia Home Rule Charter. A-802.2.1.1 Board recommendation: Recommendation for an extension of time or a variance from a technical code by the Board of Building Standards shall be made upon written petition by, or on behalf of, the owner where there is a finding that: 1. The variance will fulfill the intent of the code; and 2. Literal enforcement will result in unique and unnecessary hardship or extraordinary conditions make literal compliance impractical; and 3. The variance will not be an unreasonable deviation from the requirements of the code; and 4. In the case of a variance in an area prone to flooding, the considerations and conditions for issuance set forth in Appendix G of the Philadelphia Building Code are satisfied; and 5. In the case of buildings designated as historic pursuant to Chapter 14-1000 of The Philadelphia Code or listed in the National Register of Historic Places, where strict compliance with a provision of this Title would interfere with the historic character of the property, the variance does not constitute a material life safety hazard; 6. In the case of the request for an extension of time, efforts are being made to come into compliance as quickly as possible; and 7. A reasonable accommodation is requested under the Fair Housing Act for provisions related to the technical codes. A-802.2.1.2 Flood plain: In such case where the Board of Building Standards shall recommend a variance to construct a structure below the Regulatory Flood Elevation, the owner shall be notified in writing that the variance will result in increased premium rates for flood insurance and an increased risk to property and life. The Board of Building Standards shall maintain a record of all variance actions within the flood plain and justification therefor, and shall report such variances issued in an annual report to the Administrator of the Federal Insurance Administration. A-802.2.1.3 Determination of substantial improvement in areas prone to flooding: When the code official provides a finding of substantial improvement to a permit applicant regarding a building or structure regulated by the technical codes as required in Section A-302.1.2, and the applicant disagrees with such finding, the applicant may file an appeal with the Board of Building Standards. The Board shall determine whether the value of the proposed work constitutes a substantial improvement. A-802.2.1.4 Advisory input: The Board of Building Standards shall consider advice from the Electrical Advisory Board and Plumbing Advisory Board when hearing appeals from the Electrical Code and Plumbing Code respectively where such advice is submitted. A-802.2.1.4.1 Delegation. The Board of Building Standards may delegate its authority to the Plumbing Advisory Board to hear appeals from requirements of the Plumbing Code, and provide recommendations as authorized by Section A-203.3 on alternative material, design or method of construction related to plumbing. Decisions of the Plumbing Advisory Board recommending granting of such appeals shall be submitted directly to the Commissioner for further consideration. Decisions of the Board recommending denial of such appeals shall be reviewed by the Board of Building Standards in accordance with A-802.2.1. A-802.2.2 Accessibility Advisory Board: Pursuant to the UCC, the Secretary of the Pennsylvania Department of Labor and Industry (Secretary) has the exclusive power to grant modifications and extensions of time and decide issues of technical infeasibility under Chapter 11 (Accessibility) of the Philadelphia Building Code and other accessibility requirements contained in or referenced by the technical codes for individual projects. A-802.2.2.1 Variance requests. Pursuant to the UCC, the Secretary will review all applications for modifications or variances of Chapter 11 (Accessibility) of the Philadelphia Building Code and any other accessibility requirements contained in or referenced by the Philadelphia Building Construction and Occupancy Code. The Pennsylvania Accessibility Advisory Board will advise the Secretary whether modification or variance should be granted or whether compliance is technically infeasible. A-802.2.2.2 Code official's decisions. Pursuant to the UCC, the Secretary will hear appeals from decisions of code officials; recommend modifications or variances, or extensions of time. An appeal of a decision of a code official may be based only on a claim that the true intent of the UCC or the Building Construction and Occupancy Code was incorrectly interpreted, the UCC does not apply, or an equivalent form of construction is to be used. A-802.2.2.3 Filing of appeal. An owner or owner's agent shall file an appeal regarding accessibility provisions with the Pennsylvania Accessibility Advisory Board on a form provided by the Pennsylvania Department of Labor and Industry. A-802.2.2.4 Stay of enforcement. An appeal to the Pennsylvania Accessibility Advisory Board will automatically suspend an action to enforce an order to correct except where there is an unsafe building, structure or equipment. A-802.2.3 Board of Safety and Fire Prevention: The Fire Commissioner is authorized to grant an extension of time or a variance from the requirements of the Fire Code upon the written recommendation of a majority of the Board of Safety and Fire Prevention. A-802.2.3.1 Board recommendation: Recommendation for an extension of time or a variance from the Fire Code by the Board of Safety and Fire Prevention shall be made upon written petition by, or on behalf of, the owner where there is a finding that: 1. The variance will fulfill the intent of the code; and 2. Literal enforcement will result in unique and unnecessary hardship or extraordinary conditions make literal compliance impractical; and 3. The variance will not be an unreasonable deviation from the requirements of the code; and 4. In the case of buildings designated as historic pursuant to Chapter 14-1000 of The Philadelphia Code or listed in the National Register of Historic Places, where strict compliance with a provision of this Title would interfere with the historic character of the property, the variance does not constitute a material life safety hazard; and 5. In the case of a request for an extension of time, efforts are being made to come into compliance as quickly as possible. A-802.2.4 Zoning Board of Adjustment: The Zoning Board of Adjustment is authorized to hear and decide appeals in zoning matters in accordance with provisions of Section 4-607 of the Philadelphia Home Rule Charter, the Zoning Code and regulations pursuant thereto. A-802.3 Code compliance: Compliance with a variance issued by the Fire Commissioner, Commissioner of Licenses and Inspections or the Zoning Board of Adjustment shall be considered in compliance with the code from which the variance is granted. A-802.4 Further appeal: Any person who has had a variance appeal hearing and has been denied a variance shall have the right to appeal that decision to the Court of Common Pleas within 30 days of the date of the notice of decision. [History: Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 120774-A (approved January 14, 2013).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 120774-A (approved January 14, 2013); amended, Bill No. 180175 (approved June 6, 2018).] [History: Added, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 120774-A (approved January 14, 2013).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] SECTION A-803 NON-TECHNICAL APPEALS A-803.1 Right of appeal: Any person who has been denied a hearing before a technical board; or who is aggrieved by the issuance, transfer, renewal, refusal, suspension, revocation or cancellation of any City license which is not listed for appeal to a technical board in Section A-801.1; or who is aggrieved by a notice, order or other action of the department relative to this code or the technical codes which is not listed for appeal to a technical board in Section A-801.1, shall have the right to appeal to the Board of License and Inspection Review. Exception: All zoning matters are appealed to the Zoning Board of Adjustment. A-803.2 Application for appeal: Appeals shall be filed in writing on forms provided by the code official in accordance with procedures established by the code official and/or the board. The appeal shall be accompanied by a copy of the notice, order or other document which is the subject of appeal as applicable. The appeal shall be filed within 30 days of the date of the action being appealed. A-803.3 Public hearing: All appeals considered by the board shall be heard in public at such times and locations scheduled by the board. SECTION A-804 BOARD OF LICENSE AND INSPECTION REVIEW A-804.1 Decisions: The Board of License and Inspection Review shall, by a majority vote, affirm, modify, reverse, vacate or revoke the notice, order or action from which an appeal is taken; however, the board shall not have the authority to grant variances from the technical provisions of the technical codes. A-804.2 Record: Each decision of the board shall be in writing and shall be available for public inspection in the department. SECTION A-805 ACTION PENDING APPEAL A-805.1 Stay of action: Whenever an appeal filed pursuant to Sections A-801.0 or A-803.0 is pending, compliance with the decision, notice of violation, order, or license suspension or revocation which is the subject of appeal shall not be required except as provided in Section A-805.2. A-805.2 Compliance action: An appeal shall not constitute a stay of proceedings by the department or the Fire Department where either department finds and certifies in writing that the violation is intentional or that there exists a condition of immediate danger or hazard to health, safety or welfare which requires immediate compliance. An appeal shall not constitute grounds for lifting a Stop Work Order or Cease Operations Order. CHAPTER 9 FEES [History: This Chapter includes certain material inadvertently omitted in the enrolled bill (Bill No. 960591-A). The omissions were subsequently corrected by Bill No. 980795 (approved January 5, 1999). Former Section A-907.0, added by Bill No. 980760 (approved December 30, 1998), was deleted by Bill No. 000348 (approved August 11, 2000). Accelerated plan review is now addressed in Section A-901.10.] SECTION A-901 GENERAL A-901.1 Reference: All permits, licenses, certificates and services established by the technical codes for which the City has established a fee, shall be subject to such fee as set forth in this Chapter. A-901.2 Pre-requisite: An application shall not be accepted, a permit, license or certificate shall not be issued, nor a listed service performed until the designated fees have been paid. Where it is found that final payment of such fees has not been made, the permit, license or certificate may be revoked. A-901.3 Multiple fees: The payment of the fee for a particular permit, license or service shall not relieve the permit holder, license holder or applicant from the payment of fees that are prescribed for other permits, licenses and services associated with the activity, project or premises. A-901.4 Frequency: License fees are annual with the license year as determined by the department and permit fees are per occasion unless indicated otherwise. Service and miscellaneous fees are as stated. A-901.5 Refund of permit fees: Where the work authorized by a permit is not commenced, a request for refund of the permit fee shall be accepted on forms provided by the department within one year from the date of permit issuance. An approved refund shall not exceed fifth percent (50%) of the permit fee minus a two hundred dollar ($200) processing fee. A-901.6 Fee Basis: Permit and occupancy fees shall be calculated separately for each property. A-901.7 Filing fees: The department is authorized to require non-refundable application fees to be charged upon application for permits and licenses. The amount of such fees shall be as set forth in this Chapter or as otherwise established by regulations of the department. Payment of such fees shall be applied as a credit upon charge for the applicable permit or license fee. A-901.8 Rough-in permits: The Department is authorized to issue permits for the rough-in of various utility systems, service systems and other building systems or elements as authorized by the Department from time to time, where such work is applied for in advance of the application for the complete system or element installation. Each type of system or element shall be applied for separately and shall require a permit fee of one hundred fifty dollars ($150). A-901.9 Annual permits: Where annual permits are issued pursuant to Section A-302.7, the fee shall be one thousand three hundred fifty dollars ($1,350) per year, payable on a schedule established by the Department. A-901.10 Accelerated plan review: The department is authorized to provide accelerated review of plans associated with the issuance of any permit required under Title 4 or 14 of this Code, provided that all zoning permit applications for affordable housing projects shall receive accelerated plan review at no additional cost. The fees and charges for accelerated plan review shall be in addition to any permit fee otherwise set forth in this Chapter, and shall be published in appropriate schedules. A-901.10.1 Additional accelerated plan review fee: The additional cost-based fee for accelerated review shall be three hundred fifty dollars ($350) per application, or such other amount as may be established by the department by regulation. Such amount shall neither exceed the costs to administer and provide accelerated review services nor exceed three hundred fifty dollars ($350) multiplied by the fraction of the most recently published Consumer Price Index for all Urban Consumers (CPI-U) All Items Index, Philadelphia, Pennsylvania, as of the effective date of the proposed fee increase, divided by the most recently published CPI-U as of July 1, 2020. A-901.10.1.1 The accelerated review fee shall be paid at the time the application is submitted and is non-refundable. A-901.10.1.2 There shall be no additional cost-based fee for accelerated review of a plumbing, electrical, mechanical or fire suppression system permit application that is requested at the same time as accelerated review of a building permit application for the same project. A-901.10.2 Accelerated plan review surcharges: A-901.10.2.1 A surcharge of one thousand six hundred fifty dollars ($1,650) shall be added for accelerated review in connection with a building permit application. A-901.10.2.2 A surcharge of seven hundred dollars ($700) per permit application shall be added for accelerated review in connection with all other applicable permit applications, including for each zoning, electrical, plumbing, mechanical, fire suppression system, total demolition and signage permit application. A-901.10.2.3 There shall be no surcharge for accelerated review of a plumbing, electrical, mechanical or fire suppression permit application that is requested at the same time as accelerated review of a building permit application for the same project. A-901.10.2.4 Such surcharges shall be payable prior to receipt of the permit(s) and are in addition to any cost-based fee charged pursuant to subsection A-901.10.1 or another provision of the Code. A-901.10.2.5 Disputes concerning payment or the amount of any surcharge pursuant to this subsection A-901.10.2 shall be governed by Chapter 19-1700 ("Review, Refunds and Compromises"). A-901.11 Administrative fees: Fees for items that require the Department to provide non-routine or personalized administrative services, shall be as follows. The Department is authorized to revise such fees or establish fees by regulation for any other similar services to cover the costs of program administration. The fee for services that are provided shall be in addition to any permit or license fee set forth in this Chapter or as required by an Act of the Commonwealth. For amending or transferring permits . . . . . $50 For copies of licenses, permits and certificates . . . . . $15 For replacement of a photo ID license, certificate or permit . . . . . $25 For processing a permit extension request before permit expiration . . . . . $50 Exception: Owner occupied one-family dwellings . . . . . No fee For processing a permit reinstatement request . . . . . $300 Exception: Owner occupied one-family dwellings . . . . . No fee For the electronic storage of building plans for future retrieval . . . . . $4 per page For the issuance of each approved permit for which a surcharge is required pursuant to Act 157 of 2006 . . . . . $3 per permit A-901.12 Inspection fee: The Department is authorized to charge inspection fees in accordance with Sections A-901.12.1 through A-901.12.3. A-901.12.1 Permit reinspection fee: The Department is authorized to charge a reinspection fee of one hundred dollars ($100) for each additional inspection that is required as a result of the need to re-schedule a scheduled permit inspection for one or more of the following reasons, and the Department shall have the discretion to require that such fee be paid in advance of any re-inspection: 1. The work is not constructed in accordance with the applicable code; 2. The work is not ready for inspection; 3. Access to the work to be inspected is not provided; or 4. A violation of the code is observed during a permit inspection. A-901.12.2 Code violation reinspection fee: When, upon reinspection, the Department determines that a condition previously found not in compliance with a provision of the technical codes or regulations promulgated thereunder continues not to be in compliance, the Department is authorized to charge a further reinspection fee for all second and subsequent reinspections, as follows: Second reinspection . . . . . $100 Third reinspection . . . . . $200 Fourth and subsequent reinspections . . . . . $350 A-901.12.2.1 License or permit suspension: In addition to other penalties provided for in this code, any person who fails to remit the required reinspection fee to the Department when requested, shall have his or her license or permit to conduct the business activity or operation suspended, and the business activity or operation shall cease until the payment of fees owed has been received by the Department. A-901.12.3 After hours inspection fee: A fee of sixty dollars ($60) per hour, with a minimum charge of four hours, shall be charged to any person requesting an inspection be performed at any time other than ordinary working hours for inspections. A-901.13 Work without or in excess of a permit or license: In addition to the permit or license fee, an inspection fee equal to the permit or license fee shall be imposed when work has commenced without first obtaining the required permit(s) or license(s). A-901.14 Contract submission: The department is authorized to require the applicant to submit a copy of the original executed contract(s) to validate the declared scope and/or value of construction. Such copy shall be submitted prior to the issuance of the permit or prior to issuance of the Certificate of Occupancy or Certificate of Approval, at the department's option. A-901.15 License and permit fee revisions: The Department, by regulations effective on or after July 1, 2018, is authorized to revise the fees established in Sections A-902 through A-907 of this Chapter, excluding Section A-907.1.2 regarding Zoning Board of Adjustment fees, or adopt fees not otherwise provided for in such Sections, based upon the costs to administer and enforce the applicable programs and services; provided that no fee shall be increased to an amount higher than the fee as it existed on July 1, 2017, multiplied by the CPI Multiplier, as defined in Section 9-102 of the Code; and further provided that for fees established in this Code after July 1, 2017, the fee shall not be increased to an amount higher than the fee on the date that it was established, multiplied by the CPI Multiplier, using as the base figure for purposes of determining the CPI Multiplier the most recently published CPI-U as of July 1 of the year the fee was established. A-901.15.1 A schedule of all current fees shall be maintained on the Department's website. [History: Amended, Bill No. 000348 (approved August 11, 2000), effective July 1, 2000. Amended, Bill No. 030780 (approved December 31, 2003).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 050267 (approved June 15, 2005); amended, Bill No. 120897 (approved January 14, 2013); amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017; amended, Bill No. 190767 (approved November 12, 2019), effective July 1, 2020; amended, Bill No. 250043 (became law September 11, 2025).] [History: Amended, Bill No. 250043 (became law September 11, 2025).] [History: Amended, Bill No. 050267 (approved June 15, 2005); amended, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 080853 (approved December 8, 2008); amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 260393 (approved June 12, 2026), effective July 1, 2026.] [History: Added, Bill No. 080853 (approved December 8, 2008).] [History: Amended, Bill No. 040422 (approved June 3, 2004); amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 040422 (approved June 3, 2004); amended, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Amended, Bill No. 040422 (approved June 3, 2004).] [History: Amended, Bill No. 040422 (approved June 3, 2004).] [History: Renumbered Bill No. 040422 (approved June 3, 2004).] [History: Amended, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Added, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017; amended, Bill No. 180175 (approved June 6, 2018); amended, Bill No. 240430 (approved January 15, 2025); amended, Bill No. 260203 (approved June 11, 2026), effective July 1, 2026.] SECTION A-902 BUILDING, FUEL GAS AND MECHANICAL CODE FEES A-902.1 General: Fees for permits, appeals, certificates and administrative services related to activity regulated by the Building, Fuel Gas and Mechanical Codes shall be as set forth in this Section. A-902.2 Construction: Permit fees for new construction, additions, alterations, demolition, occupancy and repairs shall be as set forth in Sections A-902.2.1, except as otherwise specified in Sections A-902.2.2 through A-902.2.8. A-902.2.1 Constructed area: The permit fee for new construction, additions, alterations and repairs shall be based on the constructed area as follows: For new construction and additions: 500 square feet or less . . . . . $200 Greater than 500 square feet . . . . . $200 plus $58 for each additional 100 square feet or fraction thereof above 500 square feet Exceptions: 1. For new construction of one- or two-family dwellings: Each building . . . . . $1,050 2. For additions and structures accessory to existing one- and two-family dwellings: 500 square feet or less . . . . . $60 Greater than 500 square feet . . . . . $60 plus $45 for each additional 100 square feet or fraction thereof above 500 square feet 3. For modular construction of one- and two-family dwellings pursuant to the Manufactured Housing Construction and Safety Standards Authorization Act, Act 192 of 1982, P.L. 676 (35 P.S. §§ 1656.1 – 1656.9) and the Industrialized Housing Act, Act 70 of 1972, P.L. 286 (35 P.S. §§ 1651.1 – 1651.12) respectively, the building permit fee shall be four hundred fifty dollars ($450) per building. 4. For construction of industrialized buildings other than one- and two-family dwellings pursuant to the Industrialized Housing Act, Act 70 of 1972, P.L. 286 (35 P.S. §§ 1651.1 - 1651.12) and related rules and regulations, the building permit fee shall be nine hundred dollars ($900) per building. 5. For initial tenant fit-out of a newly constructed building the fee shall be thirteen dollars ($13) per 100 square feet or fraction thereof with a minimum fee of one hundred fifty dollars ($150). 6. For installation of solar collection panels and related support structure per building . . . . . $200 For alterations and repairs, including the installation of decks: 500 square feet or less . . . . . $200 Greater than 500 square feet . . . . . $200 plus $48 for each additional 100 square feet or fraction thereof above 500 square feet Exceptions: 1. For one- or two-family dwellings: 500 square feet or less . . . . . $60 Greater than 500 square feet . . . . . $60 plus $45 for each additional 100 square feet or fraction thereof above 500 square feet 2. For alterations and repairs, the permit fee shall, at the applicant's selection, be based upon two percent (2%) of the contract value for construction regulated by the Building, Fuel Gas and Mechanical Codes, when such value is substantiated by the submission of a valid contract, except that the minimum fee shall be two hundred dollars ($200). A-902.2.2 Demolition: Fees for permits for complete demolition shall be twenty dollars ($20) per 100 square feet or fraction thereof, but shall not exceed forty thousand dollars ($40,000). The minimum fee shall be two hundred dollars ($200). Exception: For the demolition of non-bearing partitions the fee shall be as follows: In space 4,000 square feet or less . . . . . $60 In space more than 4,000 square feet . . . . . $60 plus $4 per each additional 100 square feet above 4,000 square feet A-902.2.3 Minor Alterations: Where the scope of the work to be performed is limited to the items listed below, the fees shall be as set forth in Sections A-902.2.3.1 through A-902.2.3.5. Exception: The fee for each of the following for a one- or two-family dwelling shall be fifty-five dollars ($55). A-902.2.3.1 For exterior wall covering: 4,000 square feet or less . . . . . $60 More than 4,000 square feet . . . . . $60 plus $4 per each additional 100 square feet above 4,000 square feet A-902.2.3.2 For replacement of roof covering: 4,000 square feet or less . . . . . $60 More than 4,000 square feet . . . . . $60 plus $3 per each additional 100 square feet above 4,000 square feet A-902.2.3.3 For replacement of windows and doors: 20 openings or less . . . . . $60 More than 20 openings . . . . . $60 plus $4 per each additional opening above 20 openings A-902.2.3.4 For replacement of porch or deck flooring having a maximum area of: 200 square feet . . . . . $60 A-902.2.3.5 For the installation of roll-down security gates: For each gate . . . . . $60 A-902.2.4 Foundation-only permits: Fees for permits for the installation of foundations shall be based on the constructed area as follows: 500 square feet or less . . . . . $200 501 to 2,500 square feet . . . . . $350 More than 2,500 square feet . . . . . $600 A-902.2.5 Miscellaneous items: Fees for miscellaneous items shall be as listed below: Exception: The fee for each of the following for one- or two-family dwellings shall be fifty-five dollars ($55). Antennas – Roof- or ground-mounted (each). . . . . $110 Fence walls – Concrete and masonry . . . . . $110 Fences (each) – Non-masonry, exceeding 6 feet high . . . . . $110 Installation, removal or filling with inert material of flammable or combustible liquid storage tanks: (each tank). . . . . $125 Retaining walls more than 2 feet but less than 4 feet above the lower ground level . . . . . $125 Retaining walls 4 feet or more above the lower ground level . . . . . $200 Sidewalk and shelter platforms (each). . . . . $125 Signs: Accessory . . . . . $200 Outdoor advertising devices . . . . . $250 Site preparation (clearing, grubbing and earth movement): Areas not exceeding 15,000 square feet $100 Areas in excess of 15,000 square feet . . . . . $100 plus $5 per each additional 1,000 square feet in excess of 15,000 square feet with a maximum fee of $5,000 Swimming pools . . . . . $200 Tower cranes (when submitted as a separate permit application). . . . . $250 A-902.2.6 Fire Suppression Equipment: For the installation or alteration of fire suppression systems, the fee shall be as follows, except that the minimum fee shall be one hundred fifty dollars ($150): Exception: For the installation of a complete fire sprinkler system within a one- or two-family dwelling the fee shall be one hundred fifty dollars ($150). For each sprinkler head or suppression nozzle . . . . . $12 For the installation of a backflow prevention device on a fire suppression system (where presented as a separate permit). . . . . $125 For each standpipe riser (per floor). . . . . $60 For each yard hydrant . . . . . $60 For each fire pump . . . . . $275 For commercial cooking extinguishing systems (each). . . . . $125 A-902.2.6.1 Minor alterations: Fees for minor alterations to fire suppression systems shall be as listed below: Exception: The fee for a one- or two-family dwelling shall be fifty-five dollars ($55). For relocation of fire sprinklers: 20 sprinklers or less . . . . . $60 More than 20 sprinklers . . . . . $60 plus $4 per each additional sprinkler above 20 A-902.2.7 Mechanical Systems: A-902.2.7.1 For the installation or alteration of mechanical systems with ductwork, including connected appliances, the fee shall be twelve dollars ($12) for each register or diffuser served by the ductwork, except that the minimum fee shall be one hundred fifty dollars ($150). Exception: For the installation of a complete heating and/or cooling system, including fuel gas piping and appliances, within a one- or two-family dwelling, the fee shall be one hundred fifty dollars ($150). A-902.2.7.2 For the installation of fuel gas piping systems and equipment as regulated by the Philadelphia International Fuel Gas Code, including connected appliances, the fee shall be two percent (2%) of the contract value for construction when such value is substantiated by the submission of a valid contract, except that the minimum fee shall be one hundred fifty dollars ($150). Exception: The fee for alterations in a one- or two-family dwelling shall be fifty-five dollars ($55). A-902.2.7.3 For the installation or replacement of appliances regulated by the mechanical code or fuel gas code such as fireplaces (masonry and factory built), boilers, air conditioning units and heat pumps where presented as a separate permit application, the fee shall be one hundred twenty-five dollars ($125) for each appliance. Exception: The fee for one- or two-family dwelling shall be fifty-five dollars ($55) for each appliance. A-902.2.7.4 For the installation of commercial cooking exhaust systems and related components the fee shall be one hundred twenty five ($125) per hood. A-902.2.7.5 Minor alterations: Fees for minor alterations to mechanical systems shall be as listed below: A-902.2.7.5.1 For relocation of HVAC diffusers or registers with flexible connectors: 20 units or less . . . . . $60 More than 20 units . . . . . $60 plus $3 per each additional unit above 20 A-902.2.7.5.2 For direct vent heating apparatus, or warm air heating apparatus installation connected to a flue or chimney: Each unit . . . . . $60 Exception: The fee for one- or two-family dwelling shall be fifty-five dollars ($55) for each apparatus. A-902.2.7.5.3 For the installation of ductwork within a single tenant space and the capacity of the equipment is equal to or less than 2,000 cfm: Each installation . . . . . $60 A-902.2.8 Excavation: The fee for excavation as described in Section A-301.1.1 shall be one hundred three dollars ($103). A-902.2.9 Undetermined items: For items of construction or alteration that are not included in Sections A-902.2.1 through A-902.2.8, the fee shall be two percent (2%) of the total value of construction, but not less than one hundred twenty-five dollars ($125). A-902.3 Construction value: The total value of the construction, when required on permit applications and when used to determine fees, shall include the value of all material, labor, engineering and/or architectural fees, and the overhead and profit cost inherent in the contract, whether or not any such items are provided at no cost. A-902.4 Approval fee schedule: For items submitted to the department for approval, the fees shall be as set forth in Sections A-902.4.1 through A-902.4.3. A-902.4.1 Preliminary review: For the examination of each set of preliminary drawings, specifications and computations: Tenant spaces, individual floors or buildings equal to or less than three stories:. . . . . $350 Each additional story:. . . . . $75 A-902.4.2 New methods and/or materials of construction: For each application for approval of construction material or technique: five hundred dollars ($500) for the initial application and one hundred fifty dollars ($150) for each subsequent year where recurring information is required to be reviewed by the department. A-902.4.3 Approval of revised drawings: For the review of revised drawings subsequent to issuance of the building permit, a fee of twenty dollars ($20) per sheet shall be paid. The fee shall be based on the total number of sheets contained on one of the three sets of revised drawings submitted for review. The minimum fee for such approval is seventy-five dollars ($75). Exception: The fee for the review of revised drawings submitted for existing owner occupied one- or two- family dwellings, including those that contain a Family Day Care Home shall be twenty-five dollars ($25). A-902.5 Appeals: For an appeal to the Board of Building Standards to request a variance, the fee schedule is as follows: Note: For the purpose of calculating the fee for an appeal to the Board of Building Standards, a story shall be any level of floor area either at, above or below grade. For existing one- or two-family dwellings, including those that contain a Family Day Care Home:. . . . . $50 For all buildings other than existing one- or two-family dwellings, the fee schedule is based on the building area affected by the refusal, as follows: Less than five stories in height and less than 30,000 square feet aggregate floor area . . . . . $200 Five or more stories in height or more than 30,000 square feet aggregate floor area . . . . . $600 For special hearings before the Board of Building Standards . . . . . $1,700 A-902.6 Certificate fee schedule: For items where the department issues certifications, the fees shall be as set forth in Sections A-902.6.1 through A-902.6.5. These fees shall be paid at the time of filing the application. A-902.6.1 Certificate of occupancy: For the issuance of a Certificate of Occupancy the fee schedule is as follows: As part of the Building Permit . . . . . No Fee Application for a "Certificate of Occupancy" only . . . . . $200 Application for a "Temporary Certificate of Occupancy" for a permitted construction project . . . . . $300 Application for a "Temporary Certificate of Occupancy" for a special event . . . . . $400 A-902.6.2 Flood plain location certificate: For the written certification of the location of a property in reference to flood prone areas, the fee shall be fifty dollars ($50). A-902.6.3 Floor load certificates: The fee for the examination of computations to verify maximum live loads specified in floor live load certificates shall be one hundred dollars ($100) for four stories or less plus fifty dollars ($50) for each additional story. A-902.6.4 Special inspection agency and special inspector registration: Fees for the registration of special inspection agencies and special inspectors pursuant to the requirements of Section 9-1306 of the Code ("Special Inspection Agencies and Special Inspectors") shall be established by the Department by regulation. A-902.6.5 Lawful Occupancy sign: For the review of plans for the initial issue of Lawful Occupancy signs when not part of plan review for building permit and/or Certificate of Occupancy, the fee shall be one hundred fifty dollars ($150) per space. [History: Former Section A-902.10 deleted, Bill No. 980760 (approved December 30, 1998). Accelerated plan review is now addressed in Section A-901.10. Amended and former Sections A-902.2.1.1 through A-902.2.1.4 and A-902.7 through A-902.9 deleted, Bill No. 000348 (approved August 11, 2000). Amended, Bill No. 030780 (approved December 31, 2003).] [History: These versions of Sections A-902.2 and A-902.2.1 are effective January 1, 2001. See Section 4, Bill No. 000348 (approved August 11, 2000). For the versions of Sections A-902.2 and A-902.2.1 effective until January 1, 2001, see Bill No. 000348. Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the Ordinance shall be effective January 1, 2003. Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 080853 (approved December 8, 2008).] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Added, Bill No. 190785 (approved November 6, 2019).] [History: Amended, Bill No. 080165 (approved June 18, 2008); amended, Bill No. 080853 (approved December 8, 2008).] [History: Amended, Bill No. 080165 (approved June 18, 2008); amended, Bill No. 090842 (approved January 13, 2010).] [History: Amended, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 130691-A (approved February 19, 2014). See note 87 for effective date provisions.] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Amended, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 080165 (approved June 18, 2008).] [History: Amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the amendment shall be effective January 1, 2003. Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 070821 (approved November 15, 2007); amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Amended, Bill No. 080853 (approved December 8, 2008).] [History: Amended, Bill No. 070821 (approved November 15, 2007).] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the amendment shall be effective January 1, 2003. Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 070821 (approved November 15, 2007).] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Amended, Bill No. 080165 (approved June 18, 2008).] [History: Added, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] [History: Amended, Bill No. 070821 (approved November 15, 2007); renumbered and amended, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] [History: Amended, Bill No. 110829 (approved December 21, 2011); amended, Bill No. 190785 (approved November 6, 2019).] [History: Amended, Bill No. 110844 (approved December 21, 2011), effective August 22, 2012.] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 150472 (approved June 30, 2015).] SECTION A-903 ELECTRICAL CODE FEES A-903.1 General: Fees for permits and licenses related to activity regulated by the Electrical Code shall be as set forth in this Section. All application fees for licenses under this Section shall be credited toward the annual license fee if the license is issued. A-903.2 Electrical permit fees: The permit fee for electrical work shall be twenty-five dollars ($25) for each one thousand dollars ($1,000) or fraction thereof of estimated electrical construction costs. The minimum fee shall be fifty dollars ($50). The maximum fee shall be fifteen thousand dollars ($15,000). Except as provided in Section A-903.2.1, the construction costs shall be determined by inclusion of the following: 1. All electrical equipment, conductors, conduit, etc., 2. All material, 3. All labor, 4. Overhead and profit. A-903.2.1 Calculation of construction costs for solar electric (also known as photovoltaic) systems. A-903.2.1.1 Solar electric system or photovoltaic system defined: For the purposes of this subsection, the terms "solar electric system" and "photovoltaic system" shall each mean the total components and subsystems that, in combination, convert solar energy into electrical energy suitable for connection to a utilization load. A-903.2.1.2 For the purpose of calculating the electrical permit fee, the electrical construction costs for any project that includes installation of a solar electric or photovoltaic system shall not include the cost of any arrays or inverters used in the installation of such systems. A-903.3 Electrical inspection agency license: The license fee for an electrical inspection agency shall be two thousand dollars ($2,000), payable annually. In addition to the license fee there shall be a non-refundable initial application fee of two hundred dollars ($200). A-903.4 Electrical inspector license: The fees for obtaining and renewing a license as an electrical inspector shall be as follows: 1. Non-refundable application fee:. . . . . $60 2. Initial license and annual renewals:. . . . . $100 A-903.5 Electrical contractor license: The fees for obtaining and renewing a license as an electrical contractor shall be as follows: 1. Non-refundable application fee:. . . . . $60 2. Initial license and annual renewals:. . . . . $160 The application fees are in addition to any fees charged by an agency which the department authorizes to administer the examination. [History: Amended and Section A-903.2.3 deleted, Bill No. 000348 (approved August 11, 2000); amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 110533 (approved November 14, 2011).] [History: Added, Bill No. 110533 (approved November 14, 2011).] [History: Amended, Bill No. 080853 (approved December 8, 2008).] SECTION A-904 FIRE CODE FEES A-904.1 General: Fees for permits, licenses, appeals and services related to activity regulated by the Fire Code shall be as set forth in this Section. All application fees for licenses under this Section shall be credited toward the annual license fee if the license is issued. A-904.2 Operational permit: The fee for an Operational Permit shall be based on the operations listed in Section F-105.6 of the Fire Code as follows: 1. Cutting, welding and other open burning (not licensed pursuant to A-904.4). . . . . $75 per property 2. Temporary membrane structures, tents and canopies (to include any required Lawful Occupancy Signs). . . . . $100 per tent 3. Use of explosives . . . . . $150 per event 4. Sale of fireworks . . . . . $150 per property A-904.3 Assisted operation permit: The fee for an Assisted Operation Permit for fireworks and other pyrotechnic displays shall be three hundred fifty dollars ($350) per event. A-904.4 Trade license: The annual fee for a Trade or Practice License shall be as follows: 1. Fire Suppression Systems Contractor. a. Non-refundable application fee of one hundred dollars ($100). b. Annual license fee of two hundred fifty dollars ($250). 2. Fire Alarm Systems Inspector. a. Non-refundable application fee of one hundred dollars ($100). b. Annual license fee of two hundred twenty-five dollars ($225). 3. Welding or Cutting Operations. a. Non-refundable application fee of one hundred dollars ($100). b. Annual license fee of one hundred dollars ($100). 4. Wrecking and salvage yards, tire storage facilities, junk yards and waste material handling facilities. a. Non-refundable application fee of one hundred dollars ($100). b. Annual license fee of three hundred dollars ($300). 5. Repair garages and motor fuel dispensing facilities. a. Non-refundable application fee of one hundred dollars ($100). b. Annual license fee of two hundred dollars ($200). A-904.5 Family Child Day Care Home: The fee for a Family Child Day Care Home License application and examination shall be fifty dollars ($50). A-904.6 Miscellaneous fees: The fees for services established by, or related to enforcement of the Fire Code shall be as follows: 1. Appeal to the Board of Safety and Fire Prevention . . . . . $150 per building 2. Lawful Occupancy Sign (See A-902.6.5 for initial issuance). . . . . $25 for replacement of a previously issued sign 3. High-Rise Building Inspection Fee . . . . . $0.01 per square foot per year 4. Regulated Facility (Tier II) Hazardous Chemical Fee . . . . . $75 per chemical per year 5. Regulated Facility (Tier II) Emergency Planning Fee . . . . . $100 per year A-904.7 Hazardous Material Handling License. The annual fee for a Hazardous Material Handling License shall be as follows: Per building or yard . . . . . $200 [History: Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 080853 (approved December 8, 2008); amended, Bill No. 090842 (approved January 13, 2010).] [History: Amended, Bill No. 090842 (approved January 13, 2010).] [History: Added, Bill No. 090842 (approved January 13, 2010).] SECTION A-905 PLUMBING CODE FEES A-905.1 General: Fees for permits and licenses issued by the department related to activity regulated by the Plumbing Code shall be as set forth in this Section. A-905.2 Fixture defined: For the purposes of this Section, the term "fixture" shall mean: A receptacle or device that is connected to a water supply system or discharges to a drainage system or both. Such receptacles or devices require a supply of water; or discharge liquid waste or liquid-borne solid waste; or require a supply of water and discharge waste to a drainage system. A-905.3 Plumbing permit fees: The permit fee for plumbing work shall be as specified in Sections A-905.3.1 through A-905.3.4. A-905.3.1 New building construction and additions: The permit fee for construction of plumbing systems in new buildings or additions shall be two hundred twenty-five dollars ($225) for the first seven fixtures plus twenty dollars ($20) for each additional fixture, which permit shall authorize the installation of all plumbing for the new construction or addition, including area drains, roof drains, water distribution pipe, building or house drain, building sewer, building trap and lateral when presented as part of a single permit application. Exceptions: 1. The permit fee for the construction of plumbing in additions to a one- or two-family dwelling shall be forty dollars ($40) for the first seven fixtures plus eighteen dollars ($18) for each additional fixture, which permit shall authorize the installation of all plumbing for the addition. 2. The permit fee for construction of plumbing systems that are not parts of structures containing fixtures, such as storm drainage systems, irrigation systems, and other similar systems not directly serving a structure shall be two hundred twenty-five dollars ($225). 3. The permit fee for new underground water distribution and drainage systems when submitted as a separate permit application shall be two hundred dollars ($200). A-905.3.2 Alterations of existing buildings: The permit fee for construction or reconstruction of plumbing in existing buildings shall be one hundred fifty dollars ($150) for the first seven fixtures and eighteen dollars ($18) for each additional fixture. Such work shall not include replacement of water distribution, building or house drain, building sewer, lateral or building trap. Exception: The fee for the first seven fixtures in a one- or two-family dwelling shall be forty dollars ($40) and for each additional fixture the fee shall be eighteen dollars ($18). A-905.3.3 Water distribution: The permit fee for the replacement of water distribution pipe from the curb stop or wells to the interior of the building shall be one hundred dollars ($100). A-905.3.4 Repair/replacement: For the repair or replacement of the existing individual plumbing items listed below, the fee shall be as follows: Water and/or waste lines, including stacks . . . . . $100 for each pipe repaired or replaced Exception: The fee for a one- or two-family dwelling shall be thirty dollars ($30). House drains, traps and fresh air inlets . . . . . $60 Area drains, storm drains and roof drains . . . . . $60 Laterals . . . . . $75 Water heater . . . . . $30 Fixture replacement (no piping). . . . . $60 for first seven fixtures plus $5 for each additional fixture Exception: The fee for a one- or two-family dwelling shall be twenty-five dollars ($25). [History: Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the amendment shall be effective January 1, 2003. Amended, Bill No. 070821 (approved November 15, 2007).] SECTION A-906 PROPERTY LICENSE FEES A-906.1 General: Fees for licenses related to activity regulated by Chapter 9-3900 ("Property Licenses and Owner Accountability") shall be as set forth in this Section. A-906.2 Rental license: The annual license fee for a rental license issued under Section 9-3902 shall be fifty-five dollars ($55) for each dwelling or rooming unit with a maximum annual fee of twenty-two thousand dollars ($22,000) per dwelling. A-906.2.1 Owner unit exemption: For two-family dwellings, the fifty-five dollar ($55) license fee is waived for a dwelling unit occupied by an owner listed on the title deed to the property. A-906.2.2 Agency fee: The maximum annual aggregate fee paid by an agency or authority in the business of providing low cost or public housing shall be two hundred fifty thousand dollars ($250,000). A-906.3 Vacant property license: The annual license fee for a vacant lot license issued under Section 9-3904, for a vacant structure license issued under Section 9-3905, or for a vacant waterfront structure license issued under Section 9-3906, shall be one hundred sixty dollars ($160). A-906.4 Removal of exemption: The license for the proper number of units shall be obtained and the related fee paid not later than ten days following the vacating by an owner of a unit exempted by Section A-906.2.1. A-906.5 Limited lodging operator license: The annual license fee for a Limited Lodging Operator License issued under Section 9-3909 is one hundred fifty dollars ($150). A-906.6 Limited lodging and hotels booking agent license: The initial license fee for a Limited Lodging and Hotels Booking Agent License issued under Section 9-3910 is seven thousand dollars ($7,000). The annual license renewal fee is five thousand dollars ($5,000). [History: Amended, Bill No. 990158 (approved June 25, 1999); amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the amendment shall be effective January 1, 2003. Amended, Bill No. 080853 (approved December 8, 2008); amended, Bill No. 150008 (approved March 10, 2015), effective July 1, 2015.] [History: Amended, Bill No. 140856 (approved December 19, 2014), effective July 1, 2015.] [History: Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 000712 (approved April 18, 2001); amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the amendment shall be effective January 1, 2003. Amended, Bill No. 030780 (approved December 31, 2003); amended, Bill No. 080853 (approved December 8, 2008); amended, Bill No. 090842 (approved January 13, 2010); amended, Bill No. 100162 (approved July 29, 2010); amended, Bill No. 110084 (approved March 16, 2011). Section 3 of Bill No. 110084 provides: "This Ordinance shall be effective for calendar year 2011 and thereafter." Amended, Bill No. 170167 (approved April 4, 2017), effective July 1, 2017.] [History: Amended, Bill No. 020758 (approved January 31, 2003). Section 3 of Bill No. 020758 provides that the amendment shall be effective January 1, 2003. Amended, Bill No. 030780 (approved December 31, 2003).] [History: Added, Bill No. 210081 (approved June 23, 2021), effective April 1, 2022.] [History: Added, Bill No. 210081 (approved June 23, 2021), effective April 1, 2022.] SECTION A-907 ZONING FEES A-907.1 General: The fees to be paid under the requirements of Title 14 (relating to Zoning) shall be as set forth in this Section, except that: 1. No permit fees shall be required of any person applying for a use registration permit for a family day care or group day care, as defined in Title 14 ; and 2. No fee shall be required of any person filing an appeal to the Zoning Board of Adjustment, pursuant to Section 14-303, from a decision of the Department of Licenses and Inspections denying a use registration permit for family day care or group day care, as defined in Title 14 . Notwithstanding the foregoing exception, Zoning Board of Adjustment fees shall be required to be paid for accelerated hearings, administrative review and reposting of notices of hearing, pursuant to Section A-907.1.2. A-907.1.1 Permit fees: The schedule of fees for permits that are issued pursuant to the requirements of Title 14 shall be as follows: 1. Zoning Permits: New construction of one- or two-family dwelling . . . . . $150 New construction of structure other than one- or two-family dwellings . . . . . $500 Zoning revisions to lots containing existing one- or two-family dwellings . . . . . $40 Zoning revisions to all other parcels equal to or less than 30,000 square feet . . . . . $200 Zoning revisions to all other parcels greater than 30,000 square feet . . . . . $500 Complete demolition of all structures on a parcel . . . . . $50 2. Use Registration Permits: For each use in new construction and for each use change in an existing structure . . . . . $150 3. Accessory sign permit . . . . . $200 4. Non-accessory (outdoor advertising) sign permit . . . . . $315 5. Preliminary zoning permit review or conditional zoning approval . . . . . $350 6. Additional fee where floor area and height bonuses are applied pursuant to Section 14-702 . . . . . $200 per bonus A-907.1.2 Zoning Board of Adjustment fees: The fees for matters that are taken before the Board pursuant to Section 14-303 and regulations promulgated thereto shall be as follows: 1. For properties containing an existing one- or two-family dwelling only, including any affordable housing project . . . . . $125 2. For any property not included in subsection 1, including any affordable housing project . . . . . $811 3. For each accelerated hearing before the Board, in addition to the fee specified in 1 or 2 above . . . . . $995 4. Fees under 1, 2, and 3 above are per property. 5. For any affordable housing project, as defined in Section A-106, fees shall not exceed one hundred twenty-five dollars ($125) per property and the accelerated hearings fees set forth in 3 above shall be waived. 6. The maximum accelerated hearing fee for simultaneous hearings resulting from multiple permit applications shall be two thousand nine hundred eighty-five dollars ($2,985), provided that the accelerated fee for any application for an affordable housing project shall be zero dollars ($0). 7. An accelerated hearing shall be scheduled by the Zoning Board at the first available date as determined by the Zoning Board. 8. To request a Zoning Board of Adjustment administrative review, as provided by Zoning Board regulations . . . . . $265 9. For a reposting of notices of Zoning Board of Adjustment hearings . . . . . $177 10. To stay issuance of a final disposition by the Zoning Board while the applicant pursues an amendment of the subject zoning application . . . . . $151 11. Zoning Board of Adjustment fee revisions: The Zoning Board of Adjustment, by regulations effective on or after July 1, 2026, is authorized to revise the fees established in this Section A-907.1.2, based upon the costs to administer the applicable hearings and services; provided that no fee shall be increased to an amount higher than the fee as it existed on July 1, 2026, multiplied by the CPI Multiplier, as defined in Section 9-102 of the Code; and further provided that for fees established in this Code after July 1, 2026, the fee shall not be increased to an amount higher than the fee on the date that it was established, multiplied by the CPI Multiplier, using as the base figure for purposes of determining the CPI Multiplier the most recently published CPI-U as of July 1 of the year the fee was established. A schedule of all current fees for matters that are taken before the Zoning Board of Adjustment shall be maintained on the Board’s website. A-907.1.3 Administrative services fees: The fees for the review or approval of documents by the Department that are required pursuant to local or state law shall be as follows: 1. Certification of Zoning District Classification . . . . . $110 2. Application for a "Certification Statement" required for transfer of real estate pursuant to Pennsylvania Act 652 of 1961 . . . . . $110 3. For certification that a permit is not required . . . . . $30 [History: Amended, Bill No. 140944 (approved March 10, 2015).] [History: Amended, Bill No. 250043 (became law September 11, 2025); amended, Bill No. 260203 (approved June 11, 2026), effective July 1, 2026.] [History: Added, Bill No. 120897 (approved January 14, 2013).] [History: Subsection 4 deleted, Bill No. 120774-A (approved January 14, 2013).] CHAPTER 10 WORK SITE PUBLIC SAFETY, WORKER TRAINING IDENTIFICATION, AND SIGNAGE [History: Added, Bill No. 130847-A (approved February 19, 2014), effective within 18 months (August 19, 2015).] SECTION A-1001 GENERAL A-1001.1 Definitions: The following definitions apply to this Chapter: "Major Building." A building that is either: 1. More than 3 stories in height; or 2. More than 40 feet (12 192 mm) in height; or 3. Covers 10,000 square feet (929 m2) or more of lot space, regardless of height. A-1001.2 Scope: 1. The provisions of this Chapter shall evidence training compliance of all construction or demolition workers. These provisions are designed to save lives and enhance the public safety of all citizens in, around or near a construction or demolition site. For rules relating to the safety of persons employed in construction or demolition operations, OSHA standards shall apply. 2. Nothing in this Chapter shall be construed to relieve persons engaged in construction or demolition operations from complying with other applicable provisions of law, nor is it intended to alter or diminish any obligation otherwise imposed by law on the owner, construction manager, general contractor, contractors, material men, registered design professionals, or other party involved in a construction or demolition project to engage in sound design and engineering, safe construction or demolition practices, including but not limited to debris removal, and to act in a reasonable and responsible manner to maintain a safe construction or demolition site and to follow all other rules, regulations and laws. A-1001.3 Department duties: 1. The Department shall ensure that all construction and demolition workers have completed the training required under this Chapter. 2. The Department shall accept a wallet sized identification card or other written proof issued by the training provider, as confirmation of completion of an approved training course and as proof that a construction or demolition worker has successfully completed the training required under this Chapter. At a minimum the card shall include the name of the applicant an issue date and the level of training completed. A-1001.4 Worker training requirements: 1. In order to protect public safety, all workers performing duties at a construction or demolition site, regardless of their position, shall have completed a course of OSHA 10 training, and carry the card at all times. 2. All independent contractors working at a demolition site shall be licensed in accordance with Chapter 9-1000 of The Philadelphia Code. 3. The worker training requirements of this Section shall apply only to persons performing construction or demolition activities for which a permit must be obtained, and do not apply to delivery persons, design professionals and their staff, special inspectors and similar persons performing duties at a construction or demolition site whose work is not considered construction or demolition work regulated by a permit. 4. A licensed contractor who employs any such worker shall maintain a copy of such written proof for each worker under his/her employ on file and make it available to the Department upon request. A-1001.5 Site Safety Manager: A Site Safety Manager with OSHA 30 training must be designated by the general contractor and present during the construction or demolition of a Major Building. A-1001.6 Contractor: Contractors, construction managers, and subcontractors engaged in building or demolition work shall institute and maintain work site public safety measures that will adequately protect the general public from harm, in addition to any OSHA requirements, and provide all equipment or temporary construction necessary to safeguard all persons and property affected by such contractor's operations. A-1001.7 Work site signage: A-1001.7.1 Sign requirements: Signs shall be posted at all construction or demolition sites in accordance with this Section. A-1001.7.2 Project information panel sign for major buildings: The signs required in this Section shall be constructed of 3/4 inch plywood or sheet metal. The letters on the required signs shall be black on white background, with lettering of at least 1.5 inches in height. The sign shall be prominently posted onsite in an area reasonably likely to draw the attention of persons passing by. A Project Information Panel sign shall be posted at all sites of new construction, structural alteration or demolition of Major Buildings containing the following information: (a) A rendering, elevation drawing, or zoning diagram of the building exterior that does not contain logos or commercially recognizable symbols; (b) A title line stating "Work in Progress" and specifying the intended type(s) of Building Code Occupancy Classification(s); (c) Anticipated project completion date; (d) The name or corporate name, physical address, and telephone number of the owner of the property. If the owner is not a natural person or a publicly traded company, the sign shall also include, in addition to the owner of the property, the name and preferred mailing address of each natural person who has an equity interest in such owner or owners of the property that exceeds one or more of the following, regardless of whether the natural person has a direct equity interest or such natural person's equity interest is held through one or more tiers of a corporate structure, such as parent-subsidiary structure: (a) forty-nine percent (49%) of the value of the property or (b) forty-nine percent (49%) of the value of the owner of the property. If no natural person has such an interest, the sign shall identify the name and preferred mailing address of the two natural persons who have the largest equity interest in the property; (e) Website and telephone number of the project developer or development company, if applicable; (f) The corporate name and telephone number of the general contractor, or for a demolition site, the demolition contractor; (g) A statement, in both English and Spanish printed as follows: "TO ANONYMOUSLY REPORT UNSAFE CONDITIONS AT THIS WORK SITE, CALL 311 or 911."; and (h) A copy of the primary project permit or notice of permit issued by the Department, with the accompanying text: "To see other permits issued on this property, call 311 or visit www.phila.gov/li." The permit or notice of permit issued by the Department shall be laminated or encased in a plastic covering to protect it from the elements or shall be printed directly onto the project information panel. Exceptions: 1. A rendering, elevation drawing, or zoning diagram of the building exterior is not required for demolition projects. 2. This Section A-1001.7.2 shall not apply to new construction, structural alteration or demolition of a one-family or two-family dwelling, unless a project consists of the construction, alteration or demolition of more than two such dwellings. A-1001.7.3 Project information sign for all other buildings: The signs required in this Section shall be printed by the Department on paper no smaller than 11 inches x 17 inches. The letters on the required sign shall be black on yellow background. The sign shall be prominently posted onsite in an area reasonably likely to draw the attention of persons passing by. This sign shall be posted at all sites of new construction, structural alteration or demolition of all buildings that are not required to post a project information panel pursuant to Section A-1001.7.2, and shall contain the following information: (a) A title line stating "Work in Progress" and specifying the intended type(s) of Building Code Occupancy Classification(s); (b) Anticipated project completion date; (c) The name or corporate name, physical address, and telephone number of the owner of the property. If the owner is not a natural person or a publicly traded company, the sign shall also include, in addition to the owner of the property, the name and preferred mailing address of each natural person who has an equity interest in such owner or owners of the property that exceeds one or more of the following, regardless of whether the natural person has a direct equity interest or such natural person's equity interest is held through one or more tiers of a corporate structure, such as parent-subsidiary structure: (a) forty-nine percent (49%) of the value of the property or (b) forty-nine percent (49%) of the value of the owner of the property. If no natural person has such an interest, the sign shall identify the name and preferred mailing address of the two natural persons who have the largest equity interest in the property; (d) The corporate name and telephone number of the contractor of record on the primary project permit, or for a demolition site, the demolition contractor; (e) A statement, in both English and Spanish printed as follows: "TO ANONYMOUSLY REPORT UNSAFE CONDITIONS AT THIS WORK SITE, CALL 311 or 911."; (f) A statement printed as follows: "To see other permits issued on this property, call 311 or visit www.phila.gov/li."; and (g) Whether the project scope includes an excavation exceeding a depth of five feet below adjacent grade, excluding digging, trenching, or boring for utilities or geotechnical exploration, and is within ten feet of an existing structure. A-1001.8 Preconstruction meetings: Before construction or demolition of a building begins, the Department may require that the responsible contractors attend a meeting with representatives of city departments to review the schedule of operations and safety protections for the project. [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Regulations implementing Section A-1001.7 were promulgated on June 20, 2014 and became effective on July 21, 2014. Section A-1001.7 therefore became effective on July 21, 2014.] [History: Amended, Bill No. 200417 (became law November 12, 2020).] [History: Amended, Bill No. 180175 (approved June 6, 2018).] [History: Amended, Bill No. 160468 (approved June 28, 2016).] [History: Amended, Bill No. 160468 (approved June 28, 2016).] [History: Amended, Bill No. 200417 (became law November 12, 2020).] [History: Added, Bill No. 210389 (approved July 15, 2021), effective January 1, 2023.] CHAPTER 11 REQUIREMENTS CONCERNING RAT ABATEMENT [History: Added, Bill No. 210902 (approved March 2, 2022).] SECTION A-1101 GENERAL A-1101.1 Definitions: The following definitions apply to this Chapter: "Structural Pest Control." The control of household pests, including but not limited to rodents, vermin and insects which may invade households or structures. A-1101.2 Requirements prior to demolition, full rehabilitation, or new construction with excavation: Prior to any demolition, full rehabilitation, or new construction with excavation, the owner of the site shall prepare a rodent control management plan for the detection, inspection, and treatment of rodents at the site. At a minimum, the plan shall include provisions for abatement of the site by a licensed structural pest control company. A-1101.3 Record maintenance: The owner of the site shall maintain a written record of the plan and any pest control measures performed by pest management professionals at the site and include any reports and receipts prepared by the structural pest control company. The plan and records shall be maintained at the site until construction is completed and shall be open to inspection upon request by employees of the department. A-1101.4 The Department of Public Health and the Department of Licenses and Inspection is authorized to issue regulations to implement and enforce this Chapter. SUBCODE "B" (THE PHILADELPHIA BUILDING CODE) Article B-1.0 Adoption of the “2021 International Building Code”, pursuant to the Pennsylvania Uniform Construction Code Act (“Act”), with state amendments and local amendments that were in effect prior to enactment of the Act or approved pursuant to Section 503 of the Act. § B-1.1 The “2021 International Building Code”, as published by the International Code Council (copies of which are on file with the Department of Licenses and Inspections) is hereby adopted as the Philadelphia Building Code and is hereby incorporated as if fully set forth herein, subject to the following local amendments provided in this Subcode “B”. Editor’s note: The 2021 International Building Code can be found at: https://codes.iccsafe.org/content/IBC2021V2.0 § B-1.1.1 The numbers of all state and local amendments shall be preceded with the prefix “B-”. § B-1.1.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. [History: Added, Bill No. 970038 (approved March 19, 1997); repealed and replaced, Bill No. 030779 (approved December 31, 2003); repealed and replaced, Bill No. 180176 (approved June 6, 2018). Section 7 of Bill No. 180176 provides: "The provisions of this Ordinance shall be effective October 1, 2018, and upon taking effect replace and supersede previously adopted Regulations of the Department of Licenses and Inspections related to Subcode B and Subcode M." Repealed and replaced, Bill No. 260394 (approved June 12, 2026), effective July 1, 2026.] CHAPTER 1 SCOPE AND ADMINISTRATION [Delete the contents of this Chapter and substitute the following.] SECTION B-101 GENERAL B-101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Building Code and will be referred to herein as the “Philadelphia Building Code” or “this code”. B-101.2 Scope. The provisions of the Philadelphia Building Code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal, and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures shall comply with the Philadelphia Residential Code (Subcode R). B-101.2.1 Appendices. Appendices E, F, G, H, and I are hereby adopted. B-101.3 Intent. The purpose of this code is to establish the minimum requirements to provide a reasonable level of safety, public health and general welfare through structural strength, means of egress facilities, stability, sanitation, adequate light and ventilation, energy conservation, and safety to life and property from fire, explosion and other hazards, and to provide a reasonable level of safety to fire fighters and emergency responders during emergency operations. B-101.4 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are as set forth in the Philadelphia Administrative Code. B-101.5 Existing buildings. The provisions of the Philadelphia Existing Building Code shall apply to matters governing the repair, alteration, change of occupancy, addition to, and relocation of existing buildings. CHAPTER 2 DEFINITIONS SECTION 202 DEFINITIONS [Add the following definition] COOL ROOF RATING COUNCIL (or CRRC): The Cool Roof Rating Council, Inc., an American National Standards Institute-accredited standards developer organization that created, maintains, and updates the ANSI/CRRC S100 standard, entitled “Standard Test Methods for Determining Radiative Properties of Materials.” * * * [Delete the definition of Flammable Gas and replace as follows:] [F] FLAMMABLE GAS. A material that is a gas at 68°F (20°C) or less at 14.7 pounds per square inch atmosphere (psia) (101 kPa) of pressure [a material that has a boiling point of 68°F (20°C) or less at 14.7 psia (101 kPa)] subdivided as follows: 1. Category 1A. A gas that meets either of the following: a. Ignitable at 14.7 psia when in a mixture 13 percent or less by volume with air. b. A flammable range at 14.7 psia (101kPa) with air of at least 12 percent, regardless of the lower limit, unless data shows compliance with Category 1B. 2. Category 1B. A gas that meets the flammability criteria for Category 1A, is not pyrophoric or chemically unstable, and meets one or more of the following: a. A lower flammability limit of more than 6 percent by volume in air; or b. A fundamental burning velocity of less than 3.9 in/s (10 cm/s) The limits specified shall be determined at 14.7 psi (101 kPa) of pressure and a temperature of 68°F (20°C) in accordance with ASTM E681. Where not otherwise specified, the term “flammable gas” includes both Category 1A and Category 1B. * * * CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION * * * SECTION 305 EDUCATIONAL GROUP E * * * 305.2 Group E, day care facilities. * * * [Pursuant to the UCC, delete Section 305.2.3 and replace as follows:] B-305.2.3 Twelve or fewer children in a dwelling unit. A facility such as the above within a dwelling unit and having twelve or fewer children receiving such day care shall be classified as a Group R-3 occupancy and shall comply with the provisions of Section B-429 of this code. * * * SECTION 307 HIGH-HAZARD GROUP H * * * [Revise Table B-307.1(1), Maximum Allowable Quantity Per Control Area of Hazardous Materials Posing a Physical Hazard, by deleting the “Flammable Gas” rows “Gaseous” and “Liquified” and replacing with the following, including the addition of note “r,” as follows:] Material | Class | Group when the maximum allowable quantity is exceeded | Storage b | Use-closed systems | Use-open systems Solid pounds (cubic feet) | Liquid gallons (pounds) | Gas (cubic feet at NTP) | Solid pounds (cubic feet) | Liquid gallons (pounds) | Gas (cubic feet at NTP) | Solid pounds (cubic feet) | Liquid gallons (pounds) Flammable Gas | * * * Gaseous 1A and 1B (High BV) r | H-2 | NA | NA | 1,000 d, e | NA | NA | 1,000 d, e | NA | NA 1B (Low BV) r | 162,500 d, e | 162,500 d, e Liquified 1A and 1B (High BV) r | H-2 | NA | (150) d, e | NA | NA | (150) d, e | NA | NA | NA 1B (Low BV) r | (10,000) d, e | (10,000) d, e * * * | | | | | | | | | | r. “High BV” Category 1B flammable gas has a burning velocity greater than 3.9 in/s (10 cm/s). “Low BV” Category 1B flammable gas has a burning velocity of 3.9in/s (10 cm/s) or less. * * * [F] B-307.4 High Hazard Group H-2. Buildings and structures containing materials that pose a deflagration hazard or a hazard from accelerated burning shall be classified as Group H-2. Such materials include, but not limited to, the following: * * * [Replace “Flammable Gases” with the following:] Category 1A Flammable gases. Category 1B Flammable gases having a burning velocity greater than 3.9 inches per second (10 cm/s). * * * [F] B-307.5 High Hazard Group H-3. Buildings and structures containing materials that readily support combustion or that pose a physical hazard shall be classified as Group H-3. Such materials shall include, but not be limited to, the following: * * * [Add the following:] Category 1B Flammable gases having a burning velocity of 3.9 inches per second (10 cm/s) or less. * * * SECTION 308 INSTITUTIONAL GROUP I * * * B-308.2 Institutional Group I-1. * * * [Add Section B-308.2.5 as follows:] B-308.2.5 Supervised environment. In the determination of what is a supervised environment for the purposes of classifying Group I-1 occupancies, the following description shall be used. Group I-1 applies to the care of residents who do not require chronic or convalescent medical or nursing care. Supervision involves responsibility for the safety of the residents while inside the building. For the purposes of this Section, supervision includes one or more of the following: 1. Daily awareness by the management of the resident’s functioning and whereabouts; Making and reminding a resident of appointments; 2. The ability and readiness for intervention in the event of a resident experiencing a crisis; 3. Supervision in the area of nutrition and medication; and 4. Actual provision of transient medical care. * * * SECTION 310 RESIDENTIAL GROUP R * * * B-310.4 Residential Group R-3. * * * B-310.4.1 Care facilities within a dwelling. * * * [Pursuant to the UCC, add Section B-310.4.1.1 as follows:] B-310.4.1.1 Child day care facilities. A dwelling where child day-care services are provided for less than 24 hours for 12 or fewer children is an R-3 occupancy where the dwelling is used primarily as a private residence and the provision of day care services is accessory to the principal use of the dwelling as a residence (See Section B-429). * * * CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY * * * SECTION 403 HIGH-RISE BUILDINGS * * * 403.5 Means of egress and evacuation. * * * [Delete Section 403.5.3 and replace as follows:] B-403.5.3 Stairway door operation. Stairway doors other than the exit discharge doors shall be permitted to be locked from the stairway side. Stairway doors that are locked from the stairway side shall be capable of being unlocked simultaneously, without unlatching, upon a signal from the fire command center where the fire command center is continuously staffed during any occupancy, or upon power failure. Where the fire command center is not continuously staffed during occupancy, the stairway doors shall unlock upon activation of the building fire alarm system or upon power failure. * * * SECTION 406 MOTOR-RELATED OCCUPANCIES B-406.1 General. * * * [Add Section B-406.1.1 as follows:] B-406.1.1 Ventilation. A mechanical ventilation system shall be provided in open and enclosed public parking garages in accordance with Air Management Regulation XII as promulgated by the City of Philadelphia’s Department of Public Health. * * * SECTION 414 HAZARDOUS MATERIALS * * * [F] 414.2 Control areas. * * * [Delete Section 414.2.5 and replace as follows:] B-414.2.5 Hazardous materials in Group M display and storage areas and in Group Storage areas. Hazardous materials located in Group M and Group S occupancies shall be in accordance with Sections 414.2.5.1 through 414.2.5.4. * * * [Add Table 414.2.5(3) as follows:] B-Table 414.2.5(3) Maximum Allowable Quantity of Low Burning Velocity Category 1B Flammable Gas in Group M and S Occupancies per Control Area a Category 1B (Low BV) d | Maximum Allowable Quantity Per Control Area Sprinklered b | Nonsprinklered Gaseous | 390,000 cu ft | 195,000 cu ft Liquified | 40,000 lb c | 20,000 lb For SI: 1 pound = 0.454 kg, 1 square foot = 0.0929 m2, 1 cubic foot = 0.028 m3, 1 inch/second = 2.54 cm/s a. Control areas shall be separated from each other by not less than a1-hour fire barrier. b. The building shall be equipped throughout with an approved automatic sprinkler system with minimum sprinkler design density of Ordinary Hazard Group 2 in the area where flammable gases are stored or displayed. c. Where storage areas exceed 50,000 square feet in area, the maximum allowable quantities are allowed to be increased by 2 percent for each 1,000 square feet of area in excess of 50,000 square feet, up to not more than 100 percent of the table amounts. Separation of control areas is not required. The aggregate amount shall not exceed 80,000 pounds. d. “Low BV” Category 1B flammable gas has a burning velocity of 3.9 in/s (10 cm/s) or less. * * * [Add Section 414.2.5.4 as follows:] B-414.2.5.4 Flammable gas. The aggregate quantity of Category 1B flammable gas having a burning velocity 3.9 in/s (10 cm/s) or less stored and displayed within a single control area of a Group M occupancy or stored in a single control area of a Group S occupancy is allowed to exceed the maximum allowable quantities per control area specified in Table 307.1(1) without classifying the building or use as a Group H occupancy, provided the materials are stored and displayed in accordance with the International Fire Code and quantities do not exceed the amounts specified in Table 414.2.5(3). * * * [F] 414.5 Inside Storage, dispensing and use. * * * [F] 414.5.1 Explosion Control. * * * [Revise Table B-414.5.1, Explosion Control Requirements, to make an addition to the row “Flammable Gas” to add a note “j” as follows:] Material | Category | Explosion Control Methods Barricade construction | Explosion (deflagration) venting or explosion (deflagration) prevention systems b Hazard Category | * * * Flammable gas | Gaseous | Not required | Required j Liquified | Not required | Required j * * * j. Not required for Category 1B Flammable Gases having a burning velocity not exceeding 3.9 in/s (10 cm/s). * * * SECTION 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING, AND STORAGE * * * [Pursuant to the UCC, delete Section 426.1 and replace as follows:] [F] B-426.1 General. The provisions of Sections 426.1.1 through 426.1.7 shall apply to buildings in which materials that produce combustible dusts are stored or handled. Buildings that store or handle combustible dusts shall comply with NFPA 652 and the applicable provisions of NFPA 61, NFPA 85, NFPA 120, NFPA 484, NFPA 654, NFPA 655 and NFPA 664 and the International Fire Code. * * * [Add Section B-429 as follows:] SECTION B-429 FAMILY CHILD DAY CARE FACILITIES B-429.1 General. Pursuant to the UCC, child day care facilities are permitted to operate in a one- or two- family dwelling unit (home) provided the facility conforms to Sections B-429.1.1 through B-429.4.2. B-429.1.1 Child care facilities within a dwelling unit. A dwelling unit where child day care services are provided for 12 or fewer children shall be classified as an R-3 occupancy and as a Family Child Day Care Facility, provided that it is in accordance with 1 through 4. 1. The dwelling unit is contained within a one- or two-family dwelling. 2. Child day care services are provided for less than 24 hours. 3. The dwelling unit is used primarily as a private residence. 4. The provision of child day care services is accessory to the principal use of the dwelling unit as a residence. 5. The facility shall be operated in accordance with the Philadelphia Fire Code Section F-409. B-429.2 Fire extinguisher. At least one portable fire extinguisher with a minimum rating of 2-A:10-B:C shall be mounted in the portion of the building used for the Family Child Day Care Facility and in kitchens and other cooking areas used by the Family Child Day Care Facility. B-429.3 Six or fewer children. Family Child Day Care Facilities that are classified as Group R-3 occupancies pursuant to Section B-429.1.1 of the Philadelphia Building Code with six or fewer children shall comply with Sections B-429.3.1 through B-429.3.2. B-429.3.1 Smoke alarms. A single-station smoke alarm shall be installed in each story including basements. The smoke alarms shall be powered by either the building wiring system or 10-year, nonremovable batteries, both of which shall be listed by Underwriters Laboratories and shall sound an alarm when activated that is audible to persons in the dwelling unit’s indoor child care spaces with all intervening doors closed. Where battery powered smoke alarms are used, the building owner shall keep the proof and date of purchase of the smoke alarms in the unit’s fire drill logs. B-429.3.2 Means of egress. The dwelling unit and the accessory Family Child Day Care Facility shall comply with the means of egress requirements for an R-3 occupancy and licensure under 55 Pa. Code Chapter 3290 (relating to Family Child Day Care Facilities). B-429.4 Seven to 12 children. Family Child Day Care Facilities that are classified as Group R-3 occupancies pursuant to Section B-429.1.1 of the Philadelphia Building Code that provide child day care services to more than six but no more than 12 children shall comply with Sections B-429.4.1 through B-429.4.2. B-429.4.1 Smoke alarms. Interconnected, multiple-station smoke alarms shall be installed in each story including basements. The smoke alarms shall be powered by the building wiring system and shall sound an alarm when activated that is audible to persons in the dwelling unit’s indoor childcare spaces with all intervening doors closed. B-429.4.2 Means of egress. The dwelling unit and the accessory Family Child Day Care Facility shall comply with the means of egress requirements for an R-3 occupancy and licensure under 55 Pa. Code Chapter 3280 (relating to Group Child Day Care Facilities). * * * [Add Section B-430 as follows:] SECTION B-430 SPECIAL ASSEMBLY OCCUPANCIES B-430.1 General. Assembly Group A occupancies classified as Special Assembly Occupancies shall comply with the additional provisions of this Section. B-430.2 Classification as a Special Assembly Occupancy. An Assembly Group A occupancy shall also be classified as a Special Assembly Occupancy if 50 or more people congregate primarily for social entertainment purposes as defined in Section 9-703 of The Philadelphia Code at such location at one or more times during the course of any year. Such facilities shall include but not be limited to any of the following: nightclub; discotheque; cabaret; tavern; bar; restaurant; private club; banquet hall; and similar place of assembly without primarily fixed seating. B-430.3 Fire alarm. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in all Special Assembly Occupancies. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system as required for the Group E occupancy. Exception: Manual fire alarm boxes are not required in Special Assembly Occupancies where the occupancy is protected throughout with a rate-of-rise heat detection system, provided one manual fire alarm box is installed in a location that is constantly attended by staff during periods of occupancy by the public. B-430.3.1 Activation of the fire alarm. In Special Assembly Occupancies, a shut-off (shunt trip) device shall be provided to automatically shut off electricity to circuits controlling audio equipment in the facility upon activation of the fire alarm system or automatic sprinkler system. * * * CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES * * * SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS * * * [Pursuant to the UCC, revise Section B-704.2 by deleting the exception as follows:] B-704.2 Column protection. Where columns are required to have protection to achieve a fire-resistance rating, the entire column shall be provided individual encasement protection by protecting it on all sides for the full column height, including connections to other structural members, with materials having the required fire-resistance rating. Where the column extends through a ceiling, the encasement protection shall be continuous from the top of the foundation or floor/ceiling assembly below through the ceiling space to the top of the column. Exception: Columns that meet the limitations of Section 704.4.1. * * * 704.4 Protection of secondary structural members. * * * [Pursuant to the UCC, delete Section B-704.4.1 and replace as follows:] B-704.4.1 Light-frame construction. Studs and boundary elements that are integral elements in load-bearing walls of light-frame construction shall be permitted to have required fire-resistance ratings provided by the membrane protection provided for the load-bearing wall. * * * SECTION 711 FLOOR AND ROOF ASSEMBLIES * * * 711.3 Nonfire-resistance-rated floor and roof assemblies. * * * [Add Section B-711.3.3 as follows:] B-711.3.3 Fire protection of floors. Floor assemblies that are not required elsewhere in this code to be fire- resistance rated shall be provided with a 1/2-inch (12.7 mm) gypsum wallboard membrane, 5/8-inch (16 mm) wood structural panel membrane, or equivalent on the underside of the floor framing member. Penetrations or openings for ducts, vents, electrical outlets, lighting, devices, luminaires, wires, speakers, drainage, piping and similar openings or penetrations shall be permitted. Exceptions: 1. Floor assemblies located directly over a space protected by an approved automatic sprinkler system. 2. Floor assemblies located directly over a crawl space not intended for storage or fuel-fired appliances. 3. Portions of floor assemblies shall be permitted to be unprotected where the aggregate area of the unprotected portions does not exceed 80 square feet (7.4 m2) per story. 4. Wood floor assemblies using dimension lumber or structural composite lumber equal to or greater than 2-inch by 10-inch (50.8 mm by 254 mm) nominal dimension, or other approved floor assemblies demonstrating equivalent fire performance. * * * CHAPTER 8 INTERIOR FINISHES * * * SECTION 803 WALL AND CEILING FINISHES * * * [Pursuant to the UCC, delete Section B-803.3 and replace as follows:] B-803.3 Heavy timber exemption. In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3, exposed portions of building elements complying with the requirements for buildings of heavy timber construction in Section 602.4 or Section 2304.11 shall not be subject to interior finish requirements except in interior exit stairways, interior exit ramps, and exit passageways. * * * CHAPTER 9 FIRE PROTECTION SYSTEMS * * * SECTION 903 AUTOMATIC SPRINKLER SYSTEMS * * * [F] 903.2 Where required. [F] 903.2.11 Specific building areas and hazards. * * * [Add Section B-903.2.11.7 as follows:] B-903.2.11.7 Buildings 45 feet or more in height. An automatic sprinkler system shall be installed in the following areas of buildings that have one or more stories located 45 feet (13 716 mm) or more above the lowest level of fire department vehicle access: 1. Basements. 2. The level of exit discharge. Exceptions: 1. Open parking structures. 2. Occupancies in Group F-2. 3. Buildings where all exterior walls have a fire separation distance of 5 feet (1524 mm) or greater. * * * [F] 903.3 Installation requirements. * * * [F] 903.3.1 Standards. * * * [Pursuant to the UCC, delete Section 903.3.1.2 and replace with the following:] [F] B-903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems in Group R occupancies shall be permitted to be installed throughout in accordance with NFPA 13R where the Group R occupancy meets all of the following conditions: 1. Four stories or fewer above grade plane. 2. For other than R-2 occupancies, the floor level of the highest story is 30 feet (9144 mm) or less above the lowest level of fire department vehicle access. For R-2 occupancies, the roof assembly is less than 45 feet (13716 mm) above the lowest level of fire department vehicle access. The height of the roof assembly shall be determined by measuring the distance from the lowest required fire vehicle access road surface adjacent to the building to the eave of the highest pitched roof, the intersection of the highest roof to the exterior wall, or the top of the highest parapet, whichever yields the greatest distance. 3. The floor level of the lowest story is 30 feet (9144 mm) or less below the lowest level of fire department vehicle access The number of stories of Group R occupancies constructed in accordance with Sections 510.2 and 510.4 shall be measured from grade plane. * * * SECTION 907 FIRE ALARM AND DETECTION SYSTEMS * * * [F] 907.2 Where required-new buildings and structures. * * * [F] 907.2.3 Group E. * * * [Add Section B-907.2.3.1 as follows:] [F] B-907.2.3.1 Occupant load of 50 or less. Where a manual fire alarm system is not provided in Group E occupancies with an occupant load of 50 or less, interconnected smoke alarms shall be installed in accordance with Section 907.2.10 and a minimum of one smoke alarm shall be installed in each classroom or child care room. * * * [F] 907.6 Installation and monitoring. * * * [F] 907.6.4 Zones. * * * [Delete Section 907.6.4.1 and replace as follows:] [F] B-907.6.4.1 Zoning indicator panel. A zoning indicator panel and the associated controls shall be provided at a visible location at the main entrance of the building or other location approved by the Fire Department. The visual zone indication shall lock in until the system is reset and shall not be cancelled by the operation of an audible-alarm silencing switch. * * * [Add Section B-919 as follows:] SECTION B-919 EMERGENCY VEHICLE ACCESS B-919.1 Emergency vehicle access. Where control of vehicular access to or on a premises is proposed, the control method shall provide for access by emergency vehicles. A control method shall not be considered an obstruction to emergency vehicle access where it consists of: 1. A padlock and chain, or 2. Collapsible bollards that are painted reflective white and that can be collapsed by use of a Philadelphia standard hydrant wrench. B-919.2 Fire apparatus access roads. Fire apparatus access roads shall be provided in accordance with Section F-503 of the Philadelphia Fire Code. * * * [Add Section B-920 as follows:] SECTION B-920 PRIVATE FIRE HYDRANTS B-920.1 Fire hydrants. Fire hydrants installed on private property shall be located and installed in accordance with Section F-507.5 of the Philadelphia Fire Code and as directed by the Fire Department. Hydrants shall be Philadelphia Standard as specified by the Water Department. Hydrants shall not be installed on a water main less than 6 inches (152 mm) in diameter. * * * CHAPTER 10 DOORS, GATES AND TURNSTILES * * * SECTION 1010 DOORS, GATES AND TURNSTILES * * * 1010.2 Door Operations. * * * 1010.2.4 Locks and latches. * * * [Add Section B-1010.2.4.A as follows:] B-1010.2.4.A Locks and latches. Locks and latches shall be permitted to prevent operation of doors where an elevator lobby is separated from the remainder of the floor by partitions and doors; and where the elevator lobby does not provide access to the required exits, the doors in the lobby partitions are permitted to be locked from the lobby side provided the doors conform to Section 1010.12 or Section 1010.13 with or without delayed locking arrangement. * * * 1010.2.7 Stairway doors. * * * [Add Section B-1010.2.7.1 as follows:] B-1010.2.7.1 Stairway side door locking arrangement. Interior stairway means of egress doors may be openable from only the egress side in stairways serving more than four stories, where the floors served by the stairs are not located more than 75 feet (22 860 mm) above the lowest level of fire department vehicle access nor more than 30 feet (9144 mm) below the lowest level of exit discharge. Such doors are permitted to be locked from the side opposite the egress side, provided they unlock upon activation of the building fire alarm system or power failure to the locking device, and the doors are always openable from the egress side. * * * SECTION 1011 STAIRWAYS * * * 1011.5 Stair treads and risers. * * * 1011.5.2 Riser height and tread depth. * * * [Pursuant to the UCC, delete Section 1011.5.2, Exception 3, and replace as follows:] Exceptions: * * * 3. In Group R-3 occupancies; within dwelling units in Group R-2 occupancies; and in Group U occupancies that are accessory to a Group R-3 occupancy or accessory to individual dwelling units in Group R-2 occupancies; the maximum riser height shall be 8.25 inches (210 mm); the minimum tread depth shall be 9 inches (229 mm); the minimum winder tread depth at the walk line shall be 10 inches (254 mm); and the minimum winder tread depth shall be 6 inches (152 mm). A nosing not less than 3/4 inch (19.1 mm) but not more than 1.5 inches (38 mm) shall be provided on stairways with solid risers where the tread depth is less than 11 inches (279 mm). * * * CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1201 GENERAL [Delete Section 1201.1 and replace as follows:] B-1201.1 Scope. The provisions of this Chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions, surrounding materials, storage of refuse and rodent-proofing associated with the interior spaces of buildings. * * * [Add Section B-1210 as follows:] SECTION B-1210 STORAGE OF REFUSE B-1210.1 General. Provisions for storage of refuse in new and existing buildings shall comply with the provisions of this Section. B-1210.2 New buildings. Newly constructed buildings shall provide an area for storage of refuse where the use of the building will generate refuse, as defined in Section 9-604 of The Philadelphia Code, and where such refuse is to be disposed of by use of a dumpster, as defined in Section 10-722 of The Philadelphia Code. The area of storage shall be located either inside the building or on the premises and enclosed on all sides. B-1210.3 Change of occupancy. For buildings undergoing a change of occupancy, storage of refuse shall be provided in accordance with Section EB-306 of the Philadelphia Existing Building Code. * * * CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES * * * SECTION 1504 PERFORMANCE REQUIREMENTS * * * [Add Section B-1504.9 as follows:] B-1504.9 Reflectance. Roof Coverings over conditioned spaces on low-slope roofs (roof slope < 2:12) on newly constructed buildings and additions to existing buildings shall be rated by the Cool Roof Rating Council as having: 1. a minimum three-year aged solar reflectance of 0.62 and minimum three-year aged thermal emittance of 0.75; or, 2. a minimum Solar Reflectance Index of 75. Exceptions: 1. An addition to a roof that supports living vegetation and includes a synthetic, high quality waterproof membrane, drainage layer, soil layer and light weight medium plants shall be permitted to comprise part or all of the roof area. 2. Walking surfaces of occupiable rooftops. 3. An area including and adjacent to rooftop photovoltaic and solar thermal equipment, totaling not more than three times the area that is covered with such equipment. 4. Limited roof areas as determined by regulations promulgated by the Department of Licenses and Inspections. 5. A roof, the area of which is less than three (3) percent of the gross floor area of the building. 6. Any roof or portion of a roof composed of glass, metal, clay or concrete tile or plastic/rubber intended to simulate clay or concrete tile, wood, or slate. * * * CHAPTER 16 STRUCTURAL DESIGN * * * SECTION 1608 SNOW LOADS * * * 1608.2 Ground snow loads. * * * [Add Section B-1608.2.1 as follows:] B-1608.2.1 Ground snow load for Philadelphia. For the City of Philadelphia, the ground snow load to be used in determining the design snow loads shall be 25 pounds per square foot (1.2 kN/m2). * * * SECTION 1609 WIND LOADS * * * 1609.3 Basic design wind speed. * * * [Add Section B-1609.3.2 as follows:] B-1609.3.2 Basic design wind speed for Philadelphia. For the City of Philadelphia, the basic wind speed for the determination of wind loads shall be based on a 3-second gust and a minimum of 105 miles per hour (47 m/s) 3-second gust for Risk Category I buildings and other structures, 115 miles per hour (51 m/s) 3-second gust for Risk Category II buildings and other structures, and 130 miles per hour (58 m/s) 3-second gust for Risk Category III and IV buildings and other structures. * * * SECTION 1612 FLOOD LOADS * * * 1612.2 Design and construction. * * * [Add Section B-1612.2.1 as follows:] B-1612.2.1 Elevation requirements for Philadelphia. The minimum elevation requirements shall be 1-1/2 feet (457 mm) above the base flood elevation or as specified in ASCE 24, whichever is higher. Exception: Accessory structures need not be elevated or floodproofed to remain dry where they comply with all of the following requirements: 1. The structure shall not be designed or used for human habitation, but shall be limited to the parking of vehicles, or to the storage of tools, material, and equipment related to the principal use or activity; 2. The floor area shall not exceed 200 square feet; 3. The structure will have a low damage potential; 4. The structure will be located on the site so as to cause the least obstruction to the flow of flood waters; 5. Power lines, wiring, and outlets will be elevated to the elevation requirements of Section B-1612.2.1; 6. The structure shall not contain permanently affixed utility equipment and appliances such as furnaces, heaters, washers, dryers, etc.; 7. The structure shall not be used for storage of acetone; ammonia; benzene; calcium carbide; carbon disulfide; celluloid; chlorine; hydrochloric acid; hydrocyanic acid; magnesium; nitric acid and oxides of nitrogen; petroleum products (gasoline, fuel oil, and the like); phosphorus; potassium; sodium; sulfur and sulfur products; pesticides (including insecticides, fungicides, and rodenticides); or radioactive materials; 8. The structure shall not contain sanitary facilities; and 9. The structure shall be adequately anchored to prevent flotation, collapse, and lateral movement and shall be designed to automatically provide for the entry and exit of floodwater for the purpose of equalizing hydrostatic forces on the walls. Designs for meeting this requirement must either be certified by a registered design professional, or meet or exceed the following minimum criteria: a. minimum of two openings having a net total area of not less than one (1) square inch for every square foot of enclosed space; b. the bottom of all openings shall be no higher than one (1) foot above grade c. openings may be equipped with screens, louvers, etc. or other coverings or devices provided that they permit the automatic entry and exit of flood waters. [Delete Section 1612.3 and replace as follows:] B-1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the governing body shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled “The Flood Insurance Study for The City of Philadelphia”, dated December, 1978, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this Section. * * * SECTION 1613 EARTHQUAKE LOADS. * * * 1613.2 Seismic ground motion values. * * * 1613.2.1 Mapped acceleration parameters. * * * [Add Section B-1613.2.1.1 as follows:] B-1613.2.1.1 Mapped acceleration parameters for Philadelphia. For the City of Philadelphia, the short period spectral response acceleration (Ss) shall be 0.20 (20%g) and the 1-second spectral response acceleration (S1) shall be 0.06 (6%g). * * * CHAPTER 17 SPECIAL INSPECTIONS AND TESTS * * * SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION. * * * [Delete Section 1704.6 and replace as follows:] B-1704.6 Structural observations. Where required by the provisions of Section 1704.6.1 or 1704.6.2 the owner or the owner’s authorized agent performing or causing construction or demolition operations shall employ a registered design professional to perform structural observations. A design professional conducting structural observations under Section 1704.6.2 or 1704.6.3 shall also meet the provisions of Section 1704.2.1. Structural observation does not include or waive the responsibility for the inspections in Section 110 or the special inspections in Section 1705 or other sections of this code. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of structural observations. At the conclusion of the work included in the permit, the structural observer shall submit to the building official a written statement that the site visits have been made and identify any reported deficiencies that, to the best of the structural observer’s knowledge, have not been resolved. * * * [Add Sections B-1704.6.2 and B-1704.6.3 as follows:] B-1704.6.2 Structural observations of buildings or structures adjoining or adjacent to excavation, demolition or construction activity. Structural observations shall be provided by an approved agency for the proposed work and with respect to any other adjacent buildings and structures, as applicable, where any of the following conditions exist: 1. Excavation work to a depth of more than 5 feet (1524 mm) below adjacent grade within 10 feet (3048 mm) of an adjacent building or structure. Continuous structural observations shall be provided at all times during excavation work. 2. Excavation, new construction or demolition work occurs within 90 feet (27.43 m) of a building or structure designated as historic under Chapter 14-1000 of The Philadelphia Code on the subject property or abutting lot. Periodic structural observations shall be provided in accordance with an approved monitoring plan per Section B-3307.10. 3. Modification to a wall which is used for joint service between two buildings on separate lots, including demolition. Modifications shall include, but are not limited to, exposure of the wall; removal of perpendicular walls, floor diaphragms, or roof diaphragms; or addition of loading to the wall. Periodic structural observation shall be provided in accordance with an approved monitoring plan per Section B-3310 and shall be in addition to special inspections required by other sections of this code. Exceptions: 1. Structural observation shall not be required for demolition performed under contract with the Department and in compliance with current Procurement Department specifications. B-1704.6.3 Structural observations of historic buildings or structures. Structural observations shall be provided by an approved agency for an alteration to the structural system of, or a vertical addition to, an existing building or structure designated as historic under Chapter 14-1000 of The Philadelphia Code. Periodic structural observations shall be provided in accordance with an approved monitoring plan per Section B-3309. Structural observations shall not be required under this Section B-1704.6.3 for either of the following: 1. One- and two-family dwellings. 2. Where no structural support of the existing portions of the building or structure to remain is required for the proposed work as determined by a registered design professional. * * * SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS * * * B-1705.1 General. * * * B-1705.1.1 Special cases. * * * [Add Sections B-1705.1.1.1 and B-1705.1.1.2 as follows:] B-1705.1.1.1 Identified special cases. Special inspections and tests shall be required for the proposed work identified in Sections B-1705.1.1.1.1 and B-1705.1.1.1.2. B-1705.1.1.1.1 Underpinning. Underpinning of structures shall be subject to special inspections in accordance with the applicable provisions of Section 1705. In addition to the special inspection for structural stability, any new foundation elements installed as part of underpinning operations shall be subject to special inspection as a permanent installation in accordance with the applicable provisions of Chapter 17, including, but not limited to, special inspection for concrete, welding, and pile driving. B-1705.1.1.1.1.1 Inspection program. Prior to commencement of work, the special inspector shall review the contractor’s proposed sequence of operations and determine the areas of work that require design. Inspections of this work shall be continuous during the operations, and shall be conducted by a geotechnical, civil, or structural professional engineer licensed by the Commonwealth of Pennsylvania. B-1705.1.1.1.2 Demolition. The following demolition operations shall be subject to special inspections in accordance with the applicable provisions of Chapter 17: 1. Complete demolition of a building in excess of three (3) stories or any structure in excess of 40 feet (12 192 mm) in height. These inspections shall be performed on a continuous basis until the structure is demolished to a height of 25 feet (7620 mm). 2. Where the use of mechanical demolition is recommended in writing by a licensed structural engineer, pursuant to Section B-3303.9. These inspections shall be performed on a continuous basis until the structure is demolished to a height of 15 feet (4572 mm). 3. Where mechanical demolition equipment, other than handheld devices, is to be used in the full or partial demolition of a building from within the building and with the mechanical equipment being supported by the building, or is to be used within the building to remove debris or move material. These inspections shall be performed on a continuous basis until the structure is demolished to a height of 15 feet (4572 mm). Exception: Demolition performed under contract with the Department and in compliance with current Procurement Department Specifications. B-1705.1.1.1.2.1 Inspection program. Prior to commencement of work, the special inspector shall review the permit documents, including the site safety demolition plan (also known as an engineering study), and become familiar with the reported demolition methods and details of any potential structural hazards to the project and adjoining properties. B-1705.1.1.2 Records of special inspections for special cases. In addition to other reporting requirements established by this Chapter, a special inspection logbook shall be maintained at the special inspector’s office and shall contain the following information: 1. Project identification, permit number and address. 2. Date and time of each inspection. 3. Names of personnel who performed each inspection. 4. Dates of off-site meetings, names of the participants and a summary of the conversations. 5. Any significant observations or instructions given related to any of the following: (a) Deviations from the design documents; (b) Anticipated field conditions; (c) Proper execution of the work; (d) Safe jobsite conditions; and (e) Precautions taken to maintain safe conditions, if work is stopped for any reason. * * * [Add Section B-1705.21 as follows:] B-1705.21 Testing for Air Leakage. B-1705.21.1 Building Envelope Air Leakage Testing. Building envelope air leakage testing shall be performed in accordance with Sections C402.5 and R402.4 of the Energy Conservation Code, as applicable. Testing shall be conducted after all penetrations of the building envelope have been sealed. Testing shall verify compliance with the maximum allowable air-leakage rate and shall be conducted in accordance with ASTM E779, ASTM E1827, or ANSI/RESNET/ICC 380. ASTM E3158, or an equivalent method approved by the code official, may also be used for buildings subject to the commercial provisions of the Energy Conservation Code. A written report of the test results, including the measured air-leakage rate and testing conditions, shall be submitted to the building official prior to final inspection. B-1705.21.2 Duct Leakage Testing. Duct leakage testing shall be performed in accordance with Section R403.3 of the Energy Conservation Code, as applicable to residential or multifamily portions of the building, to verify compliance with the maximum allowable leakage rates. Testing shall be performed at either rough-in or post-construction in accordance with ANSI/RESNET/ICC 380 or ASTM E1554. A written report of the duct leakage test results shall be submitted to the building official prior to final inspection. * * * SECTION 1707 ALTERNATIVE TEST PROCEDURE [Delete Section 1707.1 and replace as follows:] B-1707.1 General. In the absence of approved rules or other approved standards, the building official shall make, or cause to be made, the necessary tests and investigations; or the building official shall accept duly authenticated reports from approved agencies in respect to the quality and manner of use of new materials or assemblies as provided for in Section A-203 of the Administrative Code. The cost of all tests and other investigations required under the provisions of this code shall be borne by the permit applicant. * * * CHAPTER 18 SOILS AND FOUNDATIONS * * * SECTION 1809 SHALLOW FOUNDATIONS * * * 1809.5 Frost protection. * * * [Add Section B-1809.5.1 as follows:] B-1809.5.1 Frost line. The frost line for the City of Philadelphia is 30 inches (762 mm). * * * CHAPTER 27 ELECTRICAL * * * SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS [F] 2702.1 General. * * * [Add Sections B-2702.1.9 and B-2702.1.10 as follows:] B-2702.1.9 Unit battery systems. Unit storage battery systems shall be installed in accordance with this Chapter and these regulations. Where such systems utilize spotlight type of distribution, the projected light shall be directed toward means of egress doorways. Units shall be located to distribute light over the entire floor area, reducing glare and sharp shadows to a minimum. 1. Battery charger: Units shall contain a charger capable of charging the battery at a high rate and also at a trickle rate. The high rate charge shall be capable of replacing the maximum charge taken out in a 90-minute discharge period within 12 hours. The unit shall be designed to provide for automatic high rate charging and restoration to trickle rate or shall be provided with a manually operated two-position switch to control the charging rate. After power failure or when the battery becomes discharged so that the unit cannot provide 90-minute illumination at the required intensity, the battery shall be charged at a high rate until it becomes fully charged at which time the charging rate shall be reduced to the trickle rate. No device that could render the charger ineffective shall be permitted. 2. Test switch: Units shall be equipped with a test switch mounted outside of the cabinet and connected to simulate a power failure to the unit. 3. Signals: Units shall be equipped with a visual signal to indicate when the battery is being charged at the high rate. 4. Wiring and mounting: Units and lamps connected remote from the units shall be permanently mounted and connected in an approved manner. Units shall be mounted so that they can be readily tested, inspected, and serviced and shall be maintained in satisfactory working condition. No switch shall be used to cut off the remote lamps. 5. Testing: Unit storage battery systems shall be tested at least monthly and a record of such tests shall be maintained and made available for inspection by the code official. B-2702.1.10 Gas generators. Generators employing natural gas as a fuel shall have the supply equipped with a separate shutoff valve. The valve shall be tagged “Emergency Power Supply - Not to be Shut Off During an Emergency”. * * * CHAPTER 29 PLUMBING SYSTEMS [Delete the contents of this Chapter and replace with the following:] SECTION B-2901 PLUMBING CODE Plumbing systems in buildings and structures regulated by this code shall be designed and constructed in accordance with the Philadelphia Plumbing Code (Subcode P). * * * CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS [Delete the contents of this chapter and replace with the following:] SECTION B-3001 GENERAL B-3001.1 Scope. Except as otherwise provided for in this code, the design, construction, installation, alteration, addition, repair, movement, equipment, removal, maintenance, use and change in use of elevators, lifting devices and conveying systems and their components shall conform to Chapter 405 of the UCC regulations and ASCE 24 for construction in flood hazard areas established in Section B-1612.3. B-3001.2 Adoptions. The following sections and subsections of Chapter 30 are hereby adopted and incorporated herein: 3002.1 Hoistway enclosure protection. 3002.2 Number of elevator cars in a hoistway. 3002.4 Elevator car to accommodate ambulance stretcher. 3002.7 Common enclosure with stairway. 3004.2.1 Enclosure. 3004.3.1 Enclosure. 3005.4 Machine rooms, control rooms, machinery spaces, and control spaces. SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION SECTION 3007 FIRE SERVICE ACCESS ELEVATOR SECTION 3008 OCCUPANT EVACUATION ELEVATORS CHAPTER 31 SPECIAL CONSTRUCTION * * * SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS * * * [Delete Section 3104.6 and replace as follows:] B-3104.6 Over public way. Pedestrian walkways that extend over or encroach beneath a public way shall be subject to the approval of the Philadelphia Department of Streets in addition to the provisions of this Section. * * * SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES * * * [Add Section B-3109.2 as follows:] B-3109.2 Residential swimming pools. Above ground residential swimming pools that are 12 feet or greater in maximum dimension and their appurtenances shall be located in the rear yard and shall be placed a minimum distance of 2 feet from property lines and buildings on the same lot to provide for maintenance of the pool and adjoining property. In-ground swimming pools shall be located in the rear yard and shall be a minimum distance from property lines equal to the depth of the pool adjoining such property lines. * * * CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY [Delete the contents of this Chapter and insert the following:] SECTION B-3201 GENERAL Encroachments into the public right-of-way are regulated by Title 11 of The Philadelphia Code. CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION SECTION 3301 GENERAL * * * [Delete Section 3301.3 and replace as follows:] B-3301.3 Duration. Temporary construction, scaffolding, and encroachments shall be removed from a construction site after the final inspection is made by the code official or within 30 days after the fulfillment of the requirements of the permit. * * * SECTION 3302 CONSTRUCTION SAFEGUARDS * * * [Delete Section 3302.3 and replace as follows:] B-3302.3 Fire safety during construction. Fire safety during construction shall comply with the applicable requirements of this code and the applicable provisions of the Philadelphia Fire Code. [Add Section B-3302.4 as follows:] B-3302.4 Hot work operations. Cutting, welding or brazing operations shall be in accordance with the requirements of the Philadelphia Fire Code. [Add Section B-3302.5 as follows:] B-3302.5 Abandoned and discontinued operations. B-3302.5.1 Barrier. If any construction or demolition operation is abandoned, discontinued or interrupted, a barrier meeting the requirements of Section 3306 shall be provided to protect the public from potential hazards on the site. B-3302.5.2 Filling and grading. When permits have expired and when no permits have been issued within 3 months of the cessation of excavation operations, the lot shall be filled and graded to eliminate all steep slopes, holes, obstructions or similar sources of hazard. Fill shall be free of organic material and construction debris. The final surface shall be graded in such a manner as to drain the lot, eliminate pockets in the fill, and prevent the accumulation of water without damaging any foundations on the premises or on adjoining property. SECTION 3303 DEMOLITION * * * 3303.4 Vacant lot. * * * [Add Section B-3303.4.1 as follows:] B-3303.4.1 Site grading after demolition. Where a structure is demolished or removed and no new construction is contemplated, the vacant lot shall be graded in accordance with the Building Code. The following demolition material shall not be used as backfill: combustible and fibrous material including metal, reinforcing steel, wood, plastic, plaster, ceramic, roofing materials, trash, household garbage or ash, and any other such debris. The fill shall be covered with a uniform layer of clean, inert, granular material 4 inches or more in depth. Existing concrete paving may remain as a covering. The owner and/or the general contractor for the demolition shall be responsible for compliance with this regulation. * * * [Delete Section 3303.7 and replace as follows:] B-3303.7 Fire safety during demolition. Fire safety during demolition shall comply with the applicable requirements of this code and the applicable provisions of the Philadelphia Fire Code. [Add Sections B-3303.8 through B-3303.14 as follows:] B-3303.8 Protection of adjoining property during demolition. Demolition operations shall not commence until the applicable adjoining property protection is in place as required by Sections B-3303 and B-3307. B-3303.8.1 Safety zone. A safety zone shall be maintained around all demolition areas to prevent non- authorized persons from entering such zone. Where mechanical demolition equipment, other than handheld devices, is to be used for the demolition of a building, the safety zone shall be equal to or greater than half the height of the building to be demolished. Such safety zone may be reduced at a rate in ratio to the extent of demolition, as demolition occurs. For example, at the time fifty percent (50%) of the demolition is complete, the safety zone may be reduced by fifty percent (50%). B-3303.9 Mechanical demolition equipment. Mechanical demolition equipment shall not be used where a building or portion thereof occupied by one or more persons is located within the safety zone or where the structure undergoing demolition is physically connected to a structure not being demolished. Exception: When the use of mechanical demolition is recommended and endorsed in writing by a professional structural engineer licensed in the Commonwealth of Pennsylvania and Special Inspections are performed pursuant to Section B-1705.1.1.1.2. B-3303.9.1 Mechanical demolition and excessive wind. Mechanical demolition equipment shall not be used when average wind speed is at or in excess of 20 miles per hour as reported by the National Weather Service. Exception: When use of such equipment is authorized by the Department for the protection of health and safety or upon a determination that site conditions and precautions established to protect safety reduce the risk of potential harm to a low level. B-3303.10 Demolition sequence. Any structural member that is being dismembered shall not support any load other than its own weight. No wall, chimney, or other structural part shall be left at any time in such condition that it may collapse or be toppled by wind, vibration or any other cause. The method of removal of any structural member shall not destabilize remaining members. All handling and movement of material or debris shall be controlled such that it will not develop unaccounted impact loads on the structure. B-3303.10.1 Structural steel, reinforced concrete, and heavy timber buildings. Structural steel, reinforced concrete, and heavy timber buildings, or portions thereof, shall be demolished column length-by-column length and tier-by-tier. Structural members shall be chained or lashed in place to prevent any uncontrolled swing or drop. In buildings of “skeleton-steel” construction, the steel framing may be left in place during the demolition of masonry. Where this is done, all steel beams, girders, and similar structural supports shall be cleared of all loose material as the masonry demolition progresses downward. Exception: Where the design applicant has demonstrated the adequacy of alternate means of demolition through plans, calculations, or the establishment of safety zones, as appropriate, the Department may accept such alternative means of demolition. B-3303.10.2 Masonry buildings with wooden floors. Demolition of masonry buildings with wooden floors shall comply with the following requirements: 1. Demolition of walls and partitions shall proceed in a systematic manner, and all work above each tier of floor beams shall be completed before any of the supporting structural members are disturbed. 2. Masonry walls, or other sections of masonry, shall not be loosened or permitted to fall upon the floors of the building in such masses as to exceed the safe carrying capacities of the floors or the stability of structural supports. 3. No wall section which is more than one story or 12 feet (3658 mm) in height shall be permitted to stand alone without lateral bracing designed by a registered design professional, unless such wall was originally designed and constructed to stand without such lateral support, and is in a condition safe enough to be self- supporting. All walls shall be left in a stable condition at the end of each shift. 4. Structural or load-supporting members on any floor shall not be cut or removed until all stories above such a floor have been demolished and removed. This provision shall not prohibit the cutting of floor beams for the disposal of materials or for the installation of equipment necessary to safely complete the demolition, so long as the cutting does not negatively impact the safety of the floor system being cut. B-3303.11 Management of hazards. Prior to the commencement of, and during, demolition operations, hazards shall be removed, in accordance with Sections B-3303.11.1 through B-3303.11.5. B-3303.11.1 Dust. Dust-producing operations shall be wetted down to the extent necessary to control the dust. B-3303.11.2 Dust control fencing. A dust control fabric shall be securely attached to all temporary perimeter protection fencing. The material shall be a minimum of five feet in height with a minimum blockage of fifty percent (50%). Information placed on the fabric shall be limited to identification of the responsible Demolition Contractor and any information required by law. B-3303.11.3 Materials chutes. For the purpose of this subsection, a materials chute is a slide, closed in on all sides, through which material is moved from a high place to a lower one. No material shall be dropped more than twenty feet to any point lying outside of the exterior walls of a building or outside of a structure, except through the use of a materials chute. All materials chutes, or sections thereof, shall be entirely enclosed, except for openings equipped with closures at or about floor level for the insertion of materials. At all stories below the top floor, such openings shall be kept closed when not in use. Chutes shall be designed and constructed of such strength as to eliminate failure due to impact of materials or debris loaded therein. B-3303.11.4 Fuel. Prior to the commencement of demolition operations, all pipes, tanks, boilers, or similar devices containing fuel and located in the area authorized to be demolished by the permit shall be purged of such fuel. Exception: Pipes, tanks, boilers, or similar devices containing fuel located in the area authorized to be demolished by the permit and which will not be disturbed during the course of the demolition operation may, in lieu of being purged, be safeguarded so as to prevent damage to such devices during the course of demolition operations. B-3303.11.5 Demolition debris. Materials from demolition shall not be stored overnight on a sidewalk, street or surrounding lot, as may otherwise be permitted, unless placed in a construction dumpster licensed pursuant to Section 11-610 of The Philadelphia Code, or in a dump truck, debris transfer trailer or other motor vehicle licensed under the Pennsylvania Motor Vehicle Code. Loose material shall be removed upon completion of demolition activity at the end of each day, and the area of temporary storage swept clean. Exception: Where the Streets Department has authorized the closure of such sidewalk or street and the sidewalk, street or surrounding lot is enclosed as part of the safety zone established by the demolition contractor pursuant to Section B-3303.8.1. B-3303.12 Removal of foundations and slabs. Where a building, or any portion, has been demolished to grade, the floor slab or foundation of such building, or portion, shall be removed and the site backfilled to grade. Exceptions: 1. Cellar floors may remain provided the cellar floor slab is broken up to the extent necessary to provide ground drainage that prevents accumulation of water, and also provided that all fixtures or equipment that would cause voids in the fill are removed. 2. Where a floor slab or foundation is to remain and not be backfilled, a waiver approved by the Department shall be obtained. Such request for waiver shall be accompanied by a statement and drawings prepared by a registered design professional demonstrating the necessity for retaining the existing floor slab or foundation for future construction or site remediation, as well as demonstrating positive drainage to an approved place of disposal. B-3303.13 Retaining walls. Walls, which serve as retaining walls to support earth or adjoining structures, shall not be demolished until such earth has been properly braced or adjoining structures have been properly underpinned. Walls, which are to serve as retaining walls for backfill, shall not be so used unless capable of safely supporting the imposed load. B-3303.14 Special inspection. Special inspection of demolition activities shall be required in accordance with Sections B-3303.14.1 and B-3303.14.2. Exception: Demolition performed under contract with the Department and in compliance with current Procurement Department Specifications. B-3303.14.1 Mechanical demolition. Where mechanical demolition equipment, other than handheld devices, is to be used in the full or partial demolition of a building from within the building, or is to be used within the building to remove debris or move material, such demolition operation shall be subject to special inspection in accordance with the provisions of Chapter 17 of the Building Code. B-3303.14.2 Demolition of tall structures. Demolition of a building in excess of three (3) stories or any structure in excess of 40 feet (12 192 mm) in height shall be subject to special inspection in accordance with the provisions of Chapter 17 of the Building Code. * * * SECTION 3306 PROTECTION OF PEDESTRIANS * * * 3306.2 Walkways. [Add Sections B-3306.2.1 and B-3306.2.2 as follows:] B-3306.2.1 Sidewalk Closures. Where the Streets Department authorizes the sidewalk to be fenced or closed, the fence shall be a minimum of 6 feet in height. The fence shall be installed to the extent necessary to effectively close off the site. B-3306.2.2 Demolition. Where sidewalks and streets are located within the safety zone as defined in Section B-3303.8, the sidewalk and parking and/or traffic lane(s) within the safety zone shall be closed during demolition activities unless, upon approval by a professional engineer, the Department determines that public safety is adequately protected with such sidewalk or lane left open. A permit shall be obtained from the Streets Department prior to such closures. * * * [Delete Section 3306.7 and replace as follows:] B-3306.7 Covered walkways. Covered walkways shall have a minimum clear height of 8 feet (2438 mm) as measured from the floor surface to the canopy overhead. Adequate lighting shall be provided at all times. Covered walkways shall be designed to support all imposed loads. In no case shall the design live load be less than 300 psf (14.4 kN/m2) for the entire structure. Exceptions: 1. Covered walkways shall be permitted to support a design live load not less than 150 psf (7.2 kN/m2) when serving a building or structure less than one hundred feet in height, provided there is no construction materials or equipment storage thereon. 2. Roofs and supporting structures of covered walkways for new, light-frame construction not exceeding two stories in height are permitted to be designed for a live load of 75 psf (3.6 kN/m2) or the loads imposed on them, whichever is greater. In lieu of such designs, the roof and supporting structure of a covered walkway are permitted to be constructed as follows: a. Footings shall be continuous 2-inch by 6-inch (51 mm by 152 mm) members. b. Posts not less than 4 inches by 6 inches (102 mm by 152 mm) shall be provided on both sides of the roof and spaced not more than 12 feet (3658 mm) on center. c. Stringers not less than 4 inches by 12 inches (102 mm by 305 mm) shall be placed on edge upon the posts. d. Joists resting on the stringers shall be not less than 2 inches by 8 inches (51 mm by 203 mm) and shall be spaced not more than 2 feet (610 mm) on center. e. The deck shall be planks not less than 2 inches (51 mm) thick or wood structural panels with an exterior exposure durability classification not less than 23/32 inch (18.3 mm) thick nailed to the joists. f. Each post shall be knee braced to joists and stringers by members not less than 2 inches by 4 inches (51 mm by 102 mm); 4 feet (1219 mm) in length. g. A curb that is not less than 2 inches by 4 inches (51 mm by 102 mm) shall be set on edge along the outside edge of the deck. * * * SECTION 3307 PROTECTION OF ADJOINING PROPERTY * * * [Add Sections B-3307.3 through B-3307.12 as follows:] B-3307.3 License to enter adjoining property. The responsibility of affording any license to enter adjoining property shall rest upon the owner of the adjoining property involved. It is the responsibility of the person making or causing construction or demolition operations to obtain any necessary license to enter adjoining property from the owner of such property prior to the start of work impacting or potentially impacting the adjoining property. If the person who causes the construction, demolition, or excavation work is denied a license to enter by the adjoining property owner, and the building undergoing work is an imminent danger to the adjoining property, as determined by the Department, such duty to preserve and protect the adjacent property shall devolve to the owner of the adjoining property. B-3307.4 Physical examination. A physical examination of such adjoining property shall be conducted by the person causing the construction or demolition operations prior to the commencement of the operations and at reasonable periods during the progress of the work. Observed conditions shall be recorded by the person causing the construction or demolition operations, and such records shall be made available to the Department upon request. B-3307.5 Soil or foundation work affecting adjoining property. Whenever soil or foundation work occurs, regardless of the depth of such, the person who performs or causes such work shall, at all times during the course of such work and at his or her own expense, preserve and protect from damage any adjoining or adjacent structures, including but not limited to footings and foundations. B-3307.5.1 Additional safeguards during excavation. The person causing the excavation shall support the vertical and lateral load of the adjoining or adjacent structure by proper foundations, underpinning, or other equivalent means where the level of the foundation of the adjoining or adjacent structure is at or above the level of the bottom of the new excavation. B-3307.6 Underpinning. Whenever underpinning is required to preserve and protect an adjacent property from construction, demolition, or excavation work, the person who causes such work shall, at his or her own expense, underpin the adjacent building. B-3307.7 Construction loads supported by existing party walls. The structural adequacy of existing party walls shall be examined by a registered design professional where any construction or demolition work requires the placement of construction materials or equipment upon an existing building or structure supported by the party wall. Any such party wall found through examination to be in an unsafe or imminently dangerous condition as defined by the Philadelphia Property Maintenance Code shall be immediately reported to the Department. Any party wall found through examination to be structurally inadequate to support proposed construction loads shall be strengthened in an approved manner prior to the placement of any construction loads. B-3307.7.1 Support of party walls. Where a party wall will be affected by excavation, regardless of the depth, the person who causes the excavation to be made shall preserve such party wall at his or her own expense so that it shall be, and shall remain, in a safe condition. Where an adjoining party wall is intended to be used by the person causing an excavation to be made, and such party wall is in good condition and sufficient for the uses of the existing and proposed buildings, it shall be the duty of the person excavating to protect the party wall and support it by proper foundations, so that it remains insofar as possible as safe as it was before the excavation was commenced. B-3307.8 Interior walls exposed after demolition. Interior walls that become exterior walls as the result of a demolition shall comply with Chapter 14 of the Building Code. All cornices, where cut shall be sealed. All loose material shall be removed, and all voids shall be filled with a suitable material. Such walls shall have wall coverings installed that comply with the applicable provisions of Chapter 14 of the Building Code. The walls shall be carefully examined by a competent person designated by the permit holder to ascertain the condition and adequacy of the party wall to accept the required wall covering. Wall covering to be installed on a wall shall not be more than the wall is capable of safely supporting. Where the Department determines that a wall is incapable of supporting any acceptable wall covering and has issued a related violation, such wall shall not be required to be covered until the violation is corrected. The exposed portions of the wall may be temporarily protected from weather damage by tarpaulins, waterproof paper, or other temporary means approved for use by the code official for a maximum period of 60 days. Such temporary protection shall be maintained in a weatherproof condition. The exterior of foundation walls that enclose interior space of a structure adjoining a structure that has been demolished shall be damp-proofed in accordance with Chapter 18 of the Building Code prior to backfilling. The person responsible for the demolition shall be responsible for compliance with this regulation. B-3307.9 Preconstruction survey. A preconstruction survey documenting the condition of all adjoining or adjacent buildings or structures shall be prepared and submitted to the building official where the construction or demolition involves any of the following: 1. Excavation work to a depth of more than 5 feet (1524 mm) within 10 feet (3048 mm) of an adjoining or adjacent building. 2. Excavation, new construction or demolition work occurring within 90 feet (27.43 m) of a building or structure designated as historic under Chapter 14-1000 of The Philadelphia Code on the subject property or abutting lot. 3. Modification to a wall which is used for joint service between two buildings on separate lots, including demolition. Modifications shall include, but are not limited to, exposure of the wall, removal of perpendicular walls, floor diaphragms, or roof diaphragms; or addition of loading to the wall. 4. Severing of any structural, roof, or wall covering element extending continuously across the property line onto adjoining property. B-3307.9.1 Preconstruction surveys of buildings or structures shall include the following information: 1. Documentation of adjoining or adjacent buildings that may be impacted by construction or demolition operations, including but, including height, number of stories, construction type, and identification of any element not limited to identification of any visible structural, roof, or wall covering elements extending continuously across the property line. If the work included in the application for permit includes demolition or construction above the roof line of any building or structure on adjoining property, include identification of locations of any visible bulkheads, chimneys, mechanical equipment, parapets, skylights, or vertical extensions of fire walls on the roof of any adjoining or adjacent building. 2. Documentation of the existing conditions of all adjacent or adjoining buildings, which shall include the location extent and dimension of any visible cracks or pronounced deformations or misalignment of the building or structure’s entire exterior envelope. 3. Photographs of the adjoining or adjacent buildings or structures showing, at a minimum: (1) the elevation as visible from any public right-of-way and (2) photographs of any locations or elements identified in B-3307.9.1 or B-3307.9.2. 4. Statement, signed by a representative of the entity performing structural observations in accordance with Chapter 17, confirming that existing conditions identified in this preconstruction survey will be monitored throughout the construction or demolition operation. B-3307.10 Protection of roofs. Whenever any building is to be constructed or demolished above the roof of an adjoining building, it shall be the duty of the person causing such work to protect from damage at all times during the course of such work and at his or her own expense the roof, skylights, other roof outlets, and equipment located on the roof of the adjoining building, and to use every reasonable means to avoid interference with the use of the adjoining building during the course of such work. Adjoining roof protection shall be secured to prevent dislodgement by wind. Where construction or demolition work occurs at a height of at least 48 inches (1219 mm) above the level of the adjoining roof, adjoining roof protection shall consist of 2 inches (51 mm) of flame-retardant foam under 2 inches (51 mm) of flame-retardant wood plank laid tight and covered by flame-retardant plywood, or shall consist of equivalent protection acceptable to the Department, and shall extend to a distance of at least 12 feet (3658 mm) from the edge of the building being constructed or demolished. B-3307.11 Notification. The owner or owner’s agent performing or causing construction or demolition operations shall provide written notification of the following activity to the adjoining property owner: 1. Excavation exceeding a depth of five (5) feet below adjacent grade, excluding digging, trenching, or boring for utilities or geotechnical exploration, that is within ten (10) feet of an adjacent structure. 2. Modification to a fire wall which is used for joint service between two buildings on separate lots, including demolition or underpinning. 3. Excavation, new construction or demolition work occurring within 90 feet of a designated historic building or structure on an abutting lot. 4. Severing of any structural, roof, or wall covering element extending continuously across the property line onto adjoining property. 5. Demolition activity that results in the exposure of a wall of an adjacent or adjoining building. Such notification shall describe the nature of work, estimated schedule and duration, and shall include the pre-construction survey, plans or details depicting work that may affect the adjoining or adjacent property, details of monitoring to be performed on the adjoining property, protection proposed to be installed on the adjoining property, a copy of the contractor’s Certificate of Insurance for general liability, and contact information for the project. Notification shall be delivered to the adjacent property owner at the address registered with the City of Philadelphia Office of Property Assessment and the resident of the adjoining property, if different from owner. B-3307.11.1 Initial notification shall be delivered prior to submission of the permit application. 1. The permit application shall include the adjacent property owner’s signature affirming receipt of notification and statement of owner’s rights on a form established by the Department. 2. If the party carrying out the construction or demolition is unable to obtain the adjacent property owner’s signature of receipt, evidence of delivery and reasonable attempt to acquire signature must be provided. In the absence of the adjacent property owner’s signature of receipt, no construction or demolition permit shall be issued less than 60 days after either permit application submission or the date that notice was transmitted, whichever comes later. B-3307.11.2 Final notification shall be delivered at least 10 calendar days prior to commencement of work updating the construction schedule and providing any changes to the detail required for the Initial Notification under Section B-3307.11. The party carrying out the construction or demolition shall be responsible to notify the adjacent property owner and resident of any significant modifications required during construction or demolition operations that may have an impact on adjacent property. Exceptions: 1. Notification shall not be required for demolition performed under contract with the Department and in compliance with current Procurement Department specifications. 2. The time periods prescribed under B-3307.11.1 and B-3307.11.2 shall be waived for work performed under private contract that is necessary to abate an unsafe or imminently dangerous condition, as determined by the Department. B-3307.11.3 The Department may provide notice to the owner or resident of the adjoining property of permit application submission, the property owner’s rights, and contact information for the permit applicant. B-3307.12 Monitoring. Construction or demolition operations shall be monitored by a licensed special inspector in accordance with Chapter 17. Operations shall be monitored in accordance with an approved monitoring plan specifying scope, frequency, and acceptable tolerances. * * * SUBCODE "E" (THE PHILADELPHIA ELECTRICAL CODE) Editor's note: Electrical standards are provided for in Chapter 27 of the 2018 International Building Code as adopted in Title 4, Subcode B, which incorporates NFPA 70 (2017). NFPA 70 (National Electrical Code) can be accessed at: http://www.nfpa.org/codes-and-standards/document-information-pages?mode=code&code=70&tab=editions [History: Added, Bill No. 030781 (approved December 31, 2003). This subcode "E" repealed and replaced in its entirety previous subcode "E", added by Bill No. 960590-A (approved March 26, 1997), which had replaced previous Title 4.1, which was based on 1964 Ordinances, p. 1262, as amended. Sections 3 and 4 of Bill No. 030781 provide: "Section 3. The provisions of Title 4 of The Philadelphia Code added by Section 2 of this Ordinance, so far as they are the same as existing provisions of The Philadelphia Code, shall be construed as a continuation of such provisions and not as new enactments. Section 4. This Ordinance shall take effect as follows: (a) From the time of adoption of this Ordinance until January 1, 2004, an applicant for a permit under one or more of the subcodes of Title 4 of The Philadelphia Code shall have the option of proceeding under the provisions of Title 4 as amended by this Ordinance, or under the provisions of Title 4 as they existed immediately prior to adoption of this Ordinance. (b) Effective January 1, 2004, the provisions of this Ordinance shall apply. (c) Notwithstanding any provision of this Ordinance to the contrary, at the option of the permit applicant, this Ordinance shall not apply to: (1) new buildings or renovations to existing buildings for which an application for a building permit has been made to the City prior to the effective date of this Ordinance; or (2) new buildings or renovations to existing buildings on which a contract for design or construction has been signed prior to the effective date of this Ordinance." Amended, Bill No. 090841-A (approved February 17, 2010). Section E-103, Chapter 2, Section E-201, Chapter 3, Section E-301 and Section E-302 deleted, Bill No. 110833 (approved December 21, 2011).] CHAPTER 1 SCOPE SECTION E-101 RESERVED [History: Deleted, Bill No. 090841-A (approved February 17, 2010).] SECTION E-102 RESERVED [History: Deleted, Bill No. 110834 (approved December 21, 2011).] SUBCODE "EB" (THE PHILADELPHIA EXISTING BUILDING CODE) Article EB-1.0 Adoption of the “2021 International Existing Building Code”, pursuant to the Pennsylvania Uniform Construction Code Act (“Act”), with state amendments and local amendments that were in effect prior to enactment of the Act or approved pursuant to Section 503 of the Act. § EB-1.1 The “2021 International Existing Building Code”, as published by the International Code Council, is hereby adopted as the Existing Building Code of the City of Philadelphia and is incorporated as if fully set forth herein, subject to the amendments provided in this Subcode EB. Editor's note: The 2021 International Existing Building Code can be found at: https://codes.iccsafe.org/content/IEBC2021P1 § EB-1.1.1 The numbers of all local amendments shall be preceded with the prefix “EB-”. § EB-1.1.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. [History: Added, Bill No. 030778 (approved December 31, 2003); repealed and replaced, Bill No. 180176 (approved June 6, 2018). Section 7 of Bill No. 180176 provides: "The provisions of this Ordinance shall be effective October 1, 2018, and upon taking effect replace and supersede previously adopted Regulations of the Department of Licenses and Inspections related to Subcode B and Subcode M." Repealed and replaced, Bill No. 260392 (approved June 12, 2026).] CHAPTER 1 SCOPE AND ADMINISTRATION [Delete contents of entire Chapter and replace as follows:] SECTION EB-101 GENERAL EB-101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Existing Building Code and will be referred to herein as the “Philadelphia Existing Building Code” or “this code”. EB-101.2 Scope. The provisions of the Philadelphia Existing Building Code shall apply to the repair, alteration, change of occupancy, addition to and relocation of existing buildings. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress, and their accessory structures not more than three stories above grade plane in height, shall comply with this code or the Philadelphia Residential Code (Subcode R). EB-101.3 Intent. The intent of this code is to provide flexibility to permit the use of alternative approaches to achieve compliance with minimum requirements to safeguard the public health, safety and welfare insofar as they are affected by the repair, alteration, change of occupancy, addition and relocation of existing buildings. EB-101.4 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are set forth in the Administrative Code (Subcode A). EB-101.5 Safeguards during construction. The provisions of Chapter 33 of the International Building Code with amendments (Subcode B) shall apply to the construction safeguards required for all building construction and demolition. EB-101.6 Preliminary meeting. When requested by the code official, the code official shall meet with the permit applicant prior to the application for a construction permit to discuss plans for the proposed work or change of occupancy in order to establish the specific applicability of the provisions of this code. EB-101.6.1 Building evaluation. The code official is authorized to require an existing building to be evaluated by a registered design professional based on the circumstances agreed upon at the preliminary meeting. The design professional shall notify the code official if any potential noncompliance with the provisions of this code is identified. EB-101.7 Work on individual components or portions. Where the code official determines that a component or a portion of a building or structure is required by certain provisions of this code to be repaired, strengthened or replaced, only that specific component or portion shall be required to be repaired, strengthened, or replaced unless more is specifically required by other provisions of this code. EB-101.8 Correction of violations of other codes. Repairs or alterations mandated by the property maintenance or fire code or mandated by any licensing ordinance or regulation shall conform to the requirements of that code, regulation or ordinance and shall not be required to conform to this code unless the code requiring such repair or alteration so provides. EB-101.9 Unsafe buildings and equipment. Unsafe buildings and equipment shall be regulated by the Philadelphia Property Maintenance Code (Subcode PM). EB-101.10 Special inspections. Special inspections shall be required in accordance with the International Building Code. EB-101.11 Appendices. No appendices are adopted as a part of this code. * * * CHAPTER 3 PROVISIONS FOR ALL COMPLIANCE METHODS SECTION 301 ADMINISTRATION * * * [Add Section EB-301.5 as follows:] EB-301.5 Fire Code compliance. Alterations, additions and changes of occupancy complying with Section 301.3.1, 301.3.2 or 301.3.3 of this code in buildings complying with the Philadelphia Fire Code shall be considered in compliance with the provisions of this code. * * * [Add Section EB-310 as follows:] SECTION EB-310 STORAGE OF REFUSE EB-310.1 General. Provisions for storage of refuse in existing buildings shall comply with the requirements of this Section. EB-310.2 Change of occupancy. An area for the storage of refuse shall be provided where there is a change of occupancy group of an existing building where the use will generate refuse, as defined in Section 9-604 of The Philadelphia Code, and where such refuse is to be disposed of by use of a dumpster, as defined in Section 10-722 of The Philadelphia Code. The area of storage shall be located either inside the building or on the premises and enclosed on all sides. EB-310.3 Alterations with no change of occupancy. All buildings which contain uses in existence, shall maintain indoor storage of refuse required by Section EB-310.2 as established on December 19, 1989. Uses in existence prior to this date shall, where there is sufficient space available on the premises, keep all dumpsters within enclosures constructed in accordance with regulations promulgated by the Department of Licenses and Inspections. In the event that a dumpster is maintained off the building premises on December 19, 1989, such dumpster shall not be enclosed and is permitted to be so maintained provided that there is no change in use of the building for which the dumpster is employed and for so long as it is placed and maintained in accordance with the provisions of Section 10-722 of The Philadelphia Code. [Add Section EB-311 as follows:] SECTION EB-311 SPECIAL ASSEMBLY OCCUPANCIES EB-311.1 Scope. The alteration, addition or change of occupancy of all existing buildings, including those identified as historic buildings, shall comply with the provisions of Sections EB-311.2 through EB-311.4. EB-311.2 General. Assembly Group A occupancies classified as Special Assembly Occupancies shall comply with the additional provisions of this Section. EB-311.3 Classification as a Special Assembly Occupancy. An Assembly Group A occupancy shall also be classified as a Special Assembly Occupancy if 50 or more people congregate primarily for social entertainment purposes as defined in Section 9-703 of The Philadelphia Code at such location at one or more times during the course of any year. Such facilities shall include but not be limited to any of the following: nightclub; discotheque; cabaret; tavern; bar; restaurant; private club; banquet hall; and similar place of assembly without primarily fixed seating. EB-311.4 Fire alarm. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 of the Philadelphia Building Code shall be installed in all Special Assembly Occupancies. Exception: Manual fire alarm boxes are not required in Special Assembly Occupancies where the occupancy is protected throughout with a rate-of-rise heat detection system, provided one manual fire alarm box is installed in a location that is constantly attended by staff during periods of occupancy by the public. EB-311.4.1 Activation of the fire alarm. In Special Assembly Occupancies, a shut-off (shunt trip) device shall be provided to automatically shut off electricity to circuits controlling audio equipment in the facility upon activation of the fire alarm system or automatic sprinkler system. * * * CHAPTER 5 PRESCRIPTIVE COMPLIANCE * * * SECTION 504 FIRE ESCAPES * * * [Delete Section 504.2 and replace as follows:] EB-504.2 Location. Where located on the front of the building and where projecting beyond the building line, the lowest landing shall not be less than 10 feet (3048 mm) or more than 14 feet (4268 mm) above grade and shall be equipped with a counterbalanced stairway to the street. In alleyways and thoroughfares less than 30 feet (9144 mm) wide, the clearance under the lowest landing shall not be less than 12 feet (3658 mm). * * * CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL * * * [Delete Section 1301.3.1 and replace as follows:] EB-1301.3.1 Hazards. Where the code official determines that an unsafe condition exists as provided for in the Philadelphia Property Maintenance Code (Subcode PM), such unsafe condition shall be abated in accordance with that code. * * * CHAPTER 15 CONSTRUCTION SAFEGUARDS [Delete contents of entire Chapter and replace with the following:] See Section EB-101.5 Safeguards during construction. * * * SUBCODE "EC" (THE PHILADELPHIA ENERGY CONSERVATION CODE) Article EC-1.0 Adoption of the “2021 International Energy Conservation Code”, with local amendments. § EC-1.1 The “2021 International Energy Conservation Code”, as published by the International Code Council, is hereby adopted as the Energy Conservation Code of the City of Philadelphia, with amendments as set forth in § EC-1.2. Editor's note: The 2021 International Energy Conservation Code can be found at: https://codes.iccsafe.org/content/IECC2021P1 § EC-1.2 The “2021 International Energy Conservation Code”, copies of which are on file with the Department of Licenses and Inspections, is incorporated as if fully set forth herein, subject to the following local amendments. § EC-1.2.1 The numbers of all local amendments shall be preceded with the prefix “EC-”. § EC-1.2.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. § EC-1.2.3 Deletions of material are noted in [brackets]. [History: Added, Bill No. 030777 (approved December 31, 2003); repealed and replaced, Bill No. 180176 (approved June 6, 2018). Section 7 of Bill No. 180176 provides: "The provisions of this Ordinance shall be effective October 1, 2018, and upon taking effect replace and supersede previously adopted Regulations of the Department of Licenses and Inspections related to Subcode B and Subcode M." Repealed and replaced, Bill No. 250644 (approved June 12, 2026).] IECC – COMMERCIAL PROVISIONS CHAPTER 1 SCOPE AND ADMINISTRATION [Delete Section C101 and substitute the following:] SECTION EC-C101 SCOPE AND GENERAL REQUIREMENTS EC-C101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Energy Conservation Code (IECC) and will be referred to herein as the “Philadelphia Energy Conservation Code” or “this code”. EC-C101.2 Scope. The IECC Commercial Provisions of this code apply to commercial buildings and their sites, associated systems and equipment. EC-C101.3 Intent. This code shall regulate the design and construction of buildings for the effective use and conservation of energy over the useful life of each building. This code is intended to provide flexibility to permit the use of innovative approaches and techniques to achieve this objective. This code is not intended to abridge safety, health or environmental requirements contained in other applicable codes or ordinances. EC-C101.4 Applicability. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive requirement shall govern. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall govern. EC-C101.4.1 Mixed occupancy. Where a building includes both residential and commercial occupancies, each occupancy shall be separately considered and meet the applicable provisions of IECC - Commercial Provisions or IECC - Residential Provisions. EC-C101.5 Compliance. Commercial buildings shall meet the provisions of the IECC - Commercial provisions. Residential buildings shall meet the provisions of IECC - Residential Provisions. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress, and their accessory structures, shall comply with the Philadelphia Residential Code (Subcode R). EC-C101.5.1 Compliance materials. The code official may approve specific computer software, worksheets, compliance manuals and other similar materials that meet the intent of this code. EC-C101.6 Administrative provisions. This Chapter contains provisions that are unique to the administration of this code. Additional provisions applicable to the administration of this code are set forth in Subcode A (Administrative Code). EC-C101.7 Appendices. No appendices are adopted as a part of this code. [Delete Sections C103.3 through C103.5] [Pursuant to the UCC, delete Section C105.2.6 and replace as follows:] EC-C105.2.6 Final inspection. The building shall have a final inspection and not be occupied until approved. [Delete Sections C107 through C110] * * * CHAPTER 4 COMMERCIAL ENERGY EFFICIENCY * * * C402 BUILDING ENVELOPE REQUIREMENT * * * [Pursuant to the UCC, delete Section C402.5.5 and replace as follows:] EC-C402.5.5 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8, where combustion air is supplied through openings in an exterior wall to a room or space containing a space-conditioning fuel-burning appliance, one of the following shall apply: 1. The room or space containing the appliance shall be located outside of the building thermal envelope. 2. The room or space containing the appliance shall be enclosed and isolated from conditioned spaces inside the building thermal envelope. Such rooms shall comply with all of the following: 2.1. The walls, floors and ceilings that separate the enclosed room or space from conditioned spaces shall be insulated to be not less than equivalent to the insulation requirement of below-grade walls as specified in Table C402.1.3 or 2.2. The walls, floors and ceilings that separate the enclosed room or space from conditioned spaces shall be sealed in accordance with Section C402.5.1.1. 2.3. The doors into the enclosed room or space shall be fully gasketed. 2.4. Water lines and ducts in the enclosed room or space shall be insulated in accordance with Section C403.2.5. Where an air duct supplying combustion air to the enclosed room or space passes through conditioned space, the duct shall be insulated to an R-value of not less than R-8. 2.5. Where an air duct supplying combustion air to the enclosed room or space passes through conditioned space, the duct shall be insulated to an R-value of not less than R-8. Exception: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Sections 901 through 905 of the International Mechanical Code, and Section 2111.14 of the International Building Code. * * * C405 ELECTRICAL POWER AND LIGHTING SYSTEMS * * * [Pursuant to the UCC, delete Section C405.11 and replace as follows:] EC-C405.11 Automatic receptacle control. The following may have automatic receptacle control complying with Section EC-C405.11.1: 1. At least 50 percent of all 125V, 15- and 20-amp receptacles installed in enclosed offices, conference rooms, rooms used primarily for copy or print functions, breakrooms, classrooms and individual workstations, including those installed in modular partitions and module office workstation systems. 2. At least 25 percent of branch circuit feeders installed for modular furniture not shown on the construction documents. EC-C405.11.1 Automatic receptacle control function. Automatic receptacle controls shall comply with the following: 1. Either split controlled receptacles shall be provided with the top receptacle controlled, or a controlled receptacle shall be located within 12 inches (304.8 mm) of each uncontrolled receptacle. 2. One of the following methods shall be used to provide control: 2.1. A scheduled basis using a time-of-day operated control device that turns receptacle power off at specific programmed times and can be programmed separately for each day of the week. The control device shall be configured to provide an independent schedule for each portion of the building of not more than 5,000 square feet (464.5 m 2 ) and not more than one floor. The occupant shall be able to manually override an area for not more than 2 hours. Any individual override switch shall control the receptacles of not more than 5,000 feet (1524 m). 2.2. An occupant sensor control that shall turn off receptacles within 120 minutes of all occupants leaving a space. 2.3. An automated signal from another control or alarm system that shall turn off receptacles within 120 minutes after determining that the area is unoccupied. 3. All controlled receptacles shall be permanently marked in accordance with NFPA 70 and be uniformly distributed throughout the space. 4. Plug-in devices shall not comply. Exceptions: Automatic receptacle controls are not required for the following: 1. Receptacles specifically designated for equipment requiring continuous operation (24 hours per day, 365 days per year). 2. Spaces where an automatic control would endanger the safety or security of the room or building occupants. 3. Within a single modular office workstation, noncontrolled receptacles are permitted to be located more than 12 inches (304.8 mm), but not more than 72 inches (1828 mm) from the controlled receptacles serving that workstation. * * * IECC – RESIDENTIAL PROVISIONS The text of the 2021 IECC-R parallels the text of the 2021 IRC, Part IV - Energy Conservation. The section numbers appearing in parentheses after each section number are the section numbers of the corresponding text in the IRC, Part IV. If a section does not have a section number in parentheses after it, then there is no corresponding text in the 2021 IRC, Part IV. * * * CHAPTER 1 SCOPE AND ADMINISTRATION [Delete Section R101 and substitute the following:] SECTION EC-R101 SCOPE AND GENERAL REQUIREMENTS EC-R101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Energy Conservation Code (IECC) and will be referred to herein as the “Philadelphia Energy Conservation Code” or “this code”. EC-R101.2 Scope. The IECC Residential Provisions of this code apply to residential buildings and their sites, associated systems and equipment. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the Philadelphia Residential Code (Subcode R). EC-R101.3 Intent. This code shall regulate the design and construction of buildings for the effective use and conservation of energy over the useful life of each building. This code is intended to provide flexibility to permit the use of innovative approaches and techniques to achieve this objective. This code is not intended to abridge safety, health or environmental requirements contained in other applicable codes or ordinances. EC-R101.4 Applicability. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive requirement shall govern. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall govern. EC-R101.4.1 Mixed occupancy. Where a building includes both residential and commercial occupancies, each occupancy shall be separately considered and meet the applicable provisions of IECC - Commercial Provisions or IECC - Residential Provisions. EC-R101.5 Compliance. Residential buildings shall meet the provisions of IECC - Residential Provisions. Commercial buildings shall meet the provisions of the IECC - Commercial provisions. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress, and their accessory structures, shall comply with the Philadelphia Residential Code (Subcode R). EC-R101.5.1 Compliance materials. The code official may approve specific computer software, worksheets, compliance manuals and other similar materials that meet the intent of this code. EC-R101.6 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. Additional provisions applicable to the administration of this code are set forth in Subcode A (Administrative Code). EC-R101.7 Appendices. No appendices are adopted as a part of this code. [Delete Sections R103.3 through R103.5] [Delete Section R104] [Delete Sections R106 through R109] * * * CHAPTER 2 DEFINITIONS * * * R202 GENERAL DEFINITIONS * * * [Pursuant to the UCC:] FRAMING FACTOR. The fraction of the total building component area that is structural framing. * * * CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY * * * R402 BUILDING THERMAL ENVELOPE * * * [Pursuant to the UCC, delete Table R402.1.2 and replace as follows:] TABLE EC-R402.1.2 (N1102.1.2) MAXIMUM ASSEMBLY U-FACTORS a AND FENESTRATION REQUIREMENTS CLIMATE ZONE | FENESTRA- TION U-FACTOR b | SKYLIGHT U-FACTOR | GLAZED FENESTRA- TION SHGC d, e | CEILING U-FACTOR | FRAME WALL U-FACTOR | MASS WALL U-FACTOR b | FLOOR U-FACTOR | BASEMENT WALL U-FACTOR | CRAWL SPACE WALL U-FACTOR CLIMATE ZONE | FENESTRA- TION U-FACTOR b | SKYLIGHT U-FACTOR | GLAZED FENESTRA- TION SHGC d, e | CEILING U-FACTOR | FRAME WALL U-FACTOR | MASS WALL U-FACTOR b | FLOOR U-FACTOR | BASEMENT WALL U-FACTOR | CRAWL SPACE WALL U-FACTOR 1 | 0.50 | 0.75 | 0.25 | 0.035 | 0.084 | 0.197 | 0.064 | 0.360 | 0.477 2 | 0.40 | 0.65 | 0.25 | 0.030 | 0.084 | 0.165 | 0.064 | 0.360 | 0.477 3 | 0.32 | 0.55 | 0.25 | 0.030 | 0.060 | 0.098 | 0.047 | 0.091 | 0.136 4 except Marine | 0.32 | 0.55 | 0.40 | 0.026 | 0.060 | 0.098 | 0.047 | 0.059 | 0.065 5 and Marine 4 | 0.30 | 0.55 | NR | 0.026 | 0.051 | 0.082 | 0.033 | 0.050 | 0.055 6 | 0.30 | 0.55 | NR | 0.026 | 0.045 | 0.060 | 0.033 | 0.050 | 0.055 7 and 8 | 0.30 | 0.55 | NR | 0.026 | 0.045 | 0.057 | 0.028 | 0.050 | 0.055 | | | | | | | | | a. Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source. b. Mass walls shall be in accordance with Section R402.2.5. Where more than half the insulation is on the interior, the mass wall U-factors shall not exceed 0.17 in Climate Zone 1, 0.14 in Climate Zone 2, 0.12 in Climate Zone 3, 0.087 in Climate Zone 4 except Marine, 0.065 in Climate Zone 5 and Marine 4, and 0.057 in Climate Zones 6 through 8. c. In warm-humid locations as defined by Figure R301.1 and Table R301.1, the basement wall U-factor shall not exceed 0.360. d. The SHGC column applies to all glazed fenestration. Exception: In Climate Zones 0 through 3, skylights shall be permitted to be excluded from glazed fenestration SHGC requirements provided that the SHGC for such skylights does not exceed 0.30. e. There are no SHGC requirements in the Marine Zone. f. A maximum U-factor of 0.32 shall apply in Marine Climate Zone 4 and Climate Zones 5 through 8 to vertical fenestration products installed in buildings located either: 1. Above 4,000 feet in elevation above sea level, or 2. In windborne debris regions where protection of openings is required by Section R301.2.1.2. of the International Residential Code. * * * [Pursuant to the UCC, delete Table R402.1.3 and replace as follows:] TABLE R402.1.3 (N1102.1.3) INSULATION MINIMUM R-VALUE AND FENESTRATION REQUIREMENTS BY COMPONENT a CLIMATE ZONE | FENESTRA- TION U-FACTOR b | SKYLIGHT b U-FACTOR | GLAZED FENESTRA- TION SHGC b, e | CEILING R-FACTOR | WOOD FRAME WALL R-VALUE | MASS WALL R-VALUE i | FLOOR R-VALUE | BASEMENT c WALL R-VALUE | SLAB d R-VALUE & DEPTH | CRAWL SPACE c WALL R-VALUE CLIMATE ZONE | FENESTRA- TION U-FACTOR b | SKYLIGHT b U-FACTOR | GLAZED FENESTRA- TION SHGC b, e | CEILING R-FACTOR | WOOD FRAME WALL R-VALUE | MASS WALL R-VALUE i | FLOOR R-VALUE | BASEMENT c WALL R-VALUE | SLAB d R-VALUE & DEPTH | CRAWL SPACE c WALL R-VALUE 1 | NR | 0.75 | 0.25 | 30 | 13 | 3/4 | 13 | 0 | 0 | 0 2 | 0.40 | 0.65 | 0.25 | 38 | 13 | 4/6 | 13 | 0 | 0 | 0 3 | 0.32 | 0.55 | 0.25 | 38 | 20 or 13 + 5 h | 8/13 | 19 | 5/13 f | 0 | 5/13 4 except Marine | 0.32 | 0.55 | 0.40 | 49 | 20 or 13 + 5 h | 8/13 | 19 | 10/13 | 10, 2 ft | 10/13 5 and Marine 4 | 0.30 | 0.55 | NR | 49 | 23 or 13 + 7.5 h or 20 + 3.8 h | 13/17 | 30 g | 15/19 | 10, 4 ft or 15, 3 ft | 15/19 6 | 0.30 | 0.55 | NR | 49 | 20 + 5 h or 13 + 10 h | 15/20 | 30 g | 15/19 | 10, 4 ft | 15/19 7 and 8 | 0.30 | 0.55 | NR | 49 | 20 + 5 h or 13 + 10 h | 19/21 | 38 g | 15/19 | 10, 4 ft | 15/19 | | | | | | | | | | For SI: 1 foot = 304.8 mm. NR = Not Required. a. R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or design thickness of the insulation, the installed R-value of the insulation shall be not less than the R-value specified in the table. b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: In Climate Zones 1 through 3, skylights shall be permitted to be excluded from glazed fenestration SHGC requirements provided that the SHGC for such skylights does not exceed 0.30. c. the interior of the basement wall. “15/19” means R-15 continuous insulation on the interior or exterior of the home or R-19 cavity insulation on the interior of the basement wall. Alternatively, compliance with “15/19” shall be R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the home. d. R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation R-value for slabs. as indicated in the table. The slab edge insulation for heated slabs shall not be required to extend below the slab. e. There are no SHGC requirements in the Marine Zone. f. Basement wall insulation shall not be required in warm-humid locations as defined by Figure R301.1 and Table R301.1. g. Alternatively, insulation sufficient to fill the framing cavity providing not less than an R-value of R-19. h. The first value is cavity insulation, the second value is continuous insulation. Therefore, as an example, “13+5” means R-13 cavity insulation plus R-5 continuous insulation. i. Mass walls shall be in accordance with Section R402.2.5. The second R-value applies where more than half of the insulation is on the interior of the mass wall. * * * R403 SYSTEMS * * * [Pursuant to the UCC, delete Section R403.3.7and replace as follows:] EC-R403.3.7 (N1103.3.7) Building cavities (Mandatory). Building framing cavities shall not be used as supply ducts. * * * [Pursuant to the UCC, delete Section R403.5.1.1 and replace as follows:] EC-R403.5.1.1 (N1103.5.1.1) Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosyphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. The controls shall limit the temperature of the water entering the cold water piping to no greater than 104ºF (40ºC). Exception: Where the entire hot water piping system (both supply and return) are insulated with a minimum R3 insulation, the stated controls are not required. EC-R403.5.1.1.1 Demand recirculation water systems. Where installed, demand recirculation water systems shall have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance, sensing the presence of a user of a fixture or sensing the flow of hot or tempered water to a fixture fitting or appliance. EC-R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. * * * R404 ELECTRICAL POWER AND LIGHTING SYSTEMS * * * [Pursuant to the UCC, delete Section R404.1.2 (N1104.1.2)] * * * R405 TOTAL BUILDING PERFORMANCE * * * [Pursuant to the UCC, delete Section R405.3.2 and replace as follows:] EC-R405.3.2 (N1105.3.2) Compliance report. Compliance software tools shall generate a report that documents that the proposed design complies with Section R405.4 (N1105.4). A compliance report on the proposed design shall be submitted with the application for the building permit. Upon completion of the building, a compliance report based on the as-built condition of the building shall be submitted to the code official before a certificate of occupancy is issued. Batch sampling of buildings to determine energy code compliance for all buildings in the batch shall be prohibited. Compliance reports shall include information in accordance with Sections R405.43.2.1 (N1105.43.2.1 ) and R405.43.2.2 (N1105.43.2.2). Where the proposed design of a building could be built on different sites where the cardinal orientation of the building on each site is different, compliance of the proposed design for the purposes of the application for the building permit shall be based on the worst- case orientation, worst-case configuration, worst-case building air leakage and worst-case duct leakage. Such worst-case parameters shall be used as inputs to the compliance software for energy analysis. EC-R405.3.2.1 (N1105.3.2.1) Compliance report for permit application. A compliance report submitted with the application for building permit shall include the following: 1. Building street address, or other building site identification. 2. A statement indicating that the proposed design complies with Section R405.2 (N1105.2). 3. An inspection checklist documenting the building component characteristics of the proposed design as indicated in Table R405.4.2(1) (N1105.4.2(1)). The inspection checklist shall show results for both the standard reference design and the proposed design with user inputs to the compliance software to generate the results. 4. A site-specific energy analysis report that is in compliance with Section R405.2 (N1105.2). 5. The name of the individual performing the analysis and generating the report. 6. The name and version of the compliance software tool. EC-R405.3.2.2 (N1105.3.2.2) Compliance report for certificate of occupancy. A compliance report submitted in order to obtain the certificate of occupancy shall include the following: 1. Building street address, or other building site identification. 2. Declaration of the total building performance path on the title page of the energy report. 3. A statement bearing the name of the individual performing the analysis and generating the report, indicating that the as-built building complies with Section R405.2 (N1105.2). 4. The name and version of the compliance software tool. 5. A site-specific energy analysis report that is in compliance with Section R405.2 (N1105.2). 6. A final confirmed certificate indicating compliance based on inspection, and a statement indicating that the confirmed rated design of the built home complies with Section R405.2 (N1105.2). The certificate shall report the energy features that were confirmed to be in the home, including component-level insulation R-values or U-factors; results from any required duct system and building envelope air leakage testing; and the type and rated efficiencies of the heating, cooling, mechanical ventilation and service water heating equipment installed. 7. Where on-site renewable energy systems have been installed, the certificate shall report the type and production size of the installed system. * * * [Pursuant to the UCC, delete Table R405.4.2 (1) (N1105.4.2(1)) and replace as follows:] TABLE EC- R405.4.2(1) (N1105.4.2(1)) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS BUILDING COMPONENT | STANDARD REFERENCE DESIGN | PROPOSED DESIGN TABLE EC- R405.4.2(1) (N1105.4.2(1)) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS BUILDING COMPONENT | STANDARD REFERENCE DESIGN | PROPOSED DESIGN Above-grade walls | Type: mass where the proposed wall is a mass wall otherwise wood frame. | As proposed Gross area: same as proposed. | As proposed U-factor: as specified in Table R402.1.2. | As proposed Solar absorptance = 0.75 | As proposed Emittance = 0.90 | As proposed Basement and crawl space walls | Type: same as proposed. | As proposed Gross area: same as proposed. | As proposed U-factor: as specified in Table R402.1.2, with the insulation layer on the interior side of walls. | As proposed Above-grade floors | Type: Wood frame. | As proposed Gross area: same as proposed. | As proposed U-factor: as specified in Table R402.1.2. | As proposed Ceilings | Type: wood frame. | As proposed Gross area: same as proposed. | As proposed U-factor: as specified in Table R402.1.2. | As proposed Roofs | Type: compositions shingle on wood sheathing. | As proposed Gross area: same as proposed. | As proposed Solar absorptance = 0.75 | As proposed Emittance = 0.90 | As proposed Attics | Type: vented with an aperture of 1 ft2 per 300 ft2 of ceiling area. | As proposed Foundations | Type: same as proposed. | As proposed Foundation wall area above and below grade and soil characteristics: same as proposed. | As proposed Opaque doors | A = 40 ft2 | As proposed Orientation: North. | As proposed U-factor: same as fenestration as specified in Table R402.1.2. | As proposed Vertical fenestration other than opaque doors | Total area h = a. The proposed glazing area, where the proposed glazing area is less than 15 percent of the conditioned floor area. b. 15 percent of the conditioned floor area, where the proposed glazing area is 15 percent or more of the conditioned floor area. | As proposed Orientation: equally distributed to four cardinal compass orientations (N, E, S & W). | As proposed U-factor: as specified in Table R402.1.2. | As proposed SHGC: as specified in Table N1102.1.2 except for climate zones without an SHGC requirement, the SHGC shall be equal to 0.40 . | As proposed Interior shade fraction: 0.9 - (0.21 × SHGC for the standard reference design). | Interior shade fraction 0.92 - (0.21 × SHGC as proposed). External shading: none. | As proposed Skylights | None. | As proposed Thermally isolated sunrooms | None. | As proposed Air exchange rate | The air leakage rate at a pressure of 0.2 inch w.g. (50 Pa) shall be Climate Zones 1 and 2: 5 air change per hour. Climate Zones 3 through 8: 3 air changes per hour. The mechanical ventilation rate shall be in addition to the air leakage rate and shall be the same as in the proposed design, but greater than 0.01 x CFA + 7.5 × (Nbr + 1). Where: CFA = conditioned floor area, ft2 Nbr = number of bedrooms Energy recovery shall not be assumed for mechanical ventilation. | The measured air exchange rate b. The mechanical ventilation rate b shall be in addition to the air leakage rate and shall be as proposed. Mechanical ventilation | Where mechanical ventilation is not specified in the proposed design: None. Where mechanical ventilation is specified in the proposed design, the annual vent fan energy use, in units of kWh/yr, shall equal (l/ef) × [0.0876 × CFA + 65.7 × (Nbr + 1)]. Where: ef = the minimum exhaust fan efficacy, a specified in Table R403.6.1, corresponding to a flow rate of 0.01 × CFA + 7.5 × (Nbr + 1) CFA = conditioned floor area, ft2 Nbr = number of bedrooms | As proposed Internal gains | Gain, in units of BTU/day per dwelling unit, shall equal 17.900 + 23.8 × CFA + 4,104 × Nbr Where: CFA = conditioned floor area, ft2 Nbr = number of bedrooms | Same as standard reference design Internal mass | Internal mass for furniture and contents: 8 pounds per square feet of floor area. | Same as standard reference design, plus any additional mass specifically designed as a thermal storage elementc but not integral to the building envelope or structure. Structural mass | For masonry floor slabs: 80 percent of floor area covered by R-2 carpet and pad, and 20 percent of floor directly exposed to room area. | As proposed For masonry basement walls, as proposed, but with insulation as specified in Table R402.1.3 located on the interior side of the walls. | As proposed For other walls, ceilings, floors, and interior walls: wood frame construction. | As proposed Heating systems d, e | For other than electric heating without a heat pump: as proposed. Where the proposed design utilizes electric heating without a heat pump, the standard reference design shall be an air source heat pump meeting the requirements of Section C403 of the IECC - Commercial Provisions. Capacity: sized in accordance with Section N1103.7. | As proposed Cooling systems d, f | As proposed. Capacity: sized in accordance: with Section N1103.7. | As proposed Service water heating d, e, f, g | As proposed. Use: same as proposed design. | As proposed Use, in units of gal/day = 30 + (10 × Nbr) Where: Nbr = number of bedrooms Thermal distribution systems | Duct insulation: in accordance with Section N1103.3.1. A thermal distribution system efficiency (DSE) of 0.88 shall be applied to both the heating and cooling system efficiencies for all systems other than tested duct systems. Exception: For non-ducted heating and cooling systems that do not have a fan, the standard reference design thermal distribution system efficiency (DSE) shall be 1. For tested duct systems, the leakage rate shall be 4 cfm per 100 sf of conditioned floor area at a pressure differential of 0.1-inch w.g. (25 Pa). | Duct insulation: as proposed. As tested or, where not tested, as specified in Table R405.4.2(2). Thermostat | Type: Manual, cooling temperature setpoint = 75 degrees F Heating temperature setpoint = 72 degrees F | Same as standard reference design. | | For SI: 1 square foot = 0.93 m2, 1 British thermal unit = 1055 J, 1 pound per square foot = 4.88 kg/m2, 1 gallon (US) = 3.785 L, °C = (°F - 32)/1.8, 1 degree = 0.79 rad. a. Where required by the code official, testing shall be conducted by an approved party. Hourly calculations as specified in the ASHRAE Handbook of Fundamentals, or the equivalent, shall be used to determine the energy loads resulting from infiltration. b. The combined air exchange rate for infiltration and mechanical ventilation shall be determined in accordance with Equation 43 of 2001 ASHRAE Handbook of Fundamentals, page 26.24 and the “Whole-house Ventilation” provisions of 2001 ASHRAE Handbook of Fundamentals, page 26.19 for intermittent mechanical ventilation. c. Thermal storage element shall mean a component that is not part of the floors, walls or ceilings that is part of a passive solar system, and that provides thermal storage such as enclosed water columns, rock beds, or phase-change containers. A thermal storage element shall be in the same room as fenestration that faces within 15 degrees (0.26 rad) of true south, or shall be connected to such a room with pipes or ducts that allow the element to be actively charged. d. For a proposed design with multiple heating, cooling or water heating systems using different fuel types, the applicable standard reference design system capacities and fuel types shall be weighted in accordance with their respective loads as calculated by accepted engineering practice for each equipment and fuel type present. e. For a proposed design without a proposed heating system, a heating system having the prevailing federal minimum efficiency shall be assumed for both the standard reference design and proposed design. f. For a proposed design home without a proposed cooling system, an electric air conditioner having the prevailing federal minimum efficiency shall be assumed for both the standard reference design and the proposed design. g. For a proposed design with a nonstorage-type water heater, a 40-gallon storage-type water heater having the prevailing federal minimum energy factor for the same fuel as the predominant heating fuel type shall be assumed. For a proposed design without a proposed water heater, a 40-gallon storage-type water heater having the prevailing federal minimum efficiency for the same fuel as the predominant heating fuel type shall be assumed for both the proposed design and standard reference design. h. For residences with conditioned basements, R-2 and R-4 residences, and for townhouses, the following formula shall be used to determine glazing area: AF = As * FA * F Where: AF = Total glazing area. As = Standard reference design total glazing area. FA = (Above-grade thermal boundary gross wall area)/(above-grade boundary wall area + 0.5 × below-grade boundary wall area). F = (Above-grade thermal boundary wall area)/(above-grade thermal boundary wall area + common wall area) or 0.56, whichever is greater. And where: Thermal boundary wall is any wall that separates conditioned space from unconditioned space or ambient conditions. Above-grade thermal boundary wall is any thermal boundary wall component not in contact with soil. Below-grade boundary wall is any thermal boundary wall in soil contact. Common wall area is the area of walls shared with an adjoining dwelling unit. L and CFA are in the same units. * * * R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE * * * [Pursuant to the UCC, delete Section R406.3 (N1106.3) and replace with ‘Reserved’.] * * * [Pursuant to the UCC, delete Section R-406.4 and replace as follows:] EC-R406.4 (N1106.4) Energy rating index. The Energy Rating Index (ERI) shall be a numerical integer value that is based on a linear scale constructed such that the ERI reference design has an Index value of 100 and a residential building that uses no net purchased energy has an Index value of 0. Each integer value on the scale shall represent a 1 percent change in the total energy use of the rated design relative to the total energy use of the ERI reference design. The ERI shall consider all energy used in the residential building. EC-R406.4.1 (N1106.4.1) ERI reference design. The ERI reference design shall be configured such that it meets the minimum requirements of the 2006 International Energy Conservation Code prescriptive requirements. The proposed residential building shall be shown to have an annual total normalized modified load less than or equal to the annual total loads of the ERI reference design. * * * [Pursuant to the UCC, delete Section R406.7.1 and replace as follows:] EC-R406.7.1 (N1106.7.1) Compliance software tools. Documentation verifying that the methods and accuracy of the compliance software tools conform to the provisions of this section shall be provided to the code official. * * * [Pursuant to the UCC, delete Section R406.7.2 and replace as follows:] EC-R406.7.2 (N1106.7.2) Compliance report. Compliance software tools shall generate a report that documents that the home and the ERI score of the rated design complies with Sections R406.2, R406.3 and R406.4. Compliance documentation shall be created for the proposed design and shall be submitted with the application for the building permit. Confirmed compliance documents of the built dwelling shall be created and submitted to the code official for review before a certificate is issued. Compliance reports shall include information in accordance with Sections R406.7.2.1 and R406.7.2.2. EC-R406.7.2.1 (N1106.7.2.1) Proposed compliance report for permit application. Compliance reports submitted with the application for a building permit shall include the following: 1. Building Street address or other building site identification. 2. Declare ERI on title page and building plans. 3. The name of the individual performing the analysis and generating the compliance report. 4. The name and version of the compliance software tool. 5. Documentation of all inputs entered into the software used to produce the results for the reference design and/or the rated home. 6. A certificate indicating that the proposed design has an ERI less than or equal to the appropriate score indicated in Table R406.5 when compared to the ERI reference design. The certificate shall document the building component energy specifications that are included in the calculation, including: component level insulation R-values or U-factors; assumed duct and building envelope air leakage testing results; and the type and rated efficiencies of proposed heating, cooling, mechanical ventilation, and service water-hating equipment to be installed. If on-site renewable energy systems will be installed, the certificate shall report the type and production size of the proposed system. 7. When a site-specific report is not generated, the proposed design shall be based on the worst-case orientation and configuration of the rated home. R406.7.2.2 (N1106.7.2.2) Confirmed compliance report for a certificate of occupancy. A confirmed compliance report submitted for obtaining the certificate of occupancy shall be made site and address specific and include the following: 1. Building street address or other building site identification. 2. Declaration of ERI on title page and on building plans. 3. The name of the individual performing the analysis and generating the compliance report. 4. The name and version of the compliance software tool. 5. Documentation of all inputs entered into the software used to produce the results for the reference design and/or the rated home. 6. A final confirmed certificate indicating that the confirmed rated design of the built home complies with Sections R406.2 (N1106.2) and R406.4 (N1106.4). The certificate shall report the energy features that were confirmed to be in the home, including: component-level insulation R-values or U-factors; results from any required duct system and building envelope air leakage testing; and the type and rated efficiencies of the heating cooling, mechanical ventilation, and service water- heating equipment installed. Where on-site renewable energy systems have been installed on or in the home, the certificate shall report the type and production size of the installed home. * * * [Pursuant to the UCC, delete Section R406.7.5 and R406.7.6:] * * * [Pursuant to the UCC, add Section R406.8 as follows:] EC-R406.8 (N1106.8) Calculation software tools. Calculation software, where used, shall be in accordance with Sections R406.8.1 (N1106.8.1) through R406.8.3 (N1106.8.3). EC-R406.8.1 (N1106.8.1) Minimum capabilities. Calculation procedures used to comply with this section shall be software tools capable of calculating the ERI as described in Section R406.4 (N1106.4), and shall include the following capabilities: 1. Computer generation of the ERI reference design using only the input for the rated design. The calculation shall not allow the user to directly modify the building component characteristics of the ERI reference design. 2. Calculation of the whole-building, as a single zone, sizing for the heating and cooling equipment in the ERI reference design residence in accordance with Section R403.7 (N1103.7). 3. Calculations that account for the effects of indoor and outdoor temperatures and part-load ratios on the performance of heating, ventilation, and air-conditioning equipment based on climate and equipment sizing. 4. Printed code official inspection checklist listing each of the rated design component characteristics determined by the analysis to provide compliance, along with their respective performance ratings. EC-R406.8.2 (N1106.8.2) Specific Approval. Performance analysis tools meeting the applicable sections of Section R406 (N1106) shall be approved. Tools are permitted to be approved based on meeting a specified threshold for a jurisdiction. The code official shall approve tools for a specified application or limited scope. EC-R406.8.3 (N1106.8.3) Input values. Where calculations require input values not specified by Section R402 (N1102), R403 (N1103), R404 (N1104), and R405 (N1105), those input values shall be taken from an approved source. * * * SUBCODE "F" (THE PHILADELPHIA FIRE CODE) Article F-1.0 Adoption of the "2018 International Fire Code", with additions, deletions and amendments. § F-1.1 The "2018 International Fire Code" as published by the International Code Council is hereby adopted as the Philadelphia Fire Code, with such additions, deletions and amendments as set forth in § F-1.2. Editor's note: The 2018 International Fire Code, as revised by Philadelphia, can be found at: https://codes.iccsafe.org/content/PHLFC2018 § F-1.2 The 2018 International Fire Code, copies of which are on file with the Fire Department, is incorporated as if fully set forth herein, subject to the following additions, deletions and amendments, including errata issued by the International Code Council. § F-1.2.1 The numbers of all local amendments shall be preceded with the prefix "F-". § F-1.2.2 Throughout the code, references to "International" codes or "ICC" codes shall be deemed to refer to the "Philadelphia" codes of the same name. PART I – ADMINISTRATIVE CHAPTER 1 SCOPE AND ADMINISTRATION Delete Chapter 1 in its entirety and replace as follows: SECTION F-101 GENERAL F-101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Fire Code and shall be cited as such and will be referred to herein as the "Philadelphia Fire Code" or "this code". F-101.2 Scope. The Philadelphia Fire Code establishes regulations affecting or relating to structures, processes, premises and safeguards regarding: 1. The hazard of fire and explosion arising from the storage, handling or use of structures, materials or devices. 2. Conditions hazardous to life, property or public welfare in the occupancy of structures or premises. 3. Fire hazards in a structure or on the premises from occupancy or operations. 4. Matters related to the construction, extension, repair, alteration or removal of fire suppression or fire alarm systems. 5. Conditions affecting the safety of fire fighters and emergency responders during emergency operations. The provisions in this code related to construction are regulated by the International Building Code with local and state amendments found in other Subcodes. F-101.2.1 Appendices. Provisions in the appendices shall not apply unless specifically adopted. Appendix O is adopted as a local Appendix. F-101.3 Intent. The purpose of this code is to establish the minimum requirements consistent with nationally recognized good practice for providing a reasonable level of life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises and to provide safety to fire fighters and emergency responders during emergency operations. F-101.4 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are as set forth in the Philadelphia Administrative Code. F-101.5 Codes referenced. Where this code references any of the International Codes published by the International Code Council, it shall be assumed that the reference means the applicable Philadelphia code. SECTION F-102 APPLICABILITY F-102.1 Construction and design provisions. The construction and design provisions of this code shall apply to: 1. Structures, facilities and conditions arising after the adoption of this code. 2. Existing structures, facilities and conditions not legally in existence at the time of adoption of this code. 3. Existing structures, facilities and conditions where required in Chapter 11. 4. Existing structures, facilities and conditions that, in the opinion of the fire code official, constitute a distinct hazard to life or property. F-102.2 Administrative, operational and maintenance provisions. The administrative, operational and maintenance provisions of this code shall apply to: 1. Conditions and operations arising after the adoption of this code. 2. Existing conditions and operations. F-102.2.1 Operational provisions. Operational provisions shall include, but are not limited to, requirements for: Storage, Signage (signs, placards and labels), Clearance from sources of ignition, Vehicle impact protection (Section 312), Hazards to fire fighters (Section 316), Fire apparatus access roads (Section 503), Premises identification (Section 505), Fire protection water supplies (Section 507), Portable unvented heaters (Section 603.4), Electrical equipment and wiring hazards (Section 604), Natural decorative vegetation (Section 806), Decorative materials and artificial decorative vegetation (Section 807), Portable fire extinguishers (Section 906), Fire department connections (Section 912), Maximum allowable quantity of hazardous materials per control area (Section 5003.1.1), and Hazardous material control areas (Section 5003.8.3), F-102.3 Application of building code. The design and construction of new structures shall comply with the Philadelphia Building Code and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the Philadelphia Building Code, shall be made in accordance with the Philadelphia Building Code. F-102.4 Application of residential code. Where structures are designed and constructed in accordance with the Philadelphia Residential Code, the provisions of this code shall apply as follows: 1. Construction and design provisions of this code pertaining to the exterior of the structure shall apply including, but not limited to, premises identification, fire apparatus access and water supplies. Where interior or exterior systems or devices are installed, construction permits required by the Administrative Code shall apply. 2. Administrative, operational and maintenance provisions of this code shall apply. F-102.5 Historic buildings. The fire code official is authorized to require that designated historic buildings be provided with an approved fire protection plan as required in Section 1103.1.1. F-102.6 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 80, and such codes and standards shall be considered to be part of the requirements of this code to the prescribed extent of each such reference. F-102.6.1 Conflicts. Where conflicts occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply. F-102.6.2 Provisions in referenced codes and standards. Where a reference to a referenced code or standard includes subject matter that is within the scope of this code, the provisions of this code, as applicable, shall take precedence over the provisions in the referenced code or standard. F-102.7 Subjects not regulated by this code. Where applicable standards or requirements are not set forth in this code, or are contained within other laws, codes, regulations, ordinances or bylaws adopted by the jurisdiction, compliance with applicable standards of the National Fire Protection Association or other nationally recognized fire safety standards, as approved, shall be deemed as prima facie evidence of compliance with the intent of this code. Nothing herein shall derogate from the authority of the fire code official to determine compliance with codes or standards for those activities or installations within the fire code official's jurisdiction or responsibility. F-102.8 Matters not provided for. Requirements that are essential for the public safety of an existing or proposed activity, building or structure, or for the safety of the occupants thereof, that are not specifically provided for by this code, shall be determined by the fire code official. F-102.9 Conflicting provisions. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall govern. Where, in a specific case, different Sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. F-102.10 Other laws. The provisions of this code shall not be deemed to nullify any provisions of local, state or federal law. F-102.11 Application of references. References to Chapter or Section numbers, or to provisions not specifically identified by number, shall be construed to refer to such Chapter, Section or provision of this code. SECTION F-103 UNSAFE CONDITIONS F-103.1 Hazardous conditions. The fire code official in charge of a location that has hazardous conditions that present imminent danger to building occupants shall be authorized to order the immediate evacuation of any building that is deemed unsafe due to such hazardous conditions. Persons so notified shall immediately leave the structure or premises and shall not enter or re-enter until authorized to do so by the fire code official or the fire department official in charge of the incident. F-103.2 Fire protection systems. Where any required fire protection system or part thereof becomes inoperative and affects the fire safety of a structure or the occupants therein, the fire code official shall order the system to be repaired and returned to service and is authorized to order the structure vacated until the inoperative system is repaired and returned to service. SECTION F-104 GENERAL AUTHORITY AND RESPONSIBILITIES F-104.1 Fire investigations. The fire code official shall have the authority to investigate the cause, origin and circumstances of any fire, explosion or other hazardous condition. Information that could be related to trade secrets or processes shall not be made part of the public record except as directed by a court of law. F-104.1.1 Assistance from other agencies. Police and other enforcement agencies shall have the authority to render necessary assistance in the investigation of fires when requested to do so. F-104.2 Authority at fires and other emergencies. 1. The fire department official in charge at the scene of a fire or other emergency involving the protection of life or property or any part thereof, shall have the authority to direct such operation as necessary to extinguish or control any fire, perform any rescue operation, investigate the existence of suspected or reported fires, gas leaks or other hazardous conditions or situations, or take any other action necessary in the reasonable performance of duty. 2. The fire department official in charge at the scene of a fire or other emergency involving the protection of life or property or any part thereof, shall have the authority to direct uniformed Fire Department personnel, including but not limited to Firefighters and Fire Service Paramedics, to engage in such actions that are necessary in order to complete the assignment, including but not limited to fire rescue, fire abatement, and emergency medical services. Because of their legislative authority to act and actual participation in such operations, fire service paramedics shall continue to be considered firemen for the purposes of the act of June 24, 1968 (P.L. 237, No. 111) referred to as the Policemen and Firemen Collective Bargaining Act. 3. In the exercise of such power, the fire official is authorized to prohibit any person, vehicle, vessel or thing from approaching the scene and is authorized to remove, or cause to be removed or kept away from the scene, any vehicle, vessel or thing which could impede or interfere with the operations of the fire department and, in the judgment of the fire official, any person not actually and usefully employed in the extinguishing of such fire or in the preservation of property in the vicinity thereof. F-104.2.1 Barricades. The fire department official in charge at the scene of an emergency is authorized to place ropes, guards, barricades or other obstructions across any street, alley, place or private property in the vicinity of such operation so as to prevent accidents or interference with the lawful efforts of the fire department to manage and control the situation and to handle fire apparatus. F-104.2.2 Obstructing operations. No person shall obstruct the operations of the fire department in connection with extinguishment or control of any fire, or actions relative to other emergencies, or disobey any lawful command of the fire department official in charge of the emergency, or any part thereof, or any lawful order of a police officer assisting the fire department. F-104.2.3 Systems and devices. No person shall render a system or device inoperative during an emergency unless by direction of the fire chief or fire department official in charge of the incident. SECTION F-105 PERMITS AND LICENSES F-105.1 Permits and licenses required. Permits and licenses required by this code shall be obtained from the Department of Licenses and Inspections in accordance with this Chapter and the Philadelphia Administrative Code. F-105.1.1 Licenses. Licenses issued pursuant to this code shall be issued for a period of one year and shall be renewed annually by the license holder. F-105.1.2 Operational permits. Operational permits allow the applicant to conduct an operation or a business for a prescribed period. Such permits are not renewable. F-105.1.3 Assisted operation permits. An assisted operation permit provides for appropriate City agency assistance or oversight for the specified activities in Section F-105.8. Such permits are not renewable. F-105.1.4 Construction permits. Construction permits authorize the installation or modification of systems and equipment. Such permits are subject to the provisions of Chapter 3 of the Administrative Code. F-105.2 Inspection authorized. Before a permit or license is approved, the fire code official is authorized to inspect the receptacles, buildings, devices, premises, storage spaces or areas to be used to determine compliance with this code or any operational constraints required. F-105.3 Conditions of a license or permit. A license or permit issued pursuant to this code shall constitute permission to maintain, store or handle materials; or to conduct processes that produce conditions hazardous to life or property; or to install equipment utilized in connection with such activities; or to install or modify any fire protection system or equipment or any other construction, equipment installation or modification in accordance with the provisions of this code. Such permission shall not be construed as authority to violate, cancel or set aside any of the provisions of The Philadelphia Code and adopted regulations. F-105.4 Posting. Issued permits and licenses shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official. F-105.5 Revocation. The fire code official is authorized to revoke a permit or license issued under the provisions of this code where it is found by inspection or otherwise that there has been a false statement or misrepresentation as to the material facts in the application or documents on which the permit, license or approval was based. F-105.6 Licenses required. The licenses required by Sections F-105.6.1 through F-105.6.7 shall be obtained from the Department of Licenses and Inspections in accordance with this Chapter and the Philadelphia Administrative Code prior to conducting the regulated activity at any premises. Licenses shall remain in effect until renewed annually or suspended or revoked by the fire code official. F-105.6.1 Required hazardous materials handling licenses. The Department of Licenses and Inspections is authorized to issue hazardous materials licenses for the manufacture or storage of the types and quantities of materials set forth in Sections F-105.6.1.1 through F-105.6.1.10. Such materials may also be subject to additional fees as established by Section F-5001.7. F-105.6.1.1 Aerosol products. A hazardous materials license is required to manufacture, store or handle an aggregate quantity of Level 2 or Level 3 aerosol products in excess of 500 pounds (227 kg) net weight. F-105.6.1.2 Battery systems. A hazardous materials license is required to maintain stationary lead-acid battery systems having a liquid capacity of more than 50 gallons (189 L). F-105.6.1.3 Compressed gases. A hazardous materials license is required for the storage, use or handling at normal temperature and pressure (NTP) of compressed gases in excess of the amounts listed in Table F-105.6.1.3. Exception: Vehicles equipped for and using compressed gas as a fuel for propelling the vehicle. TABLE F-105.6.1.3 LICENSE AMOUNTS FOR COMPRESSED GASES TYPE OF GAS | AMOUNT (cubic feet at NTP) TYPE OF GAS | AMOUNT (cubic feet at NTP) Carbon dioxide used in carbon dioxide enrichment systems | 875 (100 lbs.) Carbon dioxide used in insulated liquid carbon dioxide beverage dispensing applications | 875 (100 lbs.) Corrosive | 200 Flammable (except cryogenic fluids and liquefied petroleum gases) | 200 Highly toxic | Any Amount Inert and simple asphyxiant | 6,000 Oxidizing (including oxygen) | 504 Pyrophoric | Any Amount Toxic | Any Amount | For SI: 1 cubic foot = 0.02832 m 3. F-105.6.1.4 Cryogenic fluids. A hazardous materials license is required to produce, store, transport on site, use, handle or dispense cryogenic fluids in excess of the amounts listed in Table F-105.6.1.4. Exception: Vehicles equipped for and using cryogenic fluids as a fuel for propelling the vehicle or for refrigerating the lading. TABLE F-105.6.1.4 LICENSE AMOUNTS FOR CRYOGENIC FLUIDS TYPE OF CRYOGENIC FLUID | INSIDE BUILDING (gallons) | OUTSIDE BUILDING (gallons) Flammable | More than 1 | 60 Inert | 60 | 500 Oxidizing (includes oxygen) | 10 | 50 Physical or health hazard not indicated above | Any Amount | Any Amount For SI: 1 gallon = 3.785 L. F-105.6.1.5 Dry cleaning plants. A hazardous materials license is required where dry cleaning solvents are used at a dry cleaning plant. F-105.6.1.6 Explosives. A hazardous materials license is required for the manufacture, storage, handling, use or sale of any quantity of explosive, explosive material, fireworks, or pyrotechnic special effects within the scope of Chapter 56. For the display of fireworks, in lieu of a hazardous material license, an Assisted Operation Permit shall be required in accordance with Section F-105.8. For the use of explosives, in lieu of a hazardous material license, an operational permit shall be required in accordance with Section F-105.7.1. Exception: Consumer fireworks, 1.4G (Class C, Common), as regulated through licensure by the Pennsylvania Department of Agriculture pursuant to Act 43 of 2017, amending the Tax Reform Code of 1971 (72 P.S. §§ 9401 - 9416). F-105.6.1.7 Flammable and combustible liquids. A hazardous materials license is required: 1. To use or operate a pipeline for the transportation within facilities of flammable or combustible liquids. This requirement shall not apply to the offsite transportation in pipelines regulated by the Department of Transportation (DOTn) nor does it apply to piping systems. 2. To store, handle or use Class I liquids in excess of 5 gallons (19 L) in a building or in excess of 10 gallons (37.9 L) outside of a building, except that a permit is not required for the following: 2.1. The storage or use of Class I liquids in the fuel tank of a motor vehicle, aircraft, motorboat, mobile power plant or mobile heating plant, unless such storage, in the opinion of the fire code official, would cause an unsafe condition. 2.2. The storage or use of paints, oils, varnishes or similar flammable mixtures where such liquids are stored for maintenance, painting or similar purposes for a period of not more than 30 days. 3. To store, handle or use Class II or Class IIIA liquids in excess of 25 gallons (95 L) in a building or in excess of 60 gallons (227 L) outside a building, except for fuel oil used in connection with oil burning equipment. 4. To store, handle or use Class IIIB liquids in tanks or portable tanks for fueling motor vehicles at motor fuel-dispensing facilities or where connected to fuel-burning equipment. Exception: Fuel oil and used motor oil used for space heating or water heating. 5. To remove Class I or II liquids from an underground storage tank used for fueling motor vehicles by any means other than the approved, stationary on-site pumps normally used for dispensing purposes. 6. To operate tank vehicles, equipment, tanks, plants, terminals, wells, fuel-dispensing stations, refineries, distilleries and similar facilities where flammable and combustible liquids are produced, processed, transported, stored, dispensed or used. 7. To change the type of contents stored in a flammable or combustible liquid tank to a material that poses a greater hazard than that for which the tank was designed and constructed. 8. To manufacture, process, blend or refine flammable or combustible liquids. 9. To engage in the dispensing of liquid fuels into the fuel tanks of motor vehicles at commercial, industrial, governmental or manufacturing establishments in accordance with Section 5706.5.4 or to engage in on- demand mobile fueling operations in accordance with Section 5707. 10. To utilize a site for the dispensing of liquid fuels from tank vehicles into the fuel tanks of motor vehicles, marine craft and other special equipment at commercial, industrial, governmental or manufacturing establishments in accordance with Section 5706.5.4 or, where required by the fire code official, to utilize a site for on-demand mobile fueling operations in accordance with Section 5707. F-105.6.1.8 Hazardous materials. A hazardous materials license is required to store, transport on site, dispense, use or handle hazardous materials in excess of the amounts listed in Table F-105.6.1.8 and for extremely hazardous substances in accordance with Section F-105.6.8. TABLE F-105.6.1.8 LICENSE AMOUNTS FOR HAZARDOUS MATERIALS TYPE OF MATERIAL | AMOUNT TYPE OF MATERIAL | AMOUNT Combustible liquids | | See Section F-105.6.1.7 Corrosive materials | Gases | See Section F-105.6.1.3 Liquids | 55 gallons Solids | 1,000 pounds Explosive materials | | See Section F-105.6.1.6 Flammable materials | Gases | See Section F-105.6.1.3 Liquids | See Section F-105.6.1.7 Solids | 100 pounds Highly toxic materials | Gases | See Section F-105.6.1.3 Liquids | Any Amount Solids | Any Amount Oxidizing materials (Gases) | | See Section F-105.6.1.3 Oxidizing materials (Liquids) | Class 4 | Any Amount Class 3 | 1 gallon a Class 2 | 10 gallons Class 1 | 55 gallons Oxidizing materials (Solids) | Class 4 | Any Amount Class 3 | 10 pounds b Class 2 | 100 pounds Class 1 | 500 pounds Organic peroxides (Liquids) | Class I | Any Amount Class II | Any Amount Class III | 1 gallon Class IV | 2 gallons Class V | No Permit Required Organic peroxides (Solids) | Class I | Any Amount Class II | Any Amount Class III | 10 pounds Class IV | 20 pounds Class V | No Permit Required Pyrophoric materials | Gases | Any Amount Liquids | Any Amount Solids | Any Amount Toxic materials | Gases | See Section F-105.6.1.3 Liquids | 10 gallons Solids | 100 pounds Unstable (reactive) materials (Liquids) | Class 4 | Any Amount Class 3 | Any Amount Class 2 | 5 gallons Class 1 | 10 gallons Unstable (reactive) materials (Solids) | Class 4 | Any Amount Class 3 | Any Amount Class 2 | 50 pounds Class 1 | 100 pounds Water-reactive materials (Liquids) | Class 3 | Any amount Class 2 | 5 gallons Class 1 | 55 gallons Water-reactive materials (Solids) | Class 3 | Any amount Class 2 | 50 pounds Class 1 | 500 pounds | | For SI: 1 gallon = 3.785 L, 1 pound = 0.454 kg. a. 20 gallons where Table 5003.1.1(1) Note k applies and hazard identification signs in accordance with Section 5003.5 are provided for quantities of 20 gallons or less. b. 200 pounds where Table 5003.1.1(1) Note k applies and hazard identification signs in accordance with Section 5003.5 are provided for quantities of 200 pounds or less. F-105.6.1.9 Magnesium. A hazardous materials license is required to melt, cast, heat treat or grind more than 10 pounds (4.54 kg) of magnesium. F-105.6.1.10 Pyroxylin plastics. An operational permit is required for storage or handling of more than 25 pounds (11 kg) of cellulose nitrate (pyroxylin) plastics, and for the assembly or manufacture of articles involving pyroxylin plastics. F-105.6.2 Family child day care. A license to operate a Family Child Day Care Facility shall be obtained from the Department of Licenses and Inspections. Such license shall include an annual fire safety inspection. No license shall be issued under this Section unless the applicant has secured a Commercial Activity License to the extent required by Title 19 of The Philadelphia Code and the applicant has met the requirements of Section 6-814 of The Philadelphia Code (Lead-Safe Certification for Family Child Day Care Facilities) and the requirements of this code. F-105.6.3 High-rise building. A license is required to operate a high-rise building. Such license shall be obtained from the Department of Licenses and Inspections. The fire code official shall inspect high-rise buildings for compliance with this code. The owner, manager or operator of a high-rise building shall pay an annual license fee based on the gross square footage of floor area as set forth in the Philadelphia Administrative Code. Exception: Portions of buildings that are subject to the rental license requirements of Section 9-3902 of The Philadelphia Code. F-105.6.4 Repair garages and motor fuel-dispensing facilities. A license is required for operation of repair garages and automotive, marine and fleet motor fuel-dispensing facilities. This license shall be inclusive of the storage of hazardous materials (F-105.6.8) and cutting and welding operations (F-105.6.7) such that those additional licenses shall not also be required. F-105.6.5 Storage of scrap tires and tire byproducts. A license is required to establish, conduct or maintain storage of scrap tires and tire byproducts that exceed 2,500 cubic feet (71 m 3) of total volume of scrap tires and for indoor storage of tires and tire byproducts. The Tire Dealer License required by Section 9-621 of The Philadelphia Code shall satisfy this requirement. F-105.6.6 Waste handling. A license is required for the operation of wrecking and salvage yards, salvage facilities and other waste material-handling facilities. The provisions of this code as well as those of Section 9-613 of The Philadelphia Code shall apply to this license. This license shall be inclusive of the storage of hazardous materials (F-105.6.8) and cutting and welding operations (F-105.6.7) such that those additional licenses shall not also be required. F-105.6.7 Cutting and welding. A license is required to conduct cutting or welding operations. Exception: Cutting and welding performed as part of a permitted construction activity. F-105.6.8 Extremely hazardous substances. A license is required for quantities of extremely hazardous substances regulated by Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA Title III - also known as the Emergency Planning and Community Right-to-Know Act) as listed in the United States Environmental Protection Agency's List of Lists. Such license is administered through the Office of Emergency Management. F-105.7 Required operational permits. The Department of Licenses and Inspections is authorized to issue the required operational permits for the operations set forth in Sections F-105.7.1 through F-105.7.3. F-105.7.1 Explosives. An operational permit is required for the handling or use of any quantity of explosive, explosive material, fireworks, or pyrotechnic special effects within the scope of Chapter 56. For the display of fireworks an Assisted Operation Permit shall be required in accordance with Section F-105.8. Exception: Consumer fireworks, 1.4G (Class C, Common), as regulated by the Pennsylvania Department of Agriculture pursuant to Act 43 of 2017, amending the Tax Reform Code of 1971 (72 P.S. §§ 9401 - 9416). F-105.7.2 Temporary tents. An operational permit is required to operate a temporary tent having an area in excess of 400 square feet (37 m 2). Exceptions: 1. Tents used exclusively for recreational camping purposes. 2. Funeral tents and curtains, or extensions attached thereto, when used for funeral services. 3. Tents open on all sides which comply with all of the following: 3.1. Individual tents shall have a maximum size of 700 square feet (65 m2). 3.2. The aggregate area of multiple tents placed side by side without a fire break clearance of not less than 12 feet (3658 mm) shall not exceed 700 square feet (65 m2) total. 3.3. A minimum clearance of 12 feet (3658 mm) to structures and other tents shall be provided. F-105.7.3 Open burning. An operational permit as required by Sections 307.2 and 308.2, in the form of written approval from the fire code official, is required for the kindling or maintaining of an open fire or a fire on any public street, alley, road, or other public or private ground. Instructions and stipulations of the permit shall be adhered to. Exception: Recreational fires. F-105.8 Required Assisted Operation Permits. The fire code official is authorized to issue assisted operations permits for activities as set forth in Sections F-105.8.1 through F-105.8.2. F-105.8.1 Pyrotechnic special effects material. An Assisted Operation Permit is required for use and handling of pyrotechnic special effects material. F-105.8.2 Fireworks display. An Assisted Operation Permit is required for each event of indoor and outdoor use of fireworks. Where a single show has a series of performance dates in a theater, sports arena or similar venue, such series of dates shall be considered one event for the purposes of this permit, provided there is no change from the approved fireworks or pyrotechnic displays. F-105.8.2.1 Bond required. Pursuant to Act 43 of 2017, amending the Tax Reform Code of 1971 (72 P.S. §§ 9401 - 9416), a bond shall be submitted by the applicant in a sum not less than fifty thousand dollars ($50,000) conditioned for the payment of all damages which may be caused to a person or property by reason of the display and arising from an act of the permit holder or an agent, an employee or a subcontractor of the permit holder. F-105.8.2.2 Extensions. Pursuant to Act 43 of 2017, amending the Tax Reform Code of 1971 (72 P.S. §§ 9401 - 9416), if, because of unfavorable weather, the display for which a permit has been granted does not occur at the time authorized by the permit, the person to whom the permit was issued may within 24 hours apply for an extension to the fire code official. Upon receiving the request for extension, the fire code official shall determine the validity of the request and, where approved, shall extend the provisions of the permit to the date designated within the request, which shall be not later than one week after the date originally designated in the permit. The extension of time shall be granted without the payment of an additional fee and without requiring a bond other than the bond given for the original permit, the provisions of which shall extend to and cover all damages which may be caused by reason of the display occurring at the extended date and in the same manner and to the same extent as if the display had occurred at the date originally designated in the permit. F-105.9 Required construction permits. The Department of Licenses and Inspections is authorized to issue construction permits pursuant to Chapter 3 of the Administrative Code for work as set forth in Sections F-105.9.1 through F-105.9.14. Maintenance performed in accordance with this code is not considered to be a modification and does not require a permit. Exception: Pursuant to the Pennsylvania Propane and Liquefied Petroleum Gas Act (35 P. S. § 1329.16), a construction permit is not required from the City of Philadelphia for installation of or modification to an LP-gas system. Such installations are regulated by the Pennsylvania Department of Labor and Industry F-105.9.1 Automatic fire-extinguishing systems. A construction permit is required for installation of or modification to an automatic fire-extinguishing system. F-105.9.2 Emergency responder radio coverage system. A construction permit is required for installation of or modification to emergency responder radio coverage systems and related equipment. Approval of the Fire Department is required before a construction permit may be issued. Maintenance performed in accordance with this code is not considered to be a modification and does not require a construction permit. F-105.9.3 Fire alarm and detection systems and related equipment. A construction permit is required for installation of or modification to fire alarm and detection systems and related equipment. F-105.9.4 Fire pumps and related equipment. A construction permit is required for installation of or modification to fire pumps and related fuel tanks, jockey pumps, controllers and generators. F-105.9.5 Flammable and combustible liquids. A construction permit is required: 1. To install, repair or modify a pipeline for the transportation of flammable or combustible liquids. 2. To install, construct or alter equipment, tanks, plants, terminals, wells, fuel-dispensing stations, refineries, distilleries and similar facilities where flammable and combustible liquids are produced, processed, transported, stored, dispensed or used. 3. To install, alter, remove, abandon or otherwise dispose of a flammable or combustible liquid tank. F-105.9.6 Gates and barricades across fire apparatus access roads. A construction permit is required for the installation of or modification to a gate or barricade across a fire apparatus access road. F-105.9.7 High-piled combustible storage. A construction permit is required for the installation of or modification to structure exceeding 500 square feet (46 m 2), including aisles, for high-piled combustible storage. F-105.9.8 Industrial ovens. A construction permit is required for installation of industrial ovens covered by Chapter 30. F-105.9.9 Outdoor assembly event. The Department of Licenses and Inspections is authorized to require a permit to conduct an outdoor assembly event where planned attendance exceeds 1,000 persons. F-105.9.10 Private fire hydrants. A construction permit is required for the installation or modification of private fire hydrants. F-105.9.11 Smoke control or smoke exhaust systems. A construction permit is required for installation of or alteration to smoke control or smoke exhaust systems. F-105.9.12 Solar photovoltaic power systems. A construction permit is required to install or modify solar photovoltaic power systems. F-105.9.13 Special event structure. The Department of Licenses and Inspections is authorized to require a permit to erect and take down a temporary special event structure pursuant to Section A-302.11 of the Administrative Code. F-105.9.14 Spraying or dipping. A construction permit is required to install or modify a spray room, dip tank or booth. F-105.9.15 Standpipe systems. A construction permit is required for the installation, modification or removal from service of a standpipe system. F-105.9.16 Temporary membrane structures. A construction permit is required to erect an air-supported temporary membrane structure in excess of 400 square feet (37 m 2). SECTION F-106 MAINTENANCE F-106.1 Maintenance of safeguards. Where any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this code, or otherwise installed, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with this code and applicable referenced standards. F-106.2 Testing and operation. Equipment requiring periodic testing or operation to ensure maintenance shall be tested or operated as specified in this code. F-106.2.1 Test and inspection records. Required test and inspection records and reports of same shall be available to the fire code official at all times. Such reports as the fire code official or this code designates, shall be submitted to the fire code official. F-106.2.2 Re-inspection and testing. Where any work or installation does not pass an initial test or inspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be reinspected or re-tested and the results resubmitted to the fire code official as appropriate. F-106.3 Recordkeeping. A record of periodic inspections, tests, servicing and other operations and maintenance shall be maintained on the premises or other approved location for not less than 3 years, or a different period of time where specified in this code or referenced standards. Records shall be made available for inspection by the fire code official, and a copy of the records shall be provided to the fire code official on request. The fire code official is authorized to prescribe the form and format of such recordkeeping. The fire code official is authorized to require that certain required records be filed with the fire code official and may impose a processing fee, not to exceed one hundred dollars ($100), that must be paid upon submission of the report. F-106.4 Supervision. Maintenance and testing shall be under the supervision of a responsible person who shall ensure that such maintenance and testing is conducted at specified intervals in accordance with this code. F-106.5 Rendering equipment inoperable. Portable or fixed fire-extinguishing systems or devices and fire- warning systems shall be provided with ready access and shall not be rendered inoperative except as necessary during emergencies, maintenance, repairs, alterations, drills or prescribed testing. The restoration of protection shall be diligently pursued. F-106.5.1 Fire Department notification. The Fire Department shall be notified by telephone at 215-922-6000 of the shutdown of any fire protection system that affects more than one story or more than 30,000 square feet on one story. This notification shall occur immediately upon knowledge of an unplanned loss of protection and prior to the interruption of protection in the case of tests, maintenance, repairs, alterations or additions. The notification shall include the extent of and reason for such interruption of protection and the anticipated length of outage. The Fire Department shall be notified again immediately upon restoration of service. F-106.6 Owner/occupant responsibility. Correction and abatement of violations of this code shall be the responsibility of the owner. If an occupant creates, or allows to be created, hazardous conditions in violation of this code, the occupant shall also be held responsible for the abatement of such hazardous conditions. F-106.7 Overcrowding. Overcrowding or admittance of any person beyond the approved capacity of a building or a portion thereof shall not be allowed. The fire code official, on finding any overcrowding conditions, or on finding any condition that constitutes a life safety hazard, in addition to any other remedy under this code, shall be authorized to cause the event to be stopped until such condition is corrected. F-106.8 Obstructions. Obstruction of aisles, passageways or other means of egress constitutes a violation of this code. Upon finding any obstruction in an aisle, passageway or other means of egress, or upon finding any condition that constitutes a life safety hazard, the fire code official, in addition to any other remedy under this code, is authorized to cause any event or activity to be stopped until such condition or obstruction is corrected. SECTION F-107 APPEALS OF VIOLATIONS F-107.1 Appeals and requests for variance. Violations of the Fire Code may be appealed by the owner of a property to the Fire Commissioner for relief from or time to correct the violations. To file an appeal the owner shall submit the appropriate appeal form and a check or money order in the amount specified in the Philadelphia Administrative Code within 30 days of the date of the Violation Notice. If the violation has been reviewed by Municipal Court or the Court of Common Pleas and has been sent to the Fire Commissioner for review, the owner shall comply with the time frame specified in the court's order. If an action desired by an owner would place the property in violation of this code, the owner may apply to the Fire Commissioner for a variance from code requirements. Appeals and requests for variance shall be heard by the Board of Safety and Fire Prevention. The board will make recommendations to the Fire Commissioner who will render a decision on the appeal or variance request. F-107.2 Fees. The fee for filing an appeal shall be as set forth in Section A-904 of the Administrative Code. SECTION F-108 BOARD OF SAFETY AND FIRE PREVENTION F-108.1 Board of Safety and Fire Prevention authorized. Pursuant to subsection 3-100(g) and Section 3-917 of the Philadelphia Home Rule Charter, the Mayor may, upon the recommendation of the Fire Commissioner or upon the Mayor's own volition, appoint a board to act in an advisory capacity to the Fire Department. This board shall be known as the Board of Safety and Fire Prevention and shall consist of a representative of the Fire Department, a representative of the Department of Licenses and Inspections, and five other members appointed by the Mayor. One of the five shall be a qualified fire protection engineer and another shall be a qualified fire protection specialist with a background in hazardous materials or in the petroleum industry. The remaining members shall be persons who are qualified by experience and training to deliberate matters pertaining to hazards of fire, explosion, hazardous conditions, fire protection systems and life safety. F-108.2 Duties of the board. The Board of Safety and Fire Prevention shall act in an advisory capacity to the Fire Commissioner in matters of fire safety and fire prevention and as required under this Section. F-108.3 Appeals and advice. The Board of Safety and Fire Prevention shall handle appeals as set forth in the Administrative Code and offer advice on interpreting this code and the regulations issued under it, suggest changes to the regulations and Code, suggest standards and procedures for good fire prevention practices, and offer advice as to standards of fire safety practice in the manufacture, storage, sale, transportation and use of new materials which are combustible, flammable, explosive, toxic or which may constitute a fire hazard. SECTION F-109 REDUCTION OR ELIMINATION OF LIFE SAFETY AND FIRE PROTECTION SERVICES F-109.1 Limitation on reductions or eliminations of fire companies. The Fire Department shall not temporarily or permanently reduce or eliminate any ladder or engine company situated in the City unless all of the following requirements have been met: 1. The Fire Department has provided written notice of the proposed reduction or elimination to uniformed Fire Department personnel assigned to the affected company, to labor organizations representing those personnel and to members of the public served by the company where the proposed reduction or elimination will take place. The Fire Department may place an advertisement in a newspaper of general circulation within the affected area to provide the required public notice. 2. The Fire Department has secured a comprehensive study to be conducted by an independent third party which shall include, but be not limited to, detailed projections of savings to be achieved by the proposed reduction or elimination, and analyses of the impact of the proposed reduction or elimination on emergency response time, delivery of emergency services to the public and the safety of firefighters. Once the study has been completed, it shall be made available to any interested party that requests a copy. 3. The Fire Department has convened public hearings to receive feedback on the proposed reduction or elimination in firefighting and emergency services and the results of the study. The Fire Department shall accept written responses relating to the study's findings. F-109.1.1 Independent third party. As used in this subsection, the term "independent third party" shall refer to an individual, association or corporation that has experience in the areas of public safety and firefighting. F-109.2 Opposition to reductions or eliminations. When a labor organization representing uniformed Fire Department personnel registers its opposition to the findings contained within a study conducted under this subsection or to the proposed reduction or elimination of engine or ladder companies, through either oral testimony at a public hearing or in writing, the Fire Department shall not proceed with the reduction or elimination. Instead, the Fire Department must negotiate in good faith with the labor organization to resolve any disputes over public and firefighter safety arising from each proposed reduction or closure. F-109.3 Resolution of disputes. 1. In the event that the Fire Department and the labor organization representing the uniformed Fire Department personnel do not resolve all issues related to the proposed reduction or elimination of any fire company, the labor organization may, within ninety days of commencement of the negotiation, submit any unresolved issues to final and binding interest arbitration. 2. Interest arbitration proceedings under this subsection shall be conducted before a three-person board of arbitrators, who will be selected utilizing the procedure under Section 4(b) of the Act of June 24, 1968 (P.L. 237, No. 111), referred to as the Policemen and Firemen Collective Bargaining Act. The determination of a majority of the board of arbitrators shall be final on the issue or issues in dispute and shall be binding upon the Fire Department. 3. Each proposed company closure shall be subject to negotiation and arbitration, and no company may be reduced or eliminated absent an arbitration award concluding that the proposed reduction or elimination will not compromise fire personnel and public safety. F-109.4 Collective bargaining. Nothing in this subsection may be construed to: 1. Preempt any provision in a mutually agreed upon or awarded collective bargaining agreement that provides for substantially the same or a greater right or protection for uniformed Fire Department personnel than that afforded under this Section; or 2. Prohibit the negotiation of any additional right or protection for a uniformed Fire Department member who is subject to any collective bargaining agreement. CHAPTER 2 DEFINITIONS SECTION 201 GENERAL Delete Section 201.3 and replace as follows: F-201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the Administrative Code, the Philadelphia Building Code, the Philadelphia Fuel Gas Code, the Philadelphia Mechanical Code or the Philadelphia Plumbing Code, such terms when used in this code shall have the meanings ascribed to them in those codes. SECTION 202 GENERAL DEFINITIONS Add the definition of Department as follows: DEPARTMENT. For the purpose of this code, the words Department and fire department shall mean the Philadelphia Fire Department. Delete the definition of fire code official and replace as follows: FIRE CODE OFFICIAL. The fire chief or other designated authority charged with the administration and enforcement of the code, or a duly authorized representative. For the purpose of this code, members of the fire department and the Department of Licenses and Inspections are fire code officials. Delete the definition of Recreational Fire and replace as follows: RECREATIONAL FIRE. An outdoor fire burning materials other than rubbish, for pleasure, religious, ceremonial, cooking, warmth or similar purposes, where the fuel being burned is contained in an outdoor fireplace, portable outdoor fireplace, barbeque grill or barbeque pit and has a total fuel area of 3 feet (914 mm) or less in diameter and 2 feet (610 mm) or less in height. Add the definition of regulated facility as follows: REGULATED FACILITY. All buildings, structures and other stationary items which are located on a single site or on a contiguous or adjacent site and which are owned or operated by the same person and which actually manufacture, produce, use, transfer, store, supply or distribute any hazardous material and which are subject to the requirements of Section 303 of SARA Title III. The term includes railroad yards and truck terminals, but does not include individual trucks, rolling stock, water vessels, airplanes or other transportation vehicles. Add the definition of release as follows: RELEASE. Any spilling, leaking, pumping, pouring, emitting, emptying, discharging, injecting, escaping, leaching, dumping or disposing into the environment of a hazardous material, including, but not limited to, the abandonment or discarding of barrels, containers and other receptacles containing a hazardous material. Add the definition of reportable quantity as follows: REPORTABLE QUANTITY. The quantity of a hazardous material stated on the various lists of hazardous substances and extremely hazardous substances as defined in this Section, the release of which has been deemed to constitute a substantial danger to the public health or welfare or environment and is therefore designated as the threshold quantity necessitating reports of releases pursuant to Section 102 of CERCLA and the HazMat Act. Add the definition of social entertainment as follows: SOCIAL ENTERTAINMENT. Provision for dancing by patrons, entertainment by live or recorded music or a disc jockey, a theatrical or other performance act or similar activities. The term shall not include the consumption of food or beverages, listening to a speaker or lecture, watching television programming, watching or participating in athletic events, or other similar activities. Add the definition of special assembly occupancy as follows: SPECIAL ASSEMBLY OCCUPANCY. One of the following if 50 or more people congregate primarily for social entertainment purposes at such location at one or more times during the course of a year: bar, banquet hall, cabaret, discotheque, nightclub, private club, restaurant, tavern and similar places of assembly without primarily fixed seating. CHAPTER 3 GENERAL REQUIREMENTS SECTION 301 GENERAL Delete Section 301.2 and replace as follows: F-301.2 Permits. Permits and approvals shall be required as set forth in Section F-105.6 for the activities or uses regulated by Sections 307, 308 and 315. SECTION 305 IGNITION SOURCES Delete Section 305.1 and replace as follows: F-305.1 Clearance from ignition sources. A clearance of at least 3 feet (914 mm), or greater where required by another Section of this code or the manufacturer's instructions, between ignition sources, such as luminaries, heaters, flame-producing devices and combustible materials, shall be maintained in an approved manner. SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES Add Section F-307.1.2 as follows: F-307.1.2 Appliances or containers. Any appliance or container used for open burning shall be constructed of a non-combustible material that is completely enclosed by solid or mesh material. The maximum openings of the mesh material shall not exceed 1 inch (25.4 mm) measured diagonally. Delete Section 307.2 and replace as follows: F-307.2 Approval required. Written approval shall be obtained from the fire code official in accordance with Section F-105.7.3 prior to kindling a fire for recognized silvicultural or range or wildlife management practices, prevention or control of disease or pests, or a bonfire. Application for such approval shall only be presented by and issued to the owner of the land on which the fire is to be kindled. SECTION 308 OPEN FLAMES Delete Section 308.1.3 and replace as follows: F-308.1.3 Torches for roofing or removing paint. A person utilizing a torch or other flame-producing device for roofing or removing paint from a structure shall provide not less than one portable fire extinguisher complying with Section 906 and with a minimum 4-A rating, two portable fire extinguishers, each with a minimum 2-A rating, or a water hose connected to the water supply on the premises where such burning is done. The person doing the burning shall remain on the premises 1 hour after the torch or flame-producing device is utilized. Roofing work utilizing a torch or hot-air gun shall be in accordance with Section 3317. Delete Section 308.1.4 and replace as follows: F-308.1.4 Open-flame cooking devices. Charcoal burners, barbecue grills and other open-flame cooking devices shall not be operated on balconies or within 10 feet (3048 mm) of combustible construction. Exceptions: 1. One- and two-family dwellings provided that all cooking devices are at least 5 feet from combustible walls, 10 feet from combustible ceilings, and LP gas (such as propane) containers used with cooking devices are at least 5 feet (1524 mm) from any building openings. 2. Where buildings, balconies and decks are protected by an automatic sprinkler system and cooking devices are at least 10 feet from combustible construction and LP gas (such as propane) containers used with cooking devices are at least 5 feet (1524 mm) from building openings. Delete Section 308.1.6, including the exception, and replace as follows: F-308.1.6 Open-flame devices. Torches and other devices, machines or processes liable to start or cause a fire shall not be operated or used in or upon wildfire risk areas or other hazardous areas except by written approval from the fire code official in accordance with Section F-105.7.3. Add Section F-308.1.9 as follows: F-308.1.9 Portable heating and cooking equipment in buildings. Portable heating and cooking equipment that produces a flame is not permitted in a building. Exceptions: 1. Portable heating equipment is permitted in buildings undergoing construction or temporarily without heat with written approval from the fire department and in accordance with Section 3303. 2. Listed and approved portable kerosene heaters are permitted in one- and two-family dwellings when used in accordance with the manufacturer's instructions and Sections 2.1 through 2.4. 2.1 Heaters shall be located at least 3 feet (914 mm) from combustible materials. 2.2 Heaters shall not be left unattended and shall be shut off before sleeping. 2.3 Heaters shall be refueled outdoors with the heater not in operation. 2.4 Fuel containers for refueling heaters shall be stored outdoors in secure location. 3. Small containers of a heating source, such as alcohol or paraffin, used for warming food when in spill proof containers or placed in a chaffing dish holder designed for that purpose. Delete Section 308.2 and replace as follows: F-308.2 Approval required. Written approval shall be obtained from the fire code official in accordance with Section F-105.7.3 prior to engaging in the following activities involving open flame, fire and burning: 1. Use of open flame, fire or burning in connection with Group A or E occupancies. 2. Use or operation of torches and other devices, machines or processes liable to start or cause fire in or upon wildfire risk areas. SECTION 311 VACANT PREMISES Add Section F-311.2.2.1 as follows: F-311.2.2.1 Signage. During the period a sprinkler system is out of service a sign shall be placed at each fire department connection that states: "Sprinkler System: No Automatic Water Supply". SECTION 315 GENERAL STORAGE Delete Section 315.2 and replace as follows: F-315.2 Licenses. A license shall be required as set forth in Section F-105.6.6. CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS SECTION 403 EMERGENCY PREPAREDNESS REQUIREMENTS Add Section F-403.2.2.1 as follows: F-403.2.2.1 Continuous entertainment programs. Places of assembly having continuous entertainment, music or other programs, shall announce the locations of exits at the change of each entertainment set, but no less frequently than every 90 minutes. Add Section F-403.2.5 as follows: F-403.2.5 Convention, trade shows and exhibition events. Conventions, trade shows and exhibition events shall be conducted in accordance with fire safety requirements of the fire department and the Department of Licenses and Inspections. Delete Section 403.11.2 and replace as follows: F-403.11.2 High-rise buildings. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for high-rise buildings. Plans shall be approved by the Fire Department. The fire code official shall inspect high-rise buildings for compliance with this code. The owner, manager or operator of high-rise buildings shall obtain the license required by Section F-105.6.3. SECTION F-408 FAMILY CHILD DAY CARE FACILITIES Add Sections F-408.1 through F-408.5.2 as follows: F-408.1 General. Pursuant to the Pennsylvania Uniform Construction Code Act (UCC), and Section B-429 of the Philadelphia Building Code, child day care facilities are permitted to operate in a one- or two-family dwelling unit (home) provided the facility conforms to this Section. F-408.1.1 Child care facilities within a dwelling unit. A dwelling unit where child day care services are provided for 12 or fewer children shall be classified as an R-3 occupancy and as a Family Child Day Care Facility, provided that it is in accordance with all of the following: 1. The dwelling unit is contained within a one- or two-family dwelling. 2. Child day care services are provided for less than 24 hours. 3. The dwelling unit is used primarily as a private residence. 4. The provision of child day care services is accessory to the principal use of the dwelling unit as a residence. F-408.1.2 License. A license to operate a Family Child Day Care Facility shall be required pursuant to Section F-105.6.2. F-408.2 Fire extinguisher. At least one portable fire extinguisher with a minimum rating of 2-A:10-B:C shall be mounted in the portion of the building used for the Family Child Day Care Facility and in kitchens and other cooking areas used by the Family Child Day Care Facility. F-408.3 Portable heating devices. Portable heating devices that produce an open flame shall not be used in buildings during the operating hours of a Family Child Day Care Facility. F-408.4 Six or fewer children. Family Child Day Care Facilities that are classified as Group R-3 occupancies pursuant to Section B-429.1.1 of the Philadelphia Building Code with six or fewer children shall comply with Sections F-408.4.1 and F-408.4.2. F-408.4.1 Smoke alarms. A single-station smoke alarm shall be installed in each story including basements. The smoke alarms shall be powered by either the building wiring system or 10-year, non-removable batteries, both of which shall be listed by Underwriters Laboratories and shall sound an alarm when activated that is audible to persons in the dwelling unit's indoor child care spaces with all intervening doors closed. Where battery powered smoke alarms are used, the building owner shall keep the proof and date of purchase of the smoke alarms in the unit's fire drill logs. F-408.4.2 Means of egress. The dwelling unit and the accessory Family Child Day Care Facility shall comply with the means of egress requirements for an R-3 occupancy and licensure under 55 Pa. Code Chapter 3290 (relating to Family Child Day Care Facilities). F-408.5 Seven to 12 children. Family Child Day Care Facilities that are classified as Group R-3 occupancies pursuant to Section B-429.1.1 of the Philadelphia Building Code that provide child day care services to more than six but no more than 12 children shall comply with Sections F-408.5.1 through F-408.5.2. F-408.5.1 Smoke alarms. Interconnected, multiple-station smoke alarms shall be installed in each story including basements. The smoke alarms shall be powered by the building wiring system and shall sound an alarm when activated that is audible to persons in the dwelling unit's indoor child care spaces with all intervening doors closed. F-408.5.2 Means of egress. The dwelling unit and the accessory Family Child Day Care Facility shall comply with the means of egress requirements for an R-3 occupancy and licensure under 55 Pa. Code Chapter 3280 (relating to Group Child Day Care Facilities). CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL Delete Section 501.2 and replace as follows: F-501.2 Permits. Construction permits shall be required as set forth in Section F-105.9. SECTION 507 FIRE PROTECTION WATER SUPPLIES Delete Sections 507.5 (Retain Sections 507.5.1 through 507.5.6) and replace as follows: F-507.5 Fire hydrant systems. Fire hydrant systems shall comply with Sections 507.5.1 through F-507.5.8. Delete Section 507.5.1.1 and replace as follows: F-507.5.1.1 Number and location of private fire hydrants. Where private fire hydrants are required by this Chapter, one fire hydrant is required for the first 50,000 square feet (4650 m 2) or fraction thereof of the gross floor area at grade (footprint) of a building, plus one fire hydrant for each additional 50,000 square feet (4650 m 2) or fraction thereof of gross floor area at grade. Where a property has multiple buildings requiring fire hydrants, one fire hydrant is sufficient for that group of buildings provided that each exterior point of a building is within 400 feet (122 m) of a fire hydrant. The exact location of the fire hydrants shall be specified by the fire department after survey of the site or review of building plans to determine the most advantageous locations for fire fighting. F-507.5.1.2 Water main size. Newly installed water mains that supply private fire hydrants shall not be less than 6 inches (152 mm) in diameter. F-507.5.1.3 Flow and pressure requirements. Private fire service mains shall provide a minimum flow of 600 gallons per minute (2271 l/min) at a minimum residual pressure of 20 pounds per square inch (138 kPa). F-507.5.1.4 Type of private fire hydrants. Newly installed private fire hydrants shall be Philadelphia standard fire hydrants as specified by the Philadelphia Water Department. Existing private fire hydrants are acceptable provided the outlets and operating stems are the same as those on a Philadelphia standard fire hydrant. Existing pentagonal (5 sided) operating stems corresponding in dimensions to fire department fire hydrant wrenches are also acceptable. F-507.5.1.5 Color coding of private fire hydrants. To assist the fire department in quickly locating private fire hydrants during a fire emergency and in identifying those connected to non-potable (untreated) water supplies, the fire hydrants shall be color coded consistent with the Water Department's color coding of municipal fire hydrants in accordance with Sections 507.5.1.5.1 and 507.5.1.5.2. F-507.5.1.5.1 Fire hydrants connected to potable water supplies. Private fire hydrants connected to potable water supplies shall be painted orange, with the bonnet (top portion) color coded to identify the diameter of the water main feeding the fire hydrant as follows: 1. Bonnets shall be painted orange for fire hydrants connected to water mains 8 inches (203 mm) or smaller in diameter. 2. Bonnets shall be painted green for fire hydrants connected to water mains 10 inches (254 mm) to 14 inches (356 mm) in diameter. 3. Bonnets shall be painted red for fire hydrants connected to water mains 16 inches (406 mm) or larger in diameter. F-507.5.1.5.2 Fire hydrants connected to non-potable water supplies. Private fire hydrants connected to non-potable water supplies shall be painted entirely red. Add Section F-507.5.7 as follows: F-507.5.7 Fire apparatus access to private fire hydrants. Private fire hydrants shall be located within 3 feet (914 mm) of a hard, all-weather surface, at least 12 feet (3657 mm) wide, capable of supporting the weight of a fire department pumper as determined by the fire department. A clearance of at least 20 feet (6096 mm) on each side of the fire hydrant shall be maintained along the hard, all-weather surface adjoining the fire hydrant. Add Section F-507.5.8 as follows: F-507.5.8 Fire apparatus access to public fire hydrants. A clearance shall be maintained along public streets of 20 feet (6096 mm) on each side of public fire hydrants and vertically to a height of 13 feet, 6 inches (4115 mm). SECTION 508 FIRE COMMAND CENTER Delete Section 508.1 and replace as follows: F-508.1 General. Where required by other Sections of this code and in all buildings classified as high-rise buildings by the Philadelphia Building Code that are constructed, or existing and changing occupancy classification, on or after January 1, 1984, a fire command center for fire department operations shall be provided. Where a fire command center is required to be installed to comply with this code, it shall comply with Section 508.1.1 through 508.1.7. Delete Section 508.1.1 and replace as follows: F-508.1.1 Location and access. The location and accessibility of the fire command center shall be approved by the fire department. Add Section F-508.1.7 as follows: F-508.1.7 Identification of the fire command center. Doors to a fire command center shall be marked "Fire Command Center". SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE Delete Section 510.3 and replace as follows: F-510.3 Permit required. A construction permit for the installation of or modification to emergency responder radio coverage systems and related equipment is required as specified in Section F-105.9.2. Maintenance performed in accordance with this code is not considered a modification and does not require a permit. CHAPTER 6 BUILDING SERVICES AND SYSTEMS [History: Enrolled bill read "buildiing".] SECTION 601 GENERAL Delete Section 601.2 and replace as follows: F-601.2 Permits. Permits shall be obtained for refrigeration systems, battery systems and solar photovoltaic power systems as set forth in Section F-105.9.12 and the Philadelphia Administrative Code. SECTION 603 FUEL-FIRED APPLIANCES Add Section F-603.1.3.1 as follows: F-603.1.3.1 Oil burner operating controls. Oil burners shall have an electrical means to manually stop the flow of oil to the burner for maintenance and during an emergency at the following locations. The device for maintenance work shall be located at the burner. A secondary emergency device shall be readily accessible a safe distance from the burner (immediately outside the room to the heater or at the top of the stairway where a heater is installed in a basement, but not in a room). All devices shall be labeled. Delete Section 603.4 (Retain Sections 603.4.1 through 603.4.2.3.4) and replace as follows: F-603.4 Portable unvented heaters. Portable unvented fuel-fired heating equipment shall be prohibited. Exceptions: 1. Portable heating equipment is permitted in buildings undergoing construction or temporarily without heat with written approval from the fire department and in accordance with Section 3303. 2. Listed and approved portable kerosene heaters are permitted in one- and two-family dwellings when used in accordance with the manufacturer's instructions and Sections 2.1 through 2.4. 2.1. Heaters shall be located at least 3 feet (914 mm) from combustible materials. 2.2. Heaters shall not be left unattended and shall be shut off before sleeping. 2.3. Heaters shall be refueled outdoors with the heater not in operation. 2.4. Fuel containers for refueling heaters shall be stored outdoors in a secure location. SECTION 606 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS Delete Section 606.3 and replace as follows: F-606.3 Emergency signs. An approved pictorial sign of a standardized design, as indicated in Appendix O, shall be posted adjacent to each elevator call station on all floors, instructing occupants to use the exit stairways and not to use the elevators in case of fire. The sign shall read: IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS (OR FIRE STAIRS). Exceptions: 1. The emergency sign shall not be required for elevators that are part of an accessible means of egress complying with Section 1009.4. 2. The emergency sign shall not be required for elevators that are used for occupant self-evacuation in accordance with Section 3008 of the Building Code. Delete Section 606.7 and replace as follows: F-606.7 Elevator keys. Keys for the elevator car doors and fire-fighter service keys shall be kept in an approved location for immediate use by the fire department. Elevator keys for emergency use for door access (shaftway door access) and override of normal operations (Phase I recall and Phase II firefighter use) shall be marked as such and readily available at the fire command center or main lobby desk for use by the fire department and other emergency personnel. In buildings without a fire command center or main lobby desk, the keys shall be stored in a break-glass container at the main entrance. There shall be at least two door access keys and at least 6 override keys available for emergency use. CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 701 GENERAL Add Section F-701.6.1 as follows: F-701.6.1 Periodic inspection of dampers. Where ready access to required fire dampers, smoke dampers and combination fire/smoke dampers is available, such dampers shall be inspected and certified in accordance with Sections F-701.6.1.1 through F-701.6.1.5 where installed in the following locations: 1. Special Assembly Occupancies, including any exit enclosures providing a means of egress from spaces containing such occupancies. 2. Group I-2 occupancies, including any exit enclosures providing a means of egress from spaces containing such occupancies. 3. Vertical ventilation shafts located within high-rise buildings where the shaft has a minimum fire resistance rating of one-hour. In this Section, ready access shall mean that the damper has been provided with a means of access, which is large enough to permit inspection and maintenance of the damper and its operating parts in accordance with the Building Code at the time of construction. Exception: This Section shall not apply to the inspection of dampers that are part of a smoke control system as regulated by Section F-901.6.4.9. F-701.6.1.1 Inspection methods. Inspection and testing shall be performed to ensure the following: 1. Unobstructed access to the damper shall be verified and corrected as required. 2. An operation test of the damper shall verify that the damper closes and that there is no damper interference due to rusted, bent, misaligned or damaged frame or blades, or defective hinges or parts. 3. The damper frame shall not be penetrated by any foreign objects that would affect fire damper operations. 4. The damper shall not be blocked from closure in any way. 5. The fusible link (if applicable) shall be reinstalled after the completion of the operation testing. 6. If the fusible link (if applicable) is damaged or painted, it shall be replaced with a link of the same size, temperature and load rating. F-701.6.1.2 Qualifications of Contractors. Any contractor who conducts periodic inspection of required fire dampers, smoke dampers and combination fire/smoke dampers shall be licensed in one of the following categories in accordance with Chapter 9-1000 of The Philadelphia Code: 1. Master Plumber (9-1003) 2. Contractor (9-1004) 3. Fire Suppression System Contractor (9-1005) 4. Electrical Contractor (9-1006) F-701.6.1.3 Qualifications of Inspectors. Any individual performing periodic inspection of required fire dampers, smoke dampers and combination fire/smoke dampers shall be a Sheet Metal Systems Technician, certified by the Department of Licenses and Inspections pursuant to Chapter 9-3000 of The Philadelphia Code. The Technician shall also hold a certification from the Sheet Metal Industry International Certification Board (ICB) as a Fire Life Safety Level 1 or Level 2 Technician, or a similar certification from an independent personal certification program approved by the Department. F-701.6.1.4 Frequency. Each fire damper, smoke damper and combination fire/smoke damper with ready access shall be inspected upon initial installation and thereafter every four years, except in Group I-2 occupancies where the frequency shall be every six years. F-701.6.1.4.1 Initial inspection. The initial inspection and certification of each fire damper, smoke damper and combination fire/smoke damper, installed prior to the effective date of this Ordinance, and regulated by this Section, shall be completed by January 1, 2020. F-701.6.1.5 Certification reporting. All inspections shall be documented by the Contractor on a certification form established by the fire code official indicating the locations of the fire damper, smoke damper and combination fire/smoke damper inspected, date of inspection, name of inspector and Sheet Metal Technician Certification number of the inspector. The report must be presented by the Contractor to the building owner upon completion and shall be maintained on the property and made available for inspection upon request by the fire code official. The report shall also be submitted to the Department of Licenses and Inspections who may, by regulation, establish a fee to be paid upon submission of the report. F-701.6.1.6 Submission of deficiencies. When deficiencies are not corrected within ninety (90) days, the Contractor performing the required inspections and testing shall submit a list of deficiencies that preclude inspection certification of the dampers, in an approved form to the fire code official. CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 806 NATURAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS Delete Section 806.1.1 and replace as follows: F-806.1.1 Restricted occupancies. Natural cut trees shall be prohibited in all buildings. Exception: One- and two-family dwellings. CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS SECTION 901 GENERAL Delete Section 901.3 and replace as follows: F-901.3 Permits. Construction permits shall be required as set forth in Section F-105.9. Add Sections F-901.6.4 through F-901.6.4.9.2 as follows: F-901.6.4 Periodic testing. The testing of fire protection systems shall be in accordance with Sections 901.6 and F-901.6.4 through F-901.6.4.8.1. Annually the owner of each building that contains fire protection systems shall have such systems certified as operating properly by a person certified or licensed by the Department of Licenses and Inspections to provide such certifications in accordance with this Section. Certification forms shall be maintained on the property and made available for inspection upon the request of a fire code official. The certification form shall be submitted to the Department of Licenses and Inspections who may, by regulation, establish a fee to be paid upon submission of the form. Exceptions: 1. Smoke alarms in residential occupancies provided that they are tested by the building owner or tenant in accordance with the manufacturer's instructions. 2. Automatic sprinkler systems in one- and two-family dwellings. F-901.6.4.1 Submission of deficiencies. When deficiencies of a fire protection system are not corrected within the annual certification time frame, the contractor performing the annual certification shall submit a list of deficiencies that precludes certification of the system, in approved form to the Department of Licenses and Inspections. F-901.6.4.2 Submission of certifications. The Department of Licenses and Inspections is authorized to require that certification forms be submitted to the Department electronically by the company that performed the certification. F-901.6.4.3 Partial certification. When a fire suppression system is repaired, altered or extended between periodic testing dates, the modified portion of the system is required to be certified upon a return to service. When the entire system is certified upon return to service at the owner's discretion, the date of certification will become the new periodic test date. F-901.6.4.4 Annual certification of fire suppression system during period of retrofit or new installation. During the period of sprinkler and/or standpipe retrofit or new installation, the normal certification procedures shall continue to apply to existing systems and to completed portions of new installations. F-901.6.4.5 Consistency of required test dates. To ensure consistency of required tests for fire alarm, sprinkler and standpipe systems, where the maximum frequency exceeds one year (multi-year tests) tests shall be conducted in accordance with the dates indicated in Sections F-901.6.4.5.1 through F-901.6.4.5.4. Where a test is performed during the 12 months preceding the next required multi-year test, the next required test need not be performed. F-901.6.4.5.1 Maximum 3-year interval. Where the code or referenced standard requires inspection, testing and/or maintenance at a maximum 3-year interval, such inspection, testing and/or maintenance shall be required in 2017 and every 3 years thereafter, except those water-based systems protecting areas that are constantly maintained below a freezing temperature. F-901.6.4.5.2 Maximum 5-year interval. Where the code or referenced standard requires inspection, testing and/or maintenance at a maximum 5-year interval, such inspection, testing and/or maintenance shall be required in 2015 and every 5 years thereafter. F-901.6.4.5.3 Maximum 10 year test. Where the code or referenced standard requires inspection, testing and/or maintenance at a maximum 10-year interval, such inspection, testing and/or maintenance shall be required in 2015 and every 10 years thereafter. F-901.6.4.5.4 Alternate year smoke detector sensitivity testing. Alternate year smoke detector sensitivity testing shall begin in the odd-numbered years. When the one-year sensitivity test occurs in an even- numbered year, the next sensitivity test is not due until the second subsequent odd-numbered year. Results of sensitivity tests shall be listed on the annual inspection and certification form. F-901.6.4.6 Annual audibility testing in Groups I-1, R-1, R-2 and R-4. In Group I-1, R-1, R-2 and R-4 occupancies, the annual certification of the fire alarm systems shall contain the results of audibility tests performed in accordance with NFPA 72 in the sleeping rooms of a representative sample of units contained within the building. The specific units tested and the audibility readings taken shall be entered on the annual certification form. The sample shall include, as a minimum, areas in Numbers 1 through 4 as follows: 1. One of each type of unit contained in the building. 2. The unit or units most remote from the audible alarm notification appliances. 3. Any unit or units with sleeping rooms that are separated from the corridor by building cores, such as elevator cores, stairways, etc. 4. One unit per floor. F-901.6.4.7 Audibility of fire alarm systems. The audibility of fire alarm system notification appliances in existing buildings shall be in accordance with the Numbers 1, 2 or 3 as applicable. 1. Occupancies with an existing, previously approved fire alarm system installed prior to March 1, 1991, are permitted to have audible alarm notification appliances that produce a sound pressure level above the normal ambient sound level of at least 15 decibels per the A scale of a sound pressure level meter (dBA) throughout the building. 2. Fire alarm systems installed between March 1, 1991, and December 31, 2009, are permitted to have audible alarm notification appliances that produce a sound pressure level of at least 15 dBA above the normal sound level, but not less than 60 dBA throughout the building, and not less than 70 dBA throughout Group I-1 and R occupancies. 3. Fire alarm systems installed after December 31, 2009, shall have audible alarm notification appliances that produce a sound pressure level of at least 15 dBA above the normal sound level, but not less than 60 dBA throughout the building, and not less than 75 dBA throughout Group I-1 and R occupancies. F-901.6.4.8 Testing and maintenance of smoke alarms. Smoke alarms, both battery powered and hard wired, shall be tested, inspected and maintained in accordance with manufacturer's instructions. They shall be tested weekly. F-901.6.4.8.1 Responsibility. Occupants shall be responsible for the testing and battery replacement of battery-powered smoke alarms within their dwelling units. Owners shall be responsible for the replacement of non-operating smoke alarms within three days of written notice. F-901.6.4.9 Testing of smoke control systems. The periodic inspection and testing of smoke control systems shall follow the operational testing program established by the system design professional and initiated immediately after the smoke control system passed the acceptance tests required by the Building Code. If such a testing program does not exist, the contractor is authorized to develop one in accordance with generally accepted engineering practice and, where possible, based upon published standards for the existing system. Testing of smoke control systems shall be performed by a Sheet Metal Systems Technician, certified by the Department of Licenses and Inspections pursuant to Chapter 9-3000 of The Philadelphia Code and employed by a contractor licensed in one of the following categories in accordance with Chapter 9-1000 of The Philadelphia Code: 1. Master Plumber (9-1003) 2. Contractor (9-1004) 3. Fire Suppression System Contractor (9-1005) 4. Electrical Contractor (9-1006) F-901.6.4.9.1 Additional certification required. The Technician performing periodic testing of smoke control systems shall also hold a mechanical system testing certification from the Sheet Metal Industry International Certification Board (ICB) as a Fire Life Safety Level 2 Technician; a similar certification from an independent personal certification program approved by the Department; or certification as an air balancer from one of the following: 1. Associated Air Balance Council (AABC); 2. Testing & Balancing Bureau (TABB); 3. National Environmental Balancing Bureau (NEBB); or 4. National Balancing Council (NBC). F-901.6.4.9.2 Initial inspection and testing. The initial inspection and testing of each smoke control system, installed prior to the effective date of this Ordinance, and regulated by this Section, shall be completed by January 1, 2020. Delete Section 901.7 (Retain Sections 901.7.1 through 901.7.6) and replace as follows: F-901.7 Systems out of service. Where a required fire protection system is out of service, the fire department shall be notified immediately in accordance with, and under the conditions specified in Section F-106.5.1. Out of service fire protection systems in vacant buildings shall be subject to the requirements of Section 311. Where required by the fire code official, the building shall either be evacuated, or an approved fire watch shall be provided for all occupants left unprotected by the shutdown until the fire protection system has been returned to service. Where utilized, fire watches shall be provided with at least one approved means for notification of the fire department and their only duty shall be to perform constant patrols of the protected premises and keep watch for fires. In the event that the fire watch observes smoke or fire, the fire department shall be notified immediately. The fire department shall be notified upon the return of the system to service. The duties of the fire watch are as follows: 1. An adequate number of fire watch personnel shall be on duty to ensure that all areas of a property are inspected every 30 minutes. In multi-story buildings there shall be at least one fire watch for every five floors. 2. At the beginning of the fire watch, fire watch personnel shall notify occupants of the temporary means by which they will be notified of the need to evacuate. A compressed air horn or other loud sounding device shall be used to alert occupants to evacuate the building in the event of smoke or fire. 3. Fire watch personnel shall be trained in their duties in accordance with Section 406. 4. A log shall be maintained of all fire watch activities. Add Sections F-901.11 through F-901.11.2 as follows: F-901.11 Monitoring of fire protection equipment. Fire alarm systems and automatic fire extinguishing systems in existing building and structures shall be monitored in accordance with this Section. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved supervising station or, when approved by the fire department, shall sound an audible signal at a constantly attended location. F-901.11.1 Monitoring of fire alarm systems. In buildings constructed on or after January 1, 2004, and in buildings constructed prior to January 1, 2004, containing a Group I or H occupancy or high-rise buildings, the fire alarm system shall be monitored in accordance with Section F-901.11. F-901.11.2 Monitoring of fire extinguishing systems. Automatic fire extinguishing systems installed on or after March 1, 1991, and automatic fire extinguishing systems installed in Group H and I occupancies and high-rise buildings prior to March 1, 1991, shall be monitored in accordance with Section F-901.11. SECTION 912 FIRE DEPARTMENT CONNECTIONS Delete Section 912.3 and replace as follows: F-912.3 Fire hose threads. Fire hose threads used in connection with sprinkler and standpipe systems shall be approved and shall be compatible with fire department hose threads. Fire department connections shall have a minimum of two 2-1/2 inch (64 mm) internal threaded swivel fittings having National Hose standard threads with caps. Exceptions: 1. Manual dry standpipe systems with 6-inch (152 mm) or larger risers shall have three 2-1/2 inch (64 mm) internal threaded swivel fittings having National Hose standard threads with caps. 2. Limited area sprinkler systems in other than basements and stories without openings, are not required to have a fire department connection. 3. National Fire Protection Association (NFPA) Standard 13R systems shall have a fire department connection with one 2-1/2 inch (64 mm) internal threaded swivel fitting having National Hose standard threads with a cap, and NFPA 13D systems are not required to have a fire department connection. Delete Section 912.5 and replace as follows: F-912.5 Fire department connection signs. A durable, weather resistant sign shall be mounted at each fire department connection indicating the type of system (sprinkler, standpipe, combined sprinkler and standpipe or test connection). Wording on signs indicating the type of system shall be a minimum 1-inch (25 mm) high. Other information shall be a minimum 1/2-inch (13 mm) high. Where the fire department connection does not serve the entire building, a sign shall be provided indicating the portions of the building served. SECTION 916 GAS DETECTION SYSTEMS Delete Section 916.2 and replace as follows: F-916.2 Permits. Permits shall be required as set forth in the Philadelphia Administrative Code. CHAPTER 11 CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS [History: Enrolled bill read "existng".] SECTION 1101 GENERAL Delete Section 1101.3 and replace as follows: F-1101.3 Permits. Permits shall be required as set forth in Section F-105 and the Philadelphia Administrative Code. SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS Delete Section 1103.1.1 and replace as follows: F-1103.1.1 Historic buildings. Facilities designated as historic buildings may be required by the fire code official to develop a fire protection plan in accordance with NFPA 914. Where required such fire protection plans shall comply with the maintenance and availability provisions in Sections 404.3 and 404.4. Add Section F-1103.1.2 as follows: F-1103.1.2 Fire resistance rating of existing construction. The following existing construction materials shall be permitted where a 1-hour fire resistance rating is required by this code: 1. Wood or metal studding with 5/8-inch fire rated (Type X) gypsum wall board on each side. 2. Wood lathe and plaster. 3. Six-inch or greater hollow or solid CMU (cinder block). 4. Construction having a 1-hour listing by Underwriters Laboratories or other approved testing agency. Delete Section 1103.2 and replace as follows: F-1103.2 Emergency responder radio coverage in existing buildings. Existing buildings, other than Group R-3, that do not have approved radio coverage for emergency responders in the building based on existing coverage levels of the public safety communication systems shall be equipped with an approved and operational wired communication system. Exception: Buildings constructed under a Building Code in effect prior to January 1, 2010. Delete Section 1103.3 (Retain Sections 1103.3.1 and 1103.3.2) and replace as follows: F-1103.3 Existing elevators. In other than Group R-3, existing elevators, escalators and moving walks shall comply with the requirements of Sections 1103.3.1 through F-1103.3.4. Add Section F-1103.3.3 as follows: F-1103.3.3 Elevator emergency signs. Elevator emergency signs shall be in accordance with Section 606.3. Add Section F-1103.3.4 as follows: F-1103.3.4 Elevator keys. Keys for the elevator car doors and fire-fighter service keys shall be kept in an approved location for immediate use by the fire department. Elevator keys for emergency use for door access (shaftway door access) and override of normal operations (Phase I recall and Phase II firefighter use) shall be marked as such and readily available at the fire command center or main lobby desk for use by the fire department and other emergency personnel. In buildings without a fire command center or main lobby desk, the keys shall be stored in a break-glass container at the main entrance. There shall be at least two door access keys and at least 6 override keys available for emergency use. Delete Section 1103.4.9 and replace as follows: F-1103.4.9 Waste and linen chutes. Existing waste and linen chutes shall comply with Sections F-1103.4.9.1 through F-1103.4.9.5 in the following occupancies: 1. Group I-2 occupancies, and 2. High-rise buildings of Group R-2 occupancy. F-1103.4.9.1 Enclosure. Chutes shall be enclosed with 1-hour fire-resistance-rated construction. Opening protectives shall be in accordance with Section 716 of the International Building Code and have a fire protection rating of not less than 1 hour. F-1103.4.9.2 Chute intakes. Chute intakes shall comply with Section F-1103.4.9.2.1 or F-1103.4.9.2.2. F-1103.4.9.2.1 Chute intake direct from corridor. Where intake to chutes is direct from a corridor, the intake opening shall be equipped with a chute-intake door in accordance with Section 716 of the International Building Code and having a fire protection rating of not less than 1 hour. F-1103.4.9.2.2 Chute intake via a chute-intake room. Where the intake to chutes is accessed through a chute-intake room, the room shall be enclosed with 1-hour fire-resistance-rated construction. Opening protectives for the intake room shall be in accordance with Section 716 of the International Building Code and have a fire protection rating of not less than 3/4 hour. Opening protectives for the chute enclosure shall be in accordance with Section F-1103.4.9.1. In buildings where an automatic fire extinguishing system is not required throughout the building and where the chute-intake room is not used for the temporary or permanent storage of combustible materials, the automatic fire extinguishing system is not required in the chute-intake room. F-1103.4.9.3 Automatic sprinkler system. Chutes shall be equipped with an approved automatic sprinkler system in accordance with Section 903.2.11.2. F-1103.4.9.4 Chute discharge rooms. Chutes shall terminate in a dedicated chute discharge room. Such rooms shall be separated from the remainder of the building by not less than 1-hour fire-resistance-rated construction. Opening protectives shall be in accordance with Section 716 of the International Building Code and have a fire protection rating of not less than 1 hour. F-1103.4.9.5 Chute discharge protection. Chute discharges shall be equipped with a self-closing or automatic-closing opening protective in accordance with Section 716 of the International Building Code and having a fire protection rating of not less than 1 hour. Delete Section 1103.5 (Only 1103.5) and replace as follows: F-1103.5 Sprinkler systems. An automatic sprinkler system shall be provided in existing buildings in accordance with Sections 1103.5.1 through F-1103.5.8.2. Delete Sections 1103.5.2 and 1103.5.3 and replace as follows: F-1103.5.2 Group I-2. An automatic sprinkler system shall be provided throughout existing Group I-2 occupancies. F-1103.5.3 Group I-4 child care facilities. An automatic sprinkler system shall be installed throughout existing Group I-4 child care facilities. Exception: Group I-4 child care facilities legally in existence prior to January 1, 1984, where all children less than 2-1/2 years of age are kept on the level of exit discharge. Add Sections F-1103.5.5 through F-1103.5.8.2 as follows: F-1103.5.5 High-hazard occupancies. An automatic sprinkler system shall be installed throughout existing high-hazard occupancies. F-1103.5.6 High-rise buildings. An automatic sprinkler system shall be installed throughout existing high-rise buildings. Exception: Portions of high-rise buildings occupied by Group R-2 occupancies without a change in occupancy since December 18, 1991. F-1103.5.6.1 High-rise Group R-2 occupancies. An automatic sprinkler system shall be installed in the following areas of existing Group R-2 occupancies in the portions of the high-rise building to which the requirements of Section F-1103.5.6 do not apply: 1. Basements in accordance with Section F-1103.5.7. 2. Rooms used for storage where the floor area exceeds 120 square feet (11 m2). 3. Trash and incinerator chutes and rooms in accordance with F-1103.4.9. F-1103.5.7 Basements without openings. Basements in existing buildings exceeding 2500 square feet (232 m 2) without openings shall be equipped with an automatic sprinkler system. Exceptions: 1. Basements containing no occupancy or storage, excluding permanently installed building service equipment, but not excluding oil cooled electrical equipment. 2. Group R-3 and Group U occupancies. 3. Basements with openings meeting one of the following conditions: 3.1. Doorway openings below grade that lead directly to ground level by an exterior stairway or outside ramp. The door openings shall be located in each 50 linear feet (15 240 mm) or fraction thereof, of exterior wall in the story on at least one side. The required openings shall be distributed such that the linear distance between adjacent openings does not exceed 50 feet (15 240 mm), and all portions of the basement are located within 75 feet (22 860 mm) of a door opening. 3.2. Openings entirely above the adjoining ground level totaling at least 20 square feet (1.86 m2) in each 50 linear feet (15 240 mm), or fraction thereof, of the exterior wall in the story on at least one side. The required openings shall be distributed such that the lineal distance between adjacent openings does not exceed 50 feet (15 240 mm) and all portions of the basement are located within 75 feet (22 860 mm) of an opening. The openings shall have a minimum dimension of not less than 30 inches (762 mm). F-1103.5.7.1 Accessible basement openings. Basement openings shall be accessible to the fire department from the exterior and shall not be obstructed in a manner that will impede fire fighting or rescue operations from the exterior. Materials permitted to be used to cover openings that will not impede fire department fire fighting and rescue are as follows: 1. Doorway openings with doors of metal or wood. 2. Doorway or other openings covered by any of the following materials: 2.1. Wood not exceeding 3/4 inches (1905 mm) in thickness. 2.2. Glass, Plexiglas, fiberglass or plastic not exceeding 1/4 inches (6 mm) in thickness. 2.3. Metal sheeting not exceeding 1/8 inches (3 mm) in thickness. F-1103.5.8 Buildings 45 feet or more in height. An automatic sprinkler system shall be installed in the following areas of existing buildings that have one or more occupied floors located 45 feet (13 716 mm) or more above the lowest level of fire department vehicle access: 1. Basements. 2. The level of exit discharge. Exceptions: 1. Open parking structures. 2. Occupancies in Group F-2. 3. Occupancies in Group R-2. 4. Buildings where all exterior walls have a fire separation distance of 5 feet (1524 mm) or greater. F-1103.5.8.1 Retrofit of buildings. Buildings required by Section F-1103.5.8 to have automatic sprinkler systems installed shall complete the required installation by December 31, 2021. F-1103.5.8.1.1 Required compliance documents. The owner of every building of 5 stories or more in height shall submit to the Department of Licenses and Inspections for approval one of the following by July 1, 2019: 1. A written description of the methods and schedule for compliance with this Section. 2. A site plan prepared by a registered design professional indicating that the fire separation distance of all exterior walls of the building are 5 feet (1524 mm) or greater and therefore the building is not subject to Section F-1103.5.8. 3. An elevation plan prepared by a registered design professional indicating that the existing building does not have one or more occupied floors located 45 feet (13 716 mm) or more above the lowest level of fire department vehicle access. 4. A statement sealed by a registered design professional indicating that the existing building meets an exception for occupancy and therefore the building is not subject to Section F-1103.5.8. 5. Proof that automatic sprinklers were previously installed in the areas required by Section F-1103.5.8 and have been certified pursuant to Section 901. F-1103.5.8.2 Retrofit schedule. Proof of compliance with the automatic sprinkler system installation requirements of this Section shall be submitted to the Department of Licenses and Inspections in the form of a certification pursuant to Section 901. The required certification shall be submitted prior to January 1, 2022. Delete Sections 1103.6 and 1103.6.1 (Retain Section 1103.6.2) and replace as follows: F-1103.6 Standpipes systems. Standpipes systems in existing buildings shall be in accordance with Section F-1103.6. Where standpipes in an existing building exceed the requirements of this Section, as a result of installation requirements by the current or a previous edition of the Philadelphia Building Code, the level of standpipe protection shall not be reduced, except as permitted by Section F-1103.6.3. F-1103.6.1 Class I standpipes. Class I standpipes shall be installed in existing buildings with occupied floors located more than 50 feet (15 240 mm) above or below the lowest level of fire department vehicle access. The standpipes shall have hose connections in each required exit stairway (stair tower, or vestibule where egress width requirements are not violated). Fire department connections shall be in accordance with Section 912. These requirements shall also apply to buildings that were granted variances prior to January 1, 2004, to omit standpipes from the required exit stairways or to have manual dry standpipes. F-1103.6.1.1 Installation requirements. Class I standpipes required to be installed to comply with this Section shall be installed in accordance with Section 905. Class I manual dry standpipes are not permitted, except in open parking garages or by variance granted on or after January 1, 2004. The following are exceptions to the 100 pounds per square inch pressure requirement of NFPA 14 at the most remote hose connection. The exceptions do not apply to the flow requirements. Exceptions: 1. In existing buildings having the highest occupied floors located not more than 75 feet (22 860 mm) above the lowest level of fire department vehicle access, Class I standpipe systems are permitted to be manual wet systems. 2. Standpipe systems installed prior to January 1, 1995, that provide a residual pressure of 65 psi (448 kPa) or greater at the most remote hose connection are exempt from the requirement to provide a residual pressure of 100 psi (690 kPa) at the most remote hose connection. 3. Standpipe systems with a residual pressure of less than 100 psi (690 kPa) at the most remote hose connection are permitted provided that the pressure is sufficient to fill the system and the building is in accordance with Conditions 3.1 through 3.3. 3.1. The building existed prior to January 1, 2004. 3.2. The building is equipped throughout with an automatic fire extinguishing system. 3.3. The floor level of the highest floor is not more than 150 feet (45 720 mm) above the lowest level of fire department vehicle access. F-1103.6.1.2 Standpipe hose connection location. Existing Class I standpipe hose connections within required exit stairways (stair tower or vestibule) are permitted to be located on the floor level landing or alternate floor level landing. Existing hose connections outside of exit stairways shall be relocated to within the exit stairway. F-1103.6.1.3 Orientation of hose connections. Class I standpipe hose connections shall have a minimum clearance of 8 inches (2032 mm) measured from the center of the hose connection in at least one plane to permit the fire department the option of attaching a wye fitting to use two 1-1/2 inch (38 mm) hoses in lieu of one 2-1/2 inch (63 mm) hose. Add Section F-1103.6.3 as follows: F-1103.6.3 Class II standpipe systems. Existing Class II standpipes (also known as occupant use standpipes) shall be maintained. Removal of the hose or the entire system shall be permitted in accordance with the following: F-1103.6.3.1 Removal of Class II hose. Removal of hose from a Class II or Class III standpipe system is permitted in buildings equipped with a manual wet or automatic or semi-automatic dry Class I standpipe system or the building is not required to have a Class I system based on Section F-1103.6.1. F-1103.6.3.2 Removal of Class II system. Removal of a Class II standpipe system is permitted in buildings equipped with a manual wet or automatic or semi-automatic dry Class I standpipe system or the building is not required to have a Class I standpipe system based on Section F-1103.6.1 and not required to have a Class II standpipe system in the locations where they exist based on the current Philadelphia Building Code. Delete Section 1103.7 (Retain Sections 1103.7.1 through 1103.7.6) and replace as follows: F-1103.7 Fire alarm systems in existing buildings. Fire alarm systems shall be installed in existing buildings and structures in accordance with Sections 1103.7.1 through 1103.7.6 and Sections F-1103.7.7 through F-1103.7.11. Where an existing building or structure does not have the fire alarm system required by this Section, a fire alarm system shall be installed in accordance with the appropriate subsection of Section 907. Add Sections F-1103.7.7 through F-1103.7.11 as follows: F-1103.7.7 Group A occupancies. A manual fire alarm system shall be installed throughout existing Group A-1, A-2 and A-3 occupancies with an occupant load of 300 or more and in all Special Assembly Occupancies. In Special Assembly Occupancies a shut-off (shunt trip) device shall be provided to shut off electricity to circuits controlling audio equipment in the facility upon activation of the fire alarm system or automatic sprinkler system. F-1103.7.8 Group I-4. An automatic and manual fire alarm system shall be installed throughout existing Group I-4 occupancies. F-1103.7.9 Group R-1, R-2 and R-3 congregate living facilities. Existing Group R-l and R-2 congregate living facilities shall have hard-wired, interconnected smoke alarms installed in accordance with Section F-1103.8. (Group R-l congregate living is more than 10 residents and Group R-2 congregate living is more than 16 residents. See Chapter 2 under Occupancy Classifications for the complete definition of Group R-1 and R-2 congregate living facilities). Existing Group R-3 congregate living facilities shall have hard-wired, interconnected smoke alarms installed in accordance with F-1103.7.9.1. F-1103.7.9.1 Hard-wired and interconnected smoke alarms in existing Group R-3 congregate living facilities. In addition to the requirements of Section F-1103.8, hard-wired, interconnected smoke alarms complying with UL 217 shall be installed in accordance with Sections F-1103.7.9.1.1 through F-1103.7.9.1.3 and NFPA 72 on each floor, including basements, of existing Group R-3 congregate living facilities. Exceptions: 1. Buildings equipped with an automatic sprinkler system. 2. Buildings equipped with hard-wired smoke alarms installed in compliance with the Building Code. F-1103.7.9.1.1 Interconnection. The smoke alarms required by this Section F-1103.7.9 shall be interconnected in such a manner that the activation of one alarm will activate all of the hard-wired alarms in the facility. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. F-1103.7.9.1.2 Power source. The smoke alarms required by this Section F-1103.7.9 shall receive their primary power from the building wiring, provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection. F-1103.7.9.1.3 Retrofit of R-3 congregate living facilities. The smoke alarms required by this Section F-1103.7.9.1 shall be installed prior to December 31, 2019. Electrical permits for such installations shall be secured prior to July 1, 2019. F-1103.7.10 Group R-4. Smoke alarms shall be installed in existing Group R-4 residential care/assisted living facilities (6 to 16 residents) in accordance with Section 1103.8. F-1103.7.11 Mixed residential and nonresidential use. Where a nonresidential occupancy is located below a residential occupancy, a manual and automatic (smoke detection) fire alarm system shall be installed with smoke detectors installed throughout the nonresidential occupancy, manual fire alarm boxes installed at the exits in the nonresidential areas and alarm notification appliances installed throughout the building. Smoke alarms shall be installed in the dwelling units of the residential portions of the building in accordance with Section 1103.8. Exception: The fire alarm system is not required where an automatic sprinkler system is installed throughout the non-residential portions of the building. Delete Sections 1103.8 through 1103.8.3 and replace as follows: F-1103.8 Single-and multiple-station smoke alarms. Single- and multiple-station (single-station wired together to enable all to sound an alarm when one activates) smoke alarms shall be installed in existing Group R occupancies in accordance with Sections F-1103.8.1 through F-1103.8.3. F-1103.8.1 Location of smoke alarms. Existing Group R occupancies and dwellings shall be provided with single-station smoke alarms. Where installation is required to meet the requirements of this Section the smoke alarms shall be installed in accordance with Section 907.2.10, except as permitted in this Section. Exceptions: 1. Smoke alarms are not required in sleeping rooms in existing Group R-2 occupancies in high-rise buildings equipped throughout with an automatic fire extinguishing system. 2. Smoke alarms are not required in sleeping rooms in Group R-2 or R-3 occupancies in buildings built prior to January 1, 1988, and not classified as high-rise. 3. Where a smoke alarm installed in the immediate vicinity of bedrooms would result in its installation within 3 feet (914 mm) of a door to a bathroom or kitchen, installation beyond the immediate vicinity is permitted, provided that it does not exceed 15 feet (4572 mm) from all bedroom doors. F-1103.8.2 Interconnection of smoke alarms. Where more than one smoke alarm is required to be installed within an individual dwelling or sleeping unit, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Exceptions: 1. Interconnection is not required in buildings built prior to January 1, 1988, that are not undergoing alterations, repairs or construction of any kind. 2. Smoke alarms in existing areas of buildings built prior to January 1, 1988, are not required to be interconnected where repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for interconnection without the removal of interior finishes. 3. Pursuant to the PA Uniform Construction Code, interconnected smoke alarms are not required in one-family and two-family dwellings constructed prior to January 1, 1988 undergoing alterations, repairs or additions. Non-interconnected battery-operated smoke alarms shall be installed in these dwellings. This exception does not apply to multiple single-family dwellings (townhouses). F-1103.8.3 Power source for smoke alarms. Single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection. Exceptions: 1. Smoke alarms are permitted to be solely battery powered with 10-year non-removable (sealed) batteries in existing one- and two-family dwellings built prior to January 1, 1988, where no construction is taking place. 2. Smoke alarms are permitted to be solely battery powered with 10-year non-removable (sealed) batteries in one- and two-family dwellings that are not served from a commercial power source. 3. Smoke alarms are permitted to be solely battery powered with 10-year non-removal (sealed) batteries in existing one- and two-family dwellings built prior to January 1, 1988, undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for building wiring without the removal of interior finishes. Pursuant to the PA Uniform Construction Code, smoke alarms are permitted to be solely battery powered with 10-year non-removal (sealed) batteries in existing detached and semi-detached single-family dwellings constructed prior to January 1, 1988 undergoing alterations, repairs or additions. Add Section F-1103.8.4 as follows: F-1103.8.4 Verification of smoke alarms upon sale of building. Upon the sale of a building containing a Group R-3 occupancy, the seller shall certify in writing to the buyer that smoke alarms required by Section F-1103.8 are installed and in proper operating condition. Delete Section 1103.9 and replace as follows: F-1103.9 Carbon monoxide alarms. Carbon monoxide alarms shall be installed in existing dwelling units or sleeping units in accordance with Sections F-1103.9.1 through F-1103.9.3 where any of the conditions in Sections 915.1.2 through 915.1.6 exist. A carbon monoxide detection system installed in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. Exception: Carbon monoxide alarms are not required in dwelling units and sleeping units of I-1, I-2, I-4, R-1 and R-2 occupancies constructed before April 1, 2019. F-1103.9.1 Locations. Carbon monoxide alarms shall be installed in accordance with Section 915.2. Where the alarm is a combination smoke and carbon monoxide alarm, it shall be located in accordance with the installation instructions for the smoke alarm. Exception: Carbon monoxide alarms installed prior to January 1, 2010, are permitted to be installed not more than 15 feet (4572 mm) from the entrance to each bedroom or each bed in sleeping areas where there is no enclosed bedroom. F-1103.9.2 Power source. Carbon monoxide alarms shall have a power source in accordance with Section 915.4.1. Exception: Carbon monoxide alarms installed in existing Group R-3 and Group R-4 occupancies constructed prior to January 1, 2010, are permitted to be battery powered or electrical plug-in type. Such alarms are not required to be interconnected. F-1103.9.3 Verification of carbon monoxide alarms/systems upon sale of building. Upon the sale of a building containing Group R-3 occupancy, the seller shall certify to the buyer that the carbon monoxide devices required by Section F-1103.9 or Section 915 are installed and in proper operating condition. SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS Delete Section 1104.16 and replace as follows: F-1104.16 Fire escape stairways. Fire escape stairways and associated fire escape balconies shall comply with Sections 1104.16.1 through 1104.16.7. Delete Section 1104.16.5.1 and replace as follows: F-1104.16.5.1 Examination and certification. Fire escape stairways and balconies shall be examined for structural adequacy and safety and certified in accordance with Section 1104.16.5 and Sections F-1104.16.5.1.1 through F-1104.16.5.1.10. F-1104.16.5.1.1 Definitions. The following definitions shall apply to this Section F-1104.16: FIRE ESCAPE. A system of metal landings, balconies, stairs or ladders attached to a building that are not classified as an exterior stairway and are intended or designed to aid in egress from a building in an emergency. FIRE ESCAPE BALCONY. A balcony that projects from the building face and is intended for use in conjunction with a fire escape, an exit stair or an area of refuge. FIRE ESCAPE INSPECTION BUSINESS. A business entity that uses a Professional to perform inspections of fire escapes and fire escape balconies. PROFESSIONAL. A professional engineer, licensed in the Commonwealth of Pennsylvania and experienced in the practice of structural engineering. SAFE. A condition of a fire escape or a fire escape balcony that is neither an Unsafe condition nor Safe with a Repair and Maintenance Program. SAFE WITH A REPAIR AND MAINTENANCE PROGRAM. A condition of a fire escape or a fire escape balcony that is not determined to be Unsafe, at the time of inspection, but that requires maintenance or repair within a time period designated by a Professional in order to prevent further deterioration into an unsafe condition. UNSAFE. A condition of any part of a fire escape or fire escape balcony that is dangerous to persons or property and requires prompt remedial action. F-1104.16.5.1.2 Inspection required. The owner of a building with a fire escape or fire escape balcony shall be responsible for retaining a Professional to conduct periodic inspections of the fire escape or fire escape balcony for structural adequacy and safety and to file a report on such inspection as required by this Section. F-1104.16.5.1.3 Initial inspection. The initial inspection required by this Section shall be conducted, and the required report shall be filed, on or before July 1, 2017. If the construction of the fire escape or fire escape balcony was completed after July 1, 2007, the first inspection shall be conducted within ten years after construction of the fire escape was completed. F-1104.16.5.1.4 Extensions. Where fire escapes and fire escape balconies have undergone a restoration within one year prior to July 1, 2017, the owner may apply to the fire code official for an extension of the required initial inspection. With the application for extension, the owner shall submit such other information determined by the fire code official to be necessary to evaluate the extension request. The fire code official shall grant an extension if he or she determines that the restoration obviates the need for the initial inspection until a date established by the fire code official. F-1104.16.5.1.5 Subsequent inspections. Following the initial inspection, and every inspection thereafter, a fire escape and fire escape balcony shall be re-inspected, and the required report shall be filed within five years of the filing of the report concerning the previous inspection. F-1104.16.5.1.6 Timing of report in relation to inspection. All reports shall be filed within three months of the inspection that is the subject of the report. F-1104.16.5.1.7 Inspection procedures. 1. Before conducting an inspection, the Professional shall review previous reports, inspections, and evidence of repairs made in the five (5) year period prior to the inspection, including confirmation that all areas previously determined to require repair (as noted in any previous report) have been addressed. 2. The inspection shall be conducted by or under the supervision of the Professional. 3. The Professional shall employ the appropriate Professional standard of care in order to detect structural defects, rust, corrosion or any other condition affecting the structural integrity of the fire escape and fire escape balconies. If a distressed condition is identified, the Professional shall order any other inspections or tests that may be required to determine the significance and cause of the distress as well as measures appropriate to remediate the distress. 4. During the course of the inspection, photographs shall be taken or sketches made of the fire escape and fire escape balconies, including documentation of the location of all conditions that are Unsafe or Safe With a Repair and Maintenance Program. 5. To be considered Safe or Safe With a Repair and Maintenance Program, the fire escape and fire escape balconies shall be capable of meeting or exceeding the load requirements of Section 1104.16.5. This load requirement can be met by either an engineering analysis by the Professional or by conducting a load test. Any load test shall be witnessed by the Professional and shall comply with the applicable provisions of Chapter 17 of the Philadelphia Building Code. 6. Upon discovery of any Unsafe condition, the Professional shall immediately notify the owner of the building by electronic mail or fax and shall within twelve (12) hours of such discovery, notify the fire code official, in writing, and in an electronic format determined by the fire code official. 7. Once the Professional has determined that the condition is safe, the Professional shall post, upon the fire escape, a tag or placard (made of weather-resistant reflective material) that clearly and legibly states the date of the inspection and the date by which a new inspection is required (5 years after the date of inspection), and the name, address and telephone number of the Professional or fire escape inspection business on the tag or placard. F-1104.16.5.1.8 Report requirements. 1. The Professional who performs the inspection shall submit a written report to the owner of the building. The Professional shall also submit a summary of the written report to the fire code official in a form determined by the fire code official. The fire code official may by regulation impose a fee to cover the reasonable costs of processing that must be paid upon the submission of the summary of the written report. If the report identifies an unsafe condition, then within twenty-four (24) hours of the completion of the report, the Professional shall file the full report with the fire code official, in writing and in an electronic format to be determined by the fire code official. The owner or owner's agent shall retain all written reports submitted pursuant to this Section and keep them readily available for inspection by the fire code official. 2. The report shall include, on the front page, the name and license number of the Professional and the date of the report, and shall include the following information: 2.1. The address of the building. 2.2. The name, mailing address and telephone number of the owner of the building, or where applicable, the owner's agent or person in charge, possession or control of the building. 2.3. A description of the building, including the number of stories and height. 2.4. The date of the start and completion of the inspection and a detailed description of the procedures used in making the inspection. 2.5. A report of all conditions, including, but not limited to, significant deterioration, and movement, and mechanical operations. The report shall classify each such condition as Safe, Unsafe, or Safe with a Repair and Maintenance Program. 2.6. The probable causes of the reported conditions. 2.7. The status of ongoing maintenance efforts. 2.8. For any conditions listed in any previously filed report, whether such conditions have been repaired or maintained as recommended in that report. 2.9. Recommendations for repairs or maintenance, if appropriate, including the recommended time frame for the repairs or maintenance to be performed. 2.10. The classification of the fire escape and fire escape balconies overall according to the following scheme: a. "Unsafe", if there is at least one unsafe condition. b. "Safe with a Repair and Maintenance Program", if there is a condition that is "Safe with Repair and Maintenance Program" and there are no Unsafe conditions. c. "Safe", in all cases other than a or b. 2.11. Photographs or sketches documenting the locations of any conditions that are either Unsafe or Safe with a Repair and Maintenance Program. 2.12. A statement by the Professional indicating which repairs or maintenance require work permits prior to their commencement. 2.13. A statement signed by the owner or agent of the building, acknowledging receipt of a copy of the report and acknowledging any required repairs or maintenance and the recommended time frame for performing such repairs or maintenance. 2.14. The Professional's certification that, to the best of his or her knowledge and belief, the physical inspection was performed in accordance with applicable rules and regulations, including the provisions of this Section, and within the appropriate professional standard of care. 2.15. The Professional's seal and signature in accordance with the professional registration laws of the Commonwealth of Pennsylvania. 2.16. Such other matters as the code official may require by regulation. 3. The Professional may submit an amended report. The amended report shall clearly identify any change from the initial report and all reasons for such changes. F-1104.16.5.1.9 Unsafe conditions. 1. Within twenty-four (24) hours of being notified of an Unsafe condition by a Professional, the owner of the building shall take any and all actions necessary to protect public safety including, but not limited to, posting notice of the unsafe condition in a prominent location inside the building near every exit to an exterior fire escape. If the fire escape or fire escape balcony encroaches upon a public right-of-way, such notice shall be posted in a prominent location visible from the right-of-way and the right-of-way shall be protected by installation of a sidewalk shed or other approved means. Such actions shall be considered part of an effort to remedy an emergency situation, and applications for any required permit shall be filed with the Department of Licenses and Inspections within three (3) days of notification. 2. Within ten (10) days of the receipt of a report identifying an unsafe condition, the owner of a building shall commence work to correct the condition, and work shall continue without interruption until the unsafe condition has been corrected. Within two (2) weeks after the unsafe condition has been corrected, the Professional shall re-inspect the fire escape and fire escape balconies and file with the fire code official a detailed amended report concerning their condition. 3. When a fire escape or fire escape balcony is determined to be unsafe and such condition is considered imminently dangerous by the Professional, the Professional shall notify the fire code official immediately. Signage shall be posted by the owner at each entry point to the fire escape or fire escape balcony and at the lowest balcony. Where required, the building shall either be evacuated, or an approved fire watch shall be provided until the fire escape has been made safe and approved for use. 4. Upon completion of the work necessary to correct the Unsafe condition, the Professional shall submit an amended inspection report to the owner and the Department reflecting the completion of the repairs and the reclassification to Safe. F-1104.16.5.1.10 Conditions that are safe with a repair and maintenance program. The owner of a building is responsible for ensuring that the conditions described in the report as Safe With a Repair and Maintenance Program are repaired and the actions identified by the Professional are completed within the time frame designated in the report, or by such time necessary to prevent a condition from becoming an unsafe condition, whichever is sooner. Delete Section 1104.24 and replace as follows: F-1104.24 Stairway identification signs. Existing stairways shall be marked in accordance with Section 1023.9 and Section F-1104.24.1. F-1104.24.1 Stairway roof access. Where access to the roof from the exit stair enclosure is not direct, but is available through a room or corridor accessed from the exit stair enclosure, the stairway identification sign shall include the words "Indirect Roof Access". A properly oriented floor diagram shall be provided at the exit stair landing at the floor level that provides the indirect roof access. The floor diagram shall indicate the route to the door, stair or ladder that leads to the roof and be located at approximately eye level near the stairway identification sign. Delete Section 1104.25 and replace as follows: F-1104.25 Egress path markings. Existing high-rise buildings of Group A, B, E, I, M and R-1 occupancies shall be provided with luminous egress path markings in accordance with Section 1025. Exceptions: 1. Buildings existing, or where plans for the construction of the building were approved, prior to February 17, 2010, are exempt provided the building has a sprinkler system installed throughout and the exit signs and egress lighting are connected to a primary power supply and an emergency generator or other secondary power supply. 2. Open, unenclosed stairwells in historic buildings designated as historical under a state or local historic preservation program. Add Section F-1104.26 as follows: F-1104.26 Means of egress door operation and locks. Doors in the means of egress shall be readily openable from the egress side without the use of a key or special knowledge or effort. Surface mounted manual slide bolt locks are not permitted Exception: Locking devices permitted by the current or past edition of the Philadelphia Building Code. Add Section F-1104.27 as follows: F-1104.27 Stairways in the means of egress. Stairways in the means of egress shall be free of obstructions. There shall be no storage under the stairways unless the area is enclosed with construction having at least a 1-hour fire resistance rating. Add Section F-1104.28 as follows: F-1104.28 Exit Doors. Exit doors in existing buildings shall be self-closing and latching and in accordance with Sections F-1104.28.1 and F-1104.28.2 F-1104.28.1 Exit door rating. Exit doors shall maintain the fire resistance rating required by the building code in effect at the time of construction, but at a minimum shall have a fire resistance rating of one hour. Where a door is replaced in an existing exit enclosure, the replacement door shall be a labeled fire door with a fire resistance rating of at least one hour. Existing door frames shall be maintained in good repair with no gaps between the door and the door frame exceeding 1/2 inches (16 mm). Exceptions: 1. Where an existing exit enclosure is required to have a fire-resistance rating of up to one hour, existing self-closing and latching doors shall be accepted provided they are solid core wood with a minimum thickness of 1-3/4 inches (44 mm). 2. Where an existing exit enclosure is required to have a one-hour fire-resistance rating, existing self-closing and latching panel doors (not hollow core) shall be accepted provided the panels on one side are filled with a non-combustible material (example: mineral wool) and the entire surface of the door on that side is covered with a sheathing to provide a minimum door thickness of 1-3/4 inches (44 mm) measured at the stiles. F-1104.28.2 Exit stairways doors. Exit stairway doors in existing buildings shall be openable from both sides without the use of a key or special knowledge or effort. Exceptions: 1. Stairway discharge doors shall be openable from the egress side and shall only be locked from the opposite side. 2. Exit doors arranged in accordance with the current or a past edition of the Philadelphia Building Code. 3. In stairways serving not more than 4 stories doors are permitted to be locked on the side opposite egress (stairway side). 4. In stairways serving more than 4 stories the doors are permitted to be locked from the stairway side provided they unlock, but not un-latch, upon the loss of power to the door locks and are in accordance with 4.1 or 4.2: 4.1. Unlock upon the activation of the building fire alarm system. 4.2. Unlocked remotely from a constantly attended location, and telephones or a two-way communication system connected to the constantly attended location are installed in the stairway at not less than every fifth floor. Add Section F-1104.29 as follows: F-1104.29 Buildings with one exit. Where a building with one exit was constructed in conformance with the building code in effect at the time the building was constructed, the single exit is acceptable provided it is in accordance with one of the following conditions: 1. A nonresidential building not exceeding 6 stories above grade. 2. A residential building, other than Group R-3, not exceeding 3 stories above grade. 3. A Group R-3 building of any height. 4. A building equipped with a fire suppression system and fire alarm system throughout the building with smoke detectors in all corridors, lobbies and other common areas. 5. A building equipped with an automatic fire alarm system with smoke detectors installed throughout the building (smoke alarms in dwelling units) and the single exit is a smokeproof enclosure (access to the stairway via a vestibule or open exterior balcony) or a pressurized stairway. 6. Compliance with the current Philadelphia Building Code. Add Section F-1104.30 as follows: F-1104.30 Occupant Load Sign. Every room or space that is an assembly occupancy (50 or more) shall have the occupant load of the room or space, as determined by the Department of Licenses and Inspections, posted on a sign in a conspicuous place, near the main exit or exit access doorway from the room or space. Exception: The nave or worship area of a place of worship area with fixed seating in existence prior to 2010. Add Section F-1104.31 as follows: F-1104.31 Panic hardware. Swinging doors in Group A or E occupancies with an occupant load of 50 or more and Group H occupancies of any number shall be provided with panic hardware on the egress side of the door. Exception: Where permitted by the current or past edition of the Philadelphia Building Code. Add Section F-1104.32 as follows: F-1104.32 Security grilles. The security grilles in buildings shall be secured in the full-open position during the period of occupancy by the general public. When a building is occupied, but not by the general public, security grilles are permitted to be in the closed position provided they are openable from the inside without the use of a key or special knowledge or effort. SECTION 1106 REQUIREMENTS FOR OUTDOOR OPERATIONS Add Section F-1106.2 as follows: F-1106.2 Vehicle salvage and wrecking operations. Facilities conducting vehicle salvage or wrecking operations shall comply with Sections 1106.2.1 through 1106.2.8. F-1106.2.1 Control of combustibles to prevent fire. Combustible rubbish (trash, debris, etc.) on the exterior of a property performing vehicle salvage or wrecking operations shall be stored in containers with lids. Vegetation (bushes, shrubs, grass, weeds, etc.) shall be kept trimmed to prevent it from becoming a fire hazard. Dead and dying vegetation shall be removed. F-1106.2.2 Cutting and welding. Cutting and welding operations shall be in accordance with Chapter 35. F-1106.2.3 Portable fire extinguishers. Portable fire extinguishers shall be in accordance with Section 906. F-1106.2.4 Tire storage. Tire storage shall be neat and orderly. The exterior storage of tires shall be in accordance with Section 1106.1 F-1106.2.5 Vehicle fluids. The storage, handling and use of flammable and combustible liquids shall be in accordance with Chapter 57. Fuel shall be removed from vehicle fuel tanks scheduled for salvage or wrecking within 24 hours of the arrival of a vehicle. Other fluids shall be removed if leaking, but not later than the start of further salvage or wrecking operations. F-1106.2.6 Lead-acid batteries. Lead-acid batteries shall be removed from vehicles if leaking, but not later than the start of further salvage or wrecking operations. F-1106.2.7 Burning of vehicle parts. The burning of vehicle parts is prohibited. F-1106.2.8 Fire access roads. Fire access roads of at least 15 feet in width shall be provided between storage piles and vehicle (whole or in parts) storage areas. CHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS SECTION 2201 GENERAL Delete Section 2201.2 and replace as follows: F-2201.2 Reserved. CHAPTER 12 ENERGY SYSTEMS SECTION 1205 STATIONARY FUEL CELL POWER SYSTEMS Delete Section 1205.2 and replace as follows: F-1205.2 Permits. Permits shall be obtained for the installation of stationary fuel cell power systems in accordance with the Philadelphia Administrative Code. SECTION 1206 ELECTRICAL ENERGY STORAGE SYSTEMS Delete Section 1206.2.1 and replace as follows: F-1206.2.1 Permits. Permits shall be obtained for the installation of stationary storage battery systems in accordance with the Philadelphia Administrative Code. Delete Section 1206.3.1 and replace as follows: F-1206.3.1 Permits. Permits shall be obtained for the installation of capacitor energy storage systems in accordance with the Philadelphia Administrative Code. CHAPTER 20 AVIATION FACILITIES SECTION 2001 GENERAL Delete Section 2001.3 and replace as follows: F-2001.3 Permits and licenses. For permits for the installation of aircraft-refueling facilities, see Section F-105.9.5. For permits for the installation of facilities for the application of flammable or combustible finishes, see Section F-105.9.14. For the license for hot work, see Section F-105.6.7. CHAPTER 21 DRY CLEANING SECTION 2101 GENERAL Delete Section 2101.2 and replace as follows: F-2101.2 License required. Licenses shall be required as set forth in Section F-105.6.1. CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES SECTION 2301 GENERAL Delete Section 2301.2 and replace as follows: F-2301.2 License required. Licenses shall be required as set forth in Section F-105.6.4. CHAPTER 24 FLAMMABLE FINISHES SECTION 2401 GENERAL Delete Section 2401.3 and replace as follows: F-2401.3 Permits and licenses. Permits and licenses shall be required as set forth in Sections F-105.6.1 and F-105.9.14. CHAPTER 25 FRUIT AND CROP RIPENING SECTION 2501 GENERAL Delete Section 2501.2 and replace as follows: F-2501.2 Licenses. Hazardous material licenses shall be required as set forth in Section F-105.6.1. CHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING SECTION 2601 GENERAL Delete Section 2601.2 and replace as follows: F-2601.2 Licenses. Hazardous material licenses shall be required as set forth in Section F-105.6.1. CHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES SECTION 2701 GENERAL Delete Section 2701.5 and replace as follows: F-2701.5 Reserved. CHAPTER 28 LUMBER YARDS AND AGRO-INDUSTRIAL, SOLID BIOMASS AND WOODWORKING FACILITIES SECTION 2801 GENERAL Delete Section 2801.2 and replace as follows: F-2801.2 Reserved. CHAPTER 29 MANUFACTURE OF ORGANIC COATINGS SECTION 2901 GENERAL Delete Section 2901.2 and replace as follows: F-2901.2 Licenses. Hazardous material licenses shall be required as set forth in Section F-105.6.1. CHAPTER 30 INDUSTRIAL OVENS SECTION 3001 GENERAL Delete Section 3001.2 and replace as follows: F-3001.2 Permits. Permits shall be required as set forth in Section F-105.9.8. CHAPTER 31 TENTS, TEMPORARY SPECIAL EVENT STRUCTURES AND OTHER MEMBRANE STRUCTURES SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES Delete Section 3103.4 and replace as follows: F-3103.4 Permits. Permits shall be required as set forth in Sections F-105.7.2 and F-105.9.16. SECTION 3105 TEMPORARY SPECIAL EVENT STRUCTURES Delete Section 3105.3 and replace as follows: F-3105.3 Permits. Permits shall be required as set forth in Section F-105.9.13. SECTION 3106 OUTDOOR ASSEMBLY EVENTS Delete Section 3106.2.2 and replace as follows: F-3106.2.2 Permits. Permits shall be required as set forth in Section F-105.9.9. CHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE SECTION 3201 GENERAL Delete Section 3201.2 and replace as follows: F-3201.2 Permits. A permit shall be required as set forth in Section F-105.9.7. CHAPTER 34 TIRE REBUILDING AND TIRE STORAGE SECTION 3401 GENERAL Delete Section 3401.2 and replace as follows: F-3401.2 Licenses. A license shall be required as set forth in F-105.6.5. CHAPTER 35 WELDING AND OTHER HOT WORK SECTION 3501 GENERAL Delete Section 3501.2 and replace as follows: F-3501.2 Licenses. A license shall be required as set forth in F-105.6.7. CHAPTER 37 COMBUSTIBLE FIBERS SECTION 3701 GENERAL Delete Section 3701.3 and replace as follows: F-3701.3 Reserved. CHAPTER 39 PROCESSING AND EXTRACTION FACILITIES SECTION 3901 GENERAL Delete Section 3901.3 and replace as follows: F-3901.3 Reserved. CHAPTER 50 HAZARDOUS MATERIALS GENERAL PROVISIONS SECTION 5001 GENERAL Delete Section 5001.5 and replace as follows: F-5001.5 Permits and licenses. Permits and licenses shall be required as set forth by Sections F-105.9.5 and F-105.6.1. Add Sections F-5001.7 through F-5001.7.10 as follows: F-5001.7 Hazardous material emergency planning and response. Pursuant to SARA Title III and Pennsylvania Hazardous Material Emergency Planning and Response Act 165 of 1990 (Act 165), the requirements of Sections 5001.7.1 through 5001.9.2.2 have been established to provide for hazardous material emergency planning and response. F-5001.7.1 Philadelphia Local Emergency Planning Committee. The Philadelphia Local Emergency Planning Committee (PLEPC) has been established pursuant to subsection 203(a) of Act 165 and is composed as follows: 1. Mayor or designee. 2. Managing Director or designee. 3. Chairperson of the Public Safety Committee of City Council or designee. 4. Emergency Management Director of the City. 5. At least one person from each of the following City departments, agencies or offices: 5.1. Fire Department. 5.2. Police Department. 5.3. Department of Public Health. 5.4. Law Department. 5.5. Department of Licenses and Inspections. 5.6. Water Department. 6. One person representing the following entities or groups is invited to be a member: 6.1. United States Coast Guard Sector Delaware Bay. 6.2. Southeastern Pennsylvania Transportation Authority. 6.3. American Red Cross, Southeastern Pennsylvania Chapter. 6.4. Hospitals and/or health care agencies. 6.5. Environmental advocacy organizations. 6.6. Owners and operators of regulated facilities. 6.7. Community groups not affiliated with emergency service groups. 6.8. Broadcast and print media. 6.9. Railroads and or other transportation carriers. 6.10. Streets Department. 6.11. City Planning Commissioner. F-5001.7.2 Appointment of members to PLEPC. Pursuant to Act 165, the members of the PLEPC have been appointed by the Pennsylvania Emergency Management Agency. Should a vacancy occur in the PLEPC, the Emergency Management Services Director shall nominate to the Pennsylvania Emergency Management Agency a successor member who has been nominated by the represented organization or industry in which the vacancy occurs, if applicable. If the vacancy occurs within a represented category (listed in Item 6 of Section 5001.7.1), then the Emergency Management Director shall cause a nominating committee to be formed consisting of PLEPC members to recommend a replacement member, who shall in turn be nominated to the Pennsylvania Emergency Management Agency. F-5001.7.3 Emergency Management Director. Pursuant to Act 165, the City's Emergency Management Director, who is the person designated by the Mayor to perform emergency management functions, shall have the lead responsibility for ensuring that the plans and activities of PLEPC comply with SARA Title III, Act 165 and other applicable statutes, laws and ordinances. F-5001.7.4 Emergency response plan. The Comprehensive Local Emergency Response Plan (Emergency Response Plan) required by Section 303 of SARA Title III and Section 203(k) of Act 165 shall include, but not be limited to, each of the following: 1. Identification of each Regulated Facility within the City, identification of routes likely to be used for the transportation of substances on the list of Extremely Hazardous Substances and identification of additional facilities contributing or subject to additional risk due to their proximity to the Regulated Facility subject to the requirement of this Section, such as hospitals or natural gas facilities. 2. Methods and procedures to be followed by Regulated Facility owners and operators and local emergency and medical personnel to respond to any Release of such substances. 3. Designation of a community emergency coordinator and Regulated Facility emergency coordinators who shall make determinations necessary to implement the Emergency. 4. Procedures providing reliable, effective and timely notification by the Regulated Facility emergency coordinators and the City Emergency Management Director to persons designated in the Emergency Response Plan and to the public, that a Release has occurred, consistent with the notification requirements of Section 304 of SARA Title III. 5. Methods for determining the occurrence of a Release, and the area of population likely to be affected by such Release. 6. A description of emergency equipment and facilities in the City and at each Regulated Facility and an identification of persons responsible for such equipment and facilities. 7. Evacuation plans, including provisions for a precautionary evacuation and alternative traffic routes. 8. Training programs, including schedules for training of local emergency response and medical personnel. Training shall meet the minimum standards outlined in 29 Code of Federal Regulations 1910.1200, Hazardous Waste Operations and Emergency Response. 9. Methods and schedules for exercising the Emergency Response Plan. F-5001.7.5 Hazardous Material Emergency Response Preparedness Assessment. The City Emergency Management Director shall develop and submit to the Pennsylvania Emergency Management Agency a Hazardous Material Emergency Response Preparedness Assessment (the Assessment) in accordance with Section 204(a)(3) of Act 165. The Assessment shall be updated annually. The City shall assess the potential dangers and risks that hazardous material Releases from Regulated Facilities and transportation accidents pose to public health and the environment, identify the City's needs and resources for hazardous material response teams to deal with those dangers and risks and outline its plan for implementing City emergency planning functions under Act 165. The Assessment shall include the following: 1. Potential threats posed by Regulated Facilities required to be included in the City's Emergency Response Plan under Section 303 of SARA Title III, and other concentrations of hazardous material in the City or in areas immediately adjacent to the City that may pose a threat. 2. Potential threats posed by hazardous material transported by highway and railroad in the City. 3. Identification of existing capabilities to respond to hazardous material Releases, including personnel, equipment, training, planning and identification of existing hazardous material response zones. 4. Organization and operation of a certified hazardous material response team under Section 209(e) of Act 165 and identification of the need for personnel, equipment, training and planning needed to respond to potential threats, including the designation of proposed levels of preparedness for the City's hazardous material response team. 5. Identification of other resources needed to implement the provisions of Act 165 and to support the PLEPC. 6. An audit of the Hazardous Material Emergency Response Account. F-5001.7.6 Hazardous Material Emergency Response Account. A non-lapsing restricted account, known as the Hazardous Material Emergency Response Account (HMER Account) and established within the Grants Revenue Fund by the City Finance Department shall consist of all fees authorized by this subsection, City, federal, or state funds, grants, loans or penalties and any private donations provided to finance the hazardous material safety program established pursuant to Act 165. Expenditures from the HMER Account shall be made pursuant to appropriations from the HMER Account of the Grants Revenue Fund and consistent with the needs identified in the City's Assessment. The PLEPC shall be consulted with respect to the consistency of proposed expenditures with the needs identified in the assessment. F-5001.7.7 Hazardous Chemical Fee. By March 1 of every year, each owner or operator of a Regulated Facility shall pay to the City Revenue Department (via the PLEPC Tier II Coordinator), to be deposited in the HMER Account, a Hazardous Chemical Fee for each hazardous chemical which is required by Section 312 of SARA Title III to be listed on the hazardous chemical inventory form (Tier II) which the owner or operator of a Regulated Facility submits to the PLEPC, provided that no fee may be applied to additional facilities or hazardous materials because of changes made by the United States Environmental Protection Agency in lists of hazardous materials, threshold planning quantities or other requirements under SARA Title III, unless there has been compliance with the provisions of Section 213 of Act 165. A credit in an amount up to one hundred percent (100%) of the Hazardous Chemical Fee obligation shall be given to Regulated Facility owners or operators for training, equipment or other in-kind services donated to the City to support the hazardous material safety program, if such training, equipment or in-kind services are accepted by the City upon approval of the Emergency Management Director following a review by the PLEPC of a written proposal of donation. The PLEPC shall recommend to the City's Emergency Management Director whether or in what amount a credit for such training, equipment or in-kind services shall be extended to a Regulated Facility owner or operator. Each agreement by the City to accept such a donation in exchange for a credit toward the Hazardous Chemical Fee obligation shall be written, and shall specify the amount of credit to be awarded, based on the fair market value of equipment donated and the agreed-upon value of training or in-kind services donated. The owners or operators of family farm enterprises, service stations (as such terms are defined in Act 165) and Regulated Facilities owned by state and local governments shall be exempt from payment of the fees required in this Section. F-5001.7.8 Emergency Planning Fee. By March 1 of every year, each owner or operator of a Regulated Facility that manufactures, produces, uses, stores, supplies or distributes any Extremely Hazardous Substance in quantities larger than the threshold planning quantities shall pay to the City Revenue Department for each Regulated Facility an Emergency Planning Fee. A credit in the amount of one hundred percent (100%) of this Emergency Planning Fee shall be available to Regulated Facility owners or operators for training, equipment or other in-kind services donated to the City to support the hazardous material safety program if such training, equipment or in-kind services are accepted by the City in the same manner provided for acceptance of donations credited to the Hazardous Chemical Fee in Section 5001.7.7 and are in addition to those for which credit is claimed under Section 5001.7.7. The owners or operators of family farm enterprises, service stations (as such terms are defined in Act 165) and Regulated Facilities owned by state and local governments shall be exempt from payment of the fees required by this Section. F-5001.7.9 Limited liability of members of the PLEPC. Pursuant to Act 165, no member of the PLEPC shall be liable for the death of, or any injury to persons or loss or damage to property or the environment or any civil damages resulting from any act or omission arising out of the performance of the functions, duties and responsibilities of the PLEPC, except for acts or omissions which constitute willful misconduct. F-5001.7.10 Relationship to federal and state laws. The requirements of Section F-5001.7 shall be read in conjunction with federal and state acts, laws or regulations providing for the identification, labeling or reporting of information concerning hazardous material Releases, and any other health and safety matters related to hazardous materials, and is intended to supplement federal and state acts, laws and regulations in the interest of protecting the health and safety of the citizens of this City. In those instances where the provisions of Section F-5001.7 are more comprehensive or stringent than the provisions of an applicable federal or state act, law or regulation, the provisions of Section F-5001.7 shall be controlling. Add Sections F-5001.8 through F-5001.8.1 as follows: F-5001.8 Equipment containing polychlorinated biphenyls. Facilities shall be in compliance with the proper marking, use, storage, disposal and record keeping requirements for polychlorinated biphenyls (PCBs) in the United States Environmental Protection Agency, 40 Code of Federal Regulations (CFR), Part 761. In general, the CFR requires equipment containing PCBs exceeding 500 parts per million (ppm) to be marked: CAUTION - CONTAINS PCBs. Marking of equipment containing between 50 and 500 ppm PCBs is optional, but if marked shall read: PCB CONTAMINATED. The location of equipment marked pursuant to federal regulation shall be reported to the fire department. F-5001.8.1 Inspection of PCB equipment. The fire department is authorized to conduct inspections of equipment containing PCBs for compliance with federal and other safety regulations. Add Sections F-5001.9 through F-5001.9.2.2 as follows: F-5001.9 Chemical plant/refinery emergency coordination. Chemical plants and refineries shall plan, train and exercise with the fire department, the Managing Director's Office of Emergency Management and other City agencies to establish and maintain operating procedures and equipment to be used during fires or other emergencies at a facility. F-5001.9.1 Emergency procedures. Facilities that have hazardous materials in quantities exceeding 10,000 pounds (4540 kg) or who have extremely hazardous substances as regulated by the Environmental Protection Agency (EPA) and Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA Title III) and appearing on the EPA's Community Right to Know Chemical List shall prepare procedures to be followed during an emergency at their facility, including the immediate notification of the fire department. A copy of the procedures shall be sent to the fire department and the Philadelphia Local Emergency Planning Committee. Managers shall ensure that employees are knowledgeable of their responsibilities during emergencies. Emergency procedures shall be posted in prominent locations or stored in readily available locations throughout a facility. F-5001.9.2 Facilities with in-plant fire brigades. Petroleum refineries and chemical plants with in-plant fire brigades shall assign knowledgeable personnel to all operating shifts to act as plant emergency coordinators who shall be responsible for coordinating with fire department and other emergency officials during fires or other emergencies. F-5001.9.2.1 Review of emergency procedures. Annually, the designated coordinator of a facility with an in-plant fire brigade shall meet with the Deputy Commissioner of Operations of the fire department and the Emergency Management Director, or their designees, to review and coordinate plant firefighting and emergency procedures to ensure that their procedures are compatible with fire department operations and the City's emergency management plan. Emergency procedures and training should be consistent with NFPA 30. F-5001.9.2.2 Communications during an emergency. Facilities with in-plant fire brigades shall have two portable radios capable of receiving and transmitting on the fire department's fire ground radio frequencies. The radios shall be for use by plant emergency coordinators to maintain communications with fire department personnel during emergencies. Add Section F-5001.10 as follows: F-5001.10 Restriction on use of hydrogen fluoride. No facility engaged in the processing or production of gasoline, heating oil, or other hydrocarbon products from petroleum or crude oil shall use hydrogen fluoride, meaning anhydrous, aqueous, or any mixture of hydrogen fluoride, including hydrofluoric acid and modified hydrofluoric acid, as an alkylation catalyst or for any other petroleum or crude-oil processing purpose. [History: Added, Bill No. 200147 (approved July 13, 2020).] SECTION 5003 GENERAL REQUIREMENTS Delete Section 5003.4 and replace as follows: F-5003.4 Safety Data Sheets. Safety Data Sheets (SDS) shall be readily available on the premises for hazardous materials regulated by this Chapter and in accordance with Section F-5003.4.1. When a hazardous substance is developed in a laboratory, available information shall be documented. Exception: Designated hazardous waste. Add Section F-5003.4.1 as follows: F-5003.4.1 Storage of Safety Data Sheets. Safety Data Sheets (SDS) shall be stored on the exterior of a facility (building wall, fence, post mounted, etc.) in a storage container at a location readily available to emergency responders on a 24-hour basis. The container shall be weather-resistant and locked by a padlock. Where there is a concern that the storage container may be subject to vandalism, installation of the container is permitted up to a maximum height of 10 feet (3048 mm). The location of the container shall be subject to approval by the fire department. Exceptions: 1. Facilities with an emergency control center staffed 24-hours per day are permitted to provide the required information by an alternative means approved by the fire department. 2. Facilities utilizing an off-site electronic records storage company to maintain their SDS records, provided the arrangement is approved by the fire department. 3. Where the number of SDS is too large to store in the Emergency Information Container, information in the container shall indicate the location of the on-site SDS, provided they are readily available for utilization by emergency response personnel and the location is approved by the fire department. CHAPTER 51 AEROSOLS SECTION 5101 GENERAL Delete Section 5101.2 and replace as follows: F-5101.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 53 COMPRESSED GASES SECTION 5301 GENERAL Delete Section 5301.2 and replace as follows: F-5301.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 54 CORROSIVE MATERIAL SECTION 5401 GENERAL Delete Section 5401.2 and replace as follows: F-5401.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 55 CRYOGENIC FLUIDS SECTION 5501 GENERAL Delete Section 5501.2 and replace as follows: F-5501.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION 5601 GENERAL Delete Section 5601.1.3 and replace as follows: F-5601.1.3 Fireworks. The possession, manufacture, storage, sale, handling and use of fireworks are prohibited. Exceptions: 1. Storage and handling of fireworks as allowed in Section 5604 when approved by the fire department. 2. Manufacture, assembly and testing of fireworks as allowed in Section 5605 when approved by the fire department. 3. The use of fireworks for fireworks displays as allowed by Section 5608 when approved by the fire department. 4. The possession, storage, sale, handling and use of specific types of Division 1.4G fireworks (consumer fireworks) where allowed by the Pennsylvania Fireworks (Act 43 of 2017) ("Act 43") and in accordance with this Chapter, provided that such fireworks and facilities comply with NFPA 1124, CPSC 16 CFR Parts 1500 and 1507, and DOTn 49 CFR Parts 100-185, as applicable for consumer fireworks. The use of consumer fireworks shall be in accordance with Sections F-5601.1.3.1 through F-5601.1.3.3 which are requirements of Act 43. 5. Sales locations for consumer fireworks licensed by the Commonwealth of Pennsylvania pursuant to Act 43. F-5601.1.3.1 Age of purchaser and user of consumer fireworks. Persons must be at least 18 years of age to purchase, possess or use consumer fireworks. F-5601.1.3.2 Prohibited locations. Consumer fireworks shall not be used on public or private property without written approval from the owner. F-5601.1.3.3 Distance from structures and hazards. Consumer fireworks shall not be used within 150 feet of an occupied structure or under trees or power lines. Delete 5601.2 (Retain Sections 5601.2.1 through 5601.2.3) and replace as follows: F-5601.2 Permits required. Permits for the use of explosives and fireworks displays shall be required as set forth in Sections F-105.7.1 and F-105.8 and regulated in accordance with this Section. Applications for the use of explosives for building demolitions shall be submitted at least 90 days in advance of the proposed date and for all other uses at least 21 days in advance. Applicants shall also follow the specific requirements of the various city departments charged with ensuring the safe demolition of buildings by explosives. Delete Section 5601.2.4 (Retain 5601.2.4.1 and 5601.2.4.2) and replace as follows: F-5601.2.4 Financial responsibility. Before a permit is issued for the use of explosives, as required by Sections F-105.7.1 and F-5601.2, the applicant shall file with the City a corporate surety bond or a certificate of public liability and property damage insurance from an insurance company authorized to write such insurance in the Commonwealth of Pennsylvania. in an amount determined by the City, for the purpose of the payment of all damages to persons or property which arise from, or are caused by, the conduct of any act authorized by the permit upon which any judicial judgment results. The fire code official is authorized to specify a greater or lesser amount when, in his or her opinion, conditions at the location of use indicate a greater or lesser amount is required. Government entities shall be exempt from this bond requirement. All costs associated with the clean-up of dust and debris from demolition by explosives shall be borne by the contractor. All costs for cold weather provisions for demolition by explosives, including water additives, shall be borne by the contractor. Add Section F-5601.2.5 as follows: F-5601.2.5 Use of explosives for other than building demolition. Persons desiring to use explosives for purposes other than the demolition of a building are required to comply with Items 1 and 2 that follow and other requirements of this Chapter. 1. An application for an "Operational Permit - Use of Explosives" shall be submitted to the Managing Director's Office, Fire Department, and Department of Licenses and Inspections at least 21 days in advance of the requested blasting date. The Police Department and the City Councilmember elected from the district in which the explosives are to be used shall be notified at least 21 days in advance of the blasting date. 2. If requested by the Managing Director's office or the City Councilmember, a community meeting shall be held to inform neighborhood residents of the proposed blasting date and the precautions that will be undertaken to assure the safety of residents and their property. Delete Section 5605.1 and replace as follows: F-5605.1 General. The assembly and testing of explosives, ammunition, blasting agents and fireworks shall comply with the requirements of this Section and NFPA 495 or NFPA 1124. Prior to issuance of a permit, approval shall be obtained from the police department for the use of explosives and blasting agents and from the fire department for the use of fireworks. The manufacture of explosives, blasting agents and fireworks is not permitted within the jurisdiction of the City of Philadelphia. Exceptions: 1. The hand loading of small arms ammunition prepared for personal use and not offered for resale. 2. The mixing and loading of blasting agents at blasting sites in accordance with NFPA 495. 3. The use of binary explosives or plosophoric materials in blasting or pyrotechnic special effects applications in accordance with NFPA 495 or NFPA 1126. Delete Section 5608.2 and replace as follows: F-5608.2 Permit application. Prior to the fire department's issuing a permit for a fireworks display, plans for the fireworks display, including inspections of the display site and demonstrations of the display operations, procedures to follow and actions to be taken in the event that a shell fails to ignite in, or discharge from, a mortar or fails to function over the fallout area or other malfunctions, shall be provided to the fire department for approval. Applications for Assisted Operation Permits for fireworks and pyrotechnic displays shall be submitted at least 15 days in advance of the event. Prior to the issuance of a permit for fireworks displays, the applicant shall submit a diagram of the site, type and number of fireworks and/or pyrotechnic effects, qualifications of the operator and proof of insurance. Approval by the fire department is required for all fireworks and pyrotechnic displays. Launching racks shall be in accordance with requirements of the fire department. CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS SECTION 5701 GENERAL Delete Section 5701.4 and replace as follows: F-5701.4 Licenses and permits. Licenses and permits shall be required as set forth in Sections F-105.6.1 and F-105.9.5. SECTION 5704 STORAGE Add Section F-5704.2.12.2.1 as follows: F-5704.2.12.2.1 Periodic testing of underground tanks. Every 5 years, or more frequently where required by the manufacturer's instructions, underground tanks shall be tested for tightness in accordance with NFPA 329. A leak shall exist if the net change exceeds 0.1 gallons (0.4 L) per hour. Exception: Underground tank systems that have automatic tank gauging, inventory reconciliation analysis or secondary containment with interstitial monitoring. Delete Section 5704.2.13.1.4 and replace as follows: F-5704.2.13.1.4 Tanks abandoned in place. The procedure for tanks abandoned in place shall be as follows: 1. Flammable and combustible liquids shall be removed from the tank and connected piping. 2. The suction, inlet, gauge, vapor return and vapor lines shall be disconnected. 3. The tank shall be filled completely with an approved inert solid material. 4. Remaining underground piping shall be capped or plugged. 5. A record of tank size, location and date of abandonment shall be retained. 6. All exterior above-grade fill piping shall be permanently removed when tanks are abandoned or removed. 7. A site assessment, to determine if there is any soil or ground water contamination, shall be conducted in accordance with requirements of the Pennsylvania Department of Environmental Protection (PADEP). The site assessment report shall be performed for all abandoned tanks, including those not regulated by PADEP. A copy of the site assessment, documentation of any required site remediation and a closure report shall be maintained by the property owner. SECTION 5706 SPECIAL OPERATIONS Delete Section 5706.2.4.4 and replace as follows: F-5706.2.4.4 Locations where above-ground tanks are prohibited. The storage of Class I and II liquids in above-ground tanks is prohibited on premises accessible by the public. The storage of Class I, II and IIIA liquids in above-ground tanks on farms and at construction sites shall be approved by the fire department if, after a review of the fire hazards at the location and the capacity of the tank, the fire department determines that it is safe to install an above-ground tank. Tanks approved for use at construction sites shall be double-wall tanks. CHAPTER 58 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 5801 GENERAL Delete Section 5801.2 and replace as follows: F-5801.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 59 FLAMMABLE SOLIDS SECTION 5901 GENERAL Delete Section 5901.2 and replace as follows: F-5901.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS SECTION 6001 GENERAL Delete Section 6001.2 and replace as follows: F-6001.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 61 LIQUEFIED PETROLEUM GASES SECTION 6101 GENERAL Delete Section 6101.2 and replace as follows: F-6101.2 Permits. Permits shall be obtained from the Pennsylvania Department of Labor and Industry in accordance with the Pennsylvania Propane and Liquefied Petroleum Gas Act of 2002. Delete Section 6101.3 and replace as follows: F-6101.3 Construction documents. Construction documents and a site plan shall be submitted to the fire department for all temporary or permanent installations of LP-gas in accordance with Section F-6104.2. SECTION 6104 LOCATION OF LP-GAS CONTAINERS Delete Section 6104.2 and replace as follows: F-6104.2 Fire safety in heavily populated or congested areas. Due to most areas of the City of Philadelphia being heavily populated or congested, the fire department shall review all applications and installations for LP-gas to ensure they are in compliance with the requirements of the Pennsylvania Propane and Liquefied Petroleum Gas Act of 2002 and NFPA 54 and 58. CHAPTER 62 ORGANIC PEROXIDES SECTION 6201 GENERAL Delete Section 6201.2 and replace as follows: F-6201.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS SECTION 6301 GENERAL Delete Section 6301.2 and replace as follows: F-6301.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 64 PYROPHORIC MATERIALS SECTION 6401 GENERAL Delete Section 6401.2 and replace as follows: F-6401.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 65 PYROXYLIN (CELLULOSE NITRATE) PLASTICS SECTION 6501 GENERAL Delete Section 6501.2 and replace as follows: F-6501.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 66 UNSTABLE (REACTIVE) MATERIALS SECTION 6601 GENERAL Delete Section 6601.2 and replace as follows: F-6601.2 Licenses. A license shall be required as set forth in Section F-105.6.1. CHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS SECTION 6701 GENERAL Delete Section 6701.2 and replace as follows: F-6701.2 Licenses. A license shall be required as set forth in Section F-105.6.1. APPENDICES Add Appendix O as follows. Appendices A through N have not been adopted. APPENDIX O ELEVATOR CALL STATION PICTOGRAPH [image] ELEVATOR CALL STATION PICTOGRAPH [image] HIGH-RISE BUILDING ELEVATOR CALL STATION FLOOR DIAGRAM [History: Enrolled bill read "pictograp".] SUBCODE "G" (THE PHILADELPHIA FUEL GAS CODE) Article G-1.0 Adoption of the “2021 International Fuel Gas Code”, pursuant to the Pennsylvania Uniform Construction Code Act (“Act”), with state amendments and local amendments that were in effect prior to enactment of the Act or approved pursuant to Section 503 of the Act. § G-1.1 The “2021 International Fuel Gas Code”, as published by the International Code Council, is hereby adopted as the Fuel Gas Code of the City of Philadelphia and is incorporated as if fully set forth herein, subject to the amendments provided in this Subcode G. Editor's note: The 2021 International Fuel Gas Code can be found at: https://codes.iccsafe.org/content/IFGC2021P1 § G-1.1.1 The numbers of all local amendments shall be preceded with the prefix “G-”. § G-1.1.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. [History: Added, Bill No. 030775 (approved December 31, 2003); repealed and replaced, Bill No. 180176 (approved June 6, 2018). Section 7 of Bill No. 180176 provides: "The provisions of this Ordinance shall be effective October 1, 2018, and upon taking effect replace and supersede previously adopted Regulations of the Department of Licenses and Inspections related to Subcode B and Subcode M." Repealed and replaced, Bill No. 260392 (approved June 12, 2026).] CHAPTER 1 SCOPE AND ADMINISTRATION [Delete contents of entire Chapter and replace as follows:] SECTION G-101 (IFGC) GENERAL G-101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Fuel Gas Code and will be referred to herein as “The Philadelphia Fuel Gas Code” or “this code”. G-101.2 Scope. The Philadelphia Fuel Gas Code shall apply to the installation of fuel-gas piping systems, fuel-gas utilization equipment and related accessories in accordance with Sections G-101.2.1 through G-101.2.5. Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the Philadelphia Residential Code (Subcode R). G-101.2.1 Gaseous hydrogen systems. Gaseous hydrogen systems shall be regulated by Chapter 7. G-101.2.2 Piping systems. These regulations cover piping systems for natural gas with an operating pressure of 125 pounds per square inch gauge (psig) (862 kPa gauge) or less, and for LP-gas with an operating pressure of 20 psig (140 kPa gauge) or less, except as provided in Section 402.7. Coverage shall extend from the point of delivery to the outlet of the equipment shutoff valves. Piping systems requirements shall include design, materials, components, fabrication, assembly, installation, testing, inspection, operation and maintenance. G-101.2.3 Gas appliances. Requirements for gas appliances and related accessories shall include installation, combustion and ventilation air, and venting and connections to piping systems. G-101.2.4 Systems, appliances and equipment outside the scope. This code shall not apply to the following: 1. Portable LP-gas appliances and equipment of all types that is not connected to a fixed fuel piping system. 2. Installation of farm appliances and equipment such as brooders, dehydrators, dryers and irrigation equipment. 3. Raw material (feedstock) applications except for piping to special atmosphere generators. 4. Oxygen-fuel gas cutting and welding systems. 5. Industrial gas applications using gases such as acetylene and acetylenic compounds, hydrogen, ammonia, carbon monoxide, oxygen and nitrogen. 6. Petroleum refineries, pipeline compressor or pumping stations, loading terminals, compounding plants, refinery tank farms and natural gas processing plants. 7. Integrated chemical plants or portions of such plants where flammable or combustible liquids or gases are produced by, or used in, chemical reactions. 8. LP-gas installations at utility gas plants. 9. Liquefied natural gas (LNG) installations. 10. Fuel gas piping in power and atomic energy plants. 11. Proprietary items of equipment, apparatus or instruments such as gas-generating sets, compressors and calorimeters. 12. LP-gas equipment for vaporization, gas mixing and gas manufacturing. 13. Temporary LP-gas piping for buildings under construction or renovation that is not to become part of the permanent piping system. 14. Installation of LP-gas systems for railroad switch heating. 15. Installation of hydrogen gas, LP-gas and compressed natural gas (CNG) systems on vehicles. 16. Except as provided in Section 401.1.1, gas piping, meters, gas pressure regulators and other appurtenances used by the serving gas supplier in the distribution of gas, other than undiluted LP-gas. 17. Building design and construction, except as specified herein. 18. Piping systems for mixtures of gas and air within the flammable range with an operating pressure greater than 10 psig (69 kPa gauge). 19. Portable fuel cell appliances that are neither connected to a fixed piping system nor interconnected to a power grid. G-101.2.5 Other fuels. The requirements for the design, installation, maintenance, alteration and inspection of mechanical systems operating with fuels other than fuel gas shall be regulated by the Philadelphia Mechanical Code (Subcode M). G-101.3 Appendices. No appendices are adopted as a part of this code. G-101.4 Intent. The purpose of this code is to establish minimum standards to provide a reasonable level of safety, health, property protection and public welfare by regulating and controlling the design, construction, installation, quality of materials, location, operation and maintenance or use of fuel gas systems. G-101.5 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are as set forth in the Administrative Code (Subcode A). SECTION G-102 (IFGC) INSPECTIONS AND TESTING G-102.1 Evaluation and follow-up inspection services. Prior to the approval of a prefabricated construction assembly having concealed work and the issuance of a permit, the code official shall require the submittal of an evaluation report from an approved agency on each prefabricated construction assembly. The report shall indicate the complete details of the installation, including a description of the system and its components, the basis upon which the system is being evaluated, test results and similar information and other data as necessary for the code official to determine conformance to this code. Exception: Manufactured and Industrialized housing pursuant to Section A-102.12 of the Administrative Code (Subcode A). G-102.1.1 Follow-up inspection. Except where ready access is provided to installations, service equipment and accessories for complete inspection at the site without disassembly or dismantling, the code official shall conduct in-plant inspections to ensure conformance to the approved evaluation report or shall accept inspection reports from an approved independent inspection agency. The inspection agency shall furnish the code official with the follow-up inspection manual and a report of inspections upon request. The installation shall have an identifying label permanently affixed to the system indicating that factory inspections have been performed. G-102.1.2 Test and inspection records. Required test and inspection records shall be available to the code official at all times during the fabrication of the installation and the erection of the building. G-102.2 Testing. Installations shall be tested as required in this code and in accordance with Sections G-102.2.1 through G-102.2.3. Tests shall be made by the permit holder after notifying the code official, who shall have the authority to observe the tests. G-102.2.1 New, altered, extended or repaired installations. New installations and parts of existing installations, which have been altered, extended, renovated or repaired, shall be tested as prescribed herein to disclose leaks and defects. G-102.2.2 Apparatus, instruments, material and labor for tests. Apparatus, instruments, material and labor required for testing an installation or part thereof shall be furnished by the permit holder. G-102.2.3 Reinspection and testing. Where any work or installation does not pass an initial test or inspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be reinspected or re-tested, and the results resubmitted to the code official as appropriate. SUBCODE "M" (THE PHILADELPHIA MECHANICAL CODE) Article M-1.0 Adoption of the “2021 International Mechanical Code”, pursuant to the Pennsylvania Uniform Construction Code Act (“Act”), with state amendments and local amendments that were in effect prior to enactment of the Act or approved pursuant to Section 503 of the Act. § M-1.1 The “2021 International Mechanical Code”, as published by the International Code Council, is hereby adopted as the Mechanical Code of the City of Philadelphia and is incorporated as if fully set forth herein, subject to the amendments provided in this Subcode M. Editor's note: The 2021 International Mechanical Code can be found at: https://codes.iccsafe.org/content/IMC2021P3 § M-1.1.1 The numbers of all local amendments shall be preceded with the prefix “M-”. § M-1.1.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. [History: Added, Bill No. 970038 (approved March 19, 1997); repealed and replaced, Bill No. 030772 (approved December 31, 2003); repealed and replaced, Bill No. 180176 (approved June 6, 2018). Section 7 of Bill No. 180176 provides: "The provisions of this Ordinance shall be effective October 1, 2018, and upon taking effect replace and supersede previously adopted Regulations of the Department of Licenses and Inspections related to Subcode B and Subcode M." Repealed and replaced, Bill No. 260391 (approved June 12, 2026).] CHAPTER 1 SCOPE AND ADMINISTRATION [Delete contents of entire Chapter and replace as follows:] SECTION M-101 GENERAL M-101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Mechanical Code, and will be referred to herein as the “Philadelphia Mechanical Code” or “this code”. M-101.2 Scope. The Philadelphia Mechanical Code shall regulate the design, installation, maintenance, alteration and inspection of mechanical systems that are permanently installed and utilized to provide control of environmental conditions and related processes within buildings. This code shall also regulate those mechanical systems, system components, equipment and appliances specifically addressed herein. The installation of fuel gas distribution piping and equipment, fuel gas-fired appliances and fuel gas-fired appliance venting systems shall be regulated by the Philadelphia Fuel Gas Code (Subcode G). Exception: Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with the Philadelphia Residential Code (Subcode R). M-101.3 Appendices. No appendices are adopted as a part of this code. M-101.4 Intent. The purpose of this code is to provide minimum standards to safeguard life or limb, health, property and public welfare by regulating and controlling the design, construction, installation, quality of materials, location, operation and maintenance or use of mechanical systems. M-101.5 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are as set forth in the Administrative Code (Subcode A). M-101.6 Conflicts. Pursuant to the Pennsylvania Uniform Construction Code Act, a provision of the “International Mechanical Code” does not apply if the provision conflicts with the Boiler and Unfired Pressure Vessel Law (35 P.S. §§ 1331.1 - 1331.9). SECTION M-102 INSPECTIONS AND TESTING M-102.1 Evaluation and follow-up inspection services. Prior to the approval of a prefabricated construction assembly having concealed work and the issuance of a permit, the code official shall require the submittal of an evaluation report from an approved agency on each prefabricated construction assembly. The report shall indicate the complete details of the mechanical system, including a description of the system and its components, the basis upon which the system is being evaluated, test results and similar information and other data as necessary for the code official to determine conformance to this code. Exception: Manufactured and Industrialized housing pursuant to Section A-102.12 of the Administrative Code. M-102.1.1 Follow-up inspection. Except where ready access is provided to mechanical systems, service equipment and accessories for complete inspection at the site without disassembly or dismantling, the code official shall conduct in-plant inspections to ensure conformance to the approved evaluation report or shall accept inspection reports from an approved independent inspection agency. The inspection agency shall furnish the code official with the follow-up inspection manual and a report of inspections upon request. The mechanical system shall have an identifying label permanently affixed to the system indicating that factory inspections have been performed. M-102.1.2 Test and inspection records. Required test and inspection records shall be available to the code official at all times during the fabrication of the mechanical system and the erection of the building; or such records as the code official designates shall be filed. M-102.2 Testing. Mechanical systems shall be tested as required in this code and in accordance with Sections M-102.2.1 through M-102.2.3. Tests shall be made by the permit holder after notifying the code official, who shall have the authority to observe the tests. M-102.2.1 New, altered, extended or repaired systems. New mechanical systems and parts of existing systems, which have been altered, extended, renovated or repaired, shall be tested as prescribed herein to disclose leaks and defects. M-102.2.2 Apparatus, instruments, material and labor for tests. Apparatus, instruments, material and labor required for testing a mechanical system or part thereof shall be furnished by the permit holder. M-102.2.3 Reinspection and testing. Where any work or mechanical system does not pass an initial test or inspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or system shall then be reinspected or re-tested and the results resubmitted to the code official as appropriate. * * * CHAPTER 3 GENERAL REGULATIONS * * * SECTION 307 CONDENSATE DISPOSAL * * * [Delete Section 307.2.1.1, and replace as follows:] M-307.2.1.1 Disposal into Clothes Washer Box. Condensate shall be permitted to discharge into a clothes washer box with dual drainage outlets with one outlet dedicated to the clothes washer discharge and one outlet dedicated to condensate discharge. Condensate shall also be permitted to discharge into a clothes washer box with a single drainage outlet where the inlet of the clothes washer box outlet is sized to accommodate both the clothes washer discharge and the condensate discharge. * * * CHAPTER 11 REFRIGERATION SECTION 1101 GENERAL * * * [Add Section M-1101.2.1 as follows:] M-1101.2.1 Group A2L, A2, A3, and B1 high-probability equipment. High-probability equipment using Group A2L, A2, A3, or B1 refrigerant shall comply with UL 484, UL/CSA 60335-2-40, or UL/CSA 60335-2-89. * * * SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION * * * [Delete Table 1103.1 and replace as follows:] TABLE M-1103.1 REFRIGERANT CLASSIFICATION, AMOUNT, AND OEL Chemical Refrigerant | Formula | Chemical Name of Blend | Refrigerant Safety Group Classification | Amount of Refrigerant Per Occupied Space | [F] Degrees of Hazard a RCL | LFL f | OEL d Pounds per 1,000 cubic feet | ppm | g/m3 | Pounds per 1,000 cubic feet | ppm | g/m3 | ppm Chemical Refrigerant | Formula | Chemical Name of Blend | Refrigerant Safety Group Classification | Amount of Refrigerant Per Occupied Space | [F] Degrees of Hazard a RCL | LFL f | OEL d Pounds per 1,000 cubic feet | ppm | g/m3 | Pounds per 1,000 cubic feet | ppm | g/m3 | ppm R-11 c | CCI3F | trichlorofluoromethane | A1 | 0.39 | 1,100 | 6.1 | - | - | - | 1,000 | 2-0-0 b R-12 c | CCI2F2 | dichlorodifluoromethane | A1 | 5.6 | 18,000 | 90 | - | - | - | 1,000 | 2-0-0 b R-13 c | CCIF3 | chlorotrifluoromethane | A1 | - | - | - | - | - | - | 1,000 | 2-0-0 b R-13B1 c | CBrF3 | bromotrifluoromethane | A1 | - | - | - | - | - | - | 1,000 | 2-0-0 b * * * R-32 | CH2F2 | difluoromethane (methylene fluoride) | A2L | 0.8 | 36,000 | 77 | 19.1 | 144,000 | 306 | 1,000 | 1-4-0 * * * R-50 | CH4 | methane | A3 | - | - | - | - | 50,000 | - | 1,000 | - R-113 c | CCI2FCCIF2 | 1,1,2-trichloro-1,2,2- trifluoroethane | A1 | 1.2 | 2,600 | 20 | - | - | - | 1,000 | 2-0-0 b R-114 c | CCIF2CCIF2 | 1,2-dichloro-1,1,2,2- tetrafluoroethane | A1 | 8.7 | 20,000 | 140 | - | - | - | 1,000 | 2-0-0 b * * * R-141b | CH3CCI2F | 1,1,-dichloro-1- difluororethane | - | 0.78 | 2,600 | 12 | 17.8 | 60,000 | 287 | 500 | 2-1-0 R-142b | CH3CCIF2 | 1-chloro-1,1- difluoroethane | A2 | 5.1 | 20,000 | 82 | 20.4 | 80,000 | 329 | 1,000 | 2-4-0 R-143a | CH3CF3 | 1,1,1-trifluoroethane | A2L | 4.4 | 21,000 | 70 | 17.5 | 82,000 | 282 | 1,000 | 2-0-0 b R-152a | CH3CHF2 | 1,1-difluoroethane | A2 | 2.0 | 12,000 | 32 | 8.1 | 48,000 | 130 | 1,000 | 1-4-0 R-170 | CH3CH3 | ethane | A3 | 0.54 | 7,000 | 8.6 | 2.4 | 31,000 | 38 | 1,000 | 2-4-0 R-E170 | CH3OCH3 | Methoxymethane (dimethyl ether) | A3 | 1.0 | 8,500 | 16 | 4 | 34,000 | 64 | 1,000 | - * * * R-290 | CH3CH2CH3 | propane | A3 | 0.59 | 5,300 | 9.5 | 2.4 | 21,000 | 38 | 1,000 | 2-4-0 R-C318 | (CF2)4 | octafluorocyclobutane | A1 | 41 | 80,000 | 650 | - | - | - | 1,000 | - R-400 c | zeotrope | R-12/114 (50.0/50.0) | A1 | 10 | 28,000 | 160 | - | - | - | 1,000 | 2-0-0 b R-400 c | zeotrope | R-12/114 (60.0/40.0) | A1 | 11 | 30,000 | 170 | - | - | - | 1,000 | - * * * R-403B | zeotrope | R-290/22/218 (5.0/56.0/39.0) | A1 | 18 | 68,000 | 290 | - | - | - | 1,000 | 2-0-0 b * * * R-406A | zeotrope | R-22/600a/142b (55.0/4.0/41.0) | A2 | 4.7 | 21,000 | 75 | 18.8 | 82,000 | 301.9 | 1,000 | - * * * R-408A | zeotrope | R-125/143a/22 (7.0/46.0/47.0) | A1 | 21 | 94,000 | 330 | - | - | - | 1,000 | 2-0-0 b * * * R-411A | zeotrope | R-127/22/152a (1.5/87.5/11.0) | A2 | 2.9 | 14,000 | 46 | 11.6 f | 55,000 f | 185.6 f | 970 | - R-411B | zeotrope | R-1270/22/152a (3.0/94.0/3.0) | A2 | 2.8 | 13,000 | 45 | 14.8 f | 70,000 f | 283.3 f | 940 | - R-412A | zeotrope | R-22/218/142b (70.0/5.0/25.0) | A2 | 5.1 | 22,000 | 82 | 20.5 f | 87,000 f | 328.6 f | 1,000 | - R-413A | zeotrope | R-218/134a/600a (9.0/88.0/3.0) | A2 | 5.8 | 22,000 | 93 | 23.4 f | 88,000 f | 376.9 f | 1,000 | - * * * R-415A | zeotrope | R-22/152a (82.0/18.0) | A2 | 2.9 | 14,000 | 47 | 11.7 g | 56,000 g | 187.9 g | 1,000 | - R-415B | zeotrope | R-22/152a (25.0/75.0) | A2 | 2.1 | 12,000 | 34 | 8.4 | 47,000 | 135.1 | 1,000 | - * * * R-417A | zeotrope | R-125/134a/600 (46.6/50.0/3.4) | A1 | 3.5 | 13,000 | 55 | - | - | - | 1,000 | 2-0-0 b R-417B | zeotrope | R-125/134a/600 (79.0/18.3/2.7) | A1 | 4.3 | 15,000 | 69 | - | - | - | 1,000 | - R-418A | zeotrope | R-290/22/152a (1.5/96.0/2.5) | A2 | 4.8 | 22,000 | 77 | 19.2 g | 89,000 g | 308.4 g | 1,000 | - R-419A | zeotrope | R-125/134a/E170 (77.0/19.0/4.0) | A2 | 4.2 | 15,000 | 67 | 16.7 g | 60,000 g | 268.6 g | 1,000 | - R-419B | zeotrope | R-125/134a/E170 (48.5/48.0/3.5) | A2 | 4.6 | 17,000 | 74 | 18.5 g | 69,000 g | 297.3 g | 1,000 | - R-420A | zeotrope | R-134a/142b (88.0/12.0) | A1 | 12 | 44,000 | 180 | - | - | - | 1,000 | 2-0-0 b * * * R-423A | zeotrope | R-134a/227ea (52.5/47.5) | A1 | 19 | 59,000 | 300 | - | - | - | 1,000 | 2-0-0 b * * * R-429A | zeotrope | R-E170/152a/600a (60.0/10.0/30.0) | A3 | 0.81 | 6,300 | 13 | 3.2 | 25,000 | 83.8 | 1,000 | - R-430A | zeotrope | R-152a/600a (76.0/24.0) | A3 | 1.3 | 8,000 | 21 | 5.2 | 32,000 | 44 | 1,000 | - R-431A | zeotrope | R-290/152a (71.0/29.0) | A3 | 0.68 | 5,500 | 11 | 2.7 | 22,000 | 38.6 | 1,000 | - R-432A | zeotrope | R-1270/E170 (80.0/20.0) | A3 | 0.13 | 1,200 | 2.1 | 2.4 | 22,000 | 39.2 | 550 | - R-433A | zeotrope | R-1270/290 (30.0/70.0) | A3 | 0.34 | 3,100 | 5.5 | 2.4 | 20,000 | 32.4 | 760 | - R-433B | zeotrope | R-1270/290 (5.0-95.0) | A3 | 0.39 | 3,500 | 6.3 | 2.0 | 18,000 | 32.1 | 950 | - R-433C | zeotrope | R-1270/290 (25.0-75.0) | A3 | 0.41 | 3,600 | 6.5 | 2.0 | 18,000 | 83.8 | 790 | - * * * R-435A | zeotrope | R-E170/152a (80.0/20.0) | A3 | 1.1 | 8,500 | 17 | 4.3 | 34,000 | 68.2 | 1,000 | - R-436A | zeotrope | R-290/600a (56.0/44.0) | A3 | 0.5 | 4,000 | 8.1 | 2.0 | 16,000 | 32.3 | 1,000 | - R-436B | zeotrope | R-290/600a (52.0/48.0) | A3 | 0.51 | 4,000 | 8.1 | 2.0 | 16,000 | 32.7 | 1,000 | - * * * R-439A | zeotrope | R-32/125/600a (50.0/47.0/3.0) | A2 | 4.7 | 26,000 | 76 | 18.9 | 104,000 | 303.3 | 990 | - R-440A | zeotrope | R-290/134a/152a (0.6/1.6/97.8) | A2 | 1.9 | 12,000 | 31 | 7.8h | 46,000 h | 124.7 h | 1,000 | - R-441A | zeotrope | R-170/290/600a/600 (3.1/54.8/6.0/36.1) | A3 | 0.39 | 3,200 | 6.3 | 2.0 | 16,000 | 31.7 | 1,000 | - * * * R-443A | zeotrope | R-1270/290/600a (55.0/40.0/5.0) | A3 | 0.19 | 1,700 | 3.1 | 2.2 | 20,000 | 35.6 | 580 | - R-444A | zeotrope | R-32/152a/1234ze(E) (12.0/5.0/83.0) | A2L | 5.0 | 21,000 | 80 | 19.9 | 82,000 | 319.4 | 850 | - R-444B | zeotrope | R-32/152a/1234ze(E) (41.5/10.0/48.5) | A2L | 4.3 | 23,000 | 69 | 17.3 | 93,000 | 277.3 | 890 | - R-445A | zeotrope | R-744/134a/1234ze(E) (6.0/9.0/85.0) | A2L | 4.2 | 16,000 | 67 | 2.7 | 63,000 | 347.4 | 930 | - R-446A | zeotrope | R-32/1234ze(E)/600 (68.0/29.0/3.0) | A2L | 2.5 | 16,000 | 39 | 13.5 | 62,000 | 217.4 | 930 | - R-447A | zeotrope | R-32/125/1234ze(E) (68.0/3.5/28.5) | A2L | 2.6 | 16,000 | 42 | 18.9 | 65,000 | 303.5 | 900 | - R-447B | zeotrope | R-32/125/1234ze(E) (68.0/8.0/24.0) | A2L | 2.6 | 16,000 | 42 | 19.5 | 121,000 | 312.7 | 970 | - * * * R-451A | zeotrope | R-1234yf/134a (89.8/10.2) | A2L | 5.0 | 18,000 | 81 | 20.3 | 70,000 | 326.6 | 520 | - R-451B | zeotrope | R-1234yf/134a (88.8/11.2) | A2L | 5.0 | 18,000 | 81 | 20.3 | 70,000 | 326.6 | 530 | - * * * R-452B | zeotrope | R-32/125/1234yf (67.0/7.0/26.0) | A2L | 4.8 | 30,000 | 77 | 19.3 | 119,000 | 310.5 | 780 | - * * * R-454A | zeotrope | R-32/1234yf (35.0/65.0) | A2L | 3.2 | 16,000 | 52 | 18.3 | 63,000 | 293.9 | 690 | - R-454B | zeotrope | R-32/1234yf (68.9/31.1) | A2L | 3.1 | 19,000 | 49 | 22 | 77,000 | 352.6 | 850 | - R-454C | zeotrope | R-32/1234yf (21.5/78.5) | A2L | 4.4 | 19,000 | 71 | 18 | 62,000 | 289.5 | 620 | - R-455A | zeotrope | R-744/32/1234yf (3.0/21.5/75.5) | A2L | 4.9 | 22,000 | 79 | 26.9 | 118,000 | 432.1 | 650 | - * * * R-457A | zeotrope | R-32/1234yf/152a (18.0/70.0/12.0) | A2L | 3.4 | 15,000 | 54 | 13.5 | 60,000 | 216.3 | 650 | - * * * R-459A | zeotrope | R-32/1234yf/1234ze(E) (68.0/26.0/6.0) | A2L | 4.3 | 27,000 | 69 | 17.4 | 107,000 | 278.7 | 870 | - R-459B | zeotrope | R-32/1234yf/1234ze(E) (21.0/69.0/10.0) | A2L | 5.8 | 16,000 | 92 | 23.3 | 99,000 | 373.5 | 640 | - * * * R-462A | zeotrope | R-32/125/143a/134a/600 (9.0/42.0/2.0/44.0/3.0) | A2 | 3.9 | 16,000 | 62 | 16.6 f | 105,000 f | 265.8 f | 1,000 | - * * * R-500 c | zeotrope | R-12/152a (73.8/26.2) | A1 | 7.4 | 29,000 | 120 | - | - | - | 1,000 | 2-0-0 b R-501 c | zeotrope | R-22/12 (75.0/25.0) | A1 | 13 | 54,000 | 210 | - | - | - | 1,000 | - R-502 c | zeotrope | R-22/115 (48.8/51.2) | A1 | 21 | 73,000 | 330 | - | - | - | 1,000 | 2-0-0 b R-503 c | zeotrope | R-23/13 (40.1/59.9) | - | - | - | - | - | - | - | 1,000 | 2-0-0 b R-504 c | zeotrope | R-32/115 (48.2/51.8) | - | 28 | 140,000 | 450 | - | - | - | 1,000 | - * * * R-507A | zeotrope | R-125/143a (50.0/50.0) | A1 | 32 | 130,000 | 510 | - | - | - | 1,000 | 2-0-0 b * * * R-509A | zeotrope | R-22/218 (44.0/56.0) | A1 | 24 | 75,000 | 380 | - | - | - | 1,000 | 2-0-0 b R-510A | zeotrope | R-E170/600a (88.0/12.0) | A3 | 0.87 | 7,300 | 14 | 3.5 | 29,000 | 56.1 | 1,000 | - R-511A | zeotrope | R-290/E170 (95.0/5.0) | A3 | 0.59 | 5,300 | 9.5 | 2.4 | 21,000 | 38 | 1,000 | - R-512A | azeotrope | R-134a/152a (5.0/95.0) | A2 | 1.9 | 11,000 | 31 | 7.7 | 45,000 | 123.9 | 1,000 | - * * * R-516A | azeotrope | R-1234yf/134a/152a (77.5/8.5/14.0) | A2 | 3.2 | 13,000 | 52 | 13.1 | 50,000 | 210.1 | 590 | - R-600 | CH3CH2CH2CH3 | butane | A3 | 0.15 | 1,000 | 2.4 | 3.0 | 20,000 | 48 | 1,000 | 1-4-0 R-600A | CH(CH3)2CH3 | 2-methylpropane (isobutane) | A3 | 0.59 | 4,000 | 9.5 | 2.4 | 16,000 | 38 | 1,000 | 2-4-0 R-601 | CH2CH2CH2CH2CH3 | pentane | A3 | 0.18 | 1,000 | 2.9 | 2.2 | 12,000 | 35 | 600 | - R-601A | (CH3)2CHCH2 CH3 | 2-methylbutane (isopentane) | A3 | 0.18 | 1,000 | 2.9 | 2.4 | 13,000 | 38 | 600 | - * * * R-744 | CO2 | carbon dioxide | A1 | 3.4 | 30,000 | 54 | - | - | - | 5,000 | 2-0-0 R-1130(E) | CHCI=CHCI | trans-1,2-dichloroethene | B2 | 0.25 | 1,000 | 4.0 | 16 | 65,000 | 258 | 200 | - R-1132A | CF2=CH2 | 1,1-difluoroethene | A2 | 2.0 | 13,000 | 33 | 8.1 | 50,000 | 131 | 500 | - R-1150 | CH2=CH2 | ethene (ethylene) | B3 | - | - | - | 2.2 | 31,000 | 36 | 200 | 1-4-2 * * * R-1234yf | CF3CH=CH2 | 2,3,3,3-tetrafluoro-1- propene | A2L | 4.5 | 16,000 | 75 | 18 | 62,000 | 289 | 500 | - R-1234ze(E) | CF3CH=CFH | trans-1,3,3,3-tetrafluoro- 1-propene | A2L | 4.7 | 16,000 | 76 | 18.8 | 65,000 | 303 | 800 | - * * * R-1336mzz (Z) | CF3CHCHCF3 | cis-1,1,1,4,4,4- hexaflouro-2-butene | A1 | 5.2 | 13000 | 84 | - | - | - | 500 | - | | | | | | | | | | | For SI: 1 pound = 0.454 kg, 1 cubic foot = 0.0283 m3. a. Degrees of hazard are for health, fire, and reactivity, respectively, in accordance with NFPA 704. b. Reduction to 1-0-0 is allowed if analysis satisfactory to the code official shows that the maximum concentration for a rupture or full loss of refrigerant charge would not exceed the IDLH, considering both the refrigerant quantity and room volume. c. Class I ozone depleting substance; prohibited for new installations d. Occupational Exposure Limit based on the OSHA PEL, ACGIH TLV-TWA, the TERA WEEL or consistent value on a time-weighed average (TWA) basis (unless noted C for ceiling) for an 8 hr/d and 40 hr/wk. e. LFL is based on the Worst Case of Formulation for Flammability (WCF) @ 73.4°F (23°C) unless otherwise noted. f. Worst Case of Fractionation for Flammability (WCFF) LFL @ 140°F (60°C). g. WCFF LFL @ 73.4°F (23°C) h. WCF LFL @ 212°F (100°C). * * * SECTION 1104 SYSTEM APPLICATION REQUIREMENTS * * * [Delete Section 1104.3.1 and replace as follows:] M-1104.3.1 Air Conditioning for human comfort. High-probability systems used for human comfort shall use Group A1 and A2L refrigerant. Exceptions: 1. Equipment listed for and used in residential occupancies containing a maximum of 6.6 pounds (3 kg) of refrigerant. 2. Equipment listed for and used in commercial occupancies containing a maximum of 22 pounds (10 kg) of refrigerant. 3. Industrial occupancies. [Delete Section 1104.3.2 and replace as follows:] M-1104.3.2 Group A2, A3, and B3 refrigerants. Group A2 and B2 refrigerants shall not be used in high probability systems. Group A3 and B3 shall not be used except where approved. Exceptions: This section does not apply to: 1. Laboratories where the floor areas per occupant is not less than 100 square feet (9.3 m 2 ). 2. Listed self-contained systems having a maximum of 0.331 pounds (150 G) of Group A3 refrigerant. 3. Industrial Occupancies. 4. Equipment listed for and used in residential occupancies containing a maximum of 6.6 pounds (3 kg) of Group A2 or B2 refrigerant. 5. Equipment listed for and used in commercial occupancies containing a maximum of 22 pounds (10 kg) of Group A2 or B2 refrigerant. [Delete Table 1104.3.2 in its entirety, without substitution.] * * * SECTION 1106 MACHINERY ROOMS, GENERAL REQUIREMENTS * * * [Delete Section 1106.3 and replace as follows:] M-1106.3 Class 2 and Class 3 refrigerants. Where refrigerants of Groups A2, A3 and B3 are used, the machinery room shall conform to the Class 1. Division 2, hazardous location classification requirements of NFPA 70. * * * [Delete Section 1106.4 in its entirety, including Table 1106.4.2, and replace as follows:] M-1106.4 Group A2L and B2L Refrigerant. Machinery rooms for Group A2L and B2L refrigerant shall comply with Sections 1106.4. through Section 1106.4.3. M-1106.4.1 Elevated Temperatures. Open flame-producing devices or continuously operating hot surfaces over 1290°F (700°C) shall not be permanently installed in the room. M-1106.4.2 Refrigerant detector. In addition to the requirements of Section 1105.3, refrigerant detectors shall signal an alarm and activate the ventilation system in accordance with the response time specified in Table 1106.4.2. Table M-1106.4.2 Group A2L and B2l Detector Activation Activation Level | Maximum Response Time (seconds) | ASHRAE 15 Ventilation Level | Alarm Reset | Alarm Type Less than or equal to the OEL in Table 1103.1 | 300 | 1 | Automatic | Trouble Less than or equal to the refrigerant concentration level in Table 1103.1 | 15 | 2 | Manual | Emergency M-1106.4.3 Mechanical Ventilation. The machinery room shall have a mechanical ventilation system complying with ASHRAE 15. * * * SECTION 1107 PIPING MATERIAL * * * [Delete Table 1107.4 and replace as follows:] TABLE M-1107.4 REFRIGERANT PIPE PIPING MATERIAL | STANDARD Aluminum tube | ASTM B210/ASTM B210M, ASTM B491M Brass (copper alloy) pipe | ASTM B43 Copper linesets | ASTM B280, ASTM B1003 Copper pipe | ASTM B42, ASTM B302 Copper tube a | ASTM B68, ASTM B75, ASTM B88, ASTM B280, ASTM B819 Steel pipe b | ASTM A53, ASTM A106, ASTM A333 Steel tube | ASTM A254, ASTM A334 | a. Soft annealed copper tubing larger than 1 3/8-inch (35 mm) O.D. shall not be used for field assembled refrigerant piping unless it is protected from mechanical damage. b. ASTM A53, Type F steel pipe shall only permitted for discharge lines in pressure relief systems. * * * [Delate Table 1107.5 and replace as follows:] TABLE M-1107.5 REFRIGERANT PIPE FITTINGS FITTING MATERIAL | STANDARD Aluminum | ASTM B361 Copper and Copper Alloy (Brass) | ASME B16.15, ASME B16.18, ASME B16.22, ASME B16.24, ASME B16.26, ASME B16.50 Steel | ASTM A105, ASTM A181, ASTM A193, ASTM A234, ASTM A420, ASTM A707 * * * [Delete Section 1107.7 and replace as follows:] M-1107.7 Flexible connectors, expansion and vibration compensators. Flexible connectors and expansion and vibration control devices shall be listed and labeled for use in refrigerant systems and pressures for which the components are installed. * * * SECTION 1109 REFRIGERANT PIPE INSTALLATION * * * [Delete Section 1109.2.2 and replace as follows:] M-1109.2.2 Refrigerant and pipe enclosure. Refrigerant piping shall be protected by locating it within the building elements or within protective enclosures. Exception: Piping protection within the building elements or protective enclosure shall not be required in any of the following locations: 1. Where installed without ready access or located more than 7 feet 3 inches (2210 mm) above the finished floor. 2. Where located within 6 feet (1829 mm) of the refrigerant unit or appliance. 3. Where located in a machinery room complying with Section 1105. 4. Outside the building: 4.1. Protected from damage from the weather, including but not limited to, hail, ice, and snow loads and 4.2. Protected from damage within the expected foot or traffic path or 4.3 Outside, underground, installed not less than 8 inches (200 mm) below finished grade and protected against corrosion. [Delete Section 1109.2.3 and replace as follows:] M-1109.2.3 Prohibited Locations. Refrigerant piping shall not be installed in any of the following locations: 1. Exposed within a fire resistance-rated exit access corridor. 2. Exposed within an interior exit stairway. 3. Within an interior exit ramp. 4. Within an exit passageway. 5. Within an elevator, dumbwaiter or other shaft containing a moving object. * * * [Delete Section 1109.2.5 and replace as follows:] M-1109.2.5 Refrigerant pipe shafts. Refrigerant piping that penetrates two or more floor/ceiling assemblies shall be enclosed in a fire-resistance-rated shaft enclosure. The fire-resistance-rated shaft enclosure shall comply with Section 713 of the International Building Code. Exceptions: 1. Refrigeration systems using R-718 refrigerant (water). 2. Piping in a direct refrigeration system where the refrigerant quantity does not exceed the limits of Table 1103.1 for the smallest occupied space through which the piping passes. 3. Piping located on the exterior of the building where vented to the outdoors. * * * [Delete Section 1109.2.6 and replace as follows:] M-1109.2.6 Exposed piping surface temperature. Exposed piping with ready access to nonauthorized personnel having surface temperatures greater than 120°F (69°C) or less than 5°F (-15°C) shall be protected from contact or shall have thermal insulation that limits the exposed insulation surface temperature to a range of 5°F (-15°C) to 120°F (69°C). * * * [Delete Section 1109.2.7 and replace as follows:] M-1109.2.7 Pipe identification. Refrigeration pipe located in areas other than the room or space where the refrigerating equipment is located shall be identified. The pipe identification shall be located at intervals not exceeding 20 feet (6096 mm) on the refrigerant piping or pipe insulation. The minimum height of lettering of the identification label shall be 1/2 inch (12.7 mm). The identification shall indicate the refrigerant designation and safety group classification of refrigerant used in the piping system. For Group A2L and B2L refrigerants, the identification shall also include the following statement: “WARNING - Risk of Fire. Flammable Refrigerant.” For Group A2, A3, B2 and B3 refrigerants, the identification shall also include the following statement: “DANGER - Risk of Fire or Explosion. Flammable Refrigerant.” For any Group B refrigerant, the identification shall also include the following statement: “DANGER - Toxic Refrigerant.” * * * [Delete Section 1109.3 and replace as follows, but leave Table 10.9.3.2 unchanged:] M-1109.3 Installation requirements for Group A2L, A2, A3, B2L, B2, or B3 refrigerant. Piping systems using Group A2L, A2, A3, B2L, B2, or B3 refrigerant shall comply with the requirements of Section 1109.3.1 and 1109.3.2. M-1109.3.1 Pipe Protection. In addition to the requirements of Section 305.5, aluminum, copper, and steel tube used for Group A2, A3, B2L, B2, and B3 refrigerants and located in concealed locations where tubing is installed in studs, joists, rafters or similar member spaces, and located less than 1-1/2 inches (38 mm) from the nearest edge of the member, shall be continuously protected by shield plates. Protective steel shield plates having a minimum thickness of 0.0575 inch (1.46 mm) (No. 16 gage) shall cover the area of the tube plus the areas extending not less than 2 inches (51 mm) beyond both sides of the tube. M-1109.3.2 Shaft ventilation. Refrigerant pipe shafts with systems using Group A2L or B2L refrigerant shall be naturally or mechanically ventilated. Refrigerant pipe shafts with one or more systems using any Group A2, A3, B2, or B3 refrigerant shall be continuously mechanically ventilated and shall include a refrigerant detector. The shaft ventilation exhaust outlet shall comply with Section 501.3.1. Naturally ventilated shafts shall have a pipe, duct or conduit not less than 4 inches (102 mm) in diameter that connects to the lowest point of the shaft and extends to the outdoors. The pipe, duct or conduit shall be level or pitched downward to the outdoors. Mechanically ventilated shafts shall have a minimum airflow velocity in accordance with Table 1109.3.2. The mechanical ventilation shall be continuously operated or activated by a refrigerator. Systems utilizing a refrigerant detector shall activate the mechanical ventilation at a maximum refrigerant concentration of 25 percent of the lower flammable limit of the refrigerant. The detector, or a sampling tube that draws air to the detector, shall be located in an area where refrigerant from a leak will concentrate. The shaft shall not be required to be ventilated for double-wall refrigerant pipe where the interstitial space of the double-wall pipe is vented to the outdoors. * * * [Delete Section 1109.4 in its entirety, without substitution] * * * [Delete Section 1109.7 in its entirety, without substitution] * * * SECTION 1110 REFRIGERATION PIPING SYSTEM TEST * * * [Delete Section 1110.3 and replace as follows:] M-1110.3 Test gases. The medium used for pressure testing the refrigerant system shall be one of the following inert gases: oxygen-free nitrogen, helium, argon or premixed nonflammable oxygen-free nitrogen with a tracer of gas of hydrogen or helium. For R-744 refrigerant systems, carbon dioxide shall be allowed as the test medium, For R-718 refrigerant systems, water shall be allowed as the test medium. M-1110.3.1 Test gases not permitted. Oxygen, air, refrigerants other than those identified in Section 1110.3, combustible gases and mixtures containing such gases shall not be used as the pressure test medium. * * * [Delete Section 1110.5 and replace as follows:] M-1110.5 Piping system strength test. Refrigerating system components and refrigerant piping shall be tested in accordance with ASME B31.5 or this section. Separate tests for isolated portions of the system are permitted and provided that all required portions are tested at least once. Pressurize with test gas for a minimum of 10 minutes to not less than the lower of (a) the lowest design pressure for any system component, or (b) the lowest value of set pressure for any pressure relief devices in the system. The design pressures for determination of test pressure shall be the pressure identified on the label nameplate of the condensing unit, compressor, compressor unit, pressure vessel, or other system component with a nameplate. A passing test result shall have no rupture or structural failure of any system component or refrigerant piping. Refrigerant popping and tubing greater than 3/4 inches in diameter shall be tested in accordance with ASHRAE 15. [Delete Section 1110.6 in its entirety, without substitution] [Delete Section 1110.7 in its entirety, without substitution] * * * CHAPTER 15 REFERENCED STANDARDS * * * [Add ASHRAE reference as follows:] ASHRAE | ASHRAE 1791 Tullie Circle NE Atlanta, GA 30329 15-2022 | Safety Standard for Refrigeration Systems 34-2022 | Designation and Safety Classification of Refrigerants * * * [Add ASTM reference as follows:] ASTM | ASTM International 100 Bar Harbor Drive, P.O. Box C700 West Conshohocken, PA A333-18 | Standard Specification for Seamless and Welded Steel Pipe for Low-Temperature Service and other Applications with required Notch Toughness * * * [Add UL reference as follows:] UL | | UL, LLC 333 Pfingsten Road, Northbrook, IL 60062-2096 UL/CSA 60335-2-40 | 2022 | Household and Similar Electrical Appliances—Safety—Part 2-40: Particular Requirements for Electrical Heat Pumps, Air Conditioners and Dehumidifiers UL/CSA 60335-2-89 | 2021 | Household and Similar Electrical Appliances—Safety—Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor * * * SUBCODE "P" (THE PHILADELPHIA PLUMBING CODE) Article P-1.0 Pursuant to the Pennsylvania Uniform Construction Code Act, adoption of the “2021 International Plumbing Code” with local amendments which legally existed prior to the Act and newly proposed amendments. § P-1.1 The “2021 International Plumbing Code” as published by the International Code Council is hereby adopted as the Philadelphia Plumbing Code, with amendments as set forth in § P-1.2. Editor's note: The 2021 International Plumbing Code, as revised by Philadelphia, can be found at: https://codes.iccsafe.org/content/IPC2021P1 § P-1.2 The “2021 International Plumbing Code”, copies of which are on file with the Department of Licenses and Inspections, is incorporated as if fully set forth herein, subject to the following local amendments. § P-1.2.1 Italics indicates matter added. Strikethrough indicates matter deleted. Deletions of large blocks of material are noted in [brackets]. § P-1.2.2 The numbers of all local amendments shall be preceded with the prefix “P-”. § P-1.2.3 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. § P-1.2.4 The Department of Licenses and Inspections is authorized to publish a “Philadelphia Plumbing Code” (subject to applicable copyright laws) fully incorporating these amendments and any associated graphics that provide guidance on the application of this code. § P-1.2.5 THE 2021 INTERNATIONAL PLUMBING CODE: [History: Added, Bill No. 960589 (approved March 19, 1997). This Subcode "P" repealed and replaced in its entirety previous Title 8, which was based on Bill No. 891 (approved February 17, 1995), 1995 Ordinances, p. 91, as amended. This Subcode "P" was repealed and replaced in its entirety by Bill No. 190455 (approved July 24, 2019). Section 2 of Bill No. 190455 provides: "The provisions of this Ordinance are subject to review under the Pennsylvania Construction Code Act (Act 45 of 1999, P.L. 491, as amended) and shall become effective October 1, 2019, or upon resolution of any challenge that is filed with the Secretary of the Pennsylvania Department of Labor and Industry pursuant to the requirements of Section 503 of Act 45 of 1999, as amended (35 P.S. sec. 7210.503), if the challenge is resolved after that date. The Commissioner of the Department of Licenses and Inspections shall provide written certification to the Chief Clerk within ten days of the filing of any challenge, and further such certification regarding the resolution of any challenge." Repealed and replaced, Bill No. 250645 (approved June 12, 2026).] CHAPTER 1 SCOPE AND ADMINISTRATION [Delete the contents of this Chapter and substitute the following:] SECTION P-101 GENERAL P-101.1 Title. These provisions together with those provisions of the International Plumbing Code which are not hereby amended shall be known as the “Philadelphia Plumbing Code” or “this code”. P-101.2 Scope. The provisions of the Philadelphia Plumbing Code shall apply to the erection, installation, alteration, repairs, relocation, replacement, addition to, use or maintenance of plumbing systems within the City of Philadelphia. This code shall regulate nonflammable medical gas, inhalation anesthetic, vacuum piping, nonmedical oxygen systems and sanitary and condensate vacuum collection systems. The installation of fuel gas distribution piping and equipment, fuel-gas-fired water heaters and water heater venting systems shall be regulated by the Philadelphia Fuel Gas Code (Subcode G). Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures shall comply with this code. P-101.2.1 Jurisdiction outside of property lines. All plumbing systems within a structure or on a premises and extending to the curb line of the street shall be regulated by this code unless stated otherwise herein. Plumbing systems located beyond the curb line of the street and connecting to the public main or public sewer shall be regulated by the Philadelphia Water Department. P-101.3 Intent. The purpose of this code is to establish the minimum requirements to provide a reasonable level of safety, public health and general welfare by regulating and controlling the design, construction, installation, quality of materials, location, operation and maintenance or use of plumbing equipment and systems. P-101.4 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are as set forth in the Philadelphia Administrative Code (Subcode A). P-101.5 Appendices. The International Plumbing Code Appendix E is hereby adopted to provide acceptable methods for the sizing of water service and water distribution piping by a designer. SECTION P-102 INSPECTIONS AND TESTING P-102.1 Inspections. In addition to the inspections specified in Chapter 4 of the Administrative Code, the code official shall be authorized to make or require other inspections of any construction work to ascertain compliance with the provisions of this code and other laws that are enforced. P-102.1.1 Evaluation and follow-up inspection services. Prior to the approval of a closed, prefabricated plumbing system and the issuance of a plumbing permit, the code official shall require the submittal of an evaluation report on each prefabricated plumbing system indicating the complete details of the plumbing system, including a description of the system and its components, the basis on which the plumbing system is being evaluated, test results and similar information, and other data as necessary for the code official to determine conformance to this code. Exception: Manufactured housing pursuant to the Manufactured Housing Construction and Safety Standards Authorization Act (35 P.S. §§ 1656.1 - 1656.9) and industrialized housing and industrialized commercial buildings pursuant to the Industrialized Housing Act (35 P.S. §§ 1651.1 - 1651.12) respectively. P-102.1.1.1 Evaluation service. The code official shall consider the evaluation report of an approved Special Inspection Agency, registered in accordance with Section 9-1306 of The Philadelphia Code, for determining adequacy and conformance to this code. P-102.1.1.2 Follow-up inspection. Except where ready access is provided to all plumbing systems, service equipment and accessories for complete inspection at the site without disassembly or dismantling, the code official shall be authorized to accept the inspection reports of an independent, approved inspection agency to conduct such inspections. The inspection agency shall furnish the code official with the follow-up inspection manual and a report of inspections on request, and the plumbing system shall have an identifying label permanently affixed to the system indicating that factory inspections have been performed. P-102.1.1.3 Test and inspection records. Required test and inspection records shall be available to the code official at all times during the fabrication of the plumbing system and the erection of the building, or such records as the code official designates shall be filed. P-102.2 Special inspections. Special inspections of alternative engineered design plumbing systems shall be conducted in accordance with Sections P-102.2.1 and P-102.2.2. P-102.2.1 Periodic inspection. The registered design professional or designated inspector shall periodically inspect and observe the alternative engineered design to determine that the installation is in accordance with the approved construction documents. Discrepancies shall be brought to the immediate attention of the Registered Master Plumber for correction. Records shall be kept of all inspections. P-102.2.2 Written report. The registered design professional shall submit a final report in writing to the code official upon completion of the installation, certifying that the alternative engineered design conforms to the approved construction documents. A certificate of approval for the plumbing permit shall not be issued until this written certification has been submitted. P-102.3 Testing. Plumbing work and systems shall be tested as required in Section 312 and in accordance with Sections P-102.3.1 through P-102.3.3. Tests shall be made by the Registered Master Plumber or his designee and observed by the code official. P-102.3.1 New, altered, extended or repaired systems. New plumbing systems and parts of existing systems that have been altered, extended or repaired shall be tested as prescribed herein to disclose leaks and defects, except that testing is not required in the following cases: 1. In any case that does not include addition to, replacement, alteration or relocation of any water supply, drainage or vent piping. 2. In any case where plumbing equipment is set up temporarily for exhibition purposes. P-102.3.2 Equipment, material and labor for tests. Equipment, material and labor required for testing a plumbing system or part thereof shall be furnished by the Registered Master Plumber. P-102.3.3 Reinspection and testing. Where any work or installation does not pass any initial test or inspection, the necessary corrections shall be made to comply with this code. The work or installation shall then be resubmitted to the code official for inspection and testing. P-102.4 Approval. After the prescribed tests and inspections indicate that the work complies in all respects with this code, a certificate of approval shall be issued by the code official. P-102.5 Temporary connection. The code official shall have the authority to authorize the temporary connection of the building or system to the utility source for the purpose of testing plumbing systems or for use under a temporary certificate of occupancy. SECTION P-103 PERMITS AND LICENSES P-103.1 License required. No person shall install plumbing, water, drain or waste piping, or fixtures unless properly licensed pursuant to Title 9 Section 9-1003. P-103.1.1 Plumbing work by unlicensed persons. No person shall hire an unlicensed person to perform plumbing work requiring a plumbing permit. Any person who has had plumbing work performed by an unlicensed person must have a Registered Master Plumber inspect such work and, if necessary, correct the installation. Permits must be secured for the unlicensed work and associated inspection activity and for any additional plumbing work performed as a result of the inspection. P-103.2 Plumbing permits required. A plumbing permit is required to install, enlarge, alter, repair or replace any plumbing system, the installation of which is regulated by this code subject to the general permit exceptions of Section A-301.1 of the Administrative Code. Exceptions: 1. A plumbing permit shall not be required for the installation, alteration, enlargement, repair or replacement of special piping and storage systems regulated by Chapter 12 of this code. Such installations shall require a building permit except where subject to the exclusions or exemptions provided in the Administrative Code. 2. A plumbing permit shall not be required for the activities listed in Section A-301.2.4 of the Administrative Code. P-103.2.1 Water service and water distribution permits. A plumbing permit shall be required for the installation, repair or replacement of the water service distribution pipe located between the curb stop and the water distribution pipe of the structure. A permit from the Water Department shall be required for the installation, repair or replacement of the water service pipe from the curb stop to the public water main. P-103.2.2 Lateral permits. A permit from the Water Department shall be required for the installation, repair or replacement of laterals from the building (house) trap to the public sewer. P-103.3 Permit applications. Applications for plumbing permits shall be submitted in accordance with the Administrative Code. P-103.3.1 By whom application is made. The department shall accept plumbing permit applications from the owner or lessee of the building or structure, or agent of either; by the registered design professional employed in connection with the proposed work; by the Registered Master Plumber responsible for the work; or other licensed person authorized to apply for permits pursuant to the Philadelphia Administrative Code, so long as the Registered Master Plumber responsible for the work is identified and provides confirmation of responsibility prior to the issuance of the plumbing permit. P-103.4 Permit holder. The owner shall retain the right to change the Registered Master Plumber associated with a permit to a new Registered Master Plumber. The changing of plumbing contractors shall not require the issuance of a new permit, where the owner identifies a new Registered Master Plumber to complete the work under such plumbing permit. P-103.4.1 Multiple Registered Master Plumbers. The Department reserves the right to issue a single plumbing permit for work to be performed by multiple Registered Master Plumbers, provided that the owner is responsible for final compliance in the event of a dispute between the named Registered Master Plumbers. P-103.4.2 Responsibility. All Registered Master Plumbers identified on a permit shall be responsible for compliance with this code in the performance of their work. No other Registered Master Plumber shall perform work related to the permit except as a subcontractor or employee. SECTION P-104 TEMPORARY EQUIPMENT, SYSTEMS AND USES P-104.1 General. The code official is authorized to issue a plumbing permit for temporary equipment, systems and uses. Such permits shall be limited as to time of service but shall not be permitted for more than 180 days. The code official is authorized to grant extensions for demonstrated cause. P-104.2 Conformance. Temporary equipment, systems and uses shall conform to the accessibility and sanitary requirements of this code as necessary to ensure the public health, safety and general welfare. P-104.3 Temporary utilities. The code official is authorized to give permission to temporarily supply utilities before an installation has been fully completed and the final certificate of approval has been issued. P-104.4 Termination of approval. The code official is authorized to terminate such permit for temporary equipment, systems or uses and to order the temporary equipment, systems or uses to be discontinued. SECTION P-105 REGULATIONS P-105.1 Authorization. The Department is authorized to promulgate technical regulations, and to amend existing such regulations as it deems necessary or appropriate from time to time, governing the manner in which plumbing work is to be performed and the materials that are to be used. Such regulations shall meet the standards set forth in Section P-105.1.1. P-105.1.1 Standards of plumbing regulations. In developing or amending the technical regulations governing plumbing installations, the Department shall develop regulations based upon the model plumbing codes enacted through the Pennsylvania Uniform Construction Code, Act 45 of 1999, as amended (the “UCC”); to include: 1. The development of any necessary local exceptions to such model plumbing codes, provided that such amendments would equal or exceed the minimum requirements of the UCC and remain subject to the following standards imposed by the UCC: a. That certain clear and convincing local climatic, geologic, topographic or public health and safety circumstances or conditions justify the exception; b. the exception shall be adequate for the purpose intended and shall meet a standard of performance equal to or greater than that prescribed by the UCC; and c. the exception would not diminish or threaten the health, safety and welfare of the public. 2. National standards that eliminate to the greatest extent possible the use of lead in the installation of plumbing materials both to protect the soil from contamination and to meet the requirements of the Federal Reduction of Lead in Drinking Water Act. 3. National standards that allow for methods and materials which promote sustainability and conservation in the City’s built environment. 4. Regulations that allow for alterations to existing plumbing systems installed under prior or current plumbing codes and standards, pursuant to updated plumbing codes enacted by the UCC. P-105.2 Publishing of errata. When errors are found in the development and format of the technical provisions of this code after publication, the Department of Licenses and Inspections is authorized to publish errata to clarify and correct such errors. SECTION P-106 PLUMBING ADVISORY BOARD P-106.1 Establishment. The Plumbing Advisory Board is established in the Department of Licenses and Inspections, with such duties as may be determined by the Mayor by Executive Order. P-106.2 Composition. The Board shall consist of seven members appointed by the Mayor and shall be chaired by one such appointed member as designated by the Mayor. The Board shall consist of: four members who are registered master plumbers; one member who is a design professional licensed or registered in the Commonwealth of Pennsylvania experienced in the design of plumbing systems; one member who shall represent the development community; and one member who shall represent the sustainability community. The Board shall also include the following non-voting ex-officio members: one member from the Department of Licenses and Inspections; one member from the Street Department; and one member from the Water Department, each of whom shall be appointed by their respective Commissioners. In the event a vacancy occurs with one of the members appointed by the Mayor, the remainder of the Board may recommend a replacement. CHAPTER 2 DEFINITIONS * * * SECTION 202 GENERAL DEFINITIONS * * * APPRENTICE. A person registered as an apprentice plumber by the City of Philadelphia. * * * BACKFLOW. Pressure created by any means in the water distribution system, which by being in excess of the pressure in the water supply mains causes a potential backflow condition. Backpressure, low head. A pressure less than or equal to 4.33 psi (29.88 kPa) or the pressure exerted by a 10-foot (3048 mm) column of water. Backsiphonage. The backflow of potentially contaminated water into the potable water system as result of the pressure in the potable water system falling below atmospheric pressure of the plumbing fixtures, pools, tanks or vats connected to the potable water distribution piping. Water supply system. The flow of water or other liquids, mixtures or substances into the distribution pipes and water-supply pipes of a potable water supply from any source except the intended source. * * * BONA FIDE ADDRESS. A genuine and legitimate street address where the Master Plumber conducts his or her business and where he or she can be readily contacted by the Department via telephone, mail or messenger on all regular working days of the Department. * * * BUILDING (HOUSE) DRAIN. That part of the lowest piping of a drainage system that receives the discharge from soil, waste and other drainage pipes inside and that extends 30 inches (762 mm) 5 feet (1524 mm) in developed length of pipe beyond the exterior walls of the building and conveys the drainage to the building sewer. * * * BUILDING (HOUSE) TRAP. A device, fitting or assembly of fittings installed in the building drain to prevent circulation of air between the drainage system of the building and the building sewer. A running trap, with a single hub vent, installed in the building sewer to prevent circulation of gases between the drainage system of the building and the public sewer. * * * BUILDING SEWER. That part of the drainage system that extends from the end of the building drain and conveys the discharge to an public sewer, private sewer, individual sewage disposal system or a lateral. other point of disposal. Combined. A building sewer that conveys both sewage and storm water or other drainage. Sanitary. A building sewer that conveys sewage only. Storm. A building sewer that conveys storm water or other drainage, but not sewage. * * * DEAD END. A branch leading from a soil, waste or vent pipe; a building drain; or a building sewer, and terminating at a developed length of 2 feet (610 mm) or more by means of a plug, cap or other closed fittings. * * * DRY VENT. Any vent that does not carry water or water-borne wastes. * * * FRESH AIR INLET. A means for introducing fresh air into a building drainage system through a building (house) trap. * * * GRIDDED WATER DISTRIBUTION SUPPLY SYSTEM. A water distribution supply system where every water distribution supply pipe is interconnected so as to provide two or more paths to each fixture supply pipe. * * * JOURNEYMAN PLUMBER. A person who has obtained a Journeyman Plumber license from the City of Philadelphia. LATERAL. The piping from the public sewer to the building (house) trap which materials and installation are regulated by the Philadelphia Water Department. * * * MASTER PLUMBER. A person who has obtained a Master Plumber license from the City of Philadelphia. * * * MINOR REPAIRS. The repair of an existing plumbing fixture, including the replacement of faucets or valves or parts thereof with like material or material serving the same purpose; the clearance of stoppages; the stopping of leaks without replacement of water, drainage or vent piping; the relieving of frozen pipes; other minor replacements or repairs, not including changes in the piping to the fixtures or in drainage, vent or water-supply system, other than the aforementioned items, and not including the replacement of any plumbing fixture. Replacement or repair of hot water heaters and hydronic boilers is not considered minor repairs under this section. * * * PLENUM. An enclosed portion of the building structure, other than an occupiable space being conditioned, that is designed to allow air movement and thereby serve as part of the air distribution system. PLUMBER. A person registered and licensed to install plumbing. * * * PLUMBING SYSTEM. A system that includes the water distribution pipes; water-supply pipes; plumbing fixtures and traps; water-treating or water-using equipment; soil, waste and vent pipes; and building drains; in addition to their respective connections, devices and appurtenances within a structure or premises; and the water service water distribution pipe, building sewer and building storm sewer serving such structure or premises. * * * PRIVATE. In the classification of plumbing fixtures, “private” applies to fixtures in residences and apartments, and to fixtures in nonpublic toilet rooms of hotels and motels and similar installations in buildings where the plumbing fixtures are intended for utilization by a family or an individual that are not public. PRIVATE BUILDING SEWER. Any sanitary drainage or storm drainage sewer privately owned and maintained and not directly controlled by the City of Philadelphia. PRIVATE WATER DISTRIBUTION PIPE. The distribution pipe privately owned and maintained and not directly controlled by the City of Philadelphia. PUBLIC SEWER. A sewer main and associated sewer appurtenances owned by the City of Philadelphia and maintained by the Water Department. PUBLIC OR PUBLIC UTILIZATION. In the classification of plumbing fixtures, “public” applies to fixtures in general toilet rooms of schools, gymnasiums, hotels, airports, bus and railroad stations, public buildings, bars, public comfort stations, office buildings, stadiums, stores, restaurants and other installations where a number of fixtures are installed so that their utilization is similarly unrestricted with unrestricted exposure to walk-in traffic. * * * SLANT. An outlet connection, at the public sewer for receiving storm or sanitary waste from the lateral, which is regulated by the Philadelphia Water Department. * * * VERTICAL UPRIGHT. That portion of pipe that is outside of a building connecting a leader to a combination building drain or building storm sewer. * * * WASTE RECEPTOR. A floor sink, standpipe, hub drain, or floor drain or a mop/slop sink that receives the discharge of one or more indirect waste pipes. * * * WATER PIPE. Riser. A water supply pipe that extends one full story or more to convey water to branches or to a group of fixtures. Water distribution pipe. A The pipe within the structure or on the premises that conveys water from the water service pipe, or from the meter when the meter is at the structure, to the points of utilization. from the curb stop or curb line to the structure or through the meter pit to the first point of use if there is no structure. Water service pipe. The pipe from the water main or other source of potable water supply, or from the meter when the meter is at the public right of way, to the water distribution system of the building served. to the curb stop or curb line as regulated by Philadelphia Water Department Regulations. WATER SUPPLY SYSTEM. The water service pipe, the water distribution pipe, the water-supply pipes, and the necessary connecting pipes, fittings, control valves and all appurtenances in or adjacent to the structure or premises, tanks, water heaters, water filtering or treatment equipment, and all appurtenances forming part of the system for supplying water to plumbing fixtures or other water outlets on the premises. * * * CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL * * * P-301.3 Connections to drainage system. Plumbing fixtures, drains, appurtenances and appliances used to receive or discharge liquid waste or sewage shall be directly connected to the sanitary drainage system of the building or premises, in accordance with the requirements of this code. This section shall not be construed to prevent indirect waste systems required by Chapter 8. Exception: Bathtubs, showers, lavatories, clothes washers and laundry trays shall not be required to discharge to the sanitary drainage system where such fixtures discharge to an approved system in accordance with Chapters 13 and 14. * * * SECTION 304 RODENT PROOFING * * * P-304.3 Meter boxes. Meter boxes shall be constructed in such a manner that rodents are prevented from entering a structure by way of the water service pipes or water distribution pipe connecting the meter box and the structure. * * * SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS * * * P-305.4 Freezing. Water, soil and waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperatures unless adequate provision is made to protect such pipes from freezing by insulation or heat or both. Exterior water supply and water distribution system piping shall be installed not less than 36" minimum below grade to the top of the pipe. 6 inches (152 mm) below the frost line and not less than 12 inches (305 mm) below grade. Where water distribution pipe and water service pipe connect at the curb or curb stop, the piping shall be a minimum of 48" below grade to the top of the pipe. P-305.4.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be installed not less than [NUMBER] 36 inches (914 mm) below finished grade to the top of the pipe at the point of septic tank connection. Building sewers shall be installed not less than [NUMBER] 36 inches (914 mm) below grade to the top of pipe. * * * SECTION 306 TRENCHING, EXCAVATION AND BACKFILL * * * P-306.2.3 Soft load-bearing materials. If soft materials of poor load-bearing quality are found at the bottom of the trench, stabilization shall be achieved by overexcavating not less than two pipe diameters and backfilling to the installation level of the bottom of the pipe with fine gravel, crushed stone or a concrete foundation. The concrete foundation shall be bedded with sand tamped into place so as to provide uniform load-bearing support for the pipe between joints. When drainage is installed in filled or unstable ground, pipe shall be supported on concrete piers, seven feet apart, or a constant bed of concrete or clevis hangers attached to reinforcing rods in the concrete floor above the piping. * * * P-306.4 Tunneling. Where pipe is to be installed by tunneling, jacking or a combination of both, the pipe shall be protected from damage during installation and from subsequent uneven loading. Where earth tunnels are used, adequate supporting structures shall be provided to prevent future settling or caving. Tunneling shall be limited to only that required to clear the obstacle above. P-306.5 Shoring. Shoring shall be installed in ditches and trenches as per the Occupational Safety and Health Administration’s (OSHA) Excavation standards, 29 Code of Federal Regulations (CFR), Subpart P. * * * SECTION 308 PIPING SUPPORT * * * P-308.3 Materials. Hangers, anchors and supports shall support the piping and the contents of the piping. Hangers and strapping material shall be of approved material that will not promote galvanic action. * * * TABLE P-308.5 HANGER SPACING PIPING MATERIAL | MAXIMUM HORIZONTAL SPACING (feet) | MAXIMUM VERTICAL SPACING (feet) PIPING MATERIAL | MAXIMUM HORIZONTAL SPACING (feet) | MAXIMUM VERTICAL SPACING (feet) Acrylonitrile butadiene styrene (ABS) pipe | 4 c | 10 b Aluminum tubing | 10 | 15 Brass pipe | 10 | 10 Cast-iron pipe | 5 a | 15 Chlorinated polyvinyl chloride (CPVC) pipe and tubing, 1 inch and smaller | 3 | 10 b Chlorinated polyvinyl chloride (CPVC) pipe and tubing, 1-1/4 inches and larger | 4 c | 10 b Copper or copper-alloy pipe | 12 | 10 Copper or copper-alloy tubing, 1-1/4 inch diameter and smaller | 6 | 10 Copper or copper-alloy tubing, 1-1/2 inch diameter and larger | 10 | 10 Cross-linked polyethylene (PEX) pipe 1 inch and smaller | 2.67 (32 inches) | 10 b Cross-linked polyethylene (PEX) pipe 1-1/4 inch and larger | 4 c | 10 b Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX-AL-PEX) pipe | 2.67 (32 inches) | 4 Lead pipe | Continuous | 4 Polyethylene/aluminum/polyethylene (PE-AL-PE) pipe | 2.67 (32 inches) | 4 Polyethylene of raised temperature (PE-RT) pipe 1 inch and smaller | 2.67 (32 inches) | 10 b Polyethylene of raised temperature (PE-RT) pipe 1-1/4 inch and larger | 4 c | 10 b Polypropylene (PP) pipe or tubing 1 inch and smaller | 2.67 (32 inches) | 10 b Polypropylene (PP) pipe or tubing, 1-1/4 inches and larger | 4 c | 10 b Polyvinyl chloride (PVC) pipe | 4 c | 10 b Stainless steel drainage systems | 10 | 10 b Steel pipe | 12 | 15 | | For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet where 10-foot lengths of pipe are installed. b. For sizes 2 inches and smaller, a guide shall be installed midway between required vertical supports. Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe. c. The maximum horizontal spacing of hangers shall be decreased to 3 feet where temperatures exceed 120 degrees Fahrenheit. * * * SECTION 309 FLOOD HAZARD RESISTANCE * * * P-309.2 Flood hazard. For structures located in flood hazard areas, the following systems and equipment shall be located and installed as required by Section 1612 of the International Building Code. 1. Water service pipes Water distribution pipe. * * * SECTION 311 TOILET FACILITIES OF WORKERS P-311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to PSAI Z4.3 and Table P-311.1, provided there shall not be less than one water closet on every three floors. The owner and contractors are responsible to prevent any other places on or about the site from being used for toilet purposes. Temporary toilets shall only be utilized until such time as the building drain is installed and there is a concrete slab or permanent flooring to accommodate a water closet. It is the responsibility of the General Contractor to assure that construction of the main drain proceeds as rapidly as is reasonably possible. TABLE P-311.1 MINIMUM NUMBER OF TOILET FACILITIES NUMBER OF EMPLOYEES | MINIMUM NUMBER OF TOILET FACILITIES NUMBER OF EMPLOYEES | MINIMUM NUMBER OF TOILET FACILITIES If serviced once per week 1 - 10 | 1 11 - 20 | 2 21 - 30 | 3 31 - 40 | 4 Over 40 | 1 additional facility for each 10 additional employees If serviced more than once per week 1 - 15 | 1 16 - 35 | 2 36 - 55 | 3 56 - 75 | 4 76 - 95 | 5 Over 95 | 1 additional facility for each 20 additional employees | P-311.2 Removal. Portable and temporary water closet facilities shall be removed, and the site shall be cleaned upon completion of construction. SECTION 312 TESTS AND INSPECTIONS * * * P-312.2 Drainage and vent water test. A water test shall be applied to the drainage system either in its entirety or in sections. If tested in sections, not more than 30 feet in height on any one system shall be tested at any one time. If applied to the entire system, all openings in the piping shall be tightly closed, except the highest opening, and the system shall be filled with water to the point of overflow. If the system is tested in sections, each opening shall be tightly plugged (except the highest opening of the water) but no section (except the building (house) drain and its connected yard and area drains) shall be tested with less than a 10-foot (3048 mm) head of water. except the highest openings of the section under test, and each section shall be filled with water, but sections shall not be tested with less than a 10-foot (3048 mm) head of water. In testing successive sections above the building (house) drain, at least the upper 10 feet of the next preceding section shall be re-tested so that no joint or pipe in the building (except the building (house) drain and the uppermost 10 feet of the system) shall have been submitted to a test of less than a 10-foot head of water. The water shall be kept in the system or in the portion under test for at least 15 minutes before inspection starts; the system shall then be tight at all points. * * * P-312.6 Gravity sewer test. Gravity sewer tests shall consist of plugging the end of the building sewer at the curb line point of connection with the public sewer, filling the building sewer with water, testing with not less than a 10-foot (3048 mm) head of water and maintaining such pressure for 15 minutes. P-312.6.1 Separate test. The building (house) drain and yard area drains, including all piping to a height of 10 feet above the highest point of the building (house) drain, shall be tested separately. All traps, pipe fittings and joints shall be exposed to view when the test is made. Water shall be introduced into the system in the quantity deemed necessary by the Department. To be approved, the flow of water through the system shall be unobstructed, and there shall be no leakage through any pipe, joint, trap, or fitting and maintaining such pressure for 15 minutes. P-312.7 Forced sewer test. Forced sewer tests shall consist of plugging the end of the building sewer at the curb line point of connection with the public sewer and applying a pressure of 5 psi (34.5 kPa) greater than the pump rating, and maintaining such pressure for 15 minutes. * * * P-312.11 Completion of work. After tests have been made and approved by the inspector, covering, insulation, coating or painting of the drain, vent and water piping shall be permitted. Decals on soil, waste, and vent piping, and hot, cold and return water piping shall be installed every 10 feet on covered and uncovered lines. * * * SECTION 314 CONDENSATE DISPOSAL * * * 314.2 Evaporators and cooling coils. Condensate drain systems shall be provided for equipment and appliances containing evaporators or cooling coils. Condensate drain systems shall be designed, constructed and installed in accordance with Sections 314.2.1 through 314.2.5. 314.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Such piping shall maintain a horizontal slope in the direction of discharge of not less than one-eighth unit vertical in 12 units horizontal (1-percent slope). Condensate shall not discharge into a street, alley or other areas so as to cause a nuisance. 314.2.1.1 Condensate discharge. Condensate drains shall not directly connect to any plumbing drain, waste or vent pipe. Condensate drains shall not discharge into a plumbing fixture other than a floor sink, floor drain, trench drain, mop sink, hub drain, standpipe, utility sink or laundry sink. Condensate drain connections to a lavatory wye branch tailpiece or to a bathtub overflow pipe shall not be considered as discharging to a plumbing fixture. Except where discharging to grade outdoors, the point of discharge of condensate drains shall be located within the same occupancy, tenant space or dwelling unit as the source of the condensate. P-314.2.1.1 Disposal into clothes washer box. Condensate shall be permitted to discharge into a clothes washer box with dual drainage outlets with one outlet dedicated to the clothes washer discharge and one outlet dedicated to condensate discharge. Condensate shall also be permitted to discharge into a clothes washer box with a single drainage outlet where the inlet of the clothes washer box outlet is sized to accommodate both the clothes washer discharge and the condensate discharge. * * * CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS * * * SECTION 403 MINIMUM PLUMBING FACILITIES 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number as shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. * * * P-403.1.1 Fixture calculations. To determine the occupant load of each sex gender, the total occupant load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each sex gender in accordance with Table 403.1. Fractional numbers resulting from applying the fixture ratios of Table 403.1 shall be rounded up to the next whole number. For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number. Exceptions: 1. The total occupant load shall not be required to be divided in half where approved statistical data indicates a distribution of the sexes gender of other more than 50 percent of each sex a gender. 2. Where multiple-user facilities are designed to serve all genders, the minimum fixture count shall be calculated 100 percent, based on total occupant load. In such multiple-user facilities, each fixture type shall be in accordance with ICC A117.1 and each urinal that is provided shall be located in a stall. 3. Distribution of the sexes genders is not required where single-user water closets and bathing room fixtures are provided in accordance with Section 403.1.2. P-403.1.2 Single-user toilet and bathing room fixtures. The plumbing fixtures located in single-user toilet and bathing rooms, including family or assisted- use toilet and bathing rooms that are required by Section 1109.2.1 of the International Building Code, shall contribute toward the total number of required plumbing fixtures for a building or tenant space. Single-user toilet and bathing rooms, and family or assisted-use toilet rooms and bathing rooms shall be identified as being available for use by all persons regardless of sex gender. The total number of fixtures shall be permitted to be based on the required number of separate facilities or based on the aggregate of any combination of single-user or separate facilities. P-403.1.3 Lavatory distribution. Where two or more toilet rooms are provided for each sex gender, the required number of lavatories shall be distributed proportionately to the required number of water closets. P-403.2 Separate facilities. Where plumbing fixtures are required, separate gender-based facilities shall be provided for each sex. Exceptions: * * * 5. Separate facilities shall not be required to be designated by sex gender where single-user toilet rooms are provided in accordance with Section 403.1.2. 6. For occupancy classifications requiring the same number of water closets and lavatories for male and female under Table 403.1, Sseparate facilities shall not be required where rooms having both water closets and lavatory fixtures are designed for use by both sexes all genders and privacy for water closets is provided in accordance with Section 405.3.4. Urinals shall be located in an area visually separated from the remainder of the facility or each urinal that is provided shall be located in a stall not be permitted in facilities designed for use by all genders. P-403.2.1 Family or assisted-use toilet facilities serving as separate facilities. Where a building or tenant space requires a separate toilet facility for each sex gender and each toilet facility is required to have only one water closet, two family or assisted-use toilet facilities shall be permitted to serve as the required separate facilities. Family or assisted-use toilet facilities shall not be required to be identified for exclusive use by either sex gender as required by Section 403.4. * * * P-403.3.1 Access. The route to the public toilet facilities required by Section 403.3 shall not pass through kitchens, storage rooms or closets. Access to the required facilities shall be from within the building or from the exterior of the building. Routes shall comply with the accessibility requirements of the International Building Code. The public shall have access to the required toilet facilities at all times that the building is occupied. * * * P-403.5 Drinking fountain location. Drinking fountains shall not be required to be located in individual tenant spaces provided that public drinking fountains are located within a distance of travel of 500 feet (152 m) of the most remote location in the tenant space and not more than one story above or below the tenant space. Where the tenant space is in a covered or open mall, such distance shall not exceed 300 feet (91 m). Drinking fountains shall be located on an accessible route. * * * SECTION 404 ACCESSIBLE PLUMBING FACILITIES * * * P-404.3 Exposed pipes and surfaces. Water supply and drain pipes under accessible lavatories and sinks shall be covered or otherwise configured to protect against contact. Pipe coverings shall comply with ASME A112.18.9 or ASTM C1822. * * * SECTION 405 INSTALLATION OF FIXTURES * * * 405.3 Setting. Fixtures shall be set level and in proper alignment with reference to adjacent walls. * * * 405.3.4 Water closet compartment. Each water closet utilized by the public or employees shall occupy a separate compartment with walls or partitions and a door enclosing the fixtures to ensure privacy. * * * P-405.3.4.1 Water closet compartments serving all genders. Partitions and doors enclosing a water closet in a toilet room serving all genders shall extend from floor to ceiling to ensure privacy and safety. * * * SECTION 406 AUTOMATIC CLOTHES WASHERS * * * P-406.2 Waste connection. The waste from an automatic clothes washer shall discharge through an air break into a standpipe in accordance with Section 802.3.3 802.4.3 or into a laundry sink. The trap and fixture drain for an automatic clothes washer standpipe shall be not less than 2 inches (51 mm) in diameter. The fixture drain for the standpipe serving an automatic clothes washer shall connect to a 3-inch (76 mm) or larger diameter fixture branch or stack. Automatic clothes washers that discharge by gravity shall be permitted to drain to a waste receptor or an approved trench drain. * * * SECTION 410 DRINKING FOUNTAINS * * * P-410.6 Educational facilities. Structures or portions of structures used for educational occupancies shall be equipped with one drinking fountain for every 100 students or fraction thereof, based on the facility’s actual student enrollment. At least one fountain shall be on each occupied floor of the building, without regard to the number of students. Water dispensers may be substituted for not more than fifty percent (50%) of the required number of drinking fountains. Each drinking fountain shall include a filtered water supply with a filter meeting or exceeding NSF/ANSI 53 and 42 requirements and a filter change indicator in accordance with NSF/ANSI 53. * * * SECTION 412 FAUCETS AND FIXTURE FITTINGS * * * P-412.3 Individual shower valves. Individual shower and tub-shower combination valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1. Such valves shall be installed at the point of use. Shower control valves shall be rated for the minimum flow rate of the installed shower head. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer’s instructions to provide water at a temperature not to exceed 120°F (49°C). In-line thermostatic valves shall not be utilized for compliance with this section. P-412.4 Multiple (gang) showers. Multiple (gang) showers supplied with a single, tempered water supply pipe shall have the water supply for such showers controlled by an approved automatic temperature control mixing valve that conforms to ASSE 1069 or CSA B125.3, or each shower head shall be individually controlled by a balanced-pressure, thermostatic or combination balanced pressure/thermostatic valve that conforms to ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1 and that is installed at the point of use. Where a shower head is individually controlled, shower control valves shall be rated for the minimum flow rate of the installed shower head. Such valves shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer’s instructions to provide water at a temperature not to exceed 120°F (49°C). Access shall be provided to an ASSE 1069 or CSA B125.3 valve. SECTION 413 FLOOR AND TRENCH DRAINS * * * P-413.3 Size of floor drains and trench drains. Floor drains, emergency floor drains, and trench drains shall have a drain outlet not less than 2 3 inches (51 76 mm) in diameter. An adjustable repair coupling shall be permitted to connect underground piping to a floor drain or trench drain. Exception: Floor drains serving one and two-family dwellings shall have a drain outlet not less than 2 inches (51 mm). * * * SECTION 414 FLOOR SINKS P-414.1 Approval. Sanitary floor sinks shall conform to the requirements of ASME A112.6.7. An adjustable repair coupling shall be permitted to connect underground piping to a floor sink. * * * SECTION 419 LAVATORIES P-419.1 Approval. Lavatories shall conform to ASME A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, ASME A112.19.3/CSA B45.4 or CSA B45.5/IAPMO Z124. Group wash fixtures shall conform to the requirements of Section 402. For determining the number of lavatories required by Table 403.1, every 20 inches (508 mm) of rim space, including a faucet, shall be considered as one lavatory. The distance between the centerline of each faucet shall be no less than 20". * * * SECTION 421 SHOWERS * * * P-421.3 Shower waste outlet. Waste outlets serving showers shall be not less than 1-1/2 inches (38 mm) in diameter and, for other than waste outlets in bathtubs, shall have removable strainers not less than 3 inches (76 mm) in diameter with strainer openings not less than 1/4 inch (6.4 mm) in least dimension. Where each shower space is not provided with an individual waste outlet, the waste outlet shall be located and the floor pitched so that waste from one shower does not flow over the floor area serving another shower. Waste outlets shall be fastened to the waste pipe in an approved manner. Exception: A linear shower drain shall be permitted when sized and installed in accordance with the linear drain manufacturer. The area of any linear shower drain shall be a minimum of 7 square inches (4516 mm2). * * * SECTION 424 URINALS * * * P-424.3 Non-water urinal connection. The fixture drain for a non-water urinal shall independently connect to a branch drain that serves one or more lavatories, water closets or water-using fixtures with not less than one drainage fixture unit that discharges upstream of such non-water urinals. * * * SECTION 425 WATER CLOSETS * * * P-425.3 Water closet seats. Water closets shall be equipped with seats of smooth, nonabsorbent material. Seats of water closets provided for public or employee toilet facilities shall be of the hinged open-front elongated type. Integral water closet seats shall be of the same material as the fixture. Water closet seats shall be sized for the water closet bowl type. * * * CHAPTER 5 WATER HEATERS SECTION 501 GENERAL * * * P-501.9 Thermal expansion control. Where a storage water heater is supplied with cold water that passes through a check valve, pressure reducing valve or backflow preventer, a thermal expansion control device shall be connected to the water heater cold water supply pipe at a point that is downstream of all check valves, pressure reducing valves and backflow preventers. Thermal expansion tanks shall be sized in accordance with the tank manufacturer’s instructions and shall be sized such that the pressure in the water supply system shall not exceed that required by Section P-604.8. * * * SECTION 503 CONNECTIONS * * * P-503.3 Materials. All water heaters and water heating equipment shall have a minimum of 4 feet (1219 mm) of developed length of copper tubing or similar metallic piping material connecting directly to the inlet and outlet of the unit. * * * SECTION 504 SAFETY DEVICES * * * P-504.6 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: * * * 5. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor or to the outdoors. * * * 504.7 Required Pan. Where a storage tank-type water heater or a hot water storage tank is installed in a location where water leakage from the tank will cause damage, the tank shall be installed in a pan constructed of one of the following: * * * P-504.7.2 Pan drain termination. The pan drain shall extend full size and terminate over a suitably located indirect waste receptor or floor drain or extend to the exterior of the building and terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. Where a pan drain was not previously installed, a pan drain shall not be required for a replacement water heater installation. The pan drain shall be permitted to discharge into a clothes washer box with dual drainage outlets with one outlet dedicated to the clothes washer discharge and one outlet dedicated to the pan drain. The pan drain shall also be permitted to drain into a clothes washer box with a single drainage outlet where the inlet of the clothes washer box outlet is sized to accommodate both the clothes washer discharge and the pan drain discharge. * * * CHAPTER 6 WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL * * * 601.5 Rehabilitation of piping systems. Where pressure piping systems are rehabilitated using an epoxy lining system, such lining system shall comply with ASTM F2831. * * * SECTION 602 WATER REQUIRED * * * P-602.1.1 Separate water connection. A building having plumbing fixtures installed and intended for human habitation, occupancy or use on premises abutting on a street, alley, or easement in which there is a public water main shall have a separate connection to the public water main. Where located on the same deeded property and maintained under the same ownership, multiple buildings shall not be prohibited from connecting to a common private water distribution pipe that connects to the public water main provided that the common private water distribution pipe is not placed underneath any building or structure and is connected after the existing water meter. P-602.1.1.1 Non-residential. Non-residential buildings and other structures on the same deeded property and maintained under the same ownership shall be permitted to connect to a common water supply. P-602.1.1.2 Residential. Where one building stands in the rear of another building on the same deeded property and maintained under the same ownership, and a separate water supply cannot be provided for the rear building through an alley, yard or other open public space, the water supply of the front building shall be permitted to serve the rear building, provided the water supply of the front building is of adequate size and in suitable condition to serve both front and rear buildings. * * * 602.3 Individual water supply. Where a potable public water supply is not available, individual sources of potable water supply shall be utilized. P-602.3.1 Sources. Dependent on geological and soil conditions and the amount of rainfall, individual water supplies are of the following types type: drilled well. well, driven well, dug well, bored well, spring, stream or cistern. Surface bodies of water and land cisterns shall not be sources of individual water supply unless properly treated by approved means to prevent contamination. Individual water supplies shall be constructed and installed in accordance with the applicable state and local laws. Where such laws do not address all of the requirements set forth in NGWA-01, individual water supplies shall comply with NGWA-01 for those requirements not addressed by state and local laws. Note: Each well’s water quality requires approval by the Department of Public Health. * * * P-602.4 Private water distribution pipes. Repairs to Existing Private water distribution pipe materials shall be in accordance with Section 605. New or extended water distribution pipes may not cross any adjoining property lines except private water infrastructure designed in accordance with Section P-614. * * * SECTION P-603 WATER SERVICE DISTRIBUTION P-603.1 Size of water service distribution pipe. The water service distribution pipe shall be sized to supply water to the structure in the quantities and at the pressures required in this code. The water service distribution pipe shall be not less than 3/4 inch (19.1 mm) in diameter. P-603.2 Separation of water service, water distribution piping and, building sewer, building drains, storm sewer or storm drainage piping. Where water service piping is located in the same trench with the building sewer, such sewer shall be constructed of materials listed in Table 702.2. Where the building sewer piping is not constructed of materials listed in Table 702.2, the water service pipe and the building sewer shall be horizontally separated by not less than 5 feet (1524 mm) of undisturbed or compacted earth. Water distribution piping shall be horizontally separated by not less than 5 feet of undisturbed or compacted earth when it is adjacent to nonmetallic pipe material serving building sewers, building drains, storm sewer or storm drainage piping. The water distribution pipe shall be separated not less than 12" vertical and 12" horizontal from the outer edge of building sewers, building drains, storm sewers or storm drainage piping where metallic piping is used. The required separation distance shall not apply where a water service distribution pipe crosses a building sewer pipe, building drains, storm sewer or storm drainage piping, provided that the water service water distribution piping is at least 12" above such pipe and sleeved to a point not less than 5 feet (1524 mm) horizontally from the building sewer, building drains, storm sewer or storm drainage pipe centerline on both sides of such crossing. The sleeve shall be of pipe materials listed in Table 605.3, 702.2 or 702.3. The required separation distance shall not apply where the bottom of the water service pipe, located within 5 feet (1524 mm) of the sewer, is not less than 12 inches (305 mm) above the highest point of the top of the building sewer. P-603.2.1 Water service Water distribution pipe near sources of pollution. Potable water service pipes water distribution pipe shall not be located in, under or above cesspools, septic tanks, septic tank drainage fields or seepage pits. Where soil or ground water causes contaminated conditions for piping, analysis shall be required in accordance with Section P-605.1. P-603.3 Property lines. Water distribution pipes may not cross adjoining property lines except private water infrastructure designed in accordance with Section P-614. SECTION P-604 DESIGN OF BUILDING WATER DISTRIBUTION SUPPLY SYSTEM P-604.1 General. The design of the water distribution supply system shall conform to accepted engineering practice. Methods utilized to determine pipe sizes shall be approved. * * * P-604.3 Water distribution supply system design criteria. The water distribution supply system shall be designed, and pipe sizes shall be selected such that under conditions of peak demand, the capacities at the fixture supply pipe outlets shall be not less than shown in Table P-604.3. The minimum flow rate and flow pressure provided to fixtures and appliances not listed in Table P-604.3 shall be in accordance with the manufacturer’s installation instructions. TABLE P-604.3 WATER DISTRIBUTION SUPPLY SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS * * * P-604.5 Size of fixture supply. The minimum size of a fixture supply pipe shall be as shown in Table 604.5. The fixture supply pipe shall terminate not more than 30 inches (762 mm) from the point of connection to the fixture. A reduced-size flexible water connector installed between the supply pipe and the fixture shall be of an approved type. The supply pipe shall extend to the floor or wall adjacent to the fixture. The minimum size of individual distribution supply lines utilized in gridded or parallel water supply systems shall be as shown in Table 604.5. A ridged water connector shall be required in all occupancies other than one- and two-family dwellings. * * * P-604.6 Variable street pressures. Where street water main pressures fluctuate, the building water distribution supply system shall be designed for the minimum pressure available. * * * P-604.8 Water pressure-reducing valve or regulator. Where water pressure within a building exceeds 80 psi (552 kPa) static, an approved water pressure-reducing valve conforming to ASSE 1003 or CSA B356 with strainer shall be installed to reduce the pressure in the building water distribution supply piping to not greater than 80 psi (552 kPa) static. Exception: Service lines to sill cocks and outside hydrants, and main supply risers where pressure from the mains is reduced to 80 psi (552 kPa) or less at individual fixtures. * * * P-604.9 Water hammer. The flow velocity of the water distribution supply system shall be controlled to reduce the possibility of water hammer. A water-hammer arrestor shall be installed where quick-closing valves are utilized. Water-hammer arrestors shall be installed in accordance with the manufacturer’s instructions. Water-hammer arrestors shall conform to ASSE 1010. P-604.10 Gridded and parallel water distribution supply system manifolds. Hot water and cold water manifolds installed with gridded or parallel connected individual distribution supply lines to each fixture or fixture fitting shall be designed in accordance with Sections 604.10.1 through 604.10.3. * * * SECTION 605 MATERIALS, JOINTS AND CONNECTIONS P-605.1 Soil and ground water. The installation of a water service or water distribution pipe or water-supply pipes shall be prohibited in soil and ground water contaminated with solvents, fuels, organic compounds or other detrimental materials causing permeation, corrosion, degradation or structural failure of the piping material. Where detrimental conditions are suspected, a chemical analysis of the soil and ground water conditions shall be required to ascertain the acceptability of the water service or water distribution piping material for the specific installation. Where detrimental conditions exist, approved alternative materials or routing shall be required * * * P-605.3 Water service distribution pipe. Water service distribution pipe shall conform to NSF 61 and shall conform to one of the standards listed in Table 605.3. Water service distribution pipe or tubing, installed underground and outside of the structure, shall have a working pressure rating of not less than 160 psi (1100 kPa) at 73.4ºF (23ºC). Where the water pressure exceeds 160 psi (1100 kPa), piping material shall have a working pressure rating not less than the highest available pressure. Water service distribution piping materials not third-party certified for water distribution supply shall terminate at or before the full open valve located at the entrance to the structure. Ductile iron water service distribution piping shall be cement mortar lined in accordance with AWWA C104/A21.4. Any water distribution pipe serving or located within occupancies other than one-and two-family dwellings and apartments shall be metallic piping in accordance with this section and listed on Table P-605.3. All water service piping from the City water main tap to the curb stop shall conform to the regulations as set forth by the Philadelphia Water Department. Exception: Pipes 3 inches and larger shall be ductile iron to the meter. TABLE P-605.3 WATER SERVICE DISTRIBUTION PIPE * * * P-605.4 Water distribution supply pipe. Water distribution supply pipe and tubing shall conform to NSF 61 and shall conform to one of the standards listed in Table 605.4. Hot water distribution supply pipe and tubing shall have a pressure rating of not less than 100 psi (690 kPa) at 180ºF (82ºC). Any water supply piping supplying or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this section. TABLE P-605.4 WATER DISTRIBUTION SUPPLY PIPE * * * P-605.4.1 High rise materials. Metallic piping shall be installed in buildings with an occupied floor located more than 75 feet (22,860 mm) above the lowest level of fire department vehicle access. Exception: Nonmetallic piping may be used within demised individual residential dwelling units located within buildings with an occupied floor located more than 75 feet (22,860 mm) and not more than 150 feet (45,720 mm) above the lowest level of fire department vehicle access. * * * P-605.5 Fittings. Pipe fittings shall be approved for installation with the piping material installed and shall comply with the applicable standards listed in Table 605.5. Pipe fittings utilized in water supply systems shall also comply with NSF 61. Ductile and gray iron pipe and pipe fittings utilized in water service distribution piping systems shall be cement mortar lined in accordance with AWWA C104/A21.4. * * * P-605.6 Flexible water connectors. Flexible water connectors shall be prohibited. Exception: In one- and two-family dwellings, flexible water connectors where exposed to continuous pressure shall conform to ASME A112.18.6/CSA B125.6. Access shall be provided to all flexible water connectors. * * * 605.13 Copper tubing. Joints between copper or copper-alloy tubing and fittings shall comply with Sections 605.13.1 through 605.13.7. * * * P-605.13.5 Press-connect joints. Press-connect joints shall conform to one of the standards indicated in Table 605.5, and shall be installed in accordance with the manufacturer’s instructions. Cut tube ends shall be reamed to the full inside diameter of the tube end. Joint surfaces shall be cleaned. The tube shall be fully inserted into the press-connect fitting. Press-connect joints shall be pressed with a tool certified by the manufacturer. Press-connect joints shall be limited to above ground installations only. * * * P-605.13.7 Push-fit joints. Push-fit joints shall conform to ASSE 1061 and shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. 605.14 CPVC plastic. Joints between CPVC plastic pipe and fittings shall comply with Sections 605.14.1 through 605.14.4. * * * P-605.14.4 Push-fit joints. Push-fit joints shall conform to ASSE 1061 and shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. * * * SECTION P-606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SUPPLY SYSTEM * * * P-606.7 Labeling of water distribution pipes in bundles. Where water distribution piping is bundled at installation, each pipe in the bundle shall be identified using stenciling or commercially available pipe labels. The identification shall indicate the pipe contents and the direction of flow in the pipe. The interval of the identification markings on the pipe shall not exceed 25 feet (7620 mm). There shall be not less than one identification label on each pipe in each room, space or story. SECTION 607 HOT WATER SUPPLY SYSTEM * * * 607.2 Hot or tempered water supply to fixtures. The developed length of hot or tempered water piping, from the source of hot water to the fixtures that require hot or tempered water, shall not exceed 50 feet (15 240 mm). Recirculating system piping and heat-traced piping shall be considered to be sources of hot or tempered water. * * * P-607.2.1 Circulation systems and heat trace systems for maintaining heated water temperature in distribution supply systems. For Group R2, R3 and R4 occupancies that are three stories or less in height above grade plane, the installation of heated water circulation and temperature maintenance systems shall be in accordance with Section R403.5.1 of the International Energy Conservation Code. For other than Group R2, R3 and R4 occupancies that are three stories or less in height above grade plane, the installation of heated water circulation and heat trace systems shall be in accordance with Section C404.6 of the International Energy Conservation Code. * * * P-607.2.1.2 Demand recirculation controls for distribution supply systems. A water distribution supply system having one or more recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe shall be a demand recirculation water system. Pumps shall have controls that comply with both of the following: 1. The control shall start the pump upon receiving a signal from the action of a user of a fixture or appliance, sensing the presence of a user of a fixture, or sensing the flow of hot or tempered water to a fixture fitting or appliance. 2. The control shall limit the temperature of the water entering the cold water piping to 104°F (40°C). * * * P-607.3 Thermal expansion control. Where a storage water heater is supplied with cold water that passes through a check valve, pressure reducing valve or backflow preventer, a thermal expansion control device shall be connected to the water heater cold water supply pipe at a point that is downstream of all check valves, pressure reducing valves and backflow preventers. Thermal expansion tanks shall be sized in accordance with the tank manufacturer’s instructions and shall be sized such that the pressure in the water distribution supply system shall not exceed that required by Section 604.8. * * * SECTION 608 PROTECTION OF POTABLE WATER SUPPLY 608.1 General. A potable water supply system shall be designed, installed and maintained in such a manner so as to prevent contamination from nonpotable liquids, solids or gases being introduced into the potable water supply through cross connections or any other piping connections to the system. Backflow preventer applications shall conform to Table 608.1, except as specifically stated in Sections 608.2 through 608.17.10. P-608.1.1 Backflow containment assemblies required. Backflow containment assemblies shall be installed in all buildings. Exception: Residential buildings with four dwelling units or less. P-608.1.2 Installation of backflow containment assemblies. Installation shall be in accordance with Philadelphia Water Department Regulation 403 and the Philadelphia Water Department Cross Connection Control Manual, as amended. * * * P-608.4 Potable water handling and treatment equipment. Water pumps, filters, softeners, tanks and other appliances and devices that handle or treat potable water to be supplied to the potable water distribution supply system shall be located to prevent contamination from entering the appliances and devices. Overflow, relief valve and waste discharge pipes from such appliances and devices shall terminate through an air gap. * * * 608.9 Identification of nonpotable water systems. Where nonpotable water systems are installed, the piping conveying the nonpotable water shall be identified either by color marking, metal tags or tape in accordance with Sections 608.9.1 through 608.9.2.3. * * * P-608.9.2 Distribution pipe labeling and marking. Non-potable distribution and supply piping shall be purple in color and shall be embossed, or integrally stamped or marked, with the words: “CAUTION: NONPOTABLE WATER – DO NOT DRINK” or the piping shall be installed with a purple identification tape or wrap. Pipe identification shall include the contents of the piping system and an arrow indicating the direction of flow. Hazardous piping systems shall also contain information addressing the nature of the hazard. Pipe identification shall be repeated at intervals not exceeding 25 feet (7620 mm) and at each point where the piping passes through a wall, floor or roof. Lettering shall be readily observable within the room or space where the piping is located. * * * P-608.9.2.3 Identification tape. Where used, identification tape shall be not less than 3 inches (76 mm) wide and have white or black lettering on a purple field stating “CAUTION: NONPOTABLE WATER – DO NOT DRINK.” Identification tape shall be installed on top of nonpotable rainwater distribution and supply pipes, fastened not less than every 10 feet (3048 mm) to each pipe length and run continuously the entire length of the pipe. * * * 608.17 Connections to the potable water system. Connections to the potable water system shall conform to Sections 608.17.1 through 608.17.10. * * * P-608.17.4 Connections to automatic sprinkler systems and standpipe systems. The potable water supply to automatic sprinkler systems and standpipe systems shall be protected against backflow by a double check backflow prevention assembly, a double check fire protection backflow prevention assembly or a reduced pressure principle fire protection backflow prevention assembly. Exceptions: 1. Where systems are installed as a portion of the water distribution supply system in accordance with the requirements of this code and are not provided with a fire department connection, isolation of the water supply system shall not be required. 2. Isolation of the water distribution supply system is not required for deluge, preaction or dry pipe systems. * * * P-608.17.7 Chemical dispensers. Where chemical dispensers connect to the potable water distribution supply system, the water supply system shall be protected against backflow in accordance with Section 608.14.1, 608.14.2, 608.14.5, 608.14.6, or 608.14.8. P-608.17.8 Portable cleaning equipment. Where the portable cleaning equipment connects to the water distribution supply system, the water supply system shall be protected against backflow in accordance with Section 608.14.1, 608.14.2, 608.14.3, 608.14.7 or 608.14.8. * * * 608.18 Protection of individual water supplies. An individual water supply shall be located and constructed so as to be safeguarded against contamination in accordance with Sections 608.18.1 through 608.18.87. P-608.18.1 Well locations. A potable ground water source or pump suction line shall not be located closer to potential sources of contamination than the distances shown in Table 608.18.1. In the event the underlying rock structure is limestone or fragmented shale, the local or state health department shall be consulted on well site location. The distances in Table 608.18.1 constitute minimum separation and shall be increased in areas of creviced rock or limestone, or where the direction of movement of the ground water is from sources of contamination toward the well. Note: All well-water quality requires approval by the Department of Public Health. * * * 608.18.6 Dug or bored well casings. Dug or bored well casings shall be of water-tight concrete, tile or galvanized or corrugated metal pipe extending to not less than 10 feet (3048 mm) below the ground surface. Where the water table is more than 10 feet (3048 mm) below the ground surface, the water-tight casing shall extend below the table surface. Well casings for dug wells or bored wells con- structed with sections of concrete, tile or galvanized or corrugated metal pipe shall be surrounded by 6 inches (152 mm) of grout poured into the hole between the out- side of the casing and the ground and extending not less than 10 feet (3048 mm) below the ground surface. P-608.18.76 Cover. Potable water wells shall be equipped with an overlapping water-tight cover at the top of the well casing or pipe sleeve such that contaminated water or other substances are prevented from entering the well through the annular opening at the top of the well casing, wall or pipe sleeve. Covers shall extend downward not less than 2 inches (51 mm) over the outside of the well casing or wall. A dug well cover shall be provided with a pipe sleeve permitting the withdrawal of the pump suction pipe, cylinder or jet body without disturbing the cover. Where pump sections or discharge pipes enter or leave a well through the side of the casing, the circle of contact shall be water tight. P-608.18.87 Drainage. Potable water wells and springs shall be constructed such that surface drainage will be diverted away from the well or spring. * * * SECTION 609 HEALTH CARE PLUMBING * * * P-609.2 Water service and distribution for Group I-2, Condition 2 facilities. Hospitals Group I-2, Condition 2 facilities shall have not fewer than two water service pipes and water distribution pipes sized such that with the loss of the largest service pipe, the remaining service pipes will meet the water demand for the entire facility. Each water service shall have a shutoff valve in the building and a shutoff valve at the utility-provided point of connection to the water main or other source of potable water. * * * SECTION 610 DISINFECTION OF POTABLE WATER SYSTEMS P-610.1 General. New potable water systems shall be purged of deleterious matter and disinfected prior to utilization. The method to be followed shall be that prescribed by the health authority or water purveyor having jurisdiction or, in the absence of a prescribed method, the procedure described in either AWWA C651 or AWWA C652, or as described in this section. This requirement shall apply to “on-site” or “in-plant” fabrication of a system or to a modular portion of a system. Exception: Analysis and disinfection shall not be required for interior piping or water distribution piping servicing one- and two-family dwellings and townhouses up to three stories in height. * * * SECTION P-614 PRIVATE WATER INFRASTRUCTURE P-614.1 General. The provisions of this section shall govern the materials, design, and construction of Private Water Infrastructure. P-614.1.1 Definitions. The following definitions shall apply to Private Water Infrastructure. MASTER METER. A measuring device owned and maintained by the Philadelphia Water Department used to collect data and indicate water usage from multiple individually metered units in a Condominium or Planned Community. PRIVATE WATER INFRASTRUCTURE PIPE. The pipe that is constructed on private property between the Master Meter and the Private Water Distribution Pipe owned and maintained by the Unit Owner’s Association to serve some or all units within a Condominium or Planned Community. PRIVATE WATER DISTRIBUTION PIPE. For the purposes of this section, this is limited to the section of pipe located between the Private Water Infrastructure Pipe and the individual building. P-614.2 Materials. The Private Water Infrastructure Pipe and Private Water Distribution Pipe shall conform to one of the standards listed in Table 605.3 of this code and the requirements shall be consistent with all materials, joints and connections listed in Section 605. P-614.3 Connections. The Private Water Distribution Pipe for each house or structure shall be connected to the Private Water Infrastructure Pipe separately. A Private Water Infrastructure Pipe used to convey both domestic and fire protection in a single pipe is permitted. P-614.3.1 Shut off valves. Each connection of the Private Water Distribution Pipe to the Private Water Infrastructure Pipe shall have an accessible shut off valve installed no less than 3 feet (914 mm) from the outside of the building wall and in line with the ferrule connection on the Private Water Infrastructure Pipe. P-614.4 Access for repairs. Separation of Private Water, Sanitary Sewer and Storm Sewer Infrastructure placed in the same alignment and at a depth not exceeding 5 feet (1524 mm) shall comply with Section 603.2 of this code. Infrastructure placed at depths greater than 5 feet (1524 mm) shall be horizontally separated at a distance that allows for the approved sheeting and shoring and not less than 2 feet (609 mm). P-614.5 Protection of structures. The Private Water Infrastructure Pipe installed parallel to footings and walls shall not extend into the bearing plane of a footing or wall in accordance with Section 307.5 of this code. Private Water Infrastructure pipe shall not be installed within 5 feet (1524 mm) of any adjoining property line. Private Water Infrastructure Pipe shall not be installed within 3 feet (914 mm) of any parallel building foundation. P-614.6 Fire hydrants. The Private Water Infrastructure Pipe with Fire hydrant connections shall be metered and require backflow protection in accordance with Philadelphia Water Department (PWD) Regulations. The Philadelphia Fire Department shall govern the placement of fire hydrants. PWD may direct the placement of blow-offs and meters on the Private Water Distribution Pipe to ensure water quality. Exception: A master meter on a Private Water Infrastructure Pipe used to convey both domestic and fire protection in a single pipe shall be an acceptable method to meter hydrants. P-614.7 Easement required. Private Water Infrastructure Pipe shall require an easement with a minimum width of 12 foot (3657 mm) and must provide adequate space to replace/ repair the private infrastructure. Minimum vertical drive height clearance of 13 feet 6 inches (4115 mm) or two times the pipe depth to pipe bottom, whichever is greater, shall be provided. The easement shall also provide access to individual private water distribution pipes and valves and allow for shut- offs when necessary. No permanent structures shall be built over or in the easement unless these vertical height clearances are met. SECTION P-615 ABANDONED WATER SUPPLY SYSTEM AND COMPONENTS P-615.1 Discontinuance of water service. Where a property no longer requires a water service connection the owner shall make application to the Philadelphia Water Department for a discontinuance permit. Abandoned water service piping shall be capped or plugged at the curb or shall have the ferrule removed. P-615.2 Abandonment of water distribution piping. Abandoned water distribution piping shall be capped or plugged at the curb line or at the meter pit and properly capped or plugged inside the building or structure at the nearest possible location to the point of entry. P-615.3 Abandoned water supply pipe. Abandoned water supply piping or water supply piping intended to serve future fixtures within a building or structure shall be capped or plugged with a fitting and provided with a valve within two feet of the point of origin of the water supply serving the abandoned piping or future fixture piping so as not to create a dead end or dead leg. Any abandoned water supply piping placed back into service shall be disinfected per Section 610. CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL * * * P-701.2 Connection to sewer required. Sanitary drainage piping from plumbing fixtures in buildings and sanitary drainage piping systems from premises shall be connected to a public sewer. Where a public sewer is not available, the sanitary drainage piping and systems shall be connected to a private sewage disposal system in compliance with state or local requirements. the regulations of the Department of Public Health. Where state or local requirements do not exist for private sewage disposal systems, the sanitary drainage piping and systems shall be connected to an approved private sewage disposal system that is in accordance with the International Private Sewage Disposal Code. Exception: Sanitary drainage piping and systems that convey only the discharge from bathtubs, showers, lavatories, clothes washers and laundry trays shall not be required to connect to a public sewer or to a private sewage disposal system provided that the piping or systems are connected to a system in accordance with Chapter 13 and 14. P-701.2.1 Private building sewer. Repairs to existing private building sewer pipe materials shall be in accordance with Table P-702.3. New or extended private building sewers may not cross any adjoining property lines except private sanitary sewer infrastructure designed in accordance with Section P-717. P-701.3 Separate sewer connection. A building having plumbing fixtures installed and intended for human habitation, occupancy or use on premises abutting on a street, alley or easement in which there is a public sewer shall have a separate connection with the sewer. Where located on the same lot, multiple buildings shall not be prohibited from connecting to a common building sewer that connects to the public sewer provided that the common building sewer is not placed underneath any building or structure. P-701.3.1 Non-residential. Non-residential buildings and other structures on the same deeded property and maintained under the same ownership shall be permitted to connect to the same building sewer. P-701.3.2 Residential. Where one building stands in the rear of another building on the same deeded property and maintained under the same ownership, and a separate building sewer cannot be provided for the rear building through an alley, yard or other open public space, the building sewer of the front building shall be permitted to serve the rear building, provided the building sewer of the front building is of adequate size and in suitable condition to serve both front and rear buildings. P-701.4 Sewage treatment. Sewage or other waste from a plumbing system that is deleterious to surface or subsurface waters shall not be discharged into the ground or into any waterway unless it has first been rendered innocuous through subjection to an approved form of treatment. P-701.5 Damage to drainage system or public sewer. Waste detrimental to the public sewer system or to the functioning of the sewage-treatment plant shall be treated and disposed of in accordance with Section 1003 as directed by the code official and the Industrial Waste Unit of the Philadelphia Water Department. * * * P-701.8 Abandonment of building sewer and lateral. Abandoned laterals shall have the house trap removed, and the pipe shall be hermetically sealed by a cap or plug encased in concrete at the curb line. Laterals 8 inches (203 mm) and greater shall be sealed by a cap or plug encased in concrete at the point of connection to the public sewer. Abandoned drainage piping within the building shall be hermetically sealed by a cap or plug. P-701.8.1 Permit. A plumbing permit is required for abandonment of building sewers and laterals and work shall be performed by a Registered Master Plumber. P-701.9 Property Lines. Drainage piping may not cross adjoining property lines except private sewer infrastructure designed in accordance with Section P-717. SECTION 702 MATERIALS P-702.1 Above-ground sanitary drainage and vent pipe. Above-ground soil, waste and vent pipe shall conform to one of the standards listed in Table 702.1. Any above ground soil, waste and vent piping serving or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this Section. TABLE P-702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE MATERIAL | STANDARD * * * Copper or copper-alloy tubing a (Type K, L, M or DWV) | ASTM B75; ASTM B88; ASTM B251; ASTM B306 * * * a. Type K copper tubing must be used for the drainage of all urinals. P-702.1.1 High-rise material. Metallic piping shall be installed throughout buildings with an occupied floor located more than 75 feet (22,860 mm) above the lowest level of fire department vehicle access. P-702.2 Underground building sanitary drainage and vent pipe. Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table P-702.2. Any underground building sanitary drainage and vent piping serving or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this section. P-702.2.1 High-rise material. Metallic piping shall be installed for all underground building sanitary drainage and vent piping for buildings with an occupied floor located more than 75 feet (22,860 mm) above the lowest level of fire department vehicle access. TABLE P-702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE MATERIAL | STANDARD Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall | ASTM D2661; ASTM F628; ASTM F1488; CSA B181.1 Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 * * * Ductile iron pipe class 56 | AWWA C151/A21.51; AWWA C115/A21.15 * * * Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall | ASTM D2665; ASTM F891; ASTM F1488; CSA B181.2 Polyvinyl chloride (PVC) plastic pipe with a 3.25-inch O.D. and a solid, cellular core or composite wall | ASTM D2949, ASTM F1488 * * * | P-702.3 Building sewer pipe. Building sewer pipe shall conform to one of the standards listed in Table P-702.3. Any building sewer pipe serving or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this section. TABLE P-702.3 BUILDING SEWER PIPE MATERIAL | STANDARD Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140) with a solid, cellular core or composite wall | ASTM D2661; ASTM F628; ASTM F1488; CSA B181.1 Acrylonitrile butadiene styrene (ABS) plastic pipe in sewer and drain diameters, including SDR 42 (PS 20), PS 35, SDR 35 (PS 45), PS 50, PS 100, PS 140, SDR 23.5 (PS 150) and PS 200; with a solid, cellular core or composite wall | ASTM F1488; ASTM D2751 Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 * * * Ductile iron pipe class 56 | AWWA C151/A21.51; AWWA C115/A21.15 * * * Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall | ASTM D2665; ASTM F891; ASTM F1488 Polyvinyl chloride (PVC) plastic pipe in sewer and drain diameters, including PS 25, SDR 41 (PS 28), PS 35, SDR 35 (PS 46), PS 50, PS 100, SDR 26 (PS 115), PS 140 and PS 200; with a solid, cellular core or composite wall | ASTM F891; ASTM F1488; ASTM D3034; CSA B182.2; CSA B182.4 Polyvinyl chloride (PVC) plastic pipe with a 3.25-inch O.D. and a solid, cellular core or composite wall | ASTM D2949; ASTM F1488 * * * | P-702.3.1 High-rise material. Metallic piping shall be installed for all building sewer pipe for buildings with an occupied floor located more than 75 feet (22,860 mm) above the lowest level of fire department vehicle access. P-702.3.2 Lateral. Lateral materials and installation shall be regulated by the Philadelphia Water Department. * * * TABLE P-702.4 PIPE FITTINGS MATERIAL | STANDARD * * * Ductile iron pipe class 56 | AWWA C151/A21.51; AWWA C115/A21.15 * * * P-702.6 Chemical waste system. A chemical waste system shall be completely separated from the sanitary drainage system. The chemical waste shall be treated in accordance with Section 803.2 before discharging to the sanitary drainage system. Separate drainage systems for chemical wastes and vent pipes shall be of an approved material that is resistant to corrosion and degradation for the concentrations of chemicals involved. The restrictions on non-metallic pipe shall not apply to this section. P-702.7 Reserved. Lead bends and traps. The wall thickness of lead bends and traps shall be not less than 1/8 inch (3.2 mm). SECTION 703 BUILDING SEWER P-703.1 Building sewer pipe near the water service. The proximity of a sewer to a water service distribution shall comply with Section P-603.2. P-703.2 Drainage pipe in filled ground. Where a building sewer or building drain is installed on filled or unstable ground, the drainage pipe shall conform to one of the standards for ABS plastic pipe, cast-iron pipe, copper or copper-alloy tubing, PVC plastic pipe or polypropylene plastic pipe or stainless steel drainage systems, Type 304 and 316L as indicated in Table P-702.3. When drainage is installed in filled or unstable ground, it shall be of cast iron or hard temper copper tube of a weight not less than type “L” or stainless steel drainage systems, Type 304 and 316L. Pipe shall be supported on concrete piers with spacing consistent with Table 308.5, or a constant bed of concrete or clevis hangers attached to reinforcing rods in the concrete floor above the piping. * * * 703.4 Existing building sewers and building drains. Where the entire sanitary drainage system of an existing building is replaced, existing building drains under concrete slabs and existing building sewers that will serve the new system shall be internally examined to verify that the piping is sloping in the correct direction, is not broken, is not obstructed and is sized for the drainage load of the new plumbing drainage system to be installed. P-703.4.1 Connections to existing private building sewers. Where connections are made to existing private building sewers, all provisions of 703.4 shall apply including confirmation and acceptance of condition and sizing by a registered design professional. P-703.4.1.1 Extension of existing private building sewers. Extension of existing private building sewers is prohibited. * * * P-703.6 Combined sanitary and storm public sewer. Where the public sewer is a combined system for both sanitary and storm water, the sanitary sewer shall be connected independently to the public sewer lateral, unless otherwise approved by the Philadelphia Water Department. Exception: The repair or replacement of an existing combined building sewer as of the initial adoption date of this code. The size of such replacements shall comply with section 1109.2. P-703.6.1 Separation. Storm water shall not be drained into sewers that are intended only for sanitary sewage. Sanitary waste shall not be drained into sewers that are intended only for storm water. * * * SECTION 704 DRAINAGE PIPING INSTALLATION P-704.1 Slope of horizontal drainage piping. Horizontal drainage piping shall be installed in uniform alignment at uniform slopes. The slope of a horizontal drainage pipe shall be not less than that indicated in Table P-704.1 except that where the drainage piping is upstream of a grease interceptor, the slope of the piping shall be not less than 1/4 inch per foot (2-percent slope). Building sewer force mains are not permitted. TABLE P-704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE SIZE (inches) | MINIMUM SLOPE (inch per foot) 2-1/2 3 or less | 1/4 a 3 4 to 6 | 1/8 a 8 or larger | 1/16 a * * * P-704.5 Dead ends. In the installation or removal of any part of a drainage system, dead ends shall be prohibited. Cleanout extensions and approved future fixture drainage piping shall not be considered as dead ends. * * * SECTION 705 JOINTS * * * 705.2 ABS plastic. Joints between ABS plastic pipe or fittings shall comply with Sections 705.2.1 through 705.2.3. P-705.2.1 Reserved. Mechanical joints. Mechanical joints on drainage pipes shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212 or CSA B602. Mechanical joints shall be installed only in underground systems unless otherwise approved. Joints shall be installed in accordance with the manufacturer’s instructions. * * * P-705.2.4 Reserved. Push-fit joints. Push-fit DWV fittings shall be listed and labeled to ASME A112.4.4 and shall be installed in accordance with the manufacturer’s instructions. 705.3 Cast iron. Joints between cast-iron pipe or fittings shall comply with Sections 705.3.1 through 705.3.3. * * * P-705.3.3 Mechanical joint coupling. Mechanical joint couplings for hubless pipe and fittings shall consist of an elastomeric sealing sleeve and a metallic shield that comply with CISPI 310, ASTM C1277 or ASTM C1540. The elastomeric sealing sleeve shall conform to ASTM C564 or CSA B602 and shall be provided with a center stop. Mechanical joint couplings shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. P-705.3.4 Repair or connection of the building (house) drain or building sewer. A cast-iron double hub fitting and fission joint when using lead and oakum shall be acceptable for repair or connection of a building (house) drain or building sewer. On one side of a repair or connection to a building (house) drain or building sewer, either a cast-iron hubless coupling consisting of a cast-iron housing complying with ASTM A1056 and C564, stainless steel nuts and bolts that comply with ANSI B18.2.1 and ANSI B18.2.2 and a neoprene gasket that comply with ASTM C564 or an adjustable repair coupling for hubless pipe and fittings consisting of an elastomeric sealing sleeve and a metallic housing that comply with CISPSI 310 and ASTM A240, the elastomeric sealing sleeve shall conform to ASTM C425 or C1173 and shall be provided with a center stop, shall be acceptable. Note: An adjustable repair coupling shall be permitted on each side of the repair or connection. The use of two adjustable repair couplings shall require a concrete encasement of the coupling on both sides of the repair or connection. P-705.3.5 Replacement of existing building (house) traps. For replacement of an existing building (house) trap an adjustable repair coupling for hubless pipe and fitting consisting of an elastomeric sealing sleeve and a metallic housing that comply with CISPI 310 and ASTM A240, the elastomeric sealing sleeve shall conform to ASTM C425 or C1173 and shall be provided with a center stop, shall be permitted on one side of the trap. Note: Under severe conditions, an adjustable repair coupling shall be permitted on each side of the trap. The use of two adjustable repair couplings shall require a concrete encasement of the coupling on the street side of the trap. * * * 705.5 Copper Pipe. Joints between copper or copper-alloy pipe or fittings shall comply with Sections 705.5.1 through 705.5.5. * * * P-705.5.2 Mechanical joints. Mechanical joints shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. P-705.5.3 Solder joints. Solder joints shall be made in accordance with the methods of ASTM B828. Cut tube ends shall be reamed to the full inside diameter of the tube end. Joint surfaces shall be cleaned. A flux conforming to ASTM B813 shall be applied. The joint shall be soldered with a solder conforming to ASTM B32. All solder joints shall be made with lead-free solder and flux. “Lead free” shall mean a chemical composition equal to or less than 0.2-percent lead. 705.6 Copper Tubing. Joints between copper or copper-alloy tubing or fittings shall comply with Sections 705.6.1 through 705.6.3. * * * P-705.6.2 Mechanical joints. Mechanical joints shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. P-705.6.3 Solder joints. Solder joints shall be made in accordance with the methods of ASTM B828. Cut tube ends shall be reamed to the full inside diameter of the tube end. Joint surfaces shall be cleaned. A flux conforming to ASTM B813 shall be applied. The joint shall be soldered with a solder conforming to ASTM B32. All solder joints shall be made with lead-free solder and flux. “Lead free” shall mean a chemical composition equal to or less than 0.2-percent lead. * * * 705.8 Steel. Joints between galvanized steel pipe or fittings shall comply with Sections 705.8.1 and 705.8.2. * * * P-705.8.2 Mechanical joints. Joints shall be made with an approved elastomeric seal. Mechanical joints shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. P-705.9 Lead. Joints between lead pipe or fittings shall be prohibited. comply with Sections 705.9.1 and 705.9.2. 705.9.1. Burned. Burned joints shall be uniformly fused together into one continuous piece. The thickness of the joint shall be not less than the thickness of the lead being joined. The filler metal shall be of the same material as the pipe. 705.9.2 Wiped. Joints shall be fully wiped, with an exposed surface on each side of the joint not less than 3/4 inch (19.1 mm). The joint shall be not less than 3/8 inch (9.5 mm) thick at the thickest point. 705.10 PVC Plastic. P-705.10.1 Mechanical joints. Prohibited. Mechanical joints on drainage pipe shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212 or CSA B602. Mechanical joints shall not be installed in above-ground systems, unless otherwise approved. Joints shall be installed in accordance with the manufacturer’s instructions. P-705.10.2 Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F656 shall be applied. Solvent cement not purple in color and conforming to ASTM D2564, CSA B137.3, CSA B181.2 or CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D2855. Solvent cement joints shall be permitted above or below ground. Exception: A primer is not required where both of the following conditions apply: 1. The solvent cement used is third-party certified as conforming to ASTM D2564. 2. The solvent cement is used only for joining PVC drain, waste and vent pipe and fittings in nonpressure applications in sizes up to and including 4 inches (102 mm) in diameter. * * * P-705.10.4 Reserved. Push-fit joints. Push-fit joints shall conform to ASME A112.4.4 and shall be installed in accordance with the manufacturer’s instructions. * * * 705.12 Polyethylene plastic pipe. * * * P-705.12.2 Mechanical joints. Mechanical joints in drainage piping shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212 or CSA B602. Mechanical joints shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. 705.13 Polyolefin plastic. * * * P-705.13.2 Mechanical and compression sleeve joints. Mechanical and compression sleeve joints shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. * * * 705.14 Polyvinylidene fluoride plastic. * * * P-705.14.2 Mechanical and compression sleeve joints. Mechanical and compression sleeve joints shall be installed in accordance with the manufacturer’s instructions and limited to above ground installations only. Unshielded mechanical couplings are not permitted. P-705.15 Polypropylene plastic. The joint between polypropylene plastic pipe and fittings shall incorporate an elastomeric seal. The joint shall conform to ASTM D3212. The joint shall conform to ASTM D3212. Mechanical joints shall not be installed below ground in accordance with product specifications. P-705.16 Joints between different materials. Joints between different piping materials shall be made with a mechanical joint of the compression or mechanical-sealing type conforming to ASTM C1173, ASTM C1460 or ASTM C1461 and limited to above ground installations only. Connectors and adapters shall be approved for the application and such joints shall have an elastomeric seal conforming to ASTM C425, ASTM C443, ASTM C564, ASTM C1440, ASTM F477, CSA A257.3M or CSA B602, or as required in Sections 705.16.1 through 705.16.7. Joints between glass pipe and other types of materials shall be made with adapters having a TFE seal. Joints shall be installed in accordance with the manufacturer’s instructions. * * * P-705.16.5 Lead pipe to other piping material. Joints between lead pipe and other piping material shall be prohibited. made by a wiped joint to a caulking ferrule, soldering nipple or bushing or shall be made with an approved adapter fitting. * * * SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS * * * TABLE P-706.3 FITTINGS FOR CHANGE IN DIRECTION TYPE OF FITTING PATTERN | CHANGE IN DIRECTION Horizontal to vertical | Vertical to horizontal | Horizontal to horizontal * * * Quarter bend | X | X a, d | X a * * * d. A quarter bend shall be permitted in lieu of an ideal bend, on a dry vent above the highest fixture and in a storm system. * * * SECTION 708 CLEANOUTS P-708.1 Cleanouts required. Cleanouts shall be provided for drainage piping in accordance with Sections 708.1.1 through 708.1.12. A cleanout shall be provided at or near the base of each vertical waste or soil stack. P-708.1.1 Horizontal drains and building drains. Horizontal drainage pipes and building drains in buildings shall have cleanouts located at intervals of not more than 100 50 feet (30,480 15,240 mm) for lines four inch in diameter or less. Building Horizontal drainage pipes and building drains shall have cleanouts located at intervals of not more than 100 feet (30,480 mm) for lines five inch in diameter and above, except where manholes are used instead of cleanouts, the manholes shall be located at intervals of not more than 400 200 feet (122 61 m). The interval length shall be measured from the cleanout or manhole opening, along the developed length of the piping to the next drainage fitting providing access for cleaning, the end of the horizontal drain or the end of the building drain. Exception: Horizontal fixture drain piping serving a nonremovable trap shall not be required to have a cleanout for the section of piping between the trap and the vent connection for such trap. * * * 708.1.10 Cleanout access. Required cleanouts shall not be installed in concealed locations. For the purposes of this section, concealed locations include, but are not limited to, the inside of plenums, within walls, within floor/ceiling assemblies, below grade and in crawl spaces where the height from the crawl space floor to the nearest obstruction along the path from the crawl space opening to the clean-out location is less than 24 inches (610 mm). Cleanouts with openings at a finished wall shall have the face of the opening located within 1-1/2 inches (38 mm) of the finished wall surface. Cleanouts located below grade shall be extended to grade level so that the top of the cleanout plug is at or above grade. A cleanout installed in a floor or walkway that will not have a trim cover installed shall have a countersunk plug installed so the top surface of the plug is flush with the finished surface of the floor or walk-way. * * * P-708.1.10.2 Floor cleanout assemblies. Where it is necessary to protect a cleanout plug from the loads of vehicular traffic, cleanout assemblies in accordance with ASME A112.36.2M shall be installed. Note: An adjustable repair coupling shall be permitted to connect underground piping to a cleanout. * * * SECTION 709 FIXTURE UNITS * * * TABLE P-709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS FIXTURE TYPE | DRAINAGE FIXTURE UNIT VALUE AS LOAD FACTORS | MINIMUM SIZE OF TRAP (inches) * * * Emergency floor drain | 0 | 2 3 Floor drains b | 2 3 | 2 3 * * * * * * SECTION 710 DRAINAGE SYSTEM SIZING P-710.1 Maximum fixture unit load. The maximum number of drainage fixture units connected to a given size of building sewer, building drain or horizontal branch of the building drain shall be determined using Table P-710.1(1). The maximum number of drainage fixture units connected to a given size of horizontal branch or vertical soil or waste stack shall be determined using Table 710.1(2). TABLE P-710.1(1) BUILDING DRAINS AND SEWERS Diameter of Pipe (inches) | Maximum Number of Drainage Fixture Units Connected to Any Portion of the Building Drain or the Building Sewer, Including Branches of the Building Drain Slope per Foot 1/16-inch | 1/8-inch | 1/4-inch | 1/2-inch * * * 3 | - | 36 - | 42 | 50 * * * * * * SECTION 712 SUMPS AND EJECTORS * * * 712.3 Sump design. The sump pump, pit and discharge piping shall conform to the requirements of Sections 712.3.1 through 712.3.5. * * * P-712.3.2 Sump pit. The sump pit shall be not less than 18 inches (457 mm) in diameter and not less than 24 inches (610 mm) in depth, unless otherwise approved. The pit shall be provided with access and shall be located such that all drainage flows into the pit by gravity. The sump pit shall be constructed of tile, concrete, steel, plastic or other approved materials. The pit bottom shall be solid and provide permanent support for the pump. The sump pit shall be fitted with a gastight removable cover that is installed not more than 2 inches (51 mm) below grade or floor level. The cover shall be adequate to support anticipated loads in the area of use. The sump pit shall be vented in accordance with Chapter 9. Exception: An elevator sump pit shall not require a sealed cover. 712.3.3 Discharge pipe and fittings. Discharge pipe and fittings serving sump pump and ejectors shall be constructed of materials in accordance with Sections P-712.3.3.1 and 712.3.3.2. P-712.3.3.1 Materials. Pipe and fitting materials shall be constructed of copper or copper-alloy, CPVC, ductile iron, PE, or PVC., solid wall, galvanized steel pipe or stainless steel pipe for residential applications limited to one- and two-family dwellings. Discharge piping serving or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this Section. * * * P-712.4 Sewage pumps and sewage ejectors. A duplex sewage pump or sewage ejector shall automatically discharge the contents of the sump to the building drainage system. A simplex pump or sewage ejector shall be permitted for one- and two-family dwellings and where serving a single plumbing fixture waste, a single waste receptor or both in all other occupancies. P-712.4.1 Macerating toilet systems. Macerating toilet systems shall comply with ASME A112.3.4/CSA B45.9 and shall be installed in accordance with the manufacturer’s instructions, and shall be limited to use in one- and two-family residential dwellings only. P-712.4.2 Capacity. A sewage pump or sewage ejector shall have the capacity and head for the application requirements. Pumps or ejectors that receive the discharge of water closets shall be capable of handling spherical solids with a diameter of up to and including 2 inches (51 mm). Other pumps or ejectors shall be capable of handling spherical solids with a diameter of up to and including 1/2 inch (13 mm). The capacity of a pump or ejector based on the diameter of the discharge pipe shall be not less than that indicated in Table 712.4.2. Exceptions: 1. Grinder pumps or grinder ejectors that receive the discharge of water closets shall have a discharge opening of not less than 1-1/4 inches (32 mm). 2. Macerating toilet assemblies that serve single water closets shall have a discharge opening of not less than 3/4 inch (19.1 mm) and shall be limited to use in one- and two-family residential dwellings only. * * * SECTION 714 BACKWATER VALVES P-714.1 Sewage backflow. Where plumbing fixtures are installed on a floor with a finished floor elevation below the fresh air inlet termination elevation of the manhole cover of the next upstream manhole in the public sewer, such fixtures shall be protected by a backwater valve installed in the building drain, or horizontal branch serving such fixtures. Plumbing fixtures installed on a floor with a finished floor elevation above the elevation of the fresh air inlet termination manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve. Exception: In existing buildings, fixtures above the elevation of the fresh air inlet termination manhole cover of the next upstream manhole in the public sewer shall not be prohibited from discharging through a backwater valve. Note: For building sub-drains that service fixtures below the fresh air inlet termination that discharges into the building gravity drainage system by automatic pumping equipment, the required check valve installed with the pump shall provide sufficient means of protection against backflow. * * * SECTION 715 VACUUM DRAINAGE SYSTEMS * * * 715.2 System design. Vacuum drainage systems shall be designed in accordance with the vacuum drainage system manufacturer's instructions. The system layout, including piping layout, tank assemblies, vacuum pump assembly and other components necessary for proper function of the system shall be in accordance with the manufacturer’s instructions. Plans, specifications and other data for such systems shall be submitted to the code official for review and approval prior to installation. * * * P-715.2.5 Materials. Vacuum drainage pipe, fitting and valve materials shall be in accordance with the vacuum drainage system manufacturer’s instructions and the requirements of this chapter and supersede the requirements contained in Section 702. * * * SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS P-716.1 General. This section shall govern the replacement of existing building sewer and building (house) drainage piping by pipe-bursting methods and shall not extend past the curb line. P-716.2 Applicability. The replacement of existing building sewers and building (house) drainage piping by pipe-bursting methods shall be limited to gravity drainage piping of sizes 6 inches (152 mm) in diameter and larger smaller. The replacement piping shall be of the same nominal size as the existing piping. A plumbing permit shall be issued by the Department of Licenses and Inspections for this work and the work shall be properly inspected. Proof satisfactorily to the Department shall be provided that the PA One Call and any other applicable agency has been properly notified prior to issuing a permit for this work. P-716.3 Pre-installation inspection. The existing piping sections to be replaced shall be inspected internally by a recorded video camera survey and the existing pipe to be replaced shall be introduced with water to identify any imperfections in alignment. The survey shall include notations of the position of cleanouts and the depth of connections to the existing piping. P-716.4 Pipe. The replacement pipe shall be made of high-density polyethylene (HDPE) and shall have a standard dimension ratio (SDR) of 17. The pipe shall be in compliance with ASTM F714 and shall conform to the manufacturer’s specifications and guidelines for installation and use. P-716.5 Pipe fittings. Pipe fittings to be connected to the replacement pipe shall be made of high-density polyethylene (HDPE) and shall be in compliance with ASTM D2683 and shall conform to the manufacturer’s specifications and guidelines for installation and use. P-716.6 Cleanouts. Where the existing building sewer or building (house) drain did not have cleanouts meeting the requirements of this code, cleanout fittings shall be installed as required by this code. P-716.7 Post-installation inspection. The completed replacement piping section shall be inspected internally by a recorded video camera survey and the existing pipe to be replaced shall be introduced with water to identify any imperfections in alignment that would not allow for approval of the installation. The video survey shall be reviewed and approved or disapproved by the code official prior to pressure testing of the replacement piping system. * * * SECTION P-717 PRIVATE SANITARY SEWER INFRASTRUCTURE P-717.1 General. The provisions of this Section shall govern the materials, design, and construction of Private Sanitary Sewer Infrastructure. P-717.1.1 Definitions. The following definitions shall apply to Private Sanitary Sewer Infrastructure. PRIVATE SEWER INFRASTRUCTURE. The sewer pipe that is constructed on private property between the Lateral and the Building Sewer owned and maintained by the unit owner’s association to serve some or all units within a Condominium or Planned Community. Sanitary. Private sewer infrastructure that conveys sewage only. Storm. Private sewer infrastructure that conveys storm water or other drainage, but not sewage. P-717.2 Materials. Private Sanitary Sewer Infrastructure shall conform to all of the requirements listed in Section 702 of this code. P-717.3 Slope of private sanitary sewer infrastructure. Private sanitary sewer infrastructure shall be installed in uniform alignment at uniform slopes. The slope of private sanitary sewer infrastructure shall be in accordance with Section 704 of this code. P-717.4 Connections. The building sewers for each house or structure shall be connected to the Private Sanitary Sewer Infrastructure separately. Each connection shall be made with a wye branch and be fitted with a Building Trap and Fresh Air Inlet in line with the connection point in accordance with the Section 1002.6 of this code. P-717.5 Depth of private sanitary sewer infrastructure. Private Sanitary Sewer Infrastructure shall be installed not less than 36 inches (914 mm) measured from the top of pipe. P-717.6 Access for repairs. Separation of Private Water, Sanitary Sewer, and Storm Sewer Infrastructure placed in the same alignment and at a depth not exceeding 5 feet shall comply with Section 603.2 of this code. Infrastructure placed at depths greater than 5 feet shall be horizontally separated at a distance that allows for the approved sheeting and shoring and not less than 2 feet. P-717.7 Protection of structures. Private sanitary sewer infrastructure piping installed parallel to footings and walls shall not extend into the bearing plane of a footing or wall in accordance with Section 307.5 of this code. Private sanitary sewer infrastructure piping shall not be installed within 5 feet (1524 mm) of any adjoining property line. Private sanitary sewer infrastructure Pipe shall not be installed within 3 feet (914 mm) of any parallel building foundation. P-717.8 Cleanouts required. Cleanouts shall be provided for Private Sanitary Sewer Infrastructure in accordance with the provisions of this code for sanitary drainage pipe in Section 708.1. All building sewers connected to Private Sanitary Sewer Infrastructure shall be fitted with an approved Building Trap and Fresh Air Inlet. The sewer will not require a trap and Fresh Air Inlet at the connection to the lateral but will require a manhole or cleanout at the property line before entering the public right-of-way. P-717.9 Manholes. Manholes will be required for Private Sanitary Sewer Infrastructure 8 inches in diameter and greater at changes in direction, grade, and size. All manholes shall have inverts built with channels extending up to the pipe crown to ensure uniform flow in accordance with Section 708.1 of this code. P-717.10 Sewage Backflow. Backwater valves shall be installed in accordance with Section 714.1 of this code. P-717.11 Easement required. Private Sanitary Sewer Infrastructure shall require an easement with a minimum width of 12' and must provide adequate space to replace/repair the private services. Minimum vertical drive height clearance of 13'-6" or 2x pipe depth to pipe bottom, whichever is greater, shall be provided. SECTION P -718 RELINING BUILDING SEWERS REHABILITATION OF BUILDING SEWERS AND BUILDING DRAINS P-718.1 717.1 General. This section shall govern the relining of existing building sewers and building drainage piping for one- and two-family dwellings. Relining of building sewers for commercial occupancies is prohibited. P-718.2 717.2 Applicability. The relining of existing building sewers and building drainage piping shall be limited to gravity drainage piping 4 inches (102 mm) in diameter and larger. The relined piping shall be of the same nominal size as the existing piping. P-718.3 717.3 Preinstallation requirements. Prior to commencement of the relining installation, the existing piping sections to be relined shall be descaled and cleaned. After the cleaning process has occurred and water has been flushed through the system, the piping shall be inspected internally by a recorded video camera survey. P-718.3.1 717.3.1 Preinstallation recorded video camera survey. The video survey shall include verification of the project address location. The video shall include notations of the cleanout and fitting locations, and the approximate depth of the existing piping. The video shall also include notations of the length of piping at intervals not greater than 25 feet (7620 mm). P-718.4 717.4 Permitting. A plumbing permit shall be issued by the Department of Licenses and Inspections for this work and the work shall be properly inspected. Proof satisfactory to the Department shall be provided showing that the PA One Call and any other applicable agency has been properly notified prior to issuing a permit for this work. Prior to permit issuance, the code official shall review and evaluate the preinstallation recorded video camera survey to determine if the piping system is capable to be of being relined in accordance with the proposed lining system manufacturer’s installation requirements and applicable referenced standards. P-718.5 717.5 Prohibited applications. Where review of the preinstallation recorded video camera survey reveals that piping systems are not installed correctly or defects exist, relining shall not be permitted. The defective portions of piping shall be exposed and repaired with pipe and fittings in accordance with this code. Defects shall include, but are not limited to, backgrade or insufficient slope, complete pipe wall deterioration or complete separations such as from tree root invasion or improper support. P-718.6 717.6 Relining materials. The relining materials shall be manufactured in compliance with applicable standards and certified as required in Section 303. Fold-and-form pipe reline materials shall be manufactured in compliance with ASTM F1504 or ASTM F1871. P-718.7 717.7 Installation. The installation of relining materials shall be performed in accordance with the manufacturer's installation instructions, applicable referenced standards and this code. P-718.7.1 717.7.1 Material data report. The installer shall record the data as required by the relining material manufacturer and applicable standards. The recorded data shall include but is not limited to the location of the project, relining material type, amount of product installed and conditions of the installation. A copy of the data report shall be provided to the code official prior to final approval. P-718.8 717.8 Post-installation recorded video camera survey. The completed, relined piping system shall be inspected internally by a recorded video camera survey after the system has been flushed and flow-tested with water. The video survey shall be submitted to the code official prior to finalization of the permit. The video survey shall be reviewed and evaluated to provide verification that no defects exist. Any defects identified shall be repaired and replaced in accordance with this code. P-718.9 717.9 Certification. A certification shall be provided in writing to the code official, from the permit holder, that the relining materials have been installed in accordance with the manufacturer’s installation instructions, the applicable standards and this code. P-718.10 717.10 Approval. Upon verification of compliance with the requirements of Sections P-718.1 717.1 through P-718.9 717.9, the code official shall approve the installation. SECTION P-719 REHABILITATION OF BUILDING SEWERS P-719.1 718.1 Cure-in-place. Sectional cure-in-place rehabilitation of building sewer piping and sewer service lateral piping shall be in accordance with ASTM F2599 and shall be limited to one- and two- family dwellings. Hydrophilic rings or gaskets in cure-in-place rehabilitation of building sewer piping and sewer service lateral piping shall be in accordance with ASTM F3240 to ensure water tightness and elimination of ground water penetration. P-719.2 Applicability. The cure-in-place rehabilitation of existing building sewer piping shall be limited to gravity drainage piping 4 inches (102 mm) in diameter and larger. The cure-in-place rehabilitation piping shall be of the same nominal size as the existing piping. P-719.3 Preinstallation requirements. Prior to commencement of the cure-in-place rehabilitation installation, the existing piping sections to be rehabilitated shall be descaled and cleaned. After the cleaning process has occurred and water has been flushed through the system, the piping shall be inspected internally by a recorded video camera survey. P-719.3.1 Preinstallation recorded video camera survey. The video survey shall include verification of the project address location. The video shall include notations of the cleanout and fitting locations, and the approximate depth of the existing piping. The video shall also include notations of the length of piping at intervals not greater than 25 feet (7620 mm). P-719.4 Permitting. A plumbing permit shall be issued by the Department of Licenses and Inspections for this work and the work shall be properly inspected. Proof satisfactory to the Department shall be provided that the PA One Call and any other applicable agency has been properly notified prior to issuing a permit for this work. Prior to permit issuance, the code official shall review and evaluate the preinstallation recorded video camera survey to determine if the piping system is capable of being relined in accordance with the proposed rehabilitation system manufacturer’s installation requirements and applicable referenced standards. P-719.5 Prohibited applications. Where review of the preinstallation recorded video camera survey reveals that piping systems are not installed correctly or defects exist, rehabilitation shall not be permitted. The defective portions of piping shall be exposed and repaired with pipe and fittings in accordance with this code. Defects shall include, but are not limited to, backgrade or insufficient slope, complete pipe wall deterioration or complete separations such as from tree root invasion or improper support. P-719.6 Cure in place rehabilitation materials. The rehabilitation materials shall be manufactured in compliance with applicable standards and certified as required in Section 303. P-719.7 Installation. The installation of cure in place rehabilitation materials shall be performed in accordance with the manufacturer’s installation instructions, applicable referenced standards and this code. P-719.7.1 Material data report. The installer shall record the data as required by the cure in place rehabilitation material manufacturer and applicable standards. The recorded data shall include, but is not limited to, the location of the project, rehabilitation material type, amount of product installed and conditions of the installation. A copy of the data report shall be provided to the code official prior to final approval. P-719.8 Post-installation recorded video camera survey. The completed, rehabilitated piping system shall be inspected internally by a recorded video camera survey after the system has been flushed and flow-tested with water. The video survey shall be submitted to the code official prior to finalization of the permit. The video survey shall be reviewed and evaluated to provide verification that no defects exist. Any defects identified shall be repaired and replaced in accordance with this code. P-719.9 Certification. A certification shall be provided in writing to the code official, from the permit holder, that the cure in place rehabilitation relining materials have been installed in accordance with the manufacturer’s installation instructions, the applicable standards and this code. P-719.10 Approval. Upon verification of compliance with the requirements of Sections P-719.1 through P-719.9, the code official shall approve the installation. CHAPTER 8 INDIRECT/SPECIAL WASTE * * * SECTION 802 INDIRECT WASTES 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dishwashing machines and utensils, pots, pans and dishwashing sinks shall discharge through an indirect waste pipe as specified in Sections 802.1.1 through 802.1.7. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. P-802.1.1 Food handling. Equipment and fixtures utilized for the storage, preparation and handling of food and ice, including bars sinks, shall discharge through an indirect waste pipe by means of an air gap. Each well of a multiple-compartment sink shall discharge independently to a waste receptor. * * * P-802.1.4 Swimming pools. Where wWaste water from swimming pools, backwash from filters shall discharge to the sanitary drainage system and water from pool deck drains discharge to the building sanitary drainage system. , the Swimming pool waste water discharge and pool deck drains shall be through an indirect waste pipe by means of an air gap. P-802.1.5 Nonpotable clear-water waste. Where devices and equipment such as process tanks, filters, drips and boilers discharge nonpotable water to the building drainage system, the discharge shall be through an indirect waste pipe by means of an air break or an air gap. Note: This waste may discharge on to a roof and into the storm system. * * * P-802.1.7 Food utensils, dishes, pots and pans sinks. Sinks, in other than dwelling units, used for the washing, rinsing or sanitizing of utensils, dishes, pots, pans or service ware used in the preparation, serving or eating of food shall discharge indirectly through an air gap or an air break to the drainage system. Exception: Fixtures not used for food preparation are permitted to be directly connected to the drainage system. * * * P-802.4 Waste receptors. For other than hub drains that receive only clear-water waste and standpipes, a removable strainer or basket shall cover the outlet of waste receptors. Waste receptors shall not be installed in concealed spaces. Waste receptors shall not be installed in plenums, crawl spaces, attics, interstitial spaces above ceilings and below floors. Ready access shall be provided to waste receptors. For the purpose of this section, a mop/slop sink shall be considered a waste receptor for clear water waste only. * * * P-802.4.2 Hub drains and floor sinks. A hub drain shall be in the form of a hub or a pipe extending not less than 1 inch (25 mm) above a water-impervious the finished floor. Floor sinks shall be set not less than 1 inch (25 mm) above the finished floor to the flood level rim. * * * SECTION 803 SPECIAL WASTES P-803.1 Neutralizing device required for corrosive wastes. Corrosive liquids, spent acids or other harmful chemicals that destroy or injure a drain, sewer, soil or waste pipe, or create noxious or toxic fumes or interfere with sewage treatment processes shall not be discharged into the plumbing system without being thoroughly diluted, neutralized or treated by passing through an approved dilution or neutralizing device. Such devices shall be automatically provided with a sufficient supply of diluting water or neutralizing medium so as to make the contents noninjurious before discharge into the drainage system. The nature of the corrosive or harmful waste and the method of its treatment or dilution shall be approved prior to installation. All discharges into the public sewers are subject to regulation by the Philadelphia Water Department. The Philadelphia Water Department prohibits the discharge of any corrosive liquids, including but not limited to spent acids or other harmful chemicals that destroy or injure a drain, sewer, soil or waste pipe, or create noxious or toxic fumes or interfere with sewage treatment processes. Where treatment prior to discharge is required, liquids shall not be discharged into the plumbing system without being thoroughly neutralized or treated in compliance with Philadelphia Water Department regulations. * * * P-803.3 Radioactive waste. No waste containing radioactive substances shall be discharged into any portion of a plumbing system, unless so treated or handled as the Department of Public Health prescribes by regulation to prevent public health hazard. CHAPTER 9 VENTS SECTION 901 GENERAL * * * 901.2 Trap seal protection. * * * P-901.2.2 Relief Vent. A relief vent pipe shall be installed on the building (house) drain before the main building (house) trap inside the building and be connected to the nearest vent line for any building 75 feet or higher. On building (house) drains of 8 inches or less, the vent shall be a minimum of 4 inches. On building (house) drains 10 inches and over, the relief vent shall be a minimum of 5 inches. * * * P-901.3 Chemical waste vent systems. The vent system for a chemical waste system shall be independent of the sanitary vent system and shall terminate separately through the roof to the outdoors or to an air admittance valve that complies with ASSE 1049. Air admittance valves for chemical waste systems shall be constructed of materials approved in accordance with Section 702.5 and shall be tested for chemical resistance in accordance with ASTM F1412. * * * SECTION 903 VENT TERMINALS 903.1 Roof extension. The vent pipe shall terminate by extending to the outdoors through the roof or the side wall in accordance with one of the methods identified in Sections 903.1.1 through 903.1.4. P-903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall be terminated not less than [NUMBER] 24 inches (610 mm) above the roof. * * * P-903.2 Reserved. Frost closure. Where the 97.5-percent value for outdoor design temperature is 0°F (- 18°C) or less, vent extensions through a roof or wall shall be not less than 3 inches (76 mm) in diameter. Any increase in the size of the vent shall be made not less than 1 foot (305 mm) inside the thermal envelope of the building. * * * SECTION 904 OUTDOOR VENT EXTENSIONS * * * P-904.3 Vent termination. Vent stacks or stack vents shall terminate outdoors to the open air or to a stack-type air admittance valve in accordance with Section 918. * * * SECTION 905 VENT CONNECTIONS AND GRADES P-905.1 Connection. Individual, branch and circuit vents shall connect to a vent stack, stack vent, air admittance valve or extend to the open air. * * * P-905.6 Vent for future fixtures. Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent shall be installed. The vent size shall be not less than one-half the diameter of the rough-in drain to be served or a full-size vent when serving drainage piping as part of a single- stack vent system. The vent rough-in shall connect to the vent system, or shall be vented by other means as provided for in this chapter. The connection shall be identified to indicate that it is a vent. * * * SECTION 915 COMBINATION WASTE AND VENT SYSTEM P-915.1 Type of fixtures. A combination waste and vent system shall not serve fixtures other than floor drains, sinks, lavatories and drinking fountains. Combination waste and vent systems shall not receive the discharge from a food waste disposer or clinical sink. * * * SECTION 917 SINGLE-STACK VENT SYSTEM * * * P-917.6 Additional venting required. Additional venting shall be provided where more than one water closet discharges to a horizontal branch and where the distance from a fixture trap to the stack exceeds the limits in Section 917.4. Where additional venting is required, the fixture(s) shall be vented by individual vents, common vents, wet vents, circuit vents, or a combination waste and vent pipe. The dry vent extensions for the additional venting shall connect to a branch vent, vent stack, stack vent, air admittance valve, or shall terminate outdoors. * * * SECTION 918 AIR ADMITTANCE VALVES P-918.1 General. Vent systems utilizing air admittance valves shall comply with this section. Stack-type air admittance valves shall conform to ASSE 1050. Individual and branch type air admittance valves shall conform to ASSE 1051. Air admittance valves shall be allowed for permitted alterations to the plumbing system in one- and two-family dwellings in place of an individual vent for a single fixture drain other than a water closet or any other soil waste. * * * P-918.3 Where permitted. An individual, branch and circuit vents shall be permitted to terminate with a connection to an individual or branch-type air admittance valve in accordance with Section P-918.3.1. Stack vents and vent stacks shall be prohibited permitted to terminate to stack-type air admittance valves in accordance with Section P-918.3.2. P-918.3.1 Horizontal branches. Individual and branch-type air admittance valves shall vent only a single fixtures that are is on the same floor level and connected to a horizontal branch drain or vertical waste stack. Where the horizontal branch is located more than four branch intervals from the top of the stack, the horizontal branch shall be provided with a relief vent that shall connect to a vent stack or stack vent, or extend outdoors to the open air. The relief vent shall connect to the horizontal branch drain between the stack and the most downstream fixture drain connected to the horizontal branch drain. The relief vent shall be sized in accordance with Section 906.2 and installed in accordance with Section 905. The relief vent shall be permitted to serve as the vent for other fixtures. P-918.3.2 Stack. Stack-type air admittance valves shall be prohibited from serving as the vent terminal for vent stacks or stack vents that serve drainage stacks having more than six branch intervals. P-918.4 Location. Individual and branch-type air admittance valves shall be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented. Stack-type air admittance valves shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture being vented. The air admittance valve shall be located within the maximum developed length permitted for the vent. The air admittance valve shall be installed not less than 6 inches (152 mm) above insulation materials. * * * P-918.8 Prohibited installations. Air admittance valves shall not be installed in nonneutralized special waste systems as described in Chapter 8 except where such valves are in compliance with ASSE 1049, are constructed of materials approved in accordance with Section 702.5 and are tested for chemical resistance in accordance with ASTM F1412. Air admittance valves shall not be located in spaces utilized as supply or return air plenums. Air admittance valves shall not be used to vent sumps or tanks except where the vent system for the sump or tank has been designed by an engineer. Air admittance valves shall not be installed on outdoor vent terminals for the sole purpose of reducing clearances to gravity air intakes or mechanical air intakes. Air admittance valves shall not be used in any other applications other than described in P-918.1. [Delete Section 919 and Replace as follows:] SECTION P-919 PHILADELPHIA SINGLE-STACK WASTE AND VENT SYSTEM P-919.1 Scope. The City of Philadelphia has the oldest known model plumbing code in the country dating back to June 30, 1885. Since the inception of the Philadelphia Plumbing Code, one of the main characteristics and theories has been the single stack method of waste and vent. This code and the single stack theory has stood the test of time and continues today to be a model code copied by many other codes as a base line. Every building and structure in the City of Philadelphia as of this writing has been built incorporating this methodology of the single stack theory. This section is intended to be used for any modification or rebuilding of any of these existing structures, homes or buildings or as an option for any planned new construction in the future. Systems utilizing this section shall not be permitted to incorporate any other methods of design contained in other sections of this code. P-919.2 Drainage system sizing. P-919.2.1 Fixture-unit values. The relative load weights of fixtures shall be determined in accordance with Table P-919.2(a). P-919.2.2 Values for fixtures not listed. Fixture unit values for fixtures that are not listed in Table P-919.2(a) and cannot be determined by similarity to a fixture listed therein shall be determined by Table P-919.2(b). P-919.2.2.1 Values for indirect waste receptor. The drainage fixture unit load of an indirect waste receptor receiving the discharge of indirectly connected fixtures shall be the sum of the drainage fixture unit values of the fixtures that discharge to the receptor, but not less than the drainage fixture unit value given for the indirect waste receptor in Table P-919.2(a) or Table P-919.2(b). P-919.2.2.2 Clear-water waste receptors. Where waste receptors such as floor drains, floor sinks and hub drains receive only clear-water waste from display cases, refrigerated display cases, ice bins, coolers and freezers, such receptors shall have a drainage fixture unit value of one half. P-919.2.3 Values for continuous flow. For a continuous or semi-continuous flow in a sanitary drainage system, such as from a bilge pump, ejector, air conditioning equipment, commercial laundry, dishwashing equipment, or similar device, each gallon per minute flow shall be deemed to be two fixture- units. P-919.2.4 Maximum fixture-unit load. The maximum number of fixture-units connected to a given size of house drain, horizontal branch, or vertical soil or waste stack, shall be determined by Table P-919.2(c). P-919.2.5 Soil stack size. The size of a soil or waste stack is determined by the fixture units on the stack plus the fixture units on the horizontal branch from the base of the soil or waste stack connected to the building drain. P-919.2.6 Horizontal branch size. The size of all horizontal branch lines including the horizontal branch from the base of the soil or waste stack connected to the building drain is determined by the fixture units and gradient fall. P-919.2.7 Building drain/building sewer size. The size of the building drain is determined by its gradient fall and total number of fixture units. P-919.2.8 Fall for small piping. Horizontal drainage piping of 3-inch diameter and less shall be installed with a fall of not less than 1/4 inch per foot. P-919.2.9 Fall for large piping. Horizontal drainage piping of more than 3 inches and up to and including 6 inches in diameter shall be installed with a fall not less than 1/8 inch per foot. Horizontal drainage piping larger than 6-inch diameter shall be installed with a fall of not less than 1/16 inch per foot. P-919.2.10 High-rise buildings. If a vertical soil or waste stack is 75 feet (23 m) in height and not more than 160 feet (49 m) in height, the vertical soil or waste stacks connected to the house drain or to any of its branches shall be one size larger than given in Table P-919.2(c), and this shall also apply when the soil or waste stacks are connected to a horizontal branch pipe that discharges into a soil or waste stack. If a vertical soil or waste stack is more than 160 feet in height, the vertical soil or waste stacks connected to the house drain or to any of its branches shall be two sizes larger than given in Table P-919.2(c), and this shall also apply when the vertical soil or waste stacks are connected to the horizontal branch pipe that discharges into a soil or waste stack. The size of the main soil stack shall be sized according to the largest branch entering the stack, except if the amount of fixture units requires a larger size. The developed length of the soil or waste stacks shall be determined by measuring the distance between the center line of the horizontal branch pipe and to an elevation 6" above the flood level rim of the highest fixture. If a relief vent is installed on all horizontal branches below the highest fixture and between the soil or waste stacks and the first fixture on the horizontal branch, the soil or waste stack sizes shall be in accordance with Table P-919.2(c), regardless of the height of the soil or waste stack. The diameter of a relief vent shall not be less than one-half the diameter of the horizontal branch to which it is connected, with a minimum size of 1-1/2 inches (38 mm). The maximum number of fixture units connected to the relief vent shall be in accordance with Table P-919.9(a). The size of the branch line and its stack shall be determined by the developed length of the stack. TABLE P-919.2(a) FIXTURE UNIT VALUES Fixtures | Private Installations | Public Installations | Minimum Trap Sizes (Inches) Fixtures | Private Installations | Public Installations | Minimum Trap Sizes (Inches) Bathroom group consisting of 1 lavatory, 1 water closet, 1 bathtub or shower stall | 6 | – | – Bathtub with 1-1/2 inch trap a | 2 | 3 | 1-1/2 Bathtub with 2-inch trap a | 3 | 4 | 2 Cup Sink | – | 2 | 1-1/4 Dishwashers, domestic, automatic | 4 | – | 1-1/2 c Drinking fountain | – | 1/2 | 1-1/4 Floor drain | 3 | 3 | 3 Kitchen sink with 1-1/2 inch trap b | 3 | 3 | 1-1/2 Kitchen sink with 2 inch trap b | – | 4 | 2 Laundry tray with 1-1/2 inch trap (1 or 2 compartment) | 3 | 3 | 1-1/2 Laundry tray with 2 inch trap | – | 4 | 2 Lavatory with 1-1/4 inch or 1-1/2 inch trap | 1 | 2 | 1-1/4 Lavatory, barber, beauty parlor, or surgeons | – | 3 | 1-1/2 Service sink (slop sink), mop receptor | – | 3 | 3 Service sink, flushing rim with flush valve | – | 6 | 3 Shower stall with 1-1/2 inch or 2 inch trap | 2 | 3 | 1-1/2 Shower stall with required 3 inch trap | – | 6 | 3 Urinal, stall and washout | – | 2 | 1-1/2 Urinal, pedestal, siphon-jet and blow-out | – | 4 | 2 Urinal, non-water | – | 1 | 1-1/2 Wash fountain, duo | – | 2 | 2 Wash fountain, any other size | – | 5 | 2 Washing machine, domestic, automatic | 4 | – | 2 Water closet | 3 | 6 | 3 Fountain cuspidor (dental chair) | – | 1 | 1-1/4 Sink, soda fountain or bar | – | 2 | 1-1/2 | | | For SI: 1 inch = 25.4 mm a. With or without shower head over bathtub. b. With or without garbage grinder unit, or dishwasher, in sink with 1-1/2 or 2 inch trap. c. Commercial dishwasher shall include minimum 2-inch trap. TABLE P-919.2(b) OTHER FIXTURE VALUES Required Fixture Drain or Trap Size | Fixture Unit Value Private Installations | Public Installations 1-1/4 inch | 1 | 2 1-1/2 inch | 2 | 3 2 inch | 3 | 4 3 inch | 4 | 6 4 inch | 4 | 8 TABLE P-919.2(c) MINIMUM PIPE SIZES ACCORDING TO FIXTURE LOAD (Maximum Fixture-Units that may be connected) House Drain or Horizontal Branch | Vertical Soil or Waste Stack Pipe size (Inches) | 1/16" Fall | 1/8" Fall | 1/4" Fall | 1/2" Fall House Drain or Horizontal Branch | Vertical Soil or Waste Stack Pipe size (Inches) | 1/16" Fall | 1/8" Fall | 1/4" Fall | 1/2" Fall 1-1/4 | | | 2 | 2 | 1-1/2 | | | 4 | 6 | 6 2 | | | 10 | 18 | 20 2-1/2 | | | 27 | 36 | 36 3 | | | 48 a | 65 a | 75 b 4 | | 50 | 100 | 200 | 225 5 | | 130 | 225 | 420 | 480 6 | | 330 | 480 | 875 | 1,015 8 | 500 | 850 | 1,100 | 2,000 | 2,320 10 | 1,050 | 1,650 | 2,320 | 3,800 | 4,500 12 | 1,800 | 3,000 | 4,500 | 6,500 | 8,100 15 | 3,600 | 6,000 | 8,100 | 10,000 | 13,600 | | | | | Note a: Limit 2 water closets. Note b: Limit 6 water closets. P-919.2.11 Minimum size of soil and waste pipe. No soil or waste stack shall be smaller than the largest branch draining into it regardless of the height of the building. Soil stacks receiving the discharge of water closets shall not be less than 3 inches in diameter, as provided in Table P-919.2(c). Three-inch soil stacks shall be limited to six water closets. No horizontal soil pipe or waste pipe draining water closets shall be less than 3 inches in diameter. When using 3-inch ideal bends (closet bends) to receive the discharge of water closets, this fitting shall be a blind bend containing no drainage connections for other fixtures. No waste pipe shall be less than 1-1/4 inches in diameter. P-919.2.12 Building drain/building sewer. The minimum size of the main house drain receiving the discharge of water closets shall be 4 inches inside nominal diameter. P-919.3 Venting. P-919.3.1 Required. All fixtures shall be adequately vented to prevent siphonic action and to protect trap seals. P-919.3.2 Connection. The seal of every fixture trap in a plumbing system shall be protected by being individually connected to a properly vented drain. Exception: Leader traps, area drain traps, and yard drain traps. P-919.3.3 Stack vents. Every soil or waste stack shall be extended vertically, full size, as a stack vent to open air. P-919.3.4 Vent stacks. A vent stack or main vent shall be installed with a soil or waste stack when relief vents or other branch vents are required in more than five branch intervals. The vent stack shall terminate independently in the open air above the roof or shall be connected with the stack vent at least 6 inches above the flood level rim of the highest fixture and shall connect with the soil or waste stack through, at, or below the lowest horizontal soil or waste branch, or with the house drain, in such manner as to prevent the accumulation of rust scale. When water closets are installed on this lowest horizontal branch, they shall be connected to the side of the horizontal branch. P-919.3.5 Vent required. Every building in which plumbing is installed shall have at least one stack vent or vent stack which shall be equal in size of the diameter of the building sewer and shall run undiminished in size as directly as possible from the building sewer through to the open air above the roof. The minimum size of the stack vent or vent stack shall be 4" (102 mm). P-919.4 Velocity breaks in soil or waste stacks over 300' in height. P-919.4.1 Required. Velocity breaks shall be required in soil or waste stacks over 300 feet in height to impede the velocity of the waste. At each velocity break, the stack shall be offset by two 45-degree breaks. A relief vent one-half the size of the soil stack shall be installed at the top of the second 45-degree break and shall be connected to the nearest vent stack. P-919.4.2 Intervals. Velocity breaks shall be installed on any floor level within the first ten stories of the soil or waste stack and at intervals of not more than 20 stories above the lowest velocity break and each break thereafter. P-919.4.3 Relief vent. A relief vent pipe shall be installed on the main drain before the main house trap inside the building and be connected to the nearest vent line for any building 75 feet or higher. On main drains of 8 inches or less, the vent shall be a minimum of 4 inches. On main drains 10 inches and over, the relief vent shall be a minimum of 5 inches. P-919.5 Ventilation of branch or horizontal pipes. P-919.5.1 Vent required. Every branch, horizontal soil pipe, or waste pipe to which a group of two or more fixtures is to be connected shall have a vent of the same size as the branch by: extending the branch full size as through the roof; connecting to the stack vent 6 inches above the highest fixture; or connecting to the vent stack 6 inches above the highest fixture connected to the branch. The horizontal branch from the base of a stack shall be connected to the building drain.) P-919.5.2 Alternatives. Where the center of a water closet outlet is not more than 48 inches in developed length from the center of 4-inch vented soil pipe on a vertical line, or through a wye or wye and 1/8 bend on a vented horizontal line, connection of small fixture wastes – not exceeding two that are 1-1/2 inches or less in diameter – to the side of an ideal bend (closet bend) above the center line without an additional vent, or by using no-hub, copper, ABS or PVC pipe and fittings. Where the center of a water closet outlet is not more than 18 inches from the center of a 3-inch vented soil pipe and the 4-inch ideal bend (closet bend) is connected directly to a sanitary tee on a vertical line, connection of small fixture wastes – not exceeding two that are 1-1/2 inches or less in diameter – to the sides of the bend above the center line without an additional vent and in accordance with Section P-919.2.11. As an alternative to increasing the size of a stack from 3 inches to 4 inches, a merion/stack tee fittings shall be used to receive the discharge of a water closet and small fixture wastes. P-919.5.3 Merion/stack tee fittings. The water closet soil line connected to a merion/stack tee fittings shall be a maximum of 8 feet developed length. The ideal bend (closet bend) shall not be less than 4 inches nominal diameter when receiving the discharge of small fixture wastes. When using 3-inch ideal bends (closet bend) to receive discharges of water closets, this fitting shall be a blind bend containing no drainage connections for other fixtures. P-919.5.4 Existing stacks in buildings where the center of a water closet outlet is more than 4 feet but not more than 8 feet from the center of a vented soil pipe, an additional 1-1/2-inch vent will be permitted if the vent is no longer than 30 feet, provided the conditions are the same as in Section P-919.5.3. P-919.6 Fixture venting. P-919.6.1 Minimum vent size. Any single water closet branch more than 8 feet in length or waste branch for fixtures other than water closets more than 12 feet in length shall have a vent sized at least one-half the diameter of the branch pipe. Depending on its length, the number of fixture units connected shall be in accordance with Table P-919.9(a). P-919.7 Venting of offsets. P-919.7.1 Stack offsets. Offsets in soil or waste stacks at an angle greater than 45 degrees from the vertical serving fixtures above the offset shall be vented as provided in Sections P-919.7.2 or P-919.7.3. P-919.7.2 Yoke venting offsets. Such offsets shall be provided with a yoke vent equal to one-half the diameter of the vent stack or soil stack but not less than 1-1/2 inches (38 mm). The lower end of the yoke vent shall connect to the soil or waste stack through a wye below the offset and above the next lower horizontal branch, and the upper end shall connect to the stack vent or the vent stack not less than 6 inches (152 mm) above the highest fixture. The yoke vent may connect to a vent stack on the floor level above or higher provided the connection is a minimum of 6 inches (152 mm) above the flood level rim of the next fixture on the stack above the offset. P-919.7.3 Separate venting. Such offsets shall be vented as two separate soil or waste stacks, with the stack section below the offset and the stack section above the offset. P-919.7.4 Venting not required. All buildings of not more than three stories having a soil or waste stack with one offset at an angle greater than 45 degrees from the vertical and which does not exceed 10 feet in length shall not require additional venting. No fixtures shall be permitted above the offset, except that one small fixture may be installed for a heel wash. P-919.8 Vent headers. P-919.8.1 Vent header permitted. Stack vents and vent stacks shall be permitted to connect into a common vent header at the top of the stacks and extend to the open air above the roof at one point. Such header shall be sized in accordance with the requirements of Table P-919.9(a). As per Section P-919.5, the size of the horizontal branch entering a stack shall have a vent of the same size; therefore, one of the stacks entering into a common vent header shall be of the same size as the branch entering the stack and shall maintain that size through the roof. Other sizes of the header can then be sized as per Table P-919.9(a). P-919.8.2 Sizing. The number of fixture units considered in sizing the vent header shall be the sum of all fixture units on all stacks connected thereto. The developed length shall be the longest vent length from the intersection at the base of the most distant stack to the vent header terminal in the open air above the roof. The latter shall be extended to the open air above the roof as a direct extension of one stack. P-919.9 Size and length of vents. P-919.9.1 Length of vents. The length of a vent shall be its developed length from the lowest connection of the vent with the soil stack, waste stack, or house drain to the vent terminal above the roof. P-919.9.2 Size of stack vent. The diameter of a stack vent shall not be less than the diameter of the soil or waste stack of which it is an extension. P-919.9.3 Size of vent stacks. A vent stack or main vent connecting relief vents, circuit vents or loop vents shall have a diameter of at least one-half the diameter of the soil or waste stack to which the vent stack or main vent is connected, but in no case less than 1-1/2 inches (38 mm). The maximum number of fixture units connected to the vent stack shall be in accordance with Table P-919.9(a). The vent stack or main vent shall not be less in size than the branch, circuit, or loop vent it is servicing. Where fixtures are installed on the house drain behind the line of vent, a minimum vent stack of 1-1/2 inches (38 mm) shall be required for small fixtures having a fixture unit value not greater than 10 drainage fixture units and a minimum of a 2 inch (51 mm) vent for one or more water closets and other fixtures, except if a larger size is required according to Table P-919.9(a). P-919.9.4 Size of relief vent. The diameter of a relief vent shall not be less than one-half the diameter of the horizontal branch to which it is connected, with a minimum size of 1-1/2 inches. The maximum number of fixture units connected to the relief vent shall be in accordance with Table P-919.9(a). TABLE P-919.9(a) SIZE AND LENGTH OF VENTS Fixture Units Connected | Diameter of Vent (inches) – Maximum Length of Vent (feet) 1-1/2" | 2" | 2-1/2" | 3" | 4" | 5" | 6" | 8" Fixture Units Connected | Diameter of Vent (inches) – Maximum Length of Vent (feet) 1-1/2" | 2" | 2-1/2" | 3" | 4" | 5" | 6" | 8" 13 | 75 | 310 | | | | | | 26 | 70 | 300 | | | | | | 47 | 35 | 140 | 450 | | | | | 72 | 23 | 85 | 260 | 650 | | | | 98 | 18 | 75 | 240 | 600 | | | | 195 | | 30 | 95 | 240 | 1,000 | | | 293 | | 22 | 70 | 180 | 750 | | | 390 | | | 28 | 70 | 320 | 1,000 | | 624 | | | 20 | 50 | 240 | 750 | | 969 | | | | 20 | 95 | 240 | 1,000 | 1,320 | | | | 18 | 70 | 180 | 750 | 2,165 | | | | | 30 | 80 | 350 | 1,000 | | | | | | | | * * * CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS * * * SECTION 1002 TRAP REQUIREMENTS * * * P-1002.3 Prohibited traps. The following types of traps are prohibited: 1. Traps that depend on moving parts to maintain the seal. 2. Bell traps. 3. Crown-vented traps. 4. Traps not integral with a fixture and that depend on interior partitions for the seal, except those traps constructed of an approved material that is resistant to corrosion and degradation. 5. “S” traps. 6. Drum traps. Exception Exceptions: 1. Drum traps used as solids interceptors and drum traps serving chemical waste systems shall not be prohibited. 2. “S” traps are permitted to be used as a direct replacement to a previously installed “S” trap. 3. Traps with interior partitions serving chemical waste systems shall not be prohibited. * * * P-1002.4.1.5 Reserved. Fixture drain connection for trap priming. A fixture drain from a lavatory or hand sink shall serve as a method of providing trap seal protection for an emergency floor drain, a trench drain, or a floor sink where such fixtures are located in the same room. A fixture drain from a drinking fountain shall serve as a method of providing trap seal protection for an emergency floor drain, a trench drain, or a floor sink where such fixtures are in the same room or in a room adjacent to the room having the drinking fountain. The fixture drain shall not be routed on or above the surface of the floor and shall connect to the floor drain, trench drain, or floor sink at a point that is below the flood level rim and above the inlet to the trap of the receiving fixture. P-1002.6 Building (house) traps and fresh air inlets. Building (house)traps shall be prohibited. A building (house) trap shall be required for every building, structure or house with a building sewer connected to sanitary or combined sewer. A building (house) trap shall be located at the curb line of the building, structure or house that it is servicing. The building (house trap) shall not be less in size than the house drain pipe it traps, and in no case less than 5 inches for sanitary or combination sewers or 6 inches for storm sewers. No flex seal coupling shall be permitted. Fresh air inlets shall be 4 inches for 5-inch and 6-inch drains; 6 inches for 8-inch drains; two 6-inch vents for 10-inch drains with 8-inch standpipe; two 6-inch vents for 12-inch drains with 10-inch standpipe; two 6-inch vents for 15-inch drains with 10-inch standpipe. Where two fresh air inlets are used, connections shall be made by use of a wye on the standpipe. Vents larger than 6 inches shall not terminate at ground level. In lieu of multiple vents, use of “Shuster” type vent or equal, properly sized, shall be permitted. P-1002.6.1 Fresh air inlet location. Fresh air inlets shall lead to the outer air and open at a convenient point, on the footway in the front of the building or at the curb line and shall have a cover with openings at least three-fourths of the area of the pipe. In no case shall an air inlet open within 10 feet of any door, window, or fresh air intake for a heater or ventilation system. P-1002.6.2 Fresh air inlet requirements. Fresh air inlets shall be so arranged as to prevent the admission of sticks or other articles that would tend to obstruct the main trap. They shall be at least 1/4 inch in thickness and fastened with brass screws or bolts in order that the top can be removed if necessary, and the body shall be caulked fast to the upright pipe by a lead joint. Only approved air inlets shall be used. P-1002.6.3 Relief vent. A relief vent shall be installed on the building (house) drain before the main building (house) trap inside the building and be connected to the nearest vent line for any building 75 feet or higher. On building (house) drains of 8 inches or less, the vent shall be a minimum of 4 inches. On building (house) drains 10 inches and over, the relief vent shall be a minimum of 5 inches. * * * SECTION 1003 INTERCEPTORS AND SEPARATORS P-1003.1 Where required. Interceptors and separators shall be provided to prevent the discharge of oil, grease, sand and other substances harmful or hazardous to the public sewer, the private sewage system or the sewage treatment plant or processes. Interceptors and separators shall be connected to the sanitary sewer. P-1003.2 Approval. The size, type and location of each interceptor and of each separator shall be designed and installed in accordance with the manufacturer's instructions and the requirements of this section based on the anticipated conditions of use. Wastes that do not require treatment or separation shall not be discharged into any interceptor or separator. As an appurtenance contained within the plumbing system, the interceptor or separator shall not be limited by the material construction of the unit. 1003.3 Grease interceptors. Grease interceptors shall comply with the requirements of Sections 1003.3.1 through 1003.3.8. * * * P-1003.3.5 Hydromechanical grease interceptors, fats, oils and greases disposal systems and automatic grease removal devices. Hydromechanical grease interceptors shall be of semi-automatic design equipped with a full port type ball valve on the discharge side of the interceptor and a draw-off located in the grease accumulating chamber of the interceptor. Hydromechanical grease interceptors; fats, oils, and greases disposal systems and automatic grease removal devices shall be sized in accordance with ASME A112.14.3, ASME A112.14.4, ASME A112.14.6, CSA B481.3 or PDI G101. Hydromechanical grease interceptors; fats, oils, and greases disposal systems and automatic grease removal devices shall be designed and tested in accordance with ASME A112.14.3, ASME A112.14.4, CSA B481.1, PDI G101 or PDI G102. Hydromechanical grease interceptors; fats, oils, and greases disposal systems and automatic grease removal devices shall be installed in accordance with the manufacturer’s instructions. Where manufacturer’s instructions are not provided, hydromechanical grease interceptors; fats, oils, and greases disposal systems and automatic grease removal devices shall be installed in compliance with ASME A112.14.3, ASME A112.14.4, ASME A112.14.6, CSA B481.3 or PDI G101. P-1003.3.5.1 Grease interceptor capacity. Grease interceptors shall have the grease retention capacity indicated in Table P-1003.3.5.1 for the flow-through rates indicated with a minimum capacity of 20 gallons per minute of flow and 40 pounds of grease retention capacity. TABLE P-1003.3.5.1 CAPACITY OF GREASE INTERCEPTORS TOTAL FLOW-THROUGH RATING (gpm) | GREASE RETENTION CAPACITY (pounds) TOTAL FLOW-THROUGH RATING (gpm) | GREASE RETENTION CAPACITY (pounds) 4 | 8 6 | 12 7 | 14 9 | 18 10 | 20 12 | 24 14 | 28 20 | 40 25 | 50 35 | 70 50 | 100 75 | 150 100 | 200 | * * * P-1003.4 Oil separators required. At repair garages where floor or trench drains are provided, car washing facilities, factories where oily and flammable liquid wastes are produced and hydraulic elevator pits, oil separators shall be installed into which oil-bearing, grease-bearing or flammable wastes shall be discharged before emptying into the building drainage system or other point of disposal. Interceptors and separators shall be connected to the sanitary sewer. * * * P-1003.4.2 Oil separator design. Oil separators shall be listed and labeled, or designed in accordance with Sections 1003.4.2.1, and 1003.4.2.2 and P-1003.4.2.3. * * * P-1003.4.2.3 Tightness. Oil interceptors shall be constructed so as to be oil-tight and shall have easily removable water-tight and gas-tight covers. * * * P-1003.11 Hair interceptor. An approved hair interceptor shall be installed wherever hair is introduced into the drainage system in sufficient quantity to cause line stoppage and shall be installed in connection with the following uses or occupancies. P-1003.12 Plaster interceptor. A plaster interceptor is required on all types of sinks or plumbing fixtures where plaster, earthen or sedimentary materials are to be used. * * * CHAPTER 11 STORM DRAINAGE SECTION 1101 GENERAL 1101.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. P-1101.1.1 Private building storm sewer. Repairs to existing private building storm sewer pipe materials shall be in accordance with Table P-1102.4. New or extended private building storm sewers may not cross any adjoining property except when included as part of an approved post construction Storm Water Management Plan in accordance with Philadelphia Water Department regulations or private storm sewer infrastructure designed in accordance with Section P-1115. P-1101.2 Disposal. All Rrainwater from roofs and storm water from paved areas, yards, courts and courtyards shall drain to an approved place of disposal. For one- and two-family dwellings, and where approved, storm water is permitted to discharge onto flat pervious areas, such as streets or lawns, or area drains provided that the storm water flows away from the building. P-1101.2.1 Area drain. Area drains shall be provided on all premises in the locations required by items 1 through 6 below: 1. Paved areas, courts, open shafts in excess of 5,000 square feet. 2. Driveways of any area which slope downward toward the building. 3. Terrain which slopes downward toward the building within 10 feet of the building's exterior walls. 4. Terrain which creates a low elevation such that standing water is possible. 5. Terrain which slopes downward toward adjacent property in such a manner as to concentrate the flow of runoff. Exception: Where terrain slopes toward a natural watercourse such as a creek, stream or river, an area drain shall not be required. 6. At the low point of any swales on the property. Exception: Where terrain slopes toward a natural watercourse such as a creek, stream or river, an area drain shall not be required. * * * P-1101.3 Prohibited drainage. Storm water shall not be drained into sewers intended for sewage only. Exceptions: 1. Drains contained in enclosed parking garage not exposed to the outside climatic elements. 2. Drains receiving washdown, soil, oil, fat/grease or any other hazardous waste. * * * [BS]1 P-1101.7 Roof design. Roofs shall be designed for the maximum possible depth of water that will pond thereon as determined by the relative levels of roof deck and overflow weirs, scuppers, edges or serviceable drains in combination with the deflected structural elements. In determining the maximum possible depth of water, all primary roof drainage means shall be assumed to be blocked. The maximum possible depth of water on the roof shall include the height of the water required above the inlet of the secondary roof drainage means to achieve the required flow rate of the secondary drainage means to accommodate the design rainfall rate as required by Section 1106. Exception: Canopies, marquees, balconies, and similar extended roof surfaces with a total of 300 square feet or less, shall not require drainage unless the areas include a parapet. * * * P-1101.9 Backwater valves. Storm drainage systems shall be provided with backwater valves as required for sanitary drainage systems in accordance with Section 714. For building sub-drains that service fixtures below the fresh air inlet termination that discharges into the building gravity drainage system by automatic pumping equipment, the required check valve installed with the pump shall provide sufficient means of protection against backflow. Exception: Storm drainage systems and private on-site stormwater management systems located outside the 100-year floodplain or connected to the public storm sewer. SECTION 1102 MATERIALS P-1102.2 Inside storm drainage conductors. Inside storm drainage conductors installed above ground shall conform to one all of the requirements and standards listed in Table Section 702 702.1. P-1102.3 Underground building storm drain pipe. Underground building storm drain pipe shall conform to one all of the requirements and standards listed in Table Section 701 702.2. * * * TABLE P-1102.4 BUILDING STORM SEWER PIPE MATERIAL | STANDARD * * * Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 * * * Ductile iron pipe class 56 | AWWA C151/A21.51; AWWA C115/A21.15 * * * * * * TABLE P-1102.5 SUBSOIL DRAIN PIPE MATERIAL | STANDARD * * * Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 * * * * * * P-1102.6 Roof drains. Roof drains shall conform to ASME 112.3.1 or ASME A112.6.4. Roof drain materials shall comply with Sections P-1102.2 and P-702.1. Roof drains, other than siphonic roof drains, shall be tested and rated in accordance with ASME ASME A112.6.4 or ASPE/IAPMO Z1034. * * * SECTION 1103 TRAPS P-1103.1 Main trap. Leaders and storm drains connected to a combined sewer shall be trapped. Individual storm water traps shall be installed on the storm water drain branch serving each conductor, or a single trap shall be installed in the main storm drain just before its connection with the combined building sewer or the public sewer. A single hooded catch basin located within the property line shall be the equivalent of a building (house) trap for the connection to a street combined sewer. Leaders and storm drains connected to a building storm sewer shall not be required to be trapped. * * * P-1103.4 Cleanout. A cleanout shall be installed on the building side of the trap and shall be provided with access. A cleanout or a building storm sewer house trap shall be required on a dedicated storm sewer system where the building storm sewer connects at the curb. * * * SECTION 1106 SIZE OF CONDUCTORS, LEADER AND STORM DRAINS P-1106.1 General. The size of the vertical conductors and leaders, building storm drains, building storm sewers and any horizontal branches of such drains or sewers shall be based on a the 100-year hourly rainfall rate of 4.5" per hour. indicated in Figure 1106.1 or on other rainfall rates determined from approved local weather data. Exceptions: 1. Existing building storm drainage systems without secondary roof drainage installed in accordance with Section 1108 shall be designed based on a rainfall rate of 6" per hour. 2. The size of building storm drainage systems serving green roof systems, approved by the Philadelphia Water Department, shall be based on a rainfall rate of 3.1" per hour. [Delete Figure 1106.1] * * * SECTION 1107 SIPHONNIC ROOF DRAINAGE SYSTEMS P-1107.1 General. Siphonic roof drains and drainage systems shall be prohibited. designed in accordance with ASME A112.6.9 and ASPE 45. * * * SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER P-1109.1 General. Where the public sewer is a combined system for both sanitary and storm water, the storm sewer shall be connected independently to the lateral public sewer. Exception: The repair or replacement of an existing combined building sewer as of the initial adoption date of this code. P-1109.2 Size of the existing combined building drains and building sewers. The size of the existing combined building drains and building sewers when being replaced in kind shall not be less than 4" and not having a slope less than 1/8" per foot (1 percent). P-1109.3 Size of existing combined building drains and building sewers when adding additional load. The size of a combination sanitary and storm drain or sewer shall be computed in accordance with the method in Table P-1109.4. The fixture units shall be converted into an equivalent projected roof or paved area. Allowance in square feet of pitched roofs or paved areas for fixture units shall be as follows: 7 square feet for each of the first 1,500 Fixture Units; 5 square feet for each of the next 1,500 Fixture Units; 4 square feet for each of the next 2,000 Fixture Units; and 3 square feet for each Fixture Unit thereafter. These values are based on a rainfall rate of 6 inches (127 mm) per hour. TABLE P-1109.4 MAXIMUM HORIZONTAL PROJECTED ROOF AREA IN SQUARE FEET FOR BUILDING STORM DRAINS AT VARIOUS SLOPES Diameter (Inches) | Fall Per Foot | Vertical Leaders 1/8" | 1/4" | 1/2" Diameter (Inches) | Fall Per Foot | Vertical Leaders 1/8" | 1/4" | 1/2" 3 | | 930 | 1,300 | 1,750 4 | 1,585 | 2,100 | 3,300 | 3,650 5 | 2,875 | 3,800 | 5,300 | 6,000 6 | 4,300 | 6,000 | 9,000 | 10,800 8 | 9,200 | 13,000 | 18,000 | 23,000 10 | 16,500 | 25,000 | 35,000 | 40,000 12 | 26,600 | 40,000 | 60,000 | 65,000 15 | 47,500 | 75,000 | 100,000 | 115,000 16 | 57,250 | 92,500 | 131,000 | 18 | 67,000 | 110,000 | 162,000 | 20 | 85,500 | 135,000 | 196,000 | 24 | 155,000 | 225,000 | | 30 | 295,000 | 416,000 | | | | | | * * * SECTION 1113 SUMPS AND PUMPING SYSTEMS * * * P-1113.1.4 Piping. Discharge piping shall meet the requirements of Section 1102.2, 1102.3 or 1102.4 and shall include a gate full open valve and a full flow check valve. Pipe and fittings shall be the same size as, or larger than, the pump discharge tapping. Exception: In one- and two-family dwellings, only a check valve shall be required, located on the discharge piping from the pump or ejector. SECTION P-1114 SUSTAINABLE GREEN ROOF DRAINAGE SYSTEMS P-1114.1 General. A green roof drainage system receiving storm water discharge solely from a green roof shall be engineered in accordance with this section and the design, submittal, approval, inspection and testing requirements of Section 316.1. P-1114.2 Green roof design. Green roof designs shall comply with section 1101.7. Support for the weight of the green roof system shall be accounted for in the building structural design and prepared by a licensed design professional for all new building construction and alterations or retrofits to existing structures. P-1114.2.1 Green roof rainfall rates. The green roof drainage system shall be designed based on the reduced rainfall rate in accordance with Section 1106.1 only where approved through the Philadelphia Water Department and shall satisfy the design, installation and maintenance requirements set forth by the Philadelphia Water Department and, if applicable, the Philadelphia Zoning Code. P-1114.3 Green roof drains. Roof drains serving green roofs shall conform to requirements of Chapter 11 and be protected with a means to prevent sediment and debris from entering the storm drainage piping system, including provisions for roof drain access for general maintenance. SECTION P-1115 PRIVATE STORM SEWER INFRASTRUCTURE P-1115.1 General. The provisions of this section shall govern the materials, design, and construction of Private Storm Sewer Infrastructure. P-1115.1.1 Definitions. The following definitions shall apply to Private Storm Sewer Infrastructure. PRIVATE SEWER INFRASTRUCTURE. The sewer pipe that is constructed on private property between the Lateral and the Building Sewer owned and maintained by the Unit Owner’s Association to serve some or all units within a Condominium or Planned Community. SANITARY. Private sewer infrastructure that conveys sewage only. STORM. Private sewer infrastructure that conveys storm water or other drainage, but not sewage. P-1115.2 Materials. Private Storm Sewer Infrastructure shall conform to Table P-1102.4 of this code. P-1115.3 Slope of private storm sewer infrastructure. Private storm sewer infrastructure shall be installed in uniform alignment at uniform slopes. The slope of private storm sewer infrastructure shall be in accordance with Section 704 of this code. P-1115.4 Connections. The building storm sewers for each house or structure shall be connected to the Private Storm Sewer Infrastructure separately. P-1115.5 Depth of private storm sewer infrastructure. Private Storm Sewer Infrastructure shall be installed not less than 36 inches (914 mm) measured from the top of pipe. P-1115.6 Access for repairs. Separation of Private Water, Sanitary Sewer, and Storm Sewer Infrastructure placed in the same alignment and at a depth not exceeding 5-feet shall comply with Section 603.2 of this code. Infrastructure placed at depths greater than 5 feet shall be horizontally separated at a distance that allows for the approved sheeting and shoring and not less than 2 feet. P-1115.7 Protection of structures. Private storm sewer infrastructure installed parallel to footings and walls shall not extend into the bearing plane of a footing or wall in accordance with Section 307.5 of this code. Private storm sewer infrastructure shall not be installed within 5 feet (1524 mm) of any adjoining property line. Private storm sewer infrastructure Pipe shall not be installed within 3 feet ( 914 mm) of any parallel building foundation. P-1115.8 Cleanouts required. Cleanouts shall be provided for Private Storm Sewer Infrastructure in accordance with the provisions of this code for storm drainage pipe in Section 708.1. Where the public sewer is combined, all building sewers connected to Private Storm Sewer Infrastructure shall be fitted with an approved Building Trap and Fresh Air Inlet. The sewer will not require a trap and Fresh Air Inlet at the connection to the lateral but will require a manhole or cleanout at the property line before entering the public right-of-way. P-1115.9 Manholes. Manholes will be required for Private Storm Sewer Infrastructure 8 inches in diameter and greater at changes in direction, grade, and size. All manholes shall have inverts built with channels extending up to the pipe crown to ensure uniform flow in accordance with Section 708.1 of this code. P-1115.10 Storm backflow. Backwater valves shall be installed in accordance with Section 1101.9 of this code. For building sub-drains that service fixtures below the fresh air inlet termination that discharges into the building gravity drainage system by automatic pumping equipment, the required check valve installed with the pump shall provide sufficient means of protection against backflow. P-1115.11 Easement required. Private Storm Sewer shall require an easement with a minimum width of 12' and must provide adequate space to replace/repair the private services. Minimum vertical drive height clearance of 13'-6" or 2x pipe depth to pipe bottom, whichever is greater, shall be provided. * * * CHAPTER 13 NONPOTABLE WATER SYSTEMS SECTION 1301 GENERAL P-1301.1 General. The provisions of Chapter 13 shall govern the materials, design, construction and installation of systems for the collection, storage, treatment and distribution of nonpotable water. For nonpotable rainwater systems, the provisions of CSA B805/ICC 805 shall be an alternative for regulating the materials, design, construction and installation of systems for rainwater collection, storage, treatment and distribution of nonpotable water. The use and application of nonpotable water shall comply with laws, rules and ordinances applicable in the jurisdiction. * * * P-1301.10 System abandonment. If the owner of an on-site nonpotable water reuse system or rainwater collection and conveyance system elects to cease use of, or fails to properly maintain such system, the system shall be abandoned and shall comply with the following: 1. All system piping connecting to a utility-provided water system shall be removed or disabled. 2. The water distribution piping or water supply piping system shall be replaced with an approved potable water supply piping system. Where an existing potable pipe system is already in place, the fixtures shall be connected to the existing system. 3. The storage tank shall be secured from accidental access by sealing or locking tank inlets and access points, or filling with sand or equivalent. P-1301.11 Trenching requirements for nonpotable water piping. Nonpotable water collection and distribution piping and reclaimed water piping shall be separated from the building sewer and potable water piping underground by 5 feet (1524 mm) of undisturbed or compacted earth. Nonpotable water collection and distribution piping shall not be located in, under or above cesspools, septic tanks, septic tank drainage fields or seepage pits. Buried nonpotable water piping shall comply with the requirements of Section 306. Exceptions: 1. The required separation distance shall not apply where the bottom of the nonpotable water pipe within 5 feet (1524 mm) of the sewer is not less than 12 inches (305 mm) above the top of the highest point of the sewer and the pipe materials conform to Table 702.3. 2. The required separation distance shall not apply where the bottom of the potable water service distribution pipe within 5 feet (1524 mm) of the nonpotable water pipe is not less than 12 inches (305 mm) above the top of the highest point of the nonpotable water pipe and the pipe materials comply with the requirements of Table 605.4. 3. Nonpotable water pipe is permitted to be located in the same trench with a building sewer, provided that such sewer is constructed of materials that comply with the requirements of Table 702.2. 4. The required separation distance shall not apply where a nonpotable water pipe crosses a sewer pipe, provided that the pipe is sleeved to not less than 5 feet (1524 mm) horizontally from the sewer pipe centerline on both sides of such crossing, with pipe materials that comply with Table 702.2. 5. The required separation distance shall not apply where a potable water service distribution pipe crosses a nonpotable water pipe, provided that the potable water service distribution pipe is sleeved for a distance of not less than 5 feet (1524 mm) horizontally from the centerline of the nonpotable pipe on both sides of such crossing, with pipe materials that comply with Table 702.2. 6. Irrigation piping located outside of a building and downstream of the backflow preventer is not required to meet the trenching requirements where nonpotable water is used for outdoor applications. * * * SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS * * * P-1302.10 Water pressure-reducing valve or regulator. Where the water pressure supplied by the pumping system exceeds 80 psi (552 kPa) static, a pressure-reducing valve shall be installed to reduce the pressure in the nonpotable water distribution system piping or water supply piping to 80 psi (552 kPa) static or less. Pressure-reducing valves shall be specified and installed in accordance with Section 604.8. P-1302.11 Distribution or water supply pipe. Distribution or water supply piping utilized in on-site nonpotable water reuse systems shall comply with Sections 1302.11.1 through 1302.11.3. * * * P-1302.11.3 Marking. On-site nonpotable water distribution or water supply piping labeling and marking shall comply with Section 608.9. * * * SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS * * * P-1303.13 Water pressure-reducing valve or regulator. Where the water pressure supplied by the pumping system exceeds 80 psi (552 kPa) static, a pressure-reducing valve shall be installed to reduce the pressure in the rainwater distribution or water supply system piping to 80 psi (552 kPa) static or less. Pressure-reducing valves shall be specified and installed in accordance with Section 604.8. P-1303.14 Distribution or water supply pipe. Distribution piping or water supply piping utilized in rainwater collection and conveyance systems shall comply with Sections P-1303.14.1 through P-1303.14.3. P-1303.14.1 Materials, joints and connections. Distribution piping or water supply piping shall conform to the standards and requirements specified in Section 605 for nonpotable water. P-1303.14.2 Design. Distribution piping or water supply piping systems shall be designed and sized in accordance with Section 604 for the intended application. P-1303.14.3 Marking. Nonpotable rainwater distribution piping or water supply piping labeling and marking shall comply with Section 608.9. * * * SECTION 1304 RECLAIMED WATER SYSTEMS * * * P-1304.2 Water pressure-reducing valve or regulator. Where the reclaimed water pressure supplied to the building exceeds 80 psi (552 kPa) static, a pressure-reducing valve shall be installed to reduce the pressure in the reclaimed water distribution or water supply system piping to 80 psi (552 kPa) static or less. Pressure-reducing valves shall be specified and installed in accordance with Section 604.8. 1304.3 Reclaimed water systems. P-1304.3.1 Distribution or water supply pipe. Distribution piping or water supply piping shall comply with Sections P-1304.3.1.1 through P-1304.3.1.3. Exception: Irrigation piping located outside of the building and downstream of a backflow preventer. P-1304.3.1.1 Materials, joints and connections. Distribution piping or water supply piping conveying reclaimed water shall conform to standards and requirements specified in Section 605 for nonpotable water. P-1304.3.1.2 Design. Distribution piping or water supply piping systems shall be designed and sized in accordance with Section 604 for the intended application. P-1304.3.1.3 Labeling and marking. Nonpotable distribution piping or water supply piping labeling and marking shall comply with Section 608.9. * * * CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS [Delete the contents of this Chapter in its entirety.] Reserved. * * * APPENDIX E SIZING OF WATER PIPING SYSTEM The International Plumbing Code Appendix E is adopted to provide acceptable methods for the sizing of water service and water distribution piping by a designer. Notwithstanding the definitions set forth in Chapter 2 of this code, the following definitions apply to this Appendix. WATER DISTRIBUTION PIPE. The pipe from the curb stop or curb line to the structure or through the meter pit to the first point of use if there is no structure. WATER SERVICE PIPE. The pipe from the water main to the curb stop or curb line as regulated by Philadelphia Water Department Regulations. WATER SUPPLY PIPES. The pipes within a structure or premises which convey water from the water distribution pipe to the plumbing fixtures or other outlets. * * * SUBCODE "PC" (THE PHILADELPHIA PERFORMANCE CODE FOR BUILDINGS AND FACILITIES) Article PC-1.0 Adoption of the “2021 International Code Council (ICC) Performance Code for Buildings and Facilities”, pursuant to the Pennsylvania Uniform Construction Code Act (“Act”), with state amendments and local amendments that were in effect prior to enactment of the Act or approved pursuant to Section 503 of the Act. § PC-1.1 The “2021 International Performance Code for Buildings and Facilities”, as published by the International Code Council, is hereby adopted as the Philadelphia Performance Code for Buildings and Facilities of the City of Philadelphia and is incorporated as if fully set forth herein, subject to the amendments provided in this Subcode PC. Editor's note: The 2021 Performance Code for Buildings and Facilities can be found at: https://codes.iccsafe.org/content/ICCPC2021V1.0 § PC-1.1.1 The numbers of all local amendments shall be preceded with the prefix “PC-”. § PC-1.1.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. [History: Added, Bill No. 030773 (approved December 31, 2003); repealed and replaced, Bill No. 180176 (approved June 6, 2018). Section 7 of Bill No. 180176 provides: "The provisions of this Ordinance shall be effective October 1, 2018, and upon taking effect replace and supersede previously adopted Regulations of the Department of Licenses and Inspections related to Subcode B and Subcode M." Repealed and replaced, Bill No. 260392 (approved June 12, 2026).] CHAPTER 1 GENERAL ADMINISTRATIVE PROVISIONS [Delete the contents of Chapter 1 and replace as follows:] SECTION PC-101 GENERAL PC-101.1 Supplemental administrative provisions. Administrative provisions of the Philadelphia Administrative Code and the other subcodes of the Philadelphia Building Construction and Occupancy Code shall supplement the performance provisions for plan review, permit issuance, inspection, certificate of occupancy or compliance and enforcement. PC-101.2 Appendices. Appendices A, B, C, D and E of the 2021 ICC Performance Code for Buildings and Facilities are hereby adopted and incorporated as a part of this code. SUBCODE "PM" (THE PHILADELPHIA PROPERTY MAINTENANCE CODE) Editor's note: To view the historical version of Subcode "PM" (repealed as of July 1, 2015), please click here. § PM-1. The International Property Maintenance Code, with certain deletions and additions, as set forth in § PM-4, is hereby adopted as the Philadelphia Property Maintenance Code. § PM-2. All material in § PM-4 that is reprinted from the International Property Maintenance Code is proprietary to and copyrighted by, or licensed to, International Code Council, Inc., ALL RIGHTS RESERVED. For information on permission to copy International Code Council, Inc. material contained herein, please contact: Publications, 4051 West Flossmoor Road, Country Club Hills, IL 60478. Phone 1-888-ICC-SAFE (422-7233). § PM-3. Throughout § PM-4, references to "International" codes or "ICC" codes shall be deemed to refer to the "Philadelphia" codes of the same name. § PM-4. Text of the Philadelphia Property Maintenance Code: [History: Added, Bill No. 960587-A (approved March 26, 1997). This Subcode "PM" repealed and replaced in its entirety previous Title 4.2, which was based on 1981 Ordinances, p. 1258, as amended, and Title 7, which was based on 1954 Ordinances, p. 516, as amended. Amended, Bill No. 030774 (approved December 31, 2003). Subcode PM was repealed and replaced by Bill No. 120647 (approved January 20, 2014). Bill No. 120647 was effective July 1, 2015. See Bill No. 140894 (approved December 19, 2014). Subcode PM was further amended, and its substantive provisions replaced in their entirety, by Bill No. 140856 ( approved December 19, 2014), effective July 1, 2015. Section 11 of Bill No. 140856 provides: "This Ordinance shall take effect upon the effective date of Bill No. 120647 (approved January 20, 2014). This Ordinance shall supersede § PM-4 of the Philadelphia Property Maintenance Code as adopted by Bill No. 120647 (approved January 20, 2014), and shall supersede any other ordinance that amended § PM-4 of the Philadelphia Property Maintenance Code as adopted by Bill No. 120647."] [History: Amended, Bill No. 180746 (approved January 3, 2019).] CHAPTER 1 SCOPE AND ADMINISTRATION PART 1 – SCOPE AND APPLICATION SECTION PM-101 GENERAL PM-101.1 Title. These provisions shall be known as the Philadelphia Property Maintenance Code, hereinafter referred to as "this code". PM-101.2 Scope. The provisions of this code shall apply to all existing residential and nonresidential structures and all existing premises and constitute minimum requirements and standards for premises, structures, equipment and facilities for light, ventilation, space, heating, sanitation, protection from the elements, life safety, safety from fire and other hazards, and for safe and sanitary maintenance; the responsibility of owners, operators and occupants; the occupancy of existing structures and premises, and for administration, enforcement and penalties. PM-101.3 Intent. This code shall be construed to secure its expressed intent, which is to ensure public health, safety and welfare insofar as they are affected by the continued occupancy and maintenance of structures and premises. Existing structures and premises that do not comply with these provisions shall be altered or repaired to provide a minimum level of health and safety as required herein. SECTION PM-102 APPLICABILITY PM-102.1 [Reserved] PM-102.2 Maintenance. Equipment, systems, devices and safeguards required by this code or a previous regulation or code under which the structure or premises was constructed, altered or repaired shall be maintained in good working order. No owner, operator or occupant shall cause any service, facility, equipment or utility which is required under this Section to be removed from or shut off from or discontinued for any occupied dwelling, except for such temporary interruption as necessary while repairs or alterations are in progress. The requirements of this code are not intended to provide the basis for removal or abrogation of fire protection and safety systems and devices in existing structures. Except as otherwise specified herein, the owner or the owner's designated agent shall be responsible for the maintenance of buildings, structures and premises. PM-102.3 Application of other codes. Repairs, additions or alterations to a structure, or changes of occupancy, shall be done in accordance with the procedures and provisions of the International Building Code, International Fuel Gas Code, International Mechanical Code and NFPA 70. Nothing in this code shall be construed to cancel, modify or set aside any provision of the International Zoning Code. PM-102.4 Existing remedies. The provisions in this code shall not be construed to abolish or impair existing remedies of the jurisdiction or its officers or agencies relating to the removal or demolition of any structure which is dangerous, unsafe and insanitary. PM-102.5 [Reserved] PM-102.6 Historic buildings. The provisions of this code shall not be mandatory for existing buildings or structures designated as historic buildings when such buildings or structures are judged by the code official to be safe and in the public interest of health, safety and welfare. Nothing in this code shall be construed to repeal or modify any applicable provisions of Chapter 14-1000 ("Historic Preservation"). PM-102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 10 and considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Exception: Where enforcement of a code provision would violate the conditions of the equipment or appliance, the conditions of the listing shall apply. PM-102.8 Requirements not covered by code. Requirements necessary for the strength, stability or proper operation of an existing fixture, structure or equipment, or for the public safety, health and general welfare, not specifically covered by this code, shall be determined by the code official. PM-102.9 Application of references. References to Chapter or Section numbers, or to provisions not specifically identified by number, shall be construed to refer to such Chapter, Section or provision of this code. PART 2 – ADMINISTRATION AND ENFORCEMENT SECTION PM-103 [Reserved] SECTION PM-104 [Reserved] SECTION PM-105 [Reserved] SECTION PM-106 [Reserved] SECTION PM-107 [Reserved] SECTION PM-108 UNSAFE STRUCTURES AND EQUIPMENT PM-108.1 General. When a structure, equipment, or shared retaining wall is found by the code official to be unsafe, or when a structure is found unfit for human occupancy, or is found unlawful, such structure shall be condemned pursuant to the provisions of this code. PM-108.1.1 Unsafe structures. An unsafe structure is a structure, other than a shared retaining wall subject to the provisions of PM-108.1.3, that is found to be dangerous to the life, health, property or safety of the public or the occupants of the structure by not providing minimum safeguards to protect or warn occupants in the event of fire, or because such structure contains unsafe equipment or is so damaged, decayed, dilapidated, structurally unsafe or of such faulty construction or unstable foundation, that partial or complete collapse is possible. PM-108.1.2 Unsafe equipment. Unsafe equipment includes any boiler, heating equipment, elevator, moving stairway, electrical wiring or device, flammable liquid containers or other equipment on the premises or within the structure which is in such disrepair or condition that such equipment is a hazard to life, health, property or safety of the public or occupants of the premises or structure. PM-108.1.3 PM-108.1.3 Unsafe shared retaining walls. An unsafe shared retaining wall is one that: (a) has two or more separate owners that, as determined by the Department of Streets are responsible parties for a retaining wall; and (b) is found to be dangerous to the life, health, property or safety of the public or the occupants of the property because the wall is damaged, decayed, dilapidated, structurally unsafe or of such faulty construction or unstable foundation that partial or complete collapse is possible. PM-108.1.4 Unlawful structure. An unlawful structure is one found in whole or in part to be occupied by more persons than permitted under this code, or was erected, altered or occupied contrary to law. PM-108.1.5 Dangerous structure or premises. For the purpose of this code, any structure or premises that has any or all of the conditions or defects described below shall be considered dangerous: 1. Any door, aisle, passageway, stairway, exit or other means of egress that does not conform to the approved building or fire code of the jurisdiction as related to the requirements for existing buildings. 2. The walking surface of any aisle, passageway, stairway, exit or other means of egress is so warped, worn loose, torn or otherwise unsafe as to not provide safe and adequate means of egress. 3. Any portion of a building, structure or appurtenance that has been damaged by fire, earthquake, wind, flood, deterioration, neglect, abandonment, vandalism or by any other cause to such an extent that it is likely to partially or completely collapse, or to become detached or dislodged. 4. Any portion of a building, or any member, appurtenance or ornamentation on the exterior thereof that is not of sufficient strength or stability, or is not so anchored, attached or fastened in place so as to be capable of resisting natural or artificial loads of one and one-half the original designed value. 5. The building or structure, or part of the building or structure, because of dilapidation, deterioration, decay, faulty construction, the removal or movement of some portion of the ground necessary for the support, or for any other reason, is likely to partially or completely collapse, or some portion of the foundation or underpinning of the building or structure is likely to fail or give way. 6. The building or structure, or any portion thereof, is clearly unsafe for its use and occupancy. 7. The building or structure is neglected, damaged, dilapidated, unsecured or abandoned so as to become an attractive nuisance to children who might play in the building or structure to their danger, becomes a harbor for vagrants, criminals or immoral persons, or enables persons to resort to the building or structure for committing a nuisance or an unlawful act. 8. Any building or structure has been constructed, exists or is maintained in violation of any specific requirement or prohibition applicable to such building or structure provided by the approved building or fire code of the jurisdiction, or of any law or ordinance to such an extent as to present either a substantial risk of fire, building collapse or any other threat to life and safety. 9. A building or structure, used or intended to be used for dwelling purposes, because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangement, inadequate light, ventilation, mechanical or plumbing system, or otherwise, is determined by the code official to be unsanitary, unfit for human habitation or in such a condition that is likely to cause sickness or disease. 10. Any building or structure, because of a lack of sufficient or proper fire-resistance-rated construction, fire protection systems, electrical system, fuel connections, mechanical system, plumbing system or other cause, is determined by the code official to be a threat to life or health. 11. Any portion of a building remains on a site after the demolition or destruction of the building or structure or whenever any building or structure is abandoned so as to constitute such building or portion thereof as an attractive nuisance or hazard to the public. PM-108.2 Sealing of vacant structures. If the structure is open to trespass or unfit for human habitation and occupancy, and is not in danger of structural collapse, the code official is authorized to post a No Trespassing placard on the premises and order the structure closed up so as not to be open to trespass. Upon failure of the owner to seal the premises within the time specified in the order, the code official shall cause the premises to be sealed and secured through any available public agency or by contract or arrangement by private persons and the cost thereof shall be charged against the real estate upon which the structure is located and shall be a lien upon such real estate and may be collected by any other legal resource. PM-108.2.1 Authority to disconnect service utilities. The code official shall have the authority to authorize disconnection of utility service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section PM-102.7 in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without approval. The code official shall notify the serving utility and, whenever possible, the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnection the owner or occupant of the building structure or service system shall be notified in writing as soon as practical thereafter. [History: Amended, Bill No. 230647 (approved December 13, 2023).] [History: Amended, Bill No. 230647 (approved December 13, 2023).] [History: Amended, Bill No. 230647 (approved December 13, 2023).] SECTION PM-109 UNFIT STRUCTURES PM-109.1 Unfit dwellings: A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe, unlawful or, because of the degree to which the structure is in disrepair or lacks maintenance, is insanitary, vermin or rat infested, contains filth and contamination, or lacks ventilation, illumination, sanitary or heating facilities or other essential equipment required by this code, or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. PM-109.1.1 Continued occupancy: Where a dwelling is designated as unfit for human habitation but does not present an immediate hazard to safety, evacuation will not be required; however, the owner shall be denied the right to collect rent for the duration of such unfit designation. PM-109.1.2 New tenancy: Where a dwelling is designated as unfit for human habitation, the owner shall be prohibited from admitting any new tenants to any tenant space within such dwelling for the duration of such unfit designation. SECTION PM-110 IMMINENTLY DANGEROUS STRUCTURES PM-110.1 Conditions: When, in the opinion of the code official, there is imminent danger of failure or collapse of a structure or any part thereof which endangers life, or when any structure or part of a structure has fallen and life is endangered by the occupation of the structure, the code official is hereby authorized and empowered to order and require the occupants to vacate the same forthwith in accordance with the cease operations provisions set forth in the administrative code. The code official shall cause to be posted at each entrance to such structure a notice stating the imminent danger and prohibiting occupancy. It shall be unlawful for any person to enter such structure except for the purpose of making the required repairs or demolishing the structure. PM-110.1.1 Imminently dangerous shared retaining wall: Consistent with Section A-601.3(14), imminently dangerous shared retaining walls shall be subject to the Basic Fines set forth in subsection A-601.1 of The Philadelphia Code and shall not be subject to additional heightened fines. An imminently dangerous shared retaining wall is one that: (a) has two or more separate owners that, as determined by the Department of Streets, are responsible parties for a retaining wall; and (b) is, in the opinion of the code official, in imminent danger of failure or collapse. PM-110.2 Notice: If an imminently dangerous condition is found, the code official shall serve on the owner, managing agent or person in control of the structure a written notice describing the imminent danger and specifying the required repair to render the structure safe, or requiring the imminently dangerous structure or portion thereof to be demolished within a stipulated time. Such notice shall require the person thus notified to declare immediately to the code official acceptance or rejection of the terms of an order to demolish. PM-110.2.1 Immediate hazard: Where the code official determines that a condition exists which creates a hazard to life or property requiring immediate action, an immediate oral order shall have the full effect of the subsequent written order. PM-110.3 Posting notice: Regardless of whether the person addressed with a notice of imminent danger receives service by one or more of the methods specified in the administrative code, a copy of the notice shall be posted in a conspicuous place on the premises; and such procedure shall be deemed the equivalent of personal notice. PM-110.4 Disregard of notice: Where the order to eliminate an imminent danger is rejected or not obeyed, or when, in the opinion of the code official, immediate action is required to protect the public safety, the code official shall cause the necessary work to be done to demolish the structure or to render the structure temporarily safe. Nothing in this code shall be deemed to limit in any way the right, under any existing law or ordinance, of any department of the City to correct or remove any condition deemed to be an immediate hazard to the health or safety of the public. When the code official proceeds to demolish any structure whether by contract or by its own employees, the contract or the code official may provide for the installation of a fence or other protective device and the application of environmentally-safe treatments to control vegetative overgrowth by the demolition contractor or by the code official in order to secure the perimeter of the vacant lot, protect the health, safety and welfare of the community, prevent vegetative overgrowth and deter the illegal dumping of trash and debris. In addition, the code official shall work cooperatively with other city and city-related agencies on any plans for the acquisition, disposition and re-use of vacant lots including, but not limited to: community development, housing, neighborhood gardening, landscaping, play areas, side yards, or any other legal uses. The code official shall have the discretion to determine whether a fence is necessary based on a planned re-use of the vacant lot by an abutting or nearby property owner, community development corporation, community-based or block organization; other unique circumstances; or upon the written request of a City department, agency or official. PM-110.5 Closing streets: When necessary for the public safety, the code official shall order the temporary closing of structures, sidewalks, streets, public ways and places adjacent to dangerous structures, and prohibit the same from being used. PM-110.6 Costs of emergency repairs: Where the code official incurs costs of emergency repairs whether by itself or by contract, such costs shall be charged to the owner. The code official shall, with the approval of the Law Department, collect such costs from the owner by lien or otherwise. PM-110.7 Removal of imminently dangerous classification: When the owner chooses to bring an imminently dangerous structure into compliance by other than demolition, the code official is authorized to require that an analysis and plan of compliance prepared by a structural engineer registered in the Commonwealth of Pennsylvania be submitted for review and approval. PM-110.7.1 Work schedules: As part of the application process to secure a building permit to abate an imminently dangerous condition, the applicant shall provide a schedule to the code official. The code official shall have the authority to accept or reject the work schedule. The work schedule shall contain: 1. The date work will commence to abate the condition. 2. The name, address and phone number of the contractor who will abate the dangerous condition. 3. Incremental phases which include work to be performed and time estimates for completion within each phase. 4. The date all work for bringing the property into code compliance is to be completed. PM-110.7.1.1 Failure to maintain work schedule: If the work does not conform to the approved work schedule, the permit shall be revoked. [History: Added, Bill No. 230647 (approved December 13, 2023).] CHAPTER 2 DEFINITIONS SECTION PM-201 GENERAL PM-201.1 Scope. Unless otherwise expressly stated, the following terms shall, for the purposes of this code, have the meanings shown in this Chapter. PM-201.2 Interchangeability. Words stated in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular. PM-201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the International Building Code, International Fire Code, International Zoning Code, International Plumbing Code, International Mechanical Code or NFPA 70, such terms shall have the meanings ascribed to them as stated in those codes. PM-201.4 Terms not defined. Where terms are not defined through the methods authorized by this Section, such terms shall have ordinarily accepted meanings such as the context implies. PM-201.5 Parts. Whenever the words "dwelling unit", "dwelling", "premises", "building", "rooming house", "rooming unit", "housekeeping unit" or "story" are stated in this code, they shall be construed as though they were followed by the words "or any part thereof". SECTION PM-202 GENERAL DEFINITIONS ANCHORED. Secured in a manner that provides positive connection. APPROVED. Approved by the code official. BASEMENT. That portion of a building which is partly or completely below grade. BATHROOM. A room containing plumbing fixtures including a bathtub or shower. BED BUGS. Insects of the species Cimex Lectularius, and related species. BEDROOM. Any room or space used or intended to be used for sleeping purposes in either a dwelling or sleeping unit BLIGHTING PROBLEM. A building that lacks windows with frames and glazing and/or lacks one or more doors in entryways of the building if: 1. the building is located on a block face where eighty percent (80%) or more buildings on the block face are occupied; or 2. the code official has provided 30 days' notice to the owner of the property that the code official has determined, in consultation with other City officials as appropriate, that the lack of windows and/or entry doors has a significant adverse influence on the community based on the following factors: a. deterioration and/or safety of the property; b. safety of the surrounding community; c. the value of intact, occupied properties in the surrounding vicinity of the property; d. marketability of the property; and e. community morale. CODE OFFICIAL. The Commissioner of Licenses and Inspection, or any duly authorized representative. DETACHED. When a structural element is physically disconnected from another and that connection is necessary to provide a positive connection. DETERIORATION. To weaken, disintegrate, corrode, rust or decay and lose effectiveness. DRINKING FOUNTAIN. A functioning plumbing fixture that is connected to the potable water distribution system and the drainage system. The fixture allows the user to obtain a drink directly from a stream of flowing water without the use of any accessories. Drinking fountains include hybrid fixtures with both bottle filling and direct drinking capabilities. [B] DWELLING UNIT. A single unit providing complete, independent living facilities for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation. EASEMENT. That portion of land or property reserved for present or future use by a person or agency other than the legal fee owner(s) of the property. The easement shall be permitted to be for use under, on or above a said lot or lots. EQUIPMENT SUPPORT. Those structural members or assemblies of members or manufactured elements, including braces, frames, lugs, snuggers, hangers or saddles, that transmit gravity load, lateral load and operating load between the equipment and the structure. EXTERIOR PROPERTY. The open space on the premises and on adjoining property under the control of owners or operators of such premises. FAMILY. An individual or two or more persons related by blood, marriage, Life Partnership or adoption; or a group of three or less unrelated persons, living together as a single housekeeping unit. FORECLOSED VACANT RESIDENTIAL PROPERTY or FVRP. A vacant residential property that is in default on a mortgage, has had a lis pendens filed against it by the lender holding a mortgage on the property, is subject to an ongoing foreclosure action by the lender, or has been transferred to the lender under a deed in lieu of foreclosure, regardless of any subsequent conveyance of title or interest in the property. Such a residential property shall no longer be considered an FVRP when a natural person takes lawful possession of such property for use as his or her residence. GARBAGE. The animal or vegetable waste resulting from the handling, preparation, cooking and consumption of food. GIFT PROPERTY PROGRAM. The program operated by the Vacant Property Review Committee under Chapter 16-400 of The Philadelphia Code. GUARD. A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to a lower level. HABITABLE SPACE. Space in a structure for living, sleeping, eating or cooking. Bathrooms, toilet rooms, closets, halls, storage or utility spaces, and similar areas are not considered habitable spaces. HOUSEKEEPING UNIT. A room or group of rooms forming a single habitable space equipped and intended to be used for living, sleeping, cooking and eating which does not contain, within such a unit, a toilet, lavatory and bathtub or shower. IMMINENT DANGER. A condition which could cause serious or life-threatening injury or death at any time. INFESTATION. The presence, within or contiguous to, a structure or premises of insects, rats, vermin or other pests. INOPERABLE MOTOR VEHICLE. A vehicle which cannot be driven upon the public streets for reason including but not limited to being unlicensed, wrecked, abandoned, in a state of disrepair, or incapable of being moved under its own power. LABELED. Equipment, materials or products to which have been affixed a label, seal, symbol or other identifying mark of a nationally recognized testing laboratory, inspection agency or other organization concerned with product evaluation that maintains periodic inspection of the production of the above-labeled items and whose labeling indicates either that the equipment, material or product meets identified standards or has been tested and found suitable for a specified purpose. LET FOR OCCUPANCY OR LET. To permit, provide or offer possession or occupancy of a dwelling, dwelling unit, rooming unit, building, premise or structure by a person who is or is not the legal owner of record thereof, pursuant to a written or unwritten lease, agreement or license, or pursuant to a recorded or unrecorded agreement of contract for the sale of land. LARGE VACANT COMMERCIAL OR INDUSTRIAL PROPERTY or LVCIP. Any vacant property containing an improvement that has a commercial or industrial zoning designation, where the improvement area is greater than 5,000 square feet. MANAGING AGENT. A natural person over the age of eighteen years who either resides within the City or customarily and regularly attends a business office maintained within the City and who agrees to receive service of notices, orders, or summonses issued by the Department on behalf of the owner or corporate principal. An owner or corporate principal who meets the above qualifications may serve as a managing agent. NEGLECT. The lack of proper maintenance for a building or structure. OCCUPANCY. The purpose for which a building or portion thereof is utilized or occupied. OCCUPANT. Any individual living or sleeping in a building, or having possession of a space within a building. OPENABLE AREA. That part of a window, skylight or door which is available for unobstructed ventilation and which opens directly to the outdoors. OPERATOR. Any person who has charge, care or control of a structure or premises which is let or offered for occupancy. OWNER. Any person, agent, operator, firm or corporation having a legal or equitable interest in the property; or recorded in the official records of the state, county or municipality as holding title to the property; or otherwise having control of the property, including the guardian of the estate of any such person, and the executor or administrator of the estate of such person if ordered to take possession of real property by a court. As to FVRPs, this term shall also apply to lenders, mortgage servicers, and any person, legal entity or agent responsible for the maintenance, preservation, or operation of the property. PERSON. An individual, corporation, partnership or any other group acting as a unit. PEST ELIMINATION. The control and elimination of insects, rodents or other pests by eliminating their harborage places; by removing or making inaccessible materials that serve as their food or water; by other approved pest elimination methods. PREMISES. A lot, plot or parcel of land, easement or public way, including any structures thereon. PUBLIC WAY. Any street, alley or similar parcel of land essentially unobstructed from the ground to the sky, which is deeded, dedicated or otherwise permanently appropriated to the public for public use. ROOMING HOUSE. A building arranged or occupied for lodging, with or without meals, for compensation and not occupied as a one- or two-family dwelling. ROOMING UNIT. Any room or group of rooms forming a single habitable unit occupied or intended to be occupied for sleeping or living, but not for cooking purposes. RUBBISH. Combustible and noncombustible waste materials, except garbage; the term shall include the residue from the burning of wood, coal, coke and other combustible materials, paper, rags, cartons, boxes, wood, excelsior, rubber, leather, tree branches, yard trimmings, tin cans, metals, mineral matter, glass, crockery and dust and other similar materials. [B] SLEEPING UNIT. A room or space in which people sleep, which can also include permanent provisions for living, eating and either sanitation or kitchen facilities, but not both. Such rooms and spaces that are also part of a dwelling unit are not sleeping units. STRICT LIABILITY OFFENSE. An offense in which the prosecution in a legal proceeding is not required to prove criminal intent as a part of its case. It is enough to prove that the defendant either did an act which was prohibited, or failed to do an act which the defendant was legally required to do. STRUCTURE. That which is built or constructed or a portion thereof. TENANT. A person, corporation, partnership or group, whether or not the legal owner of record, occupying a building or portion thereof as a unit. TOILET ROOM. A room containing a water closet or urinal but not a bathtub or shower. ULTIMATE DEFORMATION. The deformation at which failure occurs and which shall be deemed to occur if the sustainable load reduces to eighty percent (80%) or less of the maximum strength. VENTILATION. The natural or mechanical process of supplying conditioned or unconditioned air to, or removing such air from, any space. WATER DISPENSER. A functioning plumbing fixture that is manually controlled by the user for the purpose of dispensing potable drinking water into a receptacle such as a cup, glass or bottle. Such fixture is connected to the potable water distribution system of the premises. This definition also includes a free-standing apparatus for the same purpose that is not connected to the potable water distribution system and that is supplied with potable water from a container, bottle or reservoir. WORKMANLIKE. Executed in a skilled manner; e.g., generally plumb, level, square, in line, undamaged and without marring adjacent work. YARD. An open space on the same lot with a structure. [History: Added, Bill No. 190106-A (approved December 30, 2019), effective January 1, 2021.] [History: Added, Bill No. 160472 (approved June 28, 2016), effective September 26, 2016; amended, Bill No. 220221-A (approved August 31, 2022) .] [History: Amended, Bill No. 150719 (approved December 23, 2015).] [History: Amended, Bill No. 150719 (approved December 23, 2015).] [History: Added, Bill No. 160472 (approved June 28, 2016), effective September 26, 2016.] CHAPTER 3 GENERAL REQUIREMENTS SECTION PM-301 GENERAL PM-301.1 Scope. The provisions of this Chapter shall govern the minimum conditions and the responsibilities of persons for maintenance of structures, equipment and exterior property. PM-301.2 Responsibility. The owner of the premises shall maintain the structures and exterior property in compliance with these requirements, except as otherwise provided for in this code. A person shall not occupy as owner-occupant or permit another person to occupy premises which are not in a sanitary and safe condition and which do not comply with the requirements of this Chapter. Occupants of a dwelling unit, rooming unit or housekeeping unit are responsible for keeping in a clean, sanitary and safe condition that part of the dwelling unit, rooming unit, housekeeping unit or premises which they occupy and control. PM-301.3 Vacant structures and land. All vacant structures and premises thereof or vacant land shall be maintained in a clean, safe, secure and sanitary condition as provided herein so as not to cause a blighting problem or adversely affect the public health or safety. SECTION PM-302 EXTERIOR PROPERTY AREAS PM-302.1 Sanitation. All exterior property and premises shall be maintained in a clean, safe and sanitary condition. The occupant shall keep that part of the exterior property which such occupant occupies or controls in a clean and sanitary condition. PM-302.2 Grading and drainage. All premises shall be graded and maintained to prevent the erosion of soil and to prevent the accumulation of standing water thereon, or within any structure located thereon. Exception: Approved retention areas and reservoirs. PM-302.3 Sidewalks and driveways. All sidewalks, walkways, stairs, driveways, parking spaces and similar areas shall be kept in a proper state of repair, and maintained free from hazardous conditions. PM-302.4 Weeds. All premises and exterior property shall be maintained free from weeds or plant growth in excess of 10 inches. All noxious weeds shall be prohibited. Weeds shall be defined as all grasses, annual plants and vegetation, other than trees or shrubs provided; however, this term shall not include cultivated flowers and gardens. Upon failure of the owner or agent having charge of a property to cut and destroy weeds after service of a notice of violation, they shall be subject to prosecution in accordance with Subcode "A" (The Philadelphia Administrative Code) and as prescribed by the authority having jurisdiction. Upon failure to comply with the notice of violation, any duly authorized employee of the jurisdiction or contractor hired by the jurisdiction shall be authorized to enter upon the property in violation and cut and destroy the weeds growing thereon, and the costs of such removal shall be paid by the owner or agent responsible for the property. PM-302.5 Rodent harborage. All structures and exterior property shall be kept free from rodent harborage and infestation. Where rodents are found, they shall be promptly exterminated by approved processes which will not be injurious to human health. After extermination, proper precautions shall be taken to eliminate rodent harborage and prevent reinfestation. PM-302.6 Exhaust vents. Pipes, ducts, conductors, fans or blowers shall not discharge gases, steam, vapor, hot air, grease, smoke, odors or other gaseous or particulate wastes directly upon abutting or adjacent public or private property or that of another tenant. PM-302.7 Accessory structures. All accessory structures, including detached garages, fences and walls, shall be maintained structurally sound and in good repair. PM-302.7.1 Temporary Fences: No person shall place or maintain a fence in the 10th Councilmanic District that is free-standing (meaning not permanently affixed to the property) and that is of a type customarily used for building projects and construction sites, such as a modular chain-link fence, unless such free-standing fence is placed and maintained in connection with a building permit issued pursuant to Subcode "A" (The Philadelphia Administrative Code), or unless such fence is placed and maintained to protect against either a potential safety hazard from an ongoing work process for which a building permit is not required or any imminent safety hazard. Any temporary fence so placed shall be removed upon completion of the work authorized by such building permit or the elimination of the present or potential safety hazard. PM-302.8 Motor vehicles. Except as provided for in other regulations, no inoperative or unlicensed motor vehicle shall be parked, kept or stored on any premises, and no vehicle shall at any time be in a state of major disassembly, disrepair, or in the process of being stripped or dismantled. Painting of vehicles is prohibited unless conducted inside an approved spray booth. Exception: A vehicle of any type is permitted to undergo major overhaul, including body work, provided that such work is performed inside a structure or similarly enclosed area designed and approved for such purposes. PM-302.9 Defacement of property. No person shall willfully or wantonly damage, mutilate or deface any exterior surface of any structure or building on any private or public property by placing thereon any marking, carving or graffiti. It shall be the responsibility of the owner to restore said surface to an approved state of maintenance and repair. PM-302.10 Encroaching Trees. No person shall allow any tree on his or her property to overhang or rest on the property of another person if the tree (i) is dead, weakened or decayed such that a significant portion of the tree could reasonably be expected to fall or come to rest on the property of another person or (ii) otherwise encroaches in a manner that harms or is likely to harm the other’s property. CLIP may serve notice of violation with sixty (60) days to cure the violation. Upon failure of the tree owner to abate the encroachment after service of a notice of violation, CLIP shall be authorized, itself or by contract, to prune or remove the encroaching tree to the extent necessary to cure the violation and the owner of the tree shall be liable for the costs of such work. This provision shall not apply to any Street Tree consistent with the provisions of Section 15-203 of The Philadelphia Code. [History: Added, Bill No. 240371 (approved June 26, 2024).] SECTION PM-303 SWIMMING POOLS, SPAS AND HOT TUBS PM-303.1 Swimming pools. Swimming pools shall be maintained in a clean and sanitary condition, and in good repair. PM-303.2 Enclosures. pools, hot tubs and spas, containing water more than 24 inches (610 mm) in depth shall be completely surrounded by a fence or barrier at least 48 inches (1219 mm) in height above the finished ground level measured on the side of the barrier away from the pool. Gates and doors in such barriers shall be self-closing and self-latching. Where the self-latching device is less than 54 inches (1372 mm) above the bottom of the gate, the release mechanism shall be located on the pool side of the gate. Self-closing and self-latching gates shall be maintained such that the gate will positively close and latch when released from an open position of 6 inches (152 mm) from the gatepost. No existing pool enclosure shall be removed, replaced or changed in a manner that reduces its effectiveness as a safety barrier. Exception: Spas or hot tubs with a safety cover that complies with ASTM F 1346 shall be exempt from the provisions of this Section. SECTION PM-304 EXTERIOR STRUCTURE PM-304.1 General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare. PM-304.1.1 Unsafe conditions. The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the International Building Code or the International Existing Building Code as required for existing building: 1. The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength; 2. The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects; 3. Structures or components thereof that have reached their limit state; 4. Siding and masonry joints including joints between the building envelope and the perimeter of windows, doors and skylights are not maintained, weather resistant or water tight; 5. Structural members that have evidence of deterioration or that are not capable of safely supporting all nominal loads and load effects; 6. Foundation systems that are not firmly supported by footings, are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects; 7. Exterior walls that are not anchored to supporting and supported elements or are not plumb and free of holes, cracks or breaks and loose or rotting materials, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects; 8. Roofing or roofing components that have defects that admit rain, roof surfaces with inadequate drainage, or any portion of the roof framing that is not in good repair with signs of deterioration, fatigue or without proper anchorage and incapable of supporting all nominal loads and resisting all load effects; 9. Flooring and flooring components with defects that affect serviceability or flooring components that show signs of deterioration or fatigue, are not properly anchored or are incapable of supporting all nominal loads and resisting all load effects; 10. Veneer, cornices, belt courses, corbels, trim, wall facings and similar decorative features not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; 11. Overhang extensions or projections including, but not limited to, trash chutes, canopies, marquees, signs, awnings, fire escapes, standpipes and exhaust ducts not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; 12. Exterior stairs, decks, porches, balconies and all similar appurtenances attached thereto, including guard s and handrails, are not structurally sound, not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; or 13. Chimneys, cooling towers, smokestacks and similar appurtenances not structurally sound or not properly anchored, or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects. Exceptions: 1. When substantiated otherwise by an approved method. 2. Demolition of unsafe conditions shall be permitted when approved by the code official. PM-304.2 Protective treatment. All exterior surfaces, including but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences, shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. All siding and masonry joints, as well as those between the building envelope and the perimeter of windows, doors and skylights, shall be maintained weather resistant and water tight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. [F] PM-304.3 Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). PM-304.4 Structural members. All structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads. PM-304.5 Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. PM-304.6 Exterior walls. All exterior walls shall be free from holes, breaks, and loose or rotting materials; and maintained weatherproof and properly surface coated where required to prevent deterioration. PM-304.6.1 Satellite Dishes and Antennas; Findings. 1. The City of Philadelphia was established by Charter of 1701, is considered the birthplace of American Independence, the American Revolution and a centerpiece of early American history. 2. Philadelphia boasts historical, cultural and architectural lineage longer than that of almost any other place in America, with much of its buildings dating from the early 20th Century or earlier. 3. Certain considerations should be made to preserve the character and appeal of this uniquely American city as modern technological advancements are integrated into the City's landscape. 4. The City of Philadelphia has a vested interest in protecting its neighborhoods from conditions that could substantially and interfere with enhancing quality of life, fostering and facilitating commerce, maintaining and improving property values, and preserving and protecting the public's health, safety, and welfare. 5. The City of Philadelphia has an interest in ensuring the structural integrity and safety of building appurtenants, particularly those that extend into the public right-of-way. 6. The City of Philadelphia also recognizes the interest of its citizens in receiving and maintaining access to television, cable and satellite airwaves. 7. The Federal Communications Commission in 1996 adopted the Over-the-Air Reception Devices ("OTARD") rule concerning governmental and nongovernmental restrictions on viewers' ability to receive video programming signals. 8. Since then, the OTARD ruling has been interpreted by the FCC to allow the imposition of "reasonable" regulations on satellite dish and antenna placement under terms and conditions that don't impede signal access. 9. Particular attention needs to be given to tailoring measures that properly balance the interest of cable and satellite signal access and the City's interest in quality of life enhancement, historic preservation and public safety. PM-304.6.2 Satellite Dishes and Antennas; Locations. PM-304.6.2.1 Where an alternative location is available, including but not limited to a roof, rear yard or facade, or side yard or facade, no property owner or tenant in a multiple-family or two-family dwelling shall place or permit the placement of a satellite dish or antenna between the facade of the building and the street, unless the device is wholly within a balcony or patio area that is under the exclusive use or control of the unit owner or tenant. PM-304.6.2.2 Where an alternative location is available for placement of a satellite dish or antenna, with no material delay or material reduction in signal reception and at no significant additional cost to the owner or tenant (including but not limited to a roof, rear yard or facade, or side yard or facade), no property owner or tenant in a one-family dwelling shall place, install or maintain, or allow to be placed, installed or maintained, a satellite dish or antenna between the facade of a building and the street. PM-304.6.2.3 Any property owner or tenant in a one-family, two-family or multi-family dwelling, if his or her satellite dish or antenna was installed by a provider or installer, shall keep the certification provided by the installer as required by Section 9-632(4) of this Code at the residence at which the satellite dish or antenna is maintained, and shall produce it upon request by an inspector from the Department. PM-304.6.2.4. No property owner or tenant shall place a satellite dish or antenna that does not meet one of the following criteria between the facade of any building and the street: 1. A "dish" antenna that is one meter or less in diameter and is designed to receive direct broadcast satellite service, including direct-to-home satellite service, or to receive or transmit fixed wireless signals via satellite. 2. An antenna that is one meter or less in diameter or diagonal measurement and is designed to receive video programming services via broadband radio service (wireless cable) or to receive or transmit fixed wireless signals other than via satellite. 3. An antenna that is designed to receive local television broadcast signals. PM-304.7 Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a nuisance. PM-304.8 Decorative features. All cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition. PM-304.9 Overhang extensions. All overhang extensions including, but not limited to canopies, marquees, signs, metal awnings, fire escapes, standpipes and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. PM-304.10 Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads. PM-304.11 Chimneys and towers. All chimneys, cooling towers, smoke stacks, and similar appurtenances shall be maintained structurally safe and sound, and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. PM-304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. PM-304.13 Window, skylight and door frames. Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight. PM-304.13.1 Glazing. All glazing materials shall be maintained free from cracks and holes. PM-304.13.2 Openable windows. Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware. PM-304.14 [Reserved] PM-304.15 Doors. All exterior doors, door assemblies and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section PM-702.3. PM-304.16 Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water. PM-304.17 Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents. PM-304.18 Building security. Doors, windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupant s and property within. PM-304.18.1 Doors. Doors providing access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a deadbolt lock designed to be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort and shall have a lock throw of not less than 1 inch (25 mm). Such deadbolt locks shall be installed according to the manufacturer's specifications and maintained in good working order. For the purpose of this Section, a sliding bolt shall not be considered an acceptable deadbolt lock. PM-304.18.2 Windows. Operable windows located in whole or in part within 6 feet (1828 mm) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. PM-304.18.3 Basement hatchways. Basement hatchways that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with devices that secure the units from unauthorized entry. PM-304.19 Additional Requirements for Doors, Windows and Other Openings. The owner of a structure, including a vacant structure, shall keep all doors, windows and openings from the roof or other areas in good repair, and shall ensure that such doors, windows and openings are securely locked, fastened or otherwise secured. Sealing such a property with boards or masonry or other materials that are not windows with frames and glazing or entry doors shall not constitute good repair or being locked, fastened or otherwise secured. PM-304.19.1 Use of alternative materials. If securely fastened windows and doors fail or are inadequate to prevent trespassers from entering a building, the owner shall take any measures prescribed by the code official to prevent unauthorized entry to the premises by closing all openings with materials approved by the code official, such as closing and securing all accessible openings using a commercial-quality, 14 gauge, rust-proof steel security panel or door, or such other materials deemed by the code official to provide an equivalent level of protection considering the specific characteristics of a property and its location. Security panels and doors shall be secured from the building interior, allow emergency access such as by key, and have an exterior finish that allows for easy removal of graffiti. The owner of property who shall obtain approval from the code official to use alternative materials. The code official shall promulgate regulations outlining the process by which an owner may obtain approval to use alternative materials. SECTION PM-305 INTERIOR STRUCTURE PM-305.1 General. The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. Occupants shall keep that part of the structure which they occupy or control in a clean and sanitary condition. Every owner of a structure containing a rooming house, housekeeping units, a hotel, a dormitory, two or more dwelling units or two or more nonresidential occupancies, shall maintain, in a clean and sanitary condition, the shared or public areas of the structure and exterior property. PM-305.1.1 Unsafe conditions. The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the International Building Code or the International Existing Building Code as required for existing buildings: 1. The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength; 2. The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects; 3. Structures or components thereof that have reached their limit state; 4. Structural members are incapable of supporting nominal loads and load effects; 5. Stairs, landings, balconies and all similar walking surfaces, including guards and handrails, are not structurally sound, not properly anchored or are anchored with connections not capable of supporting all nominal loads and resisting all load effects; 6. Foundation systems that are not firmly supported by footings are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects. Exceptions: 1. When substantiated otherwise by an approved method. 2. Demolition of unsafe conditions shall be permitted when approved by the code official. PM-305.2 Structural members. All structural members shall be maintained structurally sound, and be capable of supporting the imposed loads. PM-305.3 Interior surfaces. All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. PM-305.4 Stairs and walking surfaces. Every stair, ramp, landing, balcony, porch, deck or other walking surface shall be maintained in sound condition and good repair. PM-305.5 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. PM-305.6 Interior doors. Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware. SECTION PM-306 COMPONENT SERVICEABILITY PM-306.1 General. The components of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. PM-306.1.1 Unsafe conditions. Where any of the following conditions cause the component or system to be beyond its limit state, the component or system shall be determined as unsafe and shall be repaired or replaced to comply with the International Building Code as required for existing buildings: 1. Soils that have been subjected to any of the following conditions: 1.1 Collapse of footing or foundation system; 1.2 Damage to footing, foundation, concrete or other structural element due to soil expansion; 1.3 Adverse effects to the design strength of footing, foundation, concrete or other structural element due to a chemical reaction from the soil; 1.4 Inadequate soil as determined by a geotechnical investigation; 1.5 Where the allowable bearing capacity of the soil is in doubt; or 1.6 Adverse effects to the footing, foundation, concrete or other structural element due to the ground water table. 2. Concrete that has been subjected to any of the following conditions: 2.1 Deterioration; 2.2 Ultimate deformation; 2.3 Fractures; 2.4 Fissures; 2.5 Spalling; 2.6 Exposed reinforcement; or 2.7 Detached, dislodged or failing connections. 3. Aluminum that has been subjected to any of the following conditions: 3.1 Deterioration; 3.2 Corrosion; 3.3 Elastic deformation; 3.4 Ultimate deformation; 3.5 Stress or strain cracks; 3.6 Joint fatigue; or 3.7 Detached, dislodged or failing connections. 4. Masonry that has been subjected to any of the following conditions: 4.1 Deterioration; 4.2 Ultimate deformation; 4.3 Fractures in masonry or mortar joints; 4.4 Fissures in masonry or mortar joints; 4.5 Spalling; 4.6 Exposed reinforcement; or 4.7 Detached, dislodged or failing connections. 5. Steel that has been subjected to any of the following conditions: 5.1 Deterioration; 5.2 Elastic deformation; 5.3 Ultimate deformation; 5.4 Metal fatigue; or 5.5 Detached, dislodged or failing connections. 6. Wood that has been subjected to any of the following conditions: 6.1 Ultimate deformation; 6.2 Deterioration; 6.3 Damage from insects, rodents and other vermin; 6.4 Fire damage beyond charring; 6.5 Significant splits and checks; 6.6 Horizontal shear cracks; 6.7 Vertical shear cracks; 6.8 Inadequate support; 6.9 Detached, dislodged or failing connections; or 6.10 Excessive cutting and notching. Exceptions: 1. When substantiated otherwise by an approved method. 2. Demolition of unsafe conditions shall be permitted when approved by the code official. SECTION PM-307 HANDRAILS AND GUARDRAILS PM-307.1 General. Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface which is more than 30 inches (762 mm) above the floor or grade below shall have guards. Handrails shall not be less than 30 inches (762 mm) high or more than 42 inches (1067 mm) high measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guards shall not be less than 30 inches (762 mm) high above the floor of the landing, balcony, porch, deck, or ramp or other walking surface. Exception: Guards shall not be required where exempted by the adopted building code. SECTION PM-308 RUBBISH AND GARBAGE PM-308.1 Accumulation of rubbish or garbage. All exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage. PM-308.2 Disposal of rubbish. Every occupant of a structure shall dispose of all rubbish in a clean and sanitary manner by placing such rubbish in approved containers, and shall also dispose of all recyclable materials (material listed in subsection 10-717(2)(a)) by placing such materials in an approved container required by Section PM-308.2.1. PM-308.2.1 Rubbish storage facilities. The owner of every occupied premises shall supply approved covered containers for rubbish, and a separate, approved container for recyclable materials. The owner of any premises containing ten or more dwelling units shall provide one rubbish and one recycling container in the area of the building designated as the lobby or foyer or other designated areas inside the premises, without obstructing ingress or egress; or in a secure outside area adjacent to the premises, not in a public right-of-way, and at a minimum distance of five (5) feet from any entrance to the premises. No more than two (2) containers may be placed in each of the permitted areas. Each container shall be made of non-combustible material, have a tight-fitting lid, and have a maximum capacity of twenty (20) gallons. The owner of the premises shall be responsible for the regular removal of the contents of the said containers. PM-308.2.2 Refrigerators. Refrigerators and similar equipment not in operation shall not be discarded, abandoned or stored on premises without first removing the doors. PM-308.3 Disposal of garbage. Every occupant of a structure shall dispose of garbage in a clean and sanitary manner by placing such garbage in an approved garbage disposal facility or approved garbage containers. PM-308.3.1 Garbage facilities. The owner of every dwelling shall supply one of the following: an approved mechanical food waste grinder in each dwelling unit; an approved incinerator unit in the structure available to the occupants in each dwelling unit; or an approved leakproof, covered, outside garbage container in a secure location adjacent to the premises, not in a public right-of-way, and at a minimum distance of five (5) feet from any entrance to the premises. PM-308.3.2 Containers. The operator of every establishment producing garbage shall provide, and at all times cause to be utilized, approved leakproof containers provided with close-fitting covers for the storage of such materials until removed from the premises for disposal. PM-308.4 Dumpster enclosures. A dumpster, as defined in Section 10-722 of this Code ("Use of Dumpsters"), that is stored out-of-doors, but not in the public right-of-way, shall be maintained within an enclosure to conceal the dumpster from view from the right-of-way. A dumpster enclosure may be an opaque fence, a shrubbery fence, or an enclosed structure. Any structure built after the effective date of this provision for use as an enclosure for a dumpster shall comply with the requirements of Subcode B of Title 4, The Philadelphia Building Code, and Title 14, The Zoning Code. [History: Amended, Bill No. 150217 (approved May 20, 2015), effective July 1, 2015.] [History: Amended, Bill No. 150217 (approved May 20, 2015), effective July 1, 2015.] [History: Amended, Bill No. 150217 (approved May 20, 2015), effective July 1, 2015.] [History: Added, Bill No. 180348 (approved July 18, 2018).] SECTION PM-309 PEST ELIMINATION PM-309.1 Infestation. All structures shall be kept free from insect and rodent infestation. All structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After extermination, proper precautions shall be taken to prevent reinfestation. PM-309.2 Owner. The owner of any structure shall be responsible for extermination within the structure prior to renting or leasing the structure. PM-309.3 Single occupant. The occupant of a one-family dwelling or of a single-tenant nonresidential structure shall be responsible for extermination on the premises. PM-309.4 Multiple occupancy. The owner of a structure containing two or more dwelling units, a multiple occupancy, a rooming house or a nonresidential structure shall be responsible for extermination in the public or shared areas of the structure and exterior property. If infestation is caused by failure of an occupant to prevent such infestation in the area occupied, the occupant and owner shall be responsible for extermination. PM-309.5 Occupant. The occupant of any structure shall be responsible for the continued rodent and pest-free condition of the structure. Exception: Where the infestations are caused by defects in the structure, the owner shall be responsible for extermination. Exception: With respect to bed bugs, the provisions of Section PM-310 shall supersede the provisions of this Section PM-309.5. PM-309.6 Vacant lots. The owner of a vacant lot is required to perform yearly inspections and rat remediation by a licensed pest control company. Certification of each inspection and remediation must be filed with the department within seven days of completion. Exception: Side yards or lots that are continuously maintained as a garden are not subject to this requirement. The Department of Public Health and the Department of Licenses and Inspections is authorized to issue regulations to implement and enforce Section PM-309.6. [History: Added, Bill No. 190106-A (approved December 30, 2019), effective January 1, 2021.] [History: Added, Bill No. 210902 (approved March 2, 2022)] SECTION PM-310 BED BUG ELIMINATION PM-310.1 The definitions of Chapter 9-4800 of the Code ("Responsibilities Concerning Bed Bug Infestation") shall apply to this Section. PM-310.2 All structures shall be kept free from bed bug infestation. When an infestation is suspected, a reasonable inspection shall be performed. All structures in which bed bugs are found shall be promptly exterminated by a pest management professional, following best management practices. After extermination, proper precautions shall be taken to prevent re-infestation. PM-310.3 Where a property is leased or operated by a dwelling facility operator, the owner, operator and property manager of the rented property or dwelling facility shall be responsible for inspection of suspected infestation, remediation of an infestation and precautions taken to prevent re-infestation, as further established in Chapter 9-4800. PM-310.4 The provisions of this Section PM-310 shall be enforced by the Department of Licenses and Inspections. [History: Added, Bill No. 190106-A (approved December 30, 2019), effective January 1, 2021.] SECTION PM-311 [Reserved] SECTION PM-312 TEMPORARY CONSTRUCTION PM-312.1 Approval: Temporary construction of scaffolding, sidewalk sheds, and similar devices erected in conjunction with any repair, maintenance or abatement activity shall be approved in accordance with the building code. PM-312.2 Duration: Temporary construction as provided in Section PM-312.1 shall be in place for only such time as is necessary for the activity to be completed with due diligence and shall be removed within 30 days after completion of the activity served by the temporary construction. SECTION PM-313 PRIVATE PARKING LOTS PM-313.1 General: All owners and operators of private parking lots shall comply with the requirements of this Section PM-313, the Zoning Code, and the Philadelphia Building Code. PM-313.2 Barriers: A permanent substantial barrier shall be maintained around the private parking lot area. Such barrier shall be constructed of metal or masonry and shall be: 1. a wall which is not less than 2 feet in height; 2. metal or masonry posts 4 to 6 inches in diameter placed not more than 5 feet apart nor less than 30 inches in height and connected by metal pipes, rods, fencing or chains; or 3. concrete curbing, at least six inches high by four inches wide, permanently located so that any parked vehicle does not encroach on a footway, adjacent property, or into an area where parking is not permitted. PM-313.3 Surfacing: All areas of the private parking lot shall be surfaced in accordance with regulations issued by the Department of Streets to prevent the spread of dust, dirt or mud. These regulations shall require the use of permanent paving materials: 1. on private parking lots which are used to store or park commercial vehicles; and 2. on private parking lots with a parking area of 2,500 square feet or more. PM-313.4 Use of Streets: The owner of a private parking lot shall not: 1. use or permit the use of any part of any street or sidewalk for the parking or storing of motor vehicles in connection with the operation of a motor vehicle repair or sales businesses. 2. cause or permit the shoveling, plowing or otherwise moving of snow from the private parking lot onto any street or sidewalk. SECTION PM-314 PIERS AND OTHER WATERFRONT STRUCTURES PM-314.0 General. In order to confirm and maintain the structural integrity of their structures, the owners of piers, bulkheads, wharves, docks, and other structures that have structural elements partly or totally below water along the shorelines of the Delaware River, Schuylkill River, or estuaries shall inspect and submit a structural assessment report to the code official on a triennial basis with the first report due no later than January 1, 2003. Subsequent reports will be due every three years thereafter. The structural assessment report shall be subject to the provisions of Sections PM-314.1 through PM-314.7. Exceptions: 1. The reporting requirement shall not apply to pipelines, bridges, dams, utility towers, tram towers, and water and wastewater discharge and intake structures. 2. The reporting requirement shall not apply to vacant piers and other waterfront structures provided: 2.1 A barrier to human occupancy is maintained at all points of access from the on-shore side of the pier or other waterfront structure. 2.2 The owner files an "Affidavit of Vacant Pier" with the code official. 2.3 The owner maintains a vacant property license. 2.4 The pier or other waterfront structure is posted on all sides, in a visible and conspicuous manner, with "Danger - No Trespassing" signs. 3. The reporting requirement shall not apply to bulkheads in Fairmount Park. 4. The reporting requirements shall not apply to bulkheads along public rights-of-way regulated by other entities. PM-314.1 Minimum qualification of inspection personnel: The personnel involved in the inspection of piers and other waterfront structures shall possess the following qualifications: 1. Project engineer: A professional engineer registered in the Commonwealth of Pennsylvania shall be designated as the project engineer and shall prepare the structural assessment report. The project engineer shall have at least five years' experience in the field of marine structure construction and design techniques with specific verifiable knowledge of relieving platforms, high water structures, and cellular structure. 2. Team leader: All underwater inspections shall be led by and under the direction of a team leader who shall be a professional engineer registered in the Commonwealth of Pennsylvania. The team leader shall have at least three years' experience in the field of marine structure construction and design techniques. The team leader shall also be a qualified diver or shall use a video monitor to assess and record the divers' inspections. 3. Divers: Underwater inspections shall be performed by divers who are graduates of a commercial diving school. Divers shall have completed at least 80 hours of instruction specifically related to structural inspections or shall have at least six months verifiable wharf builder experience in the Delaware bay, river, or estuary. PM-314.2 Inspections: The inspections required by this Section shall be classified as follows: 1. Routine inspections: Routine inspections shall be performed and a structural assessment report prepared at least once every three years as set forth in Section PM-314.0. The inspections shall include: 1.1 Topside inspections: Topside inspection of the above-water portions of the pier or other waterfront structure. 1.2 Underwater inspections: Underwater inspection by personnel qualified to perform such inspections, of those portions of the pier or other waterfront structure that cannot be inspected above water. 2. Post-event inspection: A post-event inspection shall be performed, and a structural assessment report submitted, following a damage-causing event such as impact by vessel, major flood, ice flow, or similar event. PM-314.2.1. Previous inspections: Prior to performing a routine or post-event inspection of a pier or waterfront structure, the Project Engineer shall review previous reports, inspections, and evidence of repairs made in the past three (3) year period, including confirmation that all areas previously determined to require remediation in less than three (3) years (as noted in any previous report) have been addressed. The results shall be included in the structural assessment report. PM-314.3 Structural assessment rating: A rating system conforming to the following criteria shall be used in the structural assessment report to describe the overall condition of the pier or other waterfront structure: 1. Safe - No visible damage or only minor to moderate defects or deterioration observed, but no overstressing observed. Structural elements may show very minor deterioration, but no overstressing observed. No repairs are required. 2. Safe with a Repair and Maintenance Program - All primary structural elements are sound but minor to moderate defects or deterioration observed. Areas of moderate to advanced deterioration may be present but do not significantly reduce the load-bearing capacity of the structure. Repairs are recommended and may need to be carried out with moderate urgency. 3. Unsafe - Advanced deterioration, overstressing, or breakage may have significantly affected the load- bearing capacity of primary structural components. Local failures are possible and loading restrictions may be necessary. Repairs may need to be carried out on a high-priority basis. The structure, or a portion thereof, must be posted with maximum permitted live load certificate(s) and the use restricted or portions barricaded until repairs are completed. Where widespread failure is possible, all occupancy must cease immediately and the structure barricaded and posted. The pier or other waterfront structure, or a portion thereof, must remain closed until repairs are completed and the structure deemed Safe. PM-314.4 Structural assessment report: Structural assessment reports shall be sealed by the project engineer. Each report shall consist of the following sections: 1. Introduction - The introduction to the report shall include: 1.1 Description of the facility including use (function) and loading conditions. 1.2 Scope of work including any limitations affecting inspections dictated by the owner or site conditions. 1.3 Description of the inspection including equipment, test methods date, time, weather, stage of tide, and the names and qualifications of the survey party. 2. Existing conditions - The existing conditions section of the report shall include the following. Data and results shall be documented by drawings/sketches and pictures and shall be reported in a factual manner without comment or analysis. 2.1 Results of topside and underwater inspections. 2.2 Special testing accomplished in the field. 2.3 Results of laboratory testing. 3. Evaluation - Evaluate the structure based upon the existing conditions, previous inspections, current use (function), and loading conditions. The overall structural assessment rating pursuant to Section PM-314.3 shall be included in this Section. 4. Recommendations - The report shall contain: 4.1 Recommendations for repairs or replacement including any temporary measures that must be taken before completion of the repairs. 4.2 Restrictions of use, and required posting(s) of live load certificate(s). PM-314.4.1 Summary report. The Project Engineer shall also submit a summary of the written report to the code official in a form determined by the code official. The code official may by regulation impose a processing fee, not to exceed one hundred dollars ($100), that must be paid upon submission of the summary of the written report. PM-314.4.2 Submission period. Structural assessment reports and summary reports shall be submitted to the code official within sixty days of physical inspection. PM-314.5 Unsafe Conditions. 1. Upon discovery of any Unsafe condition, the Project Engineer shall immediately notify the owner of the pier or other waterfront structure by electronic mail or by fax; and shall, within 12 hours of discovery, notify the code official in writing in an electronic format determined by the code official. 2. Within twenty-four (24) hours of being notified of an Unsafe condition by a Project Engineer, the owner of a pier or other waterfront structure shall take any actions necessary as recommended by the Project Engineer to protect public safety, such as posting, restricting occupancy or closing the structure. 3. The owner shall designate a professional engineer to develop a remediation plan, detailing the extent of the required repairs and temporary measures to ensure public safety. The engineer shall provide periodic structural observations prior to the remediation work and throughout the repair process as required by the Building Code and shall inform the Department if oversight responsibilities are terminated by the owner. 4. Within ten (10) days of the issuance of a building permit to repair an Unsafe condition, the owner of a pier or other waterfront structure shall commence work to correct the condition and work shall continue without interruption until the Unsafe condition has been corrected. 5. Upon completion of the repairs, the designated professional engineer shall reinspect the structure and submit a sealed statement to the Department that the structure has been made Safe. PM-314.5.1 Posting and restricted occupancy: Where an Unsafe condition is reported, the following actions shall be taken based upon the recommendations of the Project Engineer, as detailed in the structural assessment report: 1. Post Maximum Permitted Live Load Certification - Live load certification signs, approved by the code official, shall be conspicuously posted. 2. Barriers - Install barriers and post approved signage to prevent access to specific areas identified by the Project Engineer. 3. Restrict Occupancy - Immediately cease operation of any pier or other waterfront structure, or portion thereof, determined by the Project Engineer to be in unsafe condition. Post "Danger - No Trespassing" signs on all sides including the on-shore and out-shore sides. Install a barrier to prevent access to the pier or other waterfront structure, or portion thereof, from all points of access. PM-314.6 Conditions That Are Safe with a Repair and Maintenance Program: The owner of the pier or waterfront structure is responsible for ensuring that the conditions described in the report as Safe with a Repair and Maintenance Program are repaired and the actions identified by the Project Engineer are completed within the time frame designated by the Project Engineer or by such time necessary to prevent a condition from becoming an Unsafe condition, whichever is sooner. PM-314.7 Appeals: The owner of the pier or other waterfront structure may appeal the findings set forth in the Project Engineer's report to the Board of Building Standards. Such appeal must be filed within thirty (30) days of the receipt or filing of the report, and a second Project Engineer's report shall be submitted within thirty (30) days of filing the appeal. The filing and pendency of such an appeal shall stay the requirement for making repairs as set forth in Section PM-314.5, but not the requirement for taking actions necessary to protect public safety as set forth in Section PM-314.5.1. 1. Upon consideration of any such appeal, the Board shall issue a recommendation to the Commissioner either to grant the appeal; deny the appeal; or grant the appeal with such proposed modifications to the Project Engineer's findings as the Board deems consistent with the intent of this Section. The Commissioner thereafter shall make the final determination on the appeal. 2. The owner of the pier or other waterfront structure may appeal the determination of the Commissioner to the Board of License and Inspection Review, pursuant to the procedures set forth in Section A-803.1 of The Administrative Code. [History: Amended, Bill No. 180746 (approved January 3, 2019).] [History: Added, Bill No. 180746 (approved January 3, 2019).] [History: Added, Bill No. 180746 (approved January 3, 2019).] [History: Added, Bill No. 180746 (approved January 3, 2019).] [History: Amended, Bill No. 180746 (approved January 3, 2019).] [History: Amended, Bill No. 180746 (approved January 3, 2019).] [History: Amended, Bill No. 180746 (approved January 3, 2019).] [History: Added, Bill No. 180746 (approved January 3, 2019).] [History: Added, Bill No. 180746 (approved January 3, 2019).] [History: Amended, Bill No. 180746 (approved January 3, 2019).] [History: Amended, Bill No. 180746 (approved January 3, 2019).] [History: Added, Bill No. 180746 (approved January 3, 2019).] SECTION PM-315 PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES OF BUILDINGS PM-315.1 Definitions. The following definitions shall apply to this Section PM-315: 1. Affected Buildings. All buildings six or more stories in height; all buildings with any appurtenance in excess of 60 feet in height; and any building located in the following areas, other than one- or two-family dwellings, greater than two stories. 2. Professional. A Commonwealth of Pennsylvania licensed Professional Engineer experienced in the practice of structural engineering or a licensed Registered Architect knowledgeable in the design, construction, and inspection of building facades. 3. Safe. A condition of a building wall or any appurtenance thereto that is neither an Unsafe condition nor Safe with a Repair and Maintenance Program. 4. Safe with a Repair and Maintenance Program. A condition of a building's exterior wall or any appurtenance thereto or any part thereof that the Professional does not consider Unsafe at the time of inspection, but requires repairs or maintenance within a time period designated by the Professional in order to prevent its deterioration into an Unsafe condition. 5. Unsafe condition. A condition of a building's exterior wall or any appurtenance thereto or part thereof that is dangerous to persons or property and requires prompt remedial action. PM-315.2 Inspections Required. 1. The owner of each Affected Building shall be responsible for retaining a Professional to conduct periodic inspections of exterior walls and any appurtenances thereto, except for those parts of any exterior wall which are less than twelve inches from the exterior wall of an adjacent building, and to prepare and file a report on such inspection as required by this Section. 2. For Affected Buildings, the first inspection required by this Section shall be conducted as shown in the following schedule: Construction Date | Report to be completed no later than: Prior to and including 1950 | June 30, 2011 1951 - 1970 | June 30, 2012 1971 - 1980 | June 30, 2013 1981 - 1990 | June 30, 2014 1991 - 2005 | June 30, 2015 If the date of construction cannot be determined by the owner, the first inspection must be performed by June 30, 2011. For all other buildings, the first inspection shall be conducted, and required report shall be filed, within ten years after the certificate of occupancy was issued. 3. Following the Initial Inspection, an Affected Building shall be re-inspected, and the required report shall be filed, on a five-year cycle based on the original schedule. 4. If all facades of an Affected Building have been substantially restored during the five years immediately preceding the date of any required inspection, the owner may apply to the code official for a waiver of the required inspection. The owner shall submit with such application such information as the code official determines is necessary to enable it to evaluate the request. The code official shall grant the waiver if it determines that the recent facade restoration obviates the need for an inspection until the next inspection cycle. PM-315.3 Inspection Procedures. 1. Before inspecting an Affected Building, the retained Professional shall review previous reports, inspections, and evidence of repairs made in the past 5 year period, including confirmation that all areas previously determined to require remediation in less than 5 years (as noted in any previous report) have been addressed. 2. The inspection shall be conducted by or under the supervision of the Professional, and performed to the best of his/her knowledge and belief. The Professional shall determine the extent of the inspection required, based upon the known history of the building, the nature of the materials used, and the conditions observed. The Professional shall determine methods employed in the inspection, but need not be physically present at the location where the inspection is made. 3. The methods used to inspect a building shall permit a physical, hands-on inspection of the building. The Professional may use other methods of inspection as deemed appropriate, except that a physical inspection from a scaffold or other observation platform is required for a representative sample of the exterior wall. The Professional shall determine what constitutes a representative sample. 4. The Professional shall employ the appropriate professional standard of care to detect distressed conditions such as delaminating, separating, splitting or fracturing of material or components as well as movement or displacement indicative of unsound facade materials or loss of structural support. If a distressed condition is identified, the Professional shall order any other inspections and/or tests that may be required to determine the significance and probable cause of the observed distress. 5. During the course of the inspection, photographs shall be taken and/or sketches made to properly document the location of all conditions observed that are either Unsafe or Safe with a Repair and Maintenance Program. 6. Upon discovery of any Unsafe condition the Professional shall immediately notify the owner of the building by electronic mail or by fax; and shall, within 12 hours of discovery, notify the code official in writing and in an electronic format determined by the code official. PM-315.4 Report Requirements. 1. The Professional shall submit to the owner of the building a written report as to the result of each inspection, certifying that the inspection was performed and completed in accordance with this Code, and detailing all conditions not classified as Safe. The Professional shall also submit a summary of the written report to the code official in a form determined by the code official. The code official may by regulation impose a processing fee, not to exceed one hundred dollars ($100), that must be paid upon submission of the summary of the written report. If the report identifies an Unsafe condition, then the Professional, within 24 hours of completion of the report, shall file the full report with the code official in writing and in an electronic format determined by the code official. The owner or its agent shall retain all written reports submitted pursuant to this Section and keep them readily available for inspection by the code official. 2. The report shall include, on the front page, the name and license number of the Professional and shall be signed, sealed and dated by the Professional in accordance with the professional registration laws of the Commonwealth of Pennsylvania, and shall include: 2.1 The address and the location from the nearest intersection. 2.2 The name, mailing address, and telephone number of the owner of the building and of the owner's agent or person in charge, possession or control of the building, if any. 2.3 A description of the building, including number of stories, height, plan dimensions, usage, age and type of exterior wall construction, and system of water management. 2.4 A brief history of any settlements, repairs, revisions to exterior enclosures, if available. 2.5 The date of the start and completion of the inspection, a detailed description of the procedures used in making the inspection, and the extent and location of all physical inspections performed. 2.6 A report of all conditions including but not limited to significant deterioration and movement observed as well as a statement concerning the apparent water-tightness of the exterior surfaces, and the deleterious effect of exterior appurtenances, including exterior fixtures, flagpoles, signs, parapets, copings, guard rails, window frames (including hardware and lights), window guards, window air conditioners, flower boxes, and similar items. The report shall classify each such condition as Safe, Unsafe, or Safe with a Repair and Maintenance Program. 2.7 The probable causes of the reported conditions. 2.8 The status of the exterior maintenance. 2.9 For any conditions listed in the previously filed report (if any), whether such conditions have been repaired and/or maintained as recommended in that report. 2.10 Recommendations for repairs or maintenance, if appropriate, including the recommended time frame for the repairs or maintenance to be performed. 2.11 The classification of the building according to the following scheme: a. "Unsafe", if there is at least one unsafe condition. b. "Safe with a Repair and Maintenance Program", if there is a condition that is "Safe with Repair and Maintenance Program" and there are no Unsafe conditions. c. "Safe", in all cases other than a or b. 2.12 Photographs and/or sketches documenting the locations of any conditions that are either Unsafe or Safe with a Repair and Maintenance Program. 2.13 A statement by the Professional indicating which repairs and/or maintenance require the obtaining of work permits prior to their commencement. 2.14 A statement signed by the owner or agent of the building, acknowledging receipt of a copy of the report and acknowledging all required repairs and/or maintenance (if any) and the recommended time frame for performing such repairs and/or maintenance. 2.15 The Professional's certification that the physical inspection was performed in accordance with applicable rules and regulations and within the appropriate professional standard of care. 2.16 The Professional's seal and signature. 2.17 Such other matters as the code official may by regulation require. 3. The Professional may submit an amended report within thirty (30) days of the initial submission. The amended report shall clearly indicate any change from the initial report and all reasons for such changes. PM-315.5 Unsafe Conditions. 1. Within twenty-four (24) hours of being notified of an Unsafe condition by a Professional, the owner of a building shall take any actions necessary to protect public safety, such as erecting sidewalk sheds, fences, and/or safety netting. Such actions shall be considered as an effort to remedy an emergency situation and appropriate permit applications shall be submitted within the next three (3) days to the code official. 2. Within ten (10) days of the receipt or filing of a report identifying an Unsafe condition, the owner of a building shall commence work to correct the condition and work shall continue without interruption until the Unsafe condition has been corrected, unless there has been an unforeseen delay (e.g. weather, labor strike). Within two weeks after the Unsafe condition has been corrected, the Professional shall reinspect the building and file with the code official a detailed amended report stating the condition of the building. PM-315.6 Conditions That Are Safe with a Repair and Maintenance Program. 1. The owner of the building is responsible for ensuring that the conditions described in the report as "Safe with a Repair and Maintenance Program" are repaired and the actions identified by the Professional are completed within the time frame designated by the Professional or by such time necessary to prevent a condition from becoming an Unsafe condition, whichever is sooner PM-315.7 Extensions. 1. The code official may grant an extension of time of up to ninety (90) days to begin the repairs required to remove an Unsafe condition or to repair a Safe with Repair and Maintenance Program condition, after receipt and review of an initial extension application submitted by the Professional which includes: 1.1 Proof that the premises have been made safe by means of a shed, fence, or other appropriate measures. 1.2 A copy of the contract indicating the scope of work necessary to remedy the Unsafe condition(s). 1.3 The Professional's estimate of the length of time required for repairs, and a notarized affidavit by the owner of the building or its agent that work will be completed within such time. 2. A further extension of time will be considered by the code official only upon receipt and review of a further extension application which details that one of the following is met: 2.1 The work has been substantially completed, but there has been an unforeseen delay (e.g. weather, labor strike). 2.2 Unforeseen circumstances (e.g., fire, building collapse). 2.3 The nature of hazard requires more than 90 days to remove (e.g., new wall to be built). PM-315.8 Appeals. The owner of the building may appeal the findings set forth in the Professional's initial report or amended report to the Board of Building Standards. Such appeal must be filed within thirty (30) days of the receipt or filing of the report, and must include a second Professional's report. The filing and pendency of such an appeal shall stay the requirement for making repairs as set forth in Section PM-315.5.2, but not the requirement for taking actions necessary to protect public safety as set forth in Section PM-315.5.1. 1. Upon consideration of any such appeal, the Board shall issue a recommendation to the code official either to grant the appeal; deny the appeal; or grant the appeal with such proposed modifications to the Professional's findings as the Board deems consistent with the intent of this Section. The code official thereafter shall make the final determination on the appeal. 2. The owner of the building may appeal the determination of the code official to the Board of License and Inspection Review, pursuant to the procedures set forth in Section A-803.2 of The Administrative Code. [History: Enrolled bill read "PM-305.5.1."] SECTION PM-316 PERIODIC INSPECTION OF PRIVATE BRIDGES PM-316.1 Definitions. The following definitions shall apply to this Section PM-316: 1. Private Bridge. An elevated structure that crosses over any part of a public right-of-way or publicly- owned pedestrian, bicycle or equestrian trail that typically allows for pedestrian passage between buildings or supports building systems and processing equipment or allows for vehicular access to private property, and often is referred to as a skyway, catwalk, skybridge or skywalk. A private bridge does not include a structure inspected as required by a federal authority such as the Federal Highway Administration or the Federal Railroad Administration. 2. Professional. A Commonwealth of Pennsylvania licensed Professional Engineer experienced in the practice of structural engineering. 3. Safe. A condition of a private bridge or any appurtenance thereto that is neither an Unsafe condition nor Safe with a Repair and Maintenance Program. 4. Safe with a Repair and Maintenance Program. A condition of a private bridge or any appurtenance thereto or any part thereof that the Professional does not consider Unsafe at the time of inspection, but requires repairs or maintenance in order to prevent its deterioration into an Unsafe condition. 5. Unsafe Condition. A condition of a private bridge or any appurtenance thereto or part thereof that is dangerous to persons or property and in need of prompt remedial action. PM-316.2 Inspections Required. 1. The owner of a private bridge shall be responsible for retaining a Professional to conduct periodic inspections of the structure and any appurtenances thereto, and to prepare and file a report on such inspection as required by this Section. 2. The initial inspection required by this Section shall be conducted, and the required report shall be filed, on or before July 1, 2017. If the construction of the private bridge was completed after July 1, 2007, the first inspection shall be conducted within ten years after the certificate of occupancy was issued or, in such case where the bridge is not connected to a building, construction of the bridge was completed. All reports shall be filed within three months of the inspection that is the subject of the report. 3. Following the initial inspection, and every inspection thereafter, a private bridge shall be re-inspected, and the required report shall be filed within five years of the filing of the report concerning the previous inspection. 4. If a private bridge has been substantially restored during the five years immediately preceding the date of any required inspection report, the owner may submit to the code official a request for a waiver of the required inspection. The owner shall submit with such application such information as the code official determines is necessary to enable evaluation of the request. The code official shall grant the waiver if it determines that the restoration obviates the need for an inspection until a date established by the Code official. PM-316.3 Inspection Procedures. 1. Before inspecting a private bridge, the retained Professional shall review previous reports, inspections, and evidence of repairs made in the 5 year period prior to the inspection, including confirmation that all areas previously determined to require remediation in less than 5 years (as noted in any previous report) have been addressed. 2. The inspection shall be conducted by or under the supervision of the Professional. The Professional shall determine the extent of the inspection required, based upon the known history of the private bridge, the nature of the materials used, and the conditions observed. The Professional shall determine the methods employed in the inspection. The Professional need not be physically present at the location where the inspection is made. 3. The methods used to inspect a private bridge shall include a physical, hands-on inspection of the structure, its support systems and any appurtenances attached to the private bridge. The Professional may use other methods of inspection as deemed appropriate. 4. The Professional shall employ the appropriate professional standard of care to detect distressed conditions such as spalling, delaminating, separating, splitting or fracturing of material or components as well as movement or displacement indicative of unsound exterior covering materials or loss of structural support. If a distressed condition is identified, the Professional shall order any other inspections and/or tests that may be required to determine the significance and probable cause of the observed distress. 5. During the course of the inspection, photographs shall be taken and/or sketches made to properly document the location of all conditions observed that are either Unsafe or Safe with a Repair and Maintenance Program. 6. Upon discovery of any Unsafe condition the Professional shall immediately notify the owner of the private bridge by electronic mail or by fax; and shall, within 12 hours of discovery, notify the code official in writing and in an electronic format determined by the code official. PM-316.4 Report Requirements. 1. The Professional shall submit to the owner of the private bridge a written report as to the result of each inspection. The Professional shall also submit a summary of the written report to the code official in a form determined by the code official. The code official may by regulation impose a processing fee, not to exceed one hundred dollars ($100), that must be paid upon submission of the summary of the written report. If the report identifies an Unsafe condition, then the Professional, within 24 hours of completion of the report, shall file the full report with the code official in writing and in an electronic format determined by the code official. The owner or owner's agent shall retain all written reports submitted pursuant to this Section and keep them readily available for inspection by the code official. 2. The report shall include, on the front page, the name and license number of the Professional and the date of the report, and shall include the following: 2.1 The addresses of any buildings connected to the private bridge and the public right-of-way or trail spanned by the private bridge. 2.2 The name, mailing address, and telephone number of the owner of the private bridge and of the owner's agent or person in charge, possession or control of the private bridge, if any. 2.3 A description of the private bridge, including number of stories, clearance above the public way, plan dimensions, usage, age and type of exterior wall construction, and system of water management. 2.4 A brief history of any known changes, repairs or revisions to the private bridge. 2.5 The date of the start and completion of the inspection, a detailed description of the procedures used in making the inspection, and the extent and location of all physical inspections performed. 2.6 A report of all conditions, including, but not limited to, significant deterioration, and movement, the apparent watertightness of the exterior surfaces and any deleterious impact or condition of exterior appurtenances, including exterior fixtures, signs, copings, window frames, hardware, lights and similar items. The report shall classify each such condition as Safe, Unsafe, or Safe with a Repair and Maintenance Program. 2.7 The probable causes of the reported conditions. 2.8 The status of ongoing maintenance efforts. 2.9 For any conditions listed in any previously filed report, whether such conditions have been repaired and/or maintained as recommended in that report. 2.10 Recommendations for repairs or maintenance, if appropriate, including the recommended time frame for the repairs or maintenance to be performed. 2.11 The classification of the private bridge overall according to the following scheme: a. "Unsafe", if there is at least one unsafe condition. b. "Safe with a Repair and Maintenance Program", if there is a condition that is "Safe with Repair and Maintenance Program" and there are no Unsafe conditions. c. "Safe", in all cases other than a or b. 2.12 Photographs and/or sketches documenting the locations of any conditions that are either Unsafe or Safe with a Repair and Maintenance Program. 2.13 A statement by the Professional indicating which repairs and/or maintenance require work permits prior to their commencement. 2.14 A statement signed by the owner or agent of the private bridge, acknowledging receipt of a copy of the report and acknowledging any required repairs and/or maintenance and the recommended time frame for performing such repairs and/or maintenance. 2.15 The Professional's certification that, to the best of his or her knowledge and belief, the physical inspection was performed in accordance with applicable rules and regulations, including the provisions of this Section, and within the appropriate professional standard of care. 2.16 The Professional's seal and signature in accordance with the professional registration laws of the Commonwealth of Pennsylvania. 2.17 Such other matters as the code official may require by regulation. 3. The Professional may submit an amended report. The amended report shall clearly identify any change from the initial report and all reasons for such changes. PM-316.5 Unsafe Conditions. 1. Within twenty-four (24) hours of being notified of an Unsafe condition by a Professional, the owner of a private bridge shall take any actions necessary to protect public safety, such as closing the private bridge and erecting sidewalk sheds, fences, and/or safety netting. Such actions shall be considered part of an effort to remedy an emergency situation and applications for any required permit shall be filed with the code official within three (3) days of notification. 2. Within ten (10) days of the receipt of a report identifying an Unsafe condition, the owner of a private bridge shall commence work to correct the condition and work shall continue without interruption until the Unsafe condition has been corrected. Within two weeks after the Unsafe condition has been corrected, the Professional shall reinspect the private bridge and file with the code official a detailed amended report concerning the condition of the private bridge. PM-316.6 Conditions That Are Safe with a Repair and Maintenance Program. The owner of the private bridge is responsible for ensuring that the conditions described in the report as "Safe with a Repair and Maintenance Program" are repaired and the actions identified by the Professional are completed within the time frame designated by the Professional or by such time necessary to prevent a condition from becoming an Unsafe condition, whichever is sooner. PM-316.7 Extensions. 1. Upon application of the owner, the code official may grant an extension of time of up to ninety (90) days to begin the repairs required to remove an Unsafe condition or to repair a Safe with Repair and Maintenance Program condition, provided such application includes: 1.1 Proof that the structure has been made safe by means of a shed, fence, netting or other appropriate measures. 1.2 A copy of the contract indicating the scope of work necessary to remedy the condition(s) requiring action. 1.3 The Professional's estimate of the length of time required for repairs and statement of agreement to the need for an extension. 1.4 A notarized certification by the owner of the private bridge or owner's agent that work will be completed within the established time. 2. A further extension of time will be considered by the code official only upon receipt and review of a further extension application which details that one of the following justifications warrants and extension: 2.1 The work has been substantially completed, but there has been an unforeseen delay (e.g. weather, labor strike). 2.2 Unforeseen circumstances (e.g., fire, building collapse). 2.3 The nature of the hazard requires more than 90 days to address (e.g., new private bridge to be built). PM-316.8 Appeals. 1. The owner of the private bridge may appeal the findings set forth in the Professional's initial report or amended report to the Board of Building Standards. Such appeal must be filed within thirty (30) days of the receipt or filing of the report, and must include a second Professional's report. The filing and pendency of such an appeal shall stay the requirement for making repairs as set forth in Section PM-316.5.2, but not the requirement for taking actions necessary to protect public safety as set forth in Section PM-316.5.1. 2. Upon consideration of any such appeal, the Board shall issue a recommendation to the Commissioner either to grant the appeal; deny the appeal; or grant the appeal with such proposed modifications to the Professional's findings as the Board deems consistent with the intent of this Section. The Commissioner thereafter shall make the final determination on the appeal. 3. The owner of the private bridge may appeal the determination of the Commissioner to the Board of License and Inspection Review, pursuant to the procedures set forth in The Administrative Code. [History: Added, Bill No. 160202 (approved April 26, 2016), effective January 1, 2017.] CHAPTER 4 LIGHT, VENTILATION AND OCCUPANCY LIMITATIONS SECTION PM-401 GENERAL PM-401.1 Scope. The provisions of this Chapter shall govern the minimum conditions and standards for light, ventilation and space for occupying a structure. PM-401.2 Responsibility. The owner of the structure shall provide and maintain light, ventilation and space conditions in compliance with these requirements. A person shall not occupy as owner-occupant, or permit another person to occupy, any premises that do not comply with the requirements of this Chapter. PM-401.3 Alternative devices. In lieu of the means for natural light and ventilation herein prescribed, artificial light or mechanical ventilation complying with the International Building Code shall be permitted. SECTION PM-402 LIGHT PM-402.1 Habitable spaces. Every habitable space shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be eight percent (8%) of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than 3 feet (914 mm) from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room. Exception: Where natural light for rooms or spaces without exterior glazing areas is provided through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight percent (8%) of the floor area of the interior room or space, but not less than 25 square feet (2.33 m 2). The exterior glazing area shall be based on the total floor area being served. PM-402.2 Common halls and stairways. Every common hall and stairway in residential occupancies, other than in one- and two-family dwellings, shall be lighted at all times with at least a 60-watt standard incandescent light bulb for each 200 square feet (19 m 2) of floor area or equivalent illumination, provided that the spacing between lights shall not be greater than 30 feet (9144 mm). In other than residential occupancies, means of egress, including exterior means of egress, stairways shall be illuminated at all times the building space served by the means of egress is occupied with a minimum of 1 footcandle (11 lux) at floors, landings and treads. PM-402.3 Other spaces. All other spaces shall be provided with natural or artificial light sufficient to permit the maintenance of sanitary conditions, and the safe occupancy of the space and utilization of the appliances, equipment and fixtures. SECTION PM-403 VENTILATION PM-403.1 Habitable spaces. Every habitable space shall have at least one openable window. The total openable area of the window in every room shall be equal to at least forty-five percent (45%) of the minimum glazed area required in Section PM-402.1. Exception: Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight percent (8%) of the floor area of the interior room or space, but not less than 25 square feet (2.33 m 2). The ventilation openings to the outdoors shall be based on a total floor area being ventilated. PM-403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section PM-403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated. PM-403.3 Cooking facilities. Unless approved through the certificate of occupancy, cooking shall not be permitted in any rooming unit or dormitory unit, and a cooking facility or appliance shall not be permitted to be present in the rooming unit or dormitory unit. Exceptions: 1. Where specifically approved in writing by the code official. 2. Devices such as coffee pots and microwave ovens shall not be considered cooking appliances. PM-403.4 Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space. PM-403.5 Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted outside the structure in accordance with the manufacturer's instructions. Exception: Listed and labeled condensing (ductless) clothes dryers. SECTION PM-404 OCCUPANCY LIMITATIONS PM-404.1 Privacy. Dwelling units, hotel units, housekeeping units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces. PM-404.2 Minimum room widths. A habitable room, other than a kitchen, shall not be less than 7 feet (2134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than 3 feet (914 mm) between counterfronts and appliances or counterfronts and walls. PM-404.3 Minimum ceiling heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than 7 feet (2134 mm). Exceptions: 1. In one- and two-family dwellings, beams or girders spaced not less than 4 feet (1219 mm) on center and projecting not more than 6 inches (152 mm) below the required ceiling height. 2. Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a ceiling height of not less than 6 feet 8 inches (2033 mm) with not less than 6 feet 4 inches (1932 mm) of clear height under beams, girders, ducts and similar obstructions. 3. Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a clear ceiling height of at least 7 feet (2134 mm) over not less than one-third of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of 5 feet (1524 mm) or more shall be included. PM-404.4 Bedroom and living room requirements. Every bedroom and living room shall comply with the requirements of Sections PM-404.4.1 through PM-404.4.5. PM-404.4.1 Room area. Every living room shall contain at least 120 square feet (11.2 m 2) and every bedroom shall contain at least 70 square feet (6.5 m 2). PM-404.4.1.1 Minimum dimensions: A habitable room, other than a kitchen, shall not be less than seven feet (2133 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than three feet (914 mm) between counterfronts and appliances or counterfronts and walls PM-404.4.2 Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces. Exception: Units that contain fewer than two bedrooms. PM-404.4.3 Water closet accessibility. Every bedroom shall have access to at least one water closet and one lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to at least one water closet and lavatory located in the same story as the bedroom or an adjacent story. PM-404.4.4 Prohibited occupancy. Kitchens and nonhabitable spaces shall not be used for sleeping purposes. PM-404.4.5 Other requirements. Bedrooms shall comply with the applicable provisions of this code including, but not limited to, the light, ventilation, room area, ceiling height and room width requirements of this Chapter; the plumbing facilities and water-heating facilities requirements of Chapter 5; the heating facilities and electrical receptacle requirements of Chapter 6; and the smoke detector and emergency escape requirements of Chapter 7. PM-404.5 Overcrowding. The number of persons occupying a dwelling unit shall not create conditions that, in the opinion of the code official, endanger the life, health, safety or welfare of the occupants. PM-404.6 Efficiency unit. Nothing in this Section shall prohibit an efficiency living unit from meeting the following requirements: 1. A unit occupied by not more than two occupants shall have a clear floor area of not less than 220 square feet (20.4 m2). A unit occupied by three occupants shall have a clear floor area of not less than 320 square feet (29.7 m 2). These required areas shall be exclusive of the areas required by Items 2 and 3. 2. The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided. 3. The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower. 4. The maximum number of occupants shall be three. PM-404.7 Food preparation. All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage. CHAPTER 5 PLUMBING FACILITIES AND FIXTURE REQUIREMENTS SECTION PM-501 GENERAL PM-501.1 Scope. The provisions of this Chapter shall govern the minimum plumbing systems, facilities and plumbing fixtures to be provided. PM-501.2 Responsibility. The owner of the structure shall provide and maintain such plumbing facilities and plumbing fixtures in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any structure or premises which does not comply with the requirements of this Chapter. [P] SECTION PM-502 REQUIRED FACILITIES PM-502.1 Dwelling units. Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. The lavatory shall be placed in the same room as the water closet or located in close proximity to the door leading directly into the room in which such water closet is located. A kitchen sink shall not be used as a substitute for the required lavatory. PM-502.2 Rooming houses. At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. PM-502.3 Hotels. Where private water closets, lavatories and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants. PM-502.4 Employees' facilities. A minimum of one water closet, one lavatory and one drinking facility shall be available to employees. PM-502.4.1 Drinking facilities. Drinking facilities shall be a drinking fountain, water cooler, bottled water cooler or disposable cups next to a sink or water dispenser. Drinking facilities shall not be located in toilet rooms or bathrooms. PM-502.5 Public toilet facilities. Public toilet facilities shall be maintained in a safe sanitary and working condition in accordance with the International Plumbing Code. Except for periodic maintenance or cleaning, public access and use shall be provided to the toilet facilities at all times during occupancy of the premises. PM-502.6 Schools. Structures or portions of structures used for Educational Group E occupancy, as defined in Subcode "B" of Title 4 (The Philadelphia Building Code), shall be equipped with one drinking fountain for every 100 students or fraction thereof, based on the facility's actual student enrollment. At least one fountain shall be on each occupied floor of the building, without regard to the number of students. Water dispensers may be substituted for not more than fifty percent (50%) of the required number of drinking fountains. Following June 1, 2025, the above applicable requirements for drinking fountains shall only be satisfied by drinking fountains or water dispensers made of lead-free materials, where commercially available, that include the following elements: 1. A highly effective, filter certified to meet or exceed NSF/ANSI 53 and 42 requirements; 2. A filter change indicator, known as an integral performance indication device as specified NSF/ANSI 53; and 3. A bottle filling station controlled by the user for the purpose of dispensing drinking water into a receptacle such as a cup or bottle. Exception: Child care facilities that are not part of a school are not regulated under this subsection. [History: Added, Bill No. 160472 (approved June 28, 2016), effective September 26, 2016; amended, Bill No. 220221-A (approved August 31, 2022).] [P] SECTION PM-503 TOILET ROOMS PM-503.1 Privacy. Toilet rooms and bathrooms shall provide privacy and shall not constitute the only passageway to a hall or other space, or to the exterior. A door and interior locking device shall be provided for all common or shared bathrooms and toilet rooms in a multiple dwelling. PM-503.2 Location. Toilet rooms and bathrooms serving hotel units, rooming units or dormitory units or housekeeping units, shall have access by traversing not more than one flight of stairs and shall have access from a common hall or passageway PM-503.3 Location of employee toilet facilities. Toilet facilities shall have access from within the employees' working area. The required toilet facilities shall be located not more than one story above or below the employees' working area and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m). Employee facilities shall either be separate facilities or combined employee and public facilities. Exception: Facilities that are required for employees in storage structures or kiosks, which are located in adjacent structures under the same ownership, lease or control, shall not exceed a travel distance of 500 feet (152 m) from the employees' regular working area to the facilities. PM-503.4 Floor surface. In other than dwelling units, every toilet room floor shall be maintained to be a smooth, hard, nonabsorbent surface to permit such floor to be easily kept in a clean and sanitary condition. [P] SECTION PM-504 PLUMBING SYSTEMS AND FIXTURES PM-504.1 General. All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition. PM-504.2 Fixture clearances. Plumbing fixtures shall have adequate clearances for usage and cleaning. PM-504.3 Plumbing system hazards. Where it is found that a plumbing system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, inadequate venting, cross connection, backsiphonage, improper installation, deterioration or damage or for similar reasons, the code official shall require the defects to be corrected to eliminate the hazard. SECTION PM-505 WATER SYSTEM PM-505.1 General. Every sink, lavatory, bathtub or shower, drinking fountain, water closet or other plumbing fixture shall be properly connected to either a public water system or to an approved private water system. All kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be supplied with hot or tempered and cold running water in accordance with the International Plumbing Code. [P] PM-505.2 Contamination. The water supply shall be maintained free from contamination, and all water inlets for plumbing fixtures shall be located above the flood-level rim of the fixture. Shampoo basin faucets, janitor sink faucets and other hose bibs or faucets to which hoses are attached and left in place, shall be protected by an approved atmospheric-type vacuum breaker or an approved permanently attached hose connection vacuum breaker. PM-505.3 Supply. The water supply system shall be installed and maintained to provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks. PM-505.4 Water heating facilities. Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 110°F (43°C). A gas-burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided. An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. [P] SECTION PM-506 SANITARY DRAINAGE SYSTEM PM-506.1 General. All plumbing fixtures shall be properly connected to either a public sewer system or to an approved private sewage disposal system. PM-506.2 Maintenance. Every plumbing stack, vent, waste and sewer line shall function properly and be kept free from obstructions, leaks and defects. PM-506.3 Grease interceptors. Where it has been determined that a grease interceptor is not being maintained and serviced as intended by this code and the manufacturer's instructions, an approved interceptor monitoring system shall be provided or a maintenance program shall be established with documentation submitted to the code official. [P] SECTION PM-507 STORM DRAINAGE PM-507.1 General. Drainage of roofs and paved areas, yards and courts, and other open areas on the premises shall not be discharged in a manner that creates a public nuisance. CHAPTER 6 MECHANICAL AND ELECTRICAL REQUIREMENTS SECTION PM-601 GENERAL PM-601.1 Scope. The provisions of this Chapter shall govern the minimum mechanical and electrical facilities and equipment to be provided. PM-601.2 Responsibility. The owner of the structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises which does not comply with the requirements of this Chapter. SECTION PM-602 HEATING FACILITIES PM-602.1 Facilities required. Heating facilities shall be provided in structures as required by this Section. PM-602.2 Residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 68°F (20°C) in all habitable rooms, bathrooms and toilet rooms. Cooking appliances shall not be used to provide space heating to meet the requirements of this Section. PM-602.3 Heat supply. Heat shall be supplied continuously at the temperature and in the rooms specified in Section PM-602.2 from October 1 to April 30 inclusive, and in addition thereto during the months of May or September when the outside temperature falls below 60 degrees F (15 degrees C) by every owner or operator of every two- family dwelling, multiple-family dwelling and rooming house except where there are separate heating facilities for each dwelling unit, whose facilities are under the sole control of the occupant of such dwelling unit. Exceptions: 1. When the outdoor temperature is below the winter outdoor design temperature for the locality, maintenance of the minimum room temperature shall not be required provided that the heating system is operating at its full design capacity. The winter outdoor design temperature for the locality shall be as indicated in Appendix D of the International Plumbing Code. 2. In areas where the average monthly temperature is above 30°F (-1°C) a minimum temperature of 65°F (18°C). PM-602.4 [Reserved] PM-602.5 Room temperature measurement. The required room temperatures shall be measured 3 feet (914 mm) above the floor near the center of the room and 2 feet (610 mm) inward from the center of each exterior wall. SECTION PM-603 MECHANICAL EQUIPMENT PM-603.1 Mechanical appliances. All mechanical appliances, fireplaces, solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function. PM-603.2 Removal of combustion products. All fuel-burning equipment and appliances shall be connected to an approved chimney or vent. Exception: Fuel-burning equipment and appliances which are labeled for unvented operation. PM-603.3 Clearances. All required clearances to combustible materials shall be maintained. PM-603.4 Safety controls. All safety controls for fuel-burning equipment shall be maintained in effective operation. PM-603.5 Combustion air. A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel-burning equipment. PM-603.6 Energy conservation devices. Devices intended to reduce fuel consumption by attachment to a fuel- burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled for such purpose and the installation is specifically approved. SECTION PM-604 ELECTRICAL FACILITIES PM-604.1 Facilities required. Every occupied building shall be provided with an electrical system in compliance with the requirements of this Section and Section PM-605. PM-604.2 Service. The size and usage of appliances and equipment shall serve as a basis for determining the need for additional facilities in accordance with NFPA 70. Dwelling units shall be served by a three-wire, 120/240 volt, single-phase electrical service having a rating of not less than 60 amperes. PM-604.3 Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the code official shall require the defects to be corrected to eliminate the hazard. PM-604.3.1 Abatement of electrical hazards associated with water exposure. The provisions of this Section shall govern the repair and replacement of electrical systems and equipment that have been exposed to water. PM-604.3.1.1 Electrical equipment. Electrical distribution equipment, motor circuits, power equipment, transformers, wire, cable, flexible cords, wiring devices, ground fault circuit interrupters, surge protectors, molded case circuit breakers, low-voltage fuses, luminaires, ballasts, motors and electronic control, signaling and communication equipment that have been exposed to water shall be replaced in accordance with the provisions of the International Building Code. Exception: The following equipment shall be allowed to be repaired where an inspection report from the equipment manufacturer or approved manufacturer's representative indicates that the equipment has not sustained damage that requires replacement: 1. Enclosed switches, rated 600 volts or less; 2. Busway, rated 600 volts or less; 3. Panelboards, rated 600 volts or less; 4. Switchboards, rated 600 volts or less; 5. Fire pump controllers, rated 600 volts or less; 6. Manual and magnetic motor controllers; 7. Motor control centers; 8. Alternating current high-voltage circuit breakers; 9. Low-voltage power circuit breakers; 10. Protective relays, meters and current transformers; 11. Low- and medium-voltage switchgear; 12. Liquid-filled transformers; 13. Cast-resin transformers; 14. Wire or cable that is suitable for wet locations and whose ends have not been exposed to water; 15. Wire or cable, not containing fillers, that is suitable for wet locations and whose ends have not been exposed to water; 16. Luminaires that are listed as submersible; 17. Motors; 18. Electronic control, signaling and communication equipment. PM-604.3.2 Abatement of electrical hazards associated with fire exposure. The provisions of this Section shall govern the repair and replacement of electrical systems and equipment that have been exposed to fire. PM-604.3.2.1 Electrical equipment. Electrical switches, receptacles and fixtures, including furnace, water heating, security system and power distribution circuits, that have been exposed to fire, shall be replaced in accordance with the provisions of the International Building Code. Exception: Electrical switches, receptacles and fixtures that shall be allowed to be repaired where an inspection report from the equipment manufacturer or approved manufacturer's representative indicates that the equipment has not sustained damage that requires replacement. SECTION PM-605 ELECTRICAL EQUIPMENT PM-605.1 Installation. All electrical equipment, wiring and appliances shall be properly installed and maintained in a safe and approved manner. PM-605.2 Receptacles. Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. PM-605.3 Luminaires. Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric luminaire. PM-605.3.1 Outdoor lighting fixture: Every owner or operator of every multiple-family dwelling shall provide an outside light over each entrance from the street and in a prominent place in each side yard and rear yard sufficient to illuminate and maintain in service 16 square feet (1.49 m 2) of ground area to the intensity of 3 foot candles (33 lux). The light shall be turned on automatically at sunset and shall remain on until sunrise the following morning. SECTION PM-606 ELEVATORS PM-606.1 [Reserved] PM-606.2 Elevators. In buildings equipped with passenger elevators, at least one elevator shall be maintained in operation at all times when the building is occupied. Exception: Buildings equipped with only one elevator shall be permitted to have the elevator temporarily out of service for testing or servicing. SECTION PM-607 DUCT SYSTEMS PM-607.1 General. Duct systems shall be maintained free of obstructions and shall be capable of performing the required function. CHAPTER 7 FIRE SAFETY REQUIREMENTS SECTION PM-701 GENERAL PM-701.1 Scope. The provisions of this Chapter shall govern the minimum conditions and standards for fire safety relating to structures and exterior premises, including fire safety facilities and equipment to be provided. PM-701.2 Responsibility. The owner of the premises shall provide and maintain such fire safety facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises that do not comply with the requirements of this Chapter. [F] SECTION PM-702 MEANS OF EGRESS PM-702.1 General. A safe, continuous and unobstructed path of travel shall be provided from any point in a building or structure to the public way. Means of egress shall comply with the International Fire Code. PM-702.2 Aisles. The required width of aisles in accordance with the International Fire Code shall be unobstructed. PM-702.3 Locked doors. All means of egress doors shall be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort, except where the door hardware conforms to that permitted by the International Building Code. PM-702.4 Emergency escape openings. Required emergency escape openings shall be maintained in accordance with the code in effect at the time of construction, and the following. Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening. PM-702.5 Exterior stairs and fire escapes. All exterior stairways and fire escapes, as defined in the Fire Code, shall be kept free of snow and ice. The owner of the building shall have weather protecting products applied to all exterior stairways and fire escapes constructed of materials requiring the application of such products in an approved manner and as often as necessary to maintain the stairways and fire escapes in safe condition. Fire escapes and fire escape balconies shall be examined for structural adequacy and safety in accordance with Section F-1011.1. [History: Added, Bill No. 160462 (approved June 28, 2016).] [F] SECTION PM-703 FIRE-RESISTANCE RATINGS PM-703.1 Fire-resistance-rated assemblies. The required fire-resistance rating of fire-resistance-rated walls, fire stops, shaft enclosures, partitions and floors shall be maintained. PM-703.2 Opening protectives. Required opening protectives shall be maintained in an operative condition. All fire and smokestop doors shall be maintained in operable condition. Fire doors and smoke barrier doors shall not be blocked or obstructed or otherwise made inoperable. [F] SECTION PM-704 FIRE PROTECTION SYSTEMS PM-704.1 General. All systems, devices and equipment to detect a fire, actuate an alarm, or suppress or control a fire or any combination thereof shall be maintained in an operable condition at all times in accordance with the International Fire Code. PM-704.1.1 Automatic sprinkler systems. Inspection, testing and maintenance of automatic sprinkler systems shall be in accordance with NFPA 25 and the Philadelphia Fire Code. PM-704.2 Smoke alarms. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and in dwellings not regulated in Group R occupancies, regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements and cellars but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. Single- or multiple-station smoke alarms shall be installed in other groups in accordance with the International Fire Code. [F] PM-704.3 Power source for Smoke Alarms. Single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection. Exceptions: 1. Smoke alarms are permitted to be solely battery powered with 10-year nonremovable (sealed) batteries in existing one- and two-family dwellings built prior to January 1, 1988, where no construction is taking place. 2. Smoke alarms are permitted to be solely battery powered with 10-year nonremovable (sealed) batteries in one- and two-family dwellings that are not served from a commercial power source. 3. Smoke alarms are permitted to be solely battery powered with 10-year nonremovable (sealed) batteries in existing one- and two-family dwellings built prior to January 1, 1988, undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for building wiring without the removal of interior finishes. PM-704.4 Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling unit in Group R-2, R-3, or R-4 and in dwellings not regulated as Group R occupancies, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Exceptions: 1. Interconnection is not required in buildings which are not undergoing alterations, repairs or construction of any kind, except for congregate living facilities as regulated by the Philadelphia Fire Code. 2. Except in congregate living facilities, smoke alarms in existing areas are not required to be interconnected where alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for interconnection without the removal of interior finishes. [History: Amended, Bill No. 180464 (approved July 18, 2018), effective October 1, 2018.] SECTION PM-705 CARBON MONOXIDE ALARMS PM-705.1. Where the use is classified as a Group R-3 or R-4 occupancy, carbon monoxide alarms shall be installed and maintained in accordance with the Philadelphia Fire Code. CHAPTER 8 SPECIAL CONTROLS IN DESIGNATED AREAS SECTION PM-801 LEGISLATIVE PURPOSE PM-801.1 Revitalization areas: The purpose of this Chapter is to promote the public welfare by encouraging the revitalization of deteriorating neighborhood commercial revitalization areas and to provide that a reasonable degree of control may be exercised over the design, construction, alteration and repair of the front faces of commercial buildings in designated neighborhood commercial revitalization areas in order to prevent further deterioration and blight in such areas and to protect surrounding neighborhoods from the adverse effects of deterioration and blight. PM-801.2 Center City: It is further the purpose of this Chapter to promote the public welfare in the Center City Extended Commercial Area by ensuring the continued suitability of the area as the City's primary business district, by encouraging the growth of the hotel and tourism industry therein, and by prohibiting the type of building disrepair that leads to property value depreciation, through the use of the reasonable controls specified herein. Additionally, this Chapter is intended to promote health and safety in the area by eliminating dangerous conditions on properties, including structural weaknesses on appurtenances, exposed electrical elements, broken glass, and solid security shutters which act to block visibility of police and fire personnel. PM-801.3. It is further the purpose of this Chapter to promote the public welfare in other specified neighborhood commercial areas by ensuring the continued visibility of businesses in these areas and to provide that a reasonable degree of control may be exercised over the design, construction, alteration and repair of the front faces of commercial buildings in these designated neighborhoods in order to prevent deterioration and blight. Additionally, this Chapter is intended to promote health and safety in these specified neighborhood commercial areas by eliminating dangerous conditions on properties including, but not limited to, solid security shutters which act to block the visibility of police and fire personnel and which attract graffiti and vandalism. SECTION PM-802 DEFINITIONS PM-802.1 Applicability: In this Chapter, the following definitions shall apply: FRONT FACE: The side of any building abutting on a street which has been designated a neighborhood commercial revitalization area. RIGID: Free of any warping or distortion. Rigid materials shall not include tin. SECTION PM-803 DESIGNATED AREAS PM-803.1 Area descriptions: The designated areas shall consist of those areas described in Sections PM-803.1.1 through PM-803.1.3. PM-803.1.1 Center City: The Center City Extended Commercial Area shall consist of the area bounded by Front street, Vine street, the west side of Eighteenth street, and the south side of Pine street. PM-803.1.2 Historic area: The Main Street Manayunk National Historic District shall consist of the following area: Beginning at a point on the northerly side of Main street, approximately three hundred seventy feet east of Shurs lane, at the eastern boundary of Littlewoods Dyers & Bleachers (4025 Main street); thence extending northwardly approximately one hundred eighty feet along said boundary to a point of the southerly boundary of the Reading Railroad right-of-way, south of Cresson street; thence extending westwardly approximately one thousand eight hundred feet along the southerly boundary of the Reading Railroad right-of-way, to the easterly side of Roxborough avenue; thence extending westwardly approximately eight hundred fifty feet along the southerly side of Cresson street to the easterly side of Levering; thence extending north to the northerly side of Cresson street (sixty feet wide); thence extending westwardly approximately two hundred sixty feet along the northerly side of Cresson street to the easterly boundary of the waiting room and public facilities building of the Manayunk passenger station of the Reading Railroad; thence extending northwardly along the eastern boundary of said facility approximately thirty feet; thence extending westwardly along the northerly boundary of said facility approximately one hundred feet, to a point of the easterly side of Carson street; thence extending southwardly one hundred feet along the easterly side of Carson street, to a point on the southerly side of Cresson street; thence extending westwardly four hundred feet along the southerly side of Cresson street to the westerly side of Green lane; thence continuing westwardly along the southerly boundary of the Reading Railroad right-of-way one hundred fifty feet to a point; thence extending southwardly crossing the Pennsylvania Railroad right-of-way, following the easterly boundary of the Manayunk substation property, one hundred fifty feet to a point on the northerly side of Main street; thence extending westwardly along the northerly side of Main street one thousand one hundred feet to the westerly side of Leverington avenue; thence continuing westwardly along the southern boundary of the Reading Railroad right-of-way approximately five thousand seven hundred feet to a point adjacent to Flat Rock Dam; thence extending southwardly, crossing the canal channel and continuing along the westerly side of the dam structure to the southern bank of the Schuylkill River; thence returning along the easterly side of the dam structure to the westerly tip of Venice Island; thence extending eastwardly along the southern shore of Venice Island nine thousand eight hundred fifty feet to the easterly tip of Venice Island at the lower lock; thence crossing the lower lock channel and continuing eastwardly approximately seven hundred feet along the north bank of the Schuylkill River to the easterly property line of 4026 Main street, thence extending northwardly along said property line approximately one hundred feet to the southerly side of Main street; thence crossing Main street (sixty feet wide), to a point on the northerly side of Main street; at the eastern boundary of Littlewoods Dyers & Bleachers, the first mentioned point and place of beginning. PM-803.1.3 Specified neighborhood commercial areas: Those areas designated in Section PM-804.3.2. PM-803.1.4 1 Leverington Avenue on Venice Island Master Plan: The Main Street Manayunk National Historic District designated in Section PM-803.1.2 above shall specifically exclude that certain approved Residential Mixed-Use-2 (RMX-2) Master Plan for 1 Leverington Avenue on Venice Island allowing for a new residential townhome development in the area generally bounded on the northeast by the Manayunk Canal, on the southeast by Green Lane, on the southwest by the Schuylkill River, and on the northwest by Leverington Avenue with a straight line extending from Leverington Avenue to the Schuylkill River, which Master Plan is on file with the Chief Clerk's Office. [History: Added, Bill No. 170997-A (approved February 14, 2018).] SECTION PM-804 BUILDING STANDARDS APPLICABLE TO DESIGNATED AREAS PM-804.1 Front faces: Within designated areas, the front faces of buildings or structures used for commercial purposes shall conform with the following requirements. PM-804.1.1 Architectural elements: All exposed architectural elements or appurtenances thereto, including facades and business signs, shall be maintained in good structural and decorative repair. All such elements or appurtenances exhibiting substantial conditions of deterioration including rusted finishes, peeling paint, accumulated grime, graffiti, bent, broken or distorted surfaces shall be considered in violation of the provisions of this subsection. For the purpose of this subsection "substantial conditions" shall be considered twenty percent (20%) or more of the surface area; except that within the Center City Extended Commercial Area, any publicly visible graffiti shall be considered "substantial conditions" of deterioration. PM-804.1.2 Other elements: All other unused and exposed elements, including wires, brackets and conduits, shall be removed. PM-804.1.3 Glazing: Except as provided in Section PM-804.1.5, broken window glass shall be replaced. PM-804.1.4 Security devices: All security devices designed to limit or block access to the front face of the buildings or structures used for commercial purposes shall allow for substantial visibility of the front face at all times. Solid shutters shall not be permitted. However, notwithstanding the above, any security device lawfully in existence prior to January 20, 1982 or, in regard to the Center City Extended Commercial Area, lawfully in existence on January 1, 1993, and not in conformance with the provisions of this subsection, shall not be repaired or altered in any substantial manner except to comply with the design specifications of this subsection. PM-804.1.4.1 Finish: Within the Center City Extended Commercial Area, such nonconforming security devices shall be painted in a single solid color and maintained graffiti free at all times. PM-804.1.4.2 Advertising: Advertising shall be prohibited from being placed on shutters. PM-804.1.5 Window openings: Blocking of window openings located on any story above the ground floor shall be permitted. Blocking of window openings shall conform to all requirements of the building code. The blocking of any such openings shall be performed in a neat and workmanlike manner, and only rigid permanent materials shall be permitted. PM-804.2 Historic area standards: Standards within the designated historic area shall be as set forth in Sections PM-804.2.1 through PM-804.2.7 in addition to the requirements of Sections PM-804.1 through PM-804.1.4.2. PM-804.2.1 Permit: No building or portion of the exterior thereof within the historic district shall hereafter be constructed, altered, repaired, demolished, or partially demolished unless a permit has first been obtained from the code official. PM-804.2.2 Approval: All applications for such permits shall be forwarded by the code official to the Historical Commission for review and approval, before issuance of the permit. No permit shall be issued unless the proposed work has been approved by the Historical Commission staff as preserving the historical character of the district. PM-804.2.3 Repair: Original architectural features such as cornices and bays shall not be removed. Deteriorated features shall be repaired where possible. Replacement material where necessary shall duplicate the original as closely as possible. PM-804.2.4 Facings: Refacing of facades, bays, cornices with inappropriate materials such as aluminum siding, or brick veneer shall be prohibited. Existing inappropriate facade facings shall be removed at the termination of the useful life of the facing. Any inappropriate facing material lawfully in existence shall not be repaired or altered in any substantial manner. PM-804.2.5 Elements: Original window and door openings, sills, lintels, and sashes shall be retained and repaired whenever possible. Replacement elements shall match the original appearance in proportion, form, and materials as closely as possible. PM-804.2.6 Storefronts: Original existing storefronts contributing to the character of the district shall be retained and repaired. New storefronts shall be compatible with the proportion, form and materials of the original building. PM-804.2.7 Design: Additions, alterations, and new construction shall be designed so as to be compatible in scale, building materials, and texture, with contributing buildings in the historic district. PM-804.3 Neighborhood commercial areas: Standards within the specified neighborhood commercial areas shall be as set forth in Sections PM-804.3.1 through PM-804.3.1.3. PM-804.3.1 Security devices: In the neighborhood commercial areas specified in Section PM-804.3.2, the following requirements for security devices shall apply. PM-804.3.1.1 Permitted design: All security devices designed to limit or block access to the front face of the buildings or structures used for commercial purposes shall be of open link design and shall allow for substantial visibility of the front face at all times. PM-804.3.1.2 Prohibited design. Solid shutters, solid roll-down security grates or similar devices shall not be permitted. PM-804.3.1.3 Compliance. Any security device lawfully in existence on the effective date of this Section and not in conformance with the provisions of this Section shall not be altered or repaired in any substantial manner unless the alterations or repairs comply with the design specifications of this Section. Such previously existing security devices which are solid shutters shall be painted in a single solid color, shall be maintained graffiti free at all times, and shall not be used for advertising. For purposes of this subsection, "the effective date of this Section" shall mean the effective date of any ordinance adding a specified neighborhood commercial area to this Section. PM-804.3.2 Specified areas: Neighborhood commercial areas shall consist of the following: 1. Both sides of Haverford avenue between City avenue and Brookhaven road. 2. All commercial corridors and neighborhood commercial properties throughout the Ninth Councilmanic District. 3. The East Passyunk Avenue Business Improvement District as delineated in Bill No. 020431 (approved December 17, 2002). 4. All commercial corridors and neighborhood commercial properties throughout the First Councilmanic District not already covered by Section PM-804.3.2(3), relating to the East Passyunk Avenue Business Improvement District. 5. All commercial corridors and neighborhood commercial properties throughout the Tenth Councilmanic District, as defined by Section 20-501 of The Philadelphia Code, relating to boundaries of Councilmanic Districts. CHAPTER 9 ADDITIONAL SPECIAL REQUIREMENTS SECTION PM-901 SPECIAL REQUIREMENTS FOR VACANT PROPERTIES; BLIGHTING PROBLEMS PM-901.1 Vacant Properties. The owner of any vacant building shall keep the interior and exterior of the premises free of garbage and rubbish. The owner of any vacant building shall keep all doors, windows and openings from the roof or other areas in good repair, and shall ensure that the roof is intact and allows for proper stormwater drainage. Where such doors or windows or entrance to openings are readily accessible to trespassers, they shall be kept securely locked, fastened or otherwise secured. The owner shall take any other measures prescribed by the code official to prevent unauthorized entry to the premises by closing all openings with materials approved by the code official. A vacant building, which is not secured against entry shall be deemed unsafe within the meaning of this code. PM-901.2 Blighting Problems. The owner of a building that is a blighting problem, as defined in Section PM-202, shall secure all spaces designed as windows with windows that have frames and glazing and all entryways with doors. Sealing such a property with boards or masonry or other materials that are not windows with frames and glazing or entry doors shall not constitute good repair or being locked, fastened or otherwise secured pursuant to this subsection. SECTION PM-902 SPECIAL REQUIREMENTS FOR FVRP/LVCIPS PM-902.1 FVRPs and LVCIPs. Except as otherwise provided in this subsection, the building owner of a Foreclosed Vacant Residential Property or a Large Vacant Commercial or Industrial Property shall keep all doors, windows and openings from the roof or other areas in good repair. If securely fastened windows and doors fail or are inadequate to prevent trespassers from entering the building, the owner shall close and secure all accessible openings using a commercial-quality, 14 gauge, rust-proof steel security panel or door, or such other materials deemed by the code official to provide an equivalent level of protection considering the specific characteristics of a property and its location. Security panels and doors shall be secured from the building interior, allow emergency access such as by key, and have an exterior finish that allows for easy removal of graffiti. PM-902.2. It shall be a separate offense, for which a separate fine may be imposed, for the owner to fail to secure each separate door, window, or other entrance or opening as required by this Section PM-902. PM-902.3 Large Vacant Commercial or Industrial Property ("LVCIP") and Foreclosed Vacant Residential Property ("FVRP"). The owner of an LVCIP or FVRP shall cause an inspection of such property to be performed within fifteen (15) days of acquiring the property, and at least once every two weeks thereafter. Such inspections shall determine whether the property is in compliance with the requirements of this code. Where an LVCIP or FVRP does not comply with the requirements of this code, its owner shall promptly cause appropriate remediation to be undertaken. PM-902.4 Designation of Property Manager: Any owner of an LVCIP or FVRP who resides outside the City and does not customarily and regularly attend or maintain a business office in the City shall designate a property manager able to perform the inspections and any remediation required under Section PM-902.3. This requirement shall not prohibit an owner who resides in the City or customarily and regularly attends or maintains a business office in the City from designating a property manager, nor shall it prohibit any owner from serving as the property manager for an LVCIP or FVRP owned by that owner. PM-902.5. The owner of an LVCIP or FVRP shall immediately register such property with the code official on a form provided by the code official. A new owner of an LVCIP or FVRP shall register such property no later than five days following the transfer of title. The registration shall include the address of the LVCIP or FVRP, the name, address, and telephone number of the owner, the name, address, and twenty-four (24) hour contact telephone number of the property manager responsible for inspecting the property and performing any remediation under Section PM-902.3 and such other information the code official deems appropriate. The owner of an LVCIP or FVRP shall, in the manner and time set forth in subsection 9-3902(6)(c), inform the code official of any change in the foregoing required information. Registration of an LVCIP pursuant to this subsection shall be accompanied by certification that the property's fire protection systems are operating properly pursuant to F-915.1, or by documentation of exemption pursuant to F-311. PM-902.6 Documentation of Inspections. The code official may require an owner or a property manager to provide documentation, satisfactory to the code official, of performance of the inspections and any remediation under Section PM-902.3. PM-902.7 Posting. The owner of an LVCIP or FVRP shall post the property with the owner's name and address, the name and address of the property manager responsible for inspecting the property and performing remediation under Section PM-902.3, and the twenty-four (24) hour contact telephone number of the property manager. The posting shall be made using a weather-resistant sign no smaller than eighteen (18) inches by twenty-four (24) inches, and shall be in plain view, with print that may be easily read from the sidewalk or street immediately abutting the property. PM-902.8 Violations. With respect to an LVCIP or FVRP, any of the following shall constitute a violation of this Section PM-902, and shall be in addition to any other violation of this Code: 1. Failure to correct any violation of this code cited in a notice of violation under A-502.1 within the time limitation set forth in such notice for performing such correction. 2. Failure to perform any inspection required by Section PM-902.3. PM-902.9 Notice. Where the code official determines that any vacant building is in violation of this Section PM-902, a written notice of that determination shall be given to the registered owner together with an appropriate order to comply with this code, and a copy shall be posted in a conspicuous place on the premises. Such written notice shall indicate the number of doors, windows or other entrances or openings to the building that the owner has failed to secure or seal in violation of Section PM-902.1. Such notice shall be in addition to a notice, if any, designating a property as a blighting problem. PM-902.10 Service. Notices required by this subsection shall be served on the owner in accordance with the Philadelphia Administrative Code. PM-902.11 Compliance. The owner of any vacant building which is in violation of this subsection shall, upon written notice, either eliminate the violation(s) or demolish the building. Where immediate compliance is not feasible, the owner shall notify the code official in writing within 10 days of the notice served by the code official of the steps taken to correct the conditions, together with an estimate of the time required to fully comply with the provisions of the code. PM-902.12 Penalties. If the owner does not comply with the notice or fails to correct the conditions specified in the code official's notice within the required period of time, the owner shall be subject to penalties set forth in the Philadelphia Administrative Code, provided that it shall be a separate offense, for which a separate fine may be imposed, for the owner to fail to secure or seal each separate door, window or other entrance or opening enumerated in the written notice required by Section PM-902.9. As provided in Section A-601.4, each day that each such separate offense continues after issuance of a notice or order shall also be deemed a separate offense for which a separate fine may be imposed. PM-902.13 Abatement. If the owner does not comply with the order of the code official to correct the conditions prohibited by this subsection, the code official is authorized to correct the conditions or demolish the building with its own forces or by contract and charge the costs thereof to the owner, and with the approval of the Law Department, collect the costs, including administrative costs, by lien, or otherwise. PM-902.14. A vacant structure deemed unsafe pursuant to this subsection for failure to secure it against entry shall be sealed with commercial-quality, 14 gauge, rust-proof steel security panels or doors, or such other materials deemed by the code official to provide an equivalent level of protection considering the specific characteristics of a property and its location, when any of the following criteria have been met: 1. The structure is an LVCIP or FVRP subject to the requirements of this Section PM-902; 2. A separate violation has been issued with respect to the structure for failure to secure it against entry; or 3. The code official determines that the structure is especially hazardous based on any of the following factors: there is evidence of unauthorized entry into the structure, based on complaints, police information or records, or physical evidence; the property is located in an area with a high rate of crime connected to vacant buildings or lots, based on statistical crime numbers or consultation with the corresponding police district; the structure creates a significant fire hazard, due to its noncompliance with Fire Code requirements, condition, materials, size, or proximity to residential housing; and any additional factors identified by the code official. The code official may convene or utilize a task force to review relevant evidence and make recommendations to the code official. A notice, order, or other action made pursuant to this subsection may be appealed pursuant to A-803 by the property's owner, a neighboring resident, the representative of a neighborhood nonprofit or community group, or any other aggrieved person. PM-902.15. A structure that qualifies as an LVCIP subject to the requirements of this Section PM-902 that is a significant fire hazard shall be deemed imminently dangerous. The code official shall promulgate such regulations, policies, or procedures as it may deem necessary to aid in the administration and enforcement of this subsection. SECTION PM-903 EMERGENCY NUISANCE ABATEMENT PROGRAM PM-903.0 Definitions. The following definitions shall apply to this Section PM-903: 1. Abandoned Property. A dwelling or vacant lot which has been determined by the code official to have been unoccupied for one year or more, and against which there are outstanding municipal liens, or the owner of which is delinquent in the payment of Real Estate Taxes, Water and Sewer Rents, or other municipal claims. For purposes of this definition, a lot shall be considered vacant and unoccupied if no structure is built thereon and no lawful, productive activity has been conducted on the lot with the owner's authorization within the past twelve (12) months. 2. Emergency Nuisance Abatement Area. Any ward or part of a ward of the City determined by City Council to contain such a great number of abandoned properties constituting unsafe structures or unfit dwellings as defined in this code, that traditional abatement methods have been unsuccessful and that resulting neighborhood blight and deterioration are so widespread and unchecked that an emergency exists. PM-903.1. The following areas have been determined by City Council to constitute the Emergency Nuisance Abatement Areas to which this Section applies: 1. Third Ward. 2. Sixth Ward. 3. Eleventh Ward. 4. Twelfth Ward. 5. Thirteenth Ward. 6. Fourteenth Ward. 7. Sixteenth Ward. 8. Eighteenth Ward. 9. Nineteenth Ward. 10. Twentieth Ward. 11. Twenty-second Ward. 12. Twenty-fourth Ward. 13. Twenty-seventh Ward. 14. Twenty-eighth Ward. 15. Twenty-ninth Ward. 16. Thirty-second Ward. 17. Thirty-sixth Ward. 18. Thirty-seventh Ward. 19. Forty-third Ward. 20. Forty-fourth Ward. 21. Forty-sixth Ward. 22. Forty-seventh Ward. 23. Forty-ninth Ward. 24. Fifty-first Ward. 25. Fifty-ninth Ward. 26. Sixtieth Ward. 27. First Ward. 28. Second Ward 29. Thirty-ninth A Ward. 30. Thirty-ninth B Ward. 31. Fifth Ward. 32. Twenty-fifth Ward. 33. Thirty-first Ward. 34. Forty-fifth Ward. PM-903.2 Additional Emergency Nuisance Abatement Areas. In addition to the foregoing wards, with respect to vacant lots only, the following areas shall also constitute Emergency Nuisance Abatement Areas: 1. Ninth Ward. 2. Seventeenth Ward. 3. The Seventeenth, Eighteenth, Twentieth and Twenty-fourth Divisions of the Thirty-third Ward. 4. Seventh Ward. 5. Third, Eighth, Ninth and Thirteenth through Seventeenth Divisions of the Eighteenth Ward. 6. Twenty-third Ward. 7. First through Seventeenth, Nineteenth, and Twenty-first through Twenty-third Divisions of the Thirty-third Ward. 8. Fourteenth through Seventeenth, Twenty-second through Twenty-fourth and the Twenty-sixth Divisions of the Thirty-fifth Ward. 9. Second through Fourth, Sixth and the Seventh Divisions of the Forty-second Ward. 10. Thirtieth Ward. 11. Fortieth A Ward. 12. Fortieth B Ward. 13. Forty-eighth Ward. 14. Fourth Ward. 15. Twenty-first Ward. 16. Thirty-fourth Ward. 17. Thirty-eighth Ward. 18. Fifty-second Ward. 19. Forty-first Ward. 20. Fifty-fourth Ward. 21. Fifty-fifth Ward. 22. Sixty-second Ward. 23. Sixty-fourth Ward. 24. Fourth through Ninth, Twentieth, Twenty-third and Twenty-sixth Divisions of Fifty-seventh Ward. 25. First through Ninth, and Eleventh through Twenty-third Divisions of the Sixty-fifth Ward. PM-903.3. The code official, after consultation with the Vacant Property Review Committee, is authorized to enter into Abatement Agreements with bona fide residents of the City in accordance with this Section PM-903. PM-903.4 Correct Conditions. An Abatement Agreement shall be a contract to correct the conditions resulting in an unsafe or unfit designation, any costs of which shall be charged, as the work is completed, to the owner of the abandoned property and collected by lien, in accordance with Section PM-903.6. PM-903.5 Occupancy. The contracting individual and members of his or her household shall enter and occupy an abandoned property dwelling meeting the requirements of this Section PM-903, or, in the case of a vacant lot, the contracting individual or entity and his or her agents shall take such steps as may be necessary, all for the purpose of abating the unsafe or unfit conditions resulting from the vacancy of and the condition of the premises in accordance with the terms of an abatement plan entered into by the City and the contracting individual pursuant to Section PM-903.11. The terms of the abatement plan shall be incorporated into the Abatement Agreement. PM-903.6 Consideration. Consideration for the services of the contracting individual in abating the unsafe or unfit conditions shall be solely limited to the City's promise to bring the property to Sheriff's Sale at the earliest practicable date; to bid at the Sheriff's Sale at the amount of all outstanding municipal liens and claims, including any liens resulting from the costs attributable to completed portions of the abatement plan; and to either: 1. Authorize the Commissioner of Public Property to make the property available for disposition through the Gift Property Program, for the purposes of which disposition the contracting individual shall be considered the first applicant; or 2. Compensate the contracting individual in the amount of any liens satisfied at Sheriff's Sale which are attributable to the Abatement Agreement if the City is an unsuccessful bidder, or if the owner of the abandoned property exercises his or her right to redeem it within statutory time limits. PM-903.7 Breach. Any wilful, material breach of an abatement plan and/or Abatement Agreement by a contracting individual shall render the Abatement Agreement void without further action on the part of the City. PM-903.8 Procedure. Nothing in this Section PM-903 shall be construed to relieve the code official from any bidding procedures required by law. PM-903.9 Indemnity. The contracting individual shall agree to indemnify and hold the City harmless from any damages, costs or other liabilities for any injuries to his or her person or property or to the person or property of any member of his or her household, or of their licensees or invitees, arising from any defective condition or work performed on the premises, or arising from any other causes whatsoever related to the occupancy or performance under the Abatement Agreement. PM-903.10 Limited authority. The Abatement Agreement shall confer no power on the contracting individual, his or her heirs or assigns, to obligate the City to any third parties in any manner whatsoever. PM-903.11 Criteria. In order for a property to be included in the Emergent Nuisance Abatement Program, the following criteria shall be met: 1. The Property must be located in an Emergency Nuisance Abatement Area; 2. The code official has determined pursuant to this code that the property constituted an unsafe structure or unfit dwelling; or, in the case of a vacant lot, the code official has determined that a vacant lot is unsafe. For purposes of this Section, a lot is unsafe if it presents a hazard to the community because of existing violations of this code. 3. The owner of the property has failed to comply, after proper notice, with any abatement order issued by the code official pursuant to this code; or, with respect to a vacant lot, the code official has issued a notice to the owner of the lot stating that the code official has determined the lot to be unsafe, order the owner to abate the unsafe condition, and notifying the owner that the property is subject to the provisions of this Section, and the owner has failed to comply with such order. 4. The property is an abandoned property; and 5. The property shall be determined by the Gift Property Program, or its successor, to be structurally sound (in the case of a dwelling) and susceptible to rehabilitation. PM-903.12 Abatement plan. before entering into any Abatement Agreement with an applicant, the Gift Property Program, or its successor, shall agree with the applicant of an abatement plan to include: the nature and extent of repairs necessary to abate each condition on the subject premises causing the unsafe or unfit designation; the reasonable monetary value of the labor of the applicant and his or her agents and of the materials and services which will be required to cure each such condition; and a reasonable timetable for completing the abatement plan. PM-903.13 Regulations. The Department of Public Property, the Office of Housing and Community Development or its successor, and the code official are authorized to promulgate regulations to govern their respective responsibilities pursuant to this Section PM-903. SECTION PM-904 CHRONIC NON-COMPLIANT OWNER PM-904.1 Chronic Non-Compliant Owners. Any person who violates one or more provision of the PM Code designated in this Section PM-904.1 with respect to a residential property on separate days, at a frequency set forth in Section PM-904.2, shall, in addition to the underlying PM Code violations, be considered a Chronic Non- Compliant Owner, subject to a separate penalty for such offense as set forth in Section A-601. Each Chronic Non-Compliant Owner violation, after the first, shall constitute a separate offense. 1. PM Code Chapter 3 (General Requirements), but not including Section PM-305 (Interior Structure); 2. Section PM-507 (Storm Drainage); 3. PM Code Chapter 8 (Special Controls in Designated Areas); and 4. PM Code Chapter 9 (Additional Special Requirements). PM-904.2 Frequency of Violations. Violations at the following frequencies shall render a person a Chronic Non- Compliant Owner, as set forth in Section PM-904.1. 1. Six occasions of violation within a two-year period; or 2. Three occasions of violation within a two-year period, provided that, with respect to each such violation, the violation is not remedied within 30 days of provision of, nor an appeal pending regarding, the initial notice of violation. [History: Added, Bill No. 160365-A (approved October 19, 2016).] SECTION PM-905 BUILDING MANIFEST REQUIREMENT 1. Definitions. For purposes of this Section, the following terms shall have the following meanings: Building Manifest. A document that lists the name of every Resident, the phone number of every Resident, the date the document was most recently updated, and identifies special needs that a Resident believes would help Responders assist the Resident in an emergency situation, as voluntarily identified for a building manager. Department. The Department of Licenses and Inspections. High-rise building. Structures that meet the definition of High-Rise Building pursuant to Section B-202 of the Philadelphia Building Code and contain a Household Living use pursuant to subsection 14-601(2)(a) of the Philadelphia Zoning Code. Mid-rise building. A residential building that has an active housing rental license with the Department for at least 25 residential units, but does not meet the standard of a High-rise building. Resident. A person that resides in a High-rise building or a Mid-rise building. Responder. A person designated or trained to respond to an emergency, including but not limited to, officials in the Office of Emergency Management. 2. Creation and Maintenance of a Building Manifest Required. The manager of a High-rise building or a Mid-rise building shall create and maintain an up-to-date Building Manifest. a. A Building Manifest shall be considered up-to-date if it has been updated within the past 12 months. 3. Building Manifest Required to Be Kept On-Site. The manager of a High-rise building or a Mid-rise building shall keep an up-to-date Building Manifest on-site, in hard-copy form, for the purpose of providing the Building Manifest to Responders in the event of an emergency. 4. Enforcement. a. For the purpose of enforcing the provisions of this Section, notices of violation shall be issued by authorized Department inspectors or any other persons authorized to enforce ordinances. Such notices of violation shall be issued under the procedures set forth in Section 1-112, except that the amount required to be remitted in response to a notice of violation shall be one hundred fifty dollars ($150). [History: Added, Bill No. 200116 (approved July 13, 2020), effective July 13, 2021.] SECTION PM-906 NECESSARY URGENT REPAIR PROGRAM. 1. Definitions. For purposes of this Section, the following terms shall have the following meanings: Department. The Department of Licenses and Inspections. Qualifying Multi-Family Building. A residential building that has a Household Living Use pursuant to subsection 14-601(2)(a)(.3) of the Philadelphia Zoning Code and, in which, a public nuisance is present. Qualifying Vacant Single-Family Building. A residential building that has been unoccupied for one year or more, has a Household Living Use pursuant to subsection 14-601(2)(a)(.1) of the Philadelphia Zoning Code and, in which, the presence of a public nuisance is significantly impacting a neighboring property. 2. A significant violation of one or more of the following Sections of the Philadelphia Property Maintenance Code shall be considered a public nuisance: a. Section PM-504.3: Plumbing Systems – Hazards; b. Section PM-506.1: Plumbing Systems – Sanitary Drainage; c. Section PM-506.2: Plumbing Systems – Sanitary Maintenance; d. Section PM-602.2: Mechanical & Electrical – Heating Residential; e. Section PM-602.3: Mechanical – Heating Residential Temp; f. Section PM-603.1: Mechanical – Mechanical Equipment. 3. The Department may, by regulation, designate additional significant violations of the Philadelphia Property Maintenance Code that shall be considered public nuisances and have the same effect as significant violations listed in Section PM-906 2. of this Code. 4. Owners and authorized agents of Qualifying Multi-family Buildings and Qualifying Vacant Single-Family Buildings are required to immediately repair any public nuisance listed in Section PM-906 2. of this Code, after being provided with service of reasonable notice of the public nuisance. 5. Failure to repair any such public nuisance within one (1) month of provision of reasonable notice of the existence of the public nuisance, including a summary of the repairs to be completed, shall authorize the Department to cause the public nuisance to be repaired. a. If, at the time of the notice, the owner or authorized agent of the Qualifying Multi-Family Building or Qualifying Vacant Single-Family Building is engaged in a good-faith effort to repair the public nuisance at least as soon as it could be corrected by the Department, the Department shall not commence any repairs unless and until the owner or authorized agent interrupts or ceases the repairs or the Department determines that emergency repairs or temporary safeguards are required. 6. The owner shall be responsible for, and shall be billed for, all expenses incurred by the Department pursuant this Section PM-906, which, after a period of non-payment of thirty (30) days, shall be filed as a lien against the property. [History: Added, Bill No. 210205 (became law November 18, 2021), effective November 18, 2022.] CHAPTER 10 REFERENCED STANDARDS This Chapter lists the standards that are referenced in various Sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the Section or Sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section PM-102.7. ASME | American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 | Standard reference number | Title | Referenced in Code Section number PM- A17.1/CSA B44-2007 | Safety Code for Elevators and Escalators | 606.1 ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 | Standard reference number | Title | Referenced in Code Section number PM- F1346-91 (2003) | Performance Specifications for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs | 303.2 ICC | International Code Council 500 New Jersey Avenue, NW 6th Floor Washington, DC 20001 | Standard reference number | Title | Referenced in Code Section number PM- IBC-09 | International Building Code® | 102.3, 201.3, 401.3, 702.3 IFC-09 | International Fire Code® | 201.3, 604.3.1.1, 604.3.2.1, 702.1, 702.2, 704.1, 704.2 IEBC-09 | International Existing Building Code® | 305.1.1, 306.1.1 IFGC-09 | International Fuel Gas Code® | 102.3 IMC-09 | International Mechanical Code® | 102.3, 201.3 NFPA | National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269 | Standard reference number | Title | Referenced in Code Section number PM- 25-08 | Inspection, Testing and Maintenance of Waterbased Fire Protection Systems | 704.1.1 70-08 | National Electrical Code | 102.4, 201.3, 604.2 SUBCODE "R" (THE PHILADELPHIA RESIDENTIAL CODE) Article R-1.0 Adoption of the “2021 International Residential Code”, pursuant to the Pennsylvania Uniform Construction Code Act (“Act”), with state amendments and local amendments that were in effect prior to enactment of the Act or approved pursuant to Section 503 of the Act. § R-1.1 The “2021 International Residential Code”, as published by the International Code Council, is hereby adopted as the Residential Code of the City of Philadelphia and is incorporated as if fully set forth herein, subject to the amendments provided in this Subcode R. Editor's note: The 2021 International Residential Code can be found at: https://codes.iccsafe.org/content/IRC2021P1 § R-1.1.1 The numbers of all local amendments shall be preceded with the prefix “R-”. § R-1.1.2 Throughout the code, references to “International” codes or “ICC” codes shall be deemed to refer to the “Philadelphia” codes of the same name. [History: Added, Bill No. 030782 (approved December 31, 2003); repealed and replaced, Bill No. 180174 (approved June 6, 2018). Section 2 of Bill No. 180174 provides: "The provisions of Section 1 shall be effective October 1, 2018, and upon taking effect replace and supersede the "Regulations Pursuant to the Philadelphia Residential Code" related to R-101.2 of the Department of Licenses and Inspections. Additional amendments to this Subcode, developed by the UCC Review and Advisory Council, will be established by Regulation of the PA Department of Labor and Industry prior to October 1, 2018. Pursuant to the UCC, such amendments shall become part of this code as if adopted herein." Repealed and replaced, Bill No. 220638 (approved December 14, 2022); repealed and replaced, Bill No. 260395 (approved June 12, 2026).] CHAPTER 1 SCOPE AND ADMINISTRATION [Delete contents of Chapter 1 and replace as follows:] SECTION R-R101 SCOPE AND GENERAL REQUIREMENTS R-R101.1 Title. These provisions shall be known as the Philadelphia Amendments to the International Residential Code and will be referred to herein as the “Philadelphia Residential Code” or “this code”. R-R101.2 Scope. The provisions of this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress and their accessory structures not more than three stories above grade plane in height. Exception: The following shall be permitted to be constructed in accordance with this code where provided with a residential fire sprinkler system complying with Section P2904: 1. Live/work units located in townhouses and complying with the requirements of Section 419 of the International Building Code. 2. Owner-occupied lodging houses with five or fewer guestrooms. 3. A care facility with five or fewer persons receiving custodial care within a dwelling unit. 4. A care facility with five or fewer persons receiving medical care within a dwelling unit. 5. A care facility for five or fewer persons receiving care that are within a single-family dwelling. R-R101.3 Purpose. The purpose of this code is to provide minimum requirements to safeguard the public safety, health and general welfare through affordability, structural strength, means of egress, facilities, stability, sanitation, light and ventilation, energy conservation and safety to life and property from fire and other hazards attributed to the built environment, and to provide safety to fire fighters and first responders during emergency operations. R-R101.4 Administrative provisions. This Chapter contains those provisions that are unique to the administration of this code. All other administrative provisions applicable to this code are as set forth in the Administrative Code (Subcode A). R-R101.5 Appendices. The following appendices are adopted: 1. Sections AE501 through AE503 and AE601 through AE605 of Appendix E (“Manufactured Housing Used as Dwellings”). R-R101.6 Construction safeguards. The provisions of Chapter 33 of the International Building Code with amendments (Subcode B) shall apply to the construction safeguards required for all building construction and demolition. R-R101.7 Construction documents. In addition to the submittal requirements of the Administrative Code (Subcode A), the provisions of R-R101.7.1 and R-R101.7.2 shall apply. R-R101.7.1 Manufacturer’s installation instructions. Manufacturer’s installation instructions, as required by this code, shall be available on the job site at the time of inspection. R-R101.7.2 Information on braced wall design. For buildings and structures utilizing braced wall design, and where required by the code official, braced wall lines shall be identified on the construction documents. Pertinent information including, but not limited to, bracing methods, location and length of braced wall panels and foundation requirements of braced wall panels at top and bottom shall be provided. CHAPTER 2 DEFINITIONS * * * SECTION R202 DEFINITIONS. * * * [Add the following definition:] COOL ROOF RATING COUNCIL (or CRRC): The Cool Roof Rating Council, Inc., an American National Standards Institute-accredited standards developer organization that created, maintains, and updates the ANSI/CRRC S100 standard, entitled “Standard Test Methods for Determining Radiative Properties of Materials.” * * * CHAPTER 3 BUILDING PLANNING * * * SECTION R301 DESIGN CRITERIA * * * [Pursuant to the UCC, delete Section R301.1.4 and replace as follows:] R-R301.1.4 Intermodal shipping containers. Intermodal shipping containers that are repurposed for use as buildings or structures shall be designed in accordance with the structural provisions in Section 3115 of the International Building Code. Prior to permitting, the applicant shall have the unit certified as free from contaminants by a qualified 3rd party inspector approved by the AHJ. Any penetrations beyond those permitted in Section 3115 of the International Building Code shall be certified by a Pennsylvania Registered Design Professional. * * * [Table R301.2(1) is revised to include the climatic and geographic design criteria for Philadelphia as follows:] TABLE R-R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD | WIND SPEED d (mph) | SEISMIC DESIGN CATEGORY f | SUBJECT TO DAMAGE FROM | WINTER DESIGN TEMP e | ICE BARRIER UNDER- LAYMENT REQUIRED h | FLOOD HAZARDS g | AIR FREEZING INDEX i | MEAN ANNUAL TEMP j Weathering a | Frost line depth b | Termite c 25 psf | 115 | B | Severe | 30 in. | Moderate to heavy | 14° F | YES | (a) 1979 (b) 11/18/15 (c) see Table R-R301.2(1a) | 500 | 55.9° F [Insert Table R-R301.2(1a) as follows:] TABLE R-R301.2(1a) PANEL NUMBERS AND DATES OF EFFECTIVE FIRMs FOR PHILADELPHIA PANEL NUMBER | EFFECTIVE PANEL NUMBER | EFFECTIVE 420757IND0B | 11/18/2015 4207570019G | 01/17/2007 4207570038G | 01/17/2007 4207570067G | 01/17/2007 4207570078G | 01/17/2007 4207570086G | 01/17/2007 4207570087G | 01/17/2007 4207570088G | 01/17/2007 4207570089G | 01/17/2007 4207570104G | 01/17/2007 4207570107G | 01/17/2007 4207570108G | 01/17/2007 4207570109G | 01/17/2007 4207570111G | 01/17/2007 4207570113G | 01/17/2007 4207570114H | 11/18/2015 4207570116G | 01/17/2007 4207570117H | 11/18/2015 4207570118H | 11/18/2015 4207570119H | 11/18/2015 4207570126G | 01/17/2007 4207570127G | 01/17/2007 4207570128G | 01/17/2007 4207570129G | 01/17/2007 4207570136H | 11/18/2015 4207570157G | 01/17/2007 4207570159G | 01/17/2007 4207570167G | 01/17/2007 4207570169H | 11/18/2015 4207570177G | 01/17/2007 4207570178G | 01/17/2007 4207570179G | 01/17/2007 4207570181G | 01/17/2007 4207570182H | 11/18/2015 4207570183G | 01/17/2007 4207570184H | 11/18/2015 4207570186H | 11/18/2015 4207570187H | 11/18/2015 4207570188H | 11/18/2015 4207570189H | 11/18/2015 4207570191H | 11/18/2015 4207570192H | 11/18/2015 4207570193H | 11/18/2015 4207570194H | 11/18/2015 4207570201H | 11/18/2015 4207570202H | 11/18/2015 4207570203H | 11/18/2015 4207570206H | 11/18/2015 4207570230H | 11/18/2015 | * * * SECTION R305 CEILING HEIGHT [Pursuant to the UCC, delete Section R305.1 and replace as follows:] R-R305.1 Minimum height. Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than 7 feet (2134 mm). Bathrooms, toilet rooms and laundry rooms shall have a ceiling height of not less than 6 feet 8 inches (2032 mm). Exceptions: 1. For rooms with sloped ceilings, the required floor area of the room shall have a ceiling height of not less than 5 feet (1524 mm) and not less than 50 percent of the required floor area shall have a ceiling height of not less than 7 feet (2134 mm). 2. The ceiling height above bathroom and toilet room fixtures shall be such that the fixture is capable of being used for its intended purpose. A shower or tub equipped with a showerhead shall have a ceiling height of not less than 6 feet 8 inches (2032 mm) above an area of not less than 30 inches (762 mm) by 30 inches (762 mm) at the showerhead. 3. Beams, girders, ducts or other obstructions in basements containing habitable space shall be permitted to project to within 6 feet 4 inches (1931 mm) of the finished floor. 4. Beams and girders spaced apart a minimum of 36 inches (914 mm) in clear finished width between projections and shall have a minimum clear ceiling height of 6 feet 6 inches (1981 mm) from the finished floor directly under the beam. * * * SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS * * * [Pursuant to the UCC, delete Section R310.1 and replace as follows:] R-R310.1 Emergency escape and rescue opening required. Basements, habitable attics and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court having a minimum width of 36 inches (914 mm) that opens to a public way. Exceptions: 1. Storm shelters and basements used only to house mechanical equipment not exceeding a total floor area of 200 square feet (18.58 m2). 2. Where the dwelling unit or townhouse unit is equipped with an automatic sprinkler system installed in accordance with Section P2904, sleeping rooms in basements shall not be required to have emergency escape and rescue openings provided that the basement has one of the following: 2.1. One means of egress complying with Section R311 and one emergency escape and rescue opening. 2.2. Two means of egress complying with Section R311. 3. A yard shall not be required to open directly into a public way where the yard opens to an unobstructed path from the yard to the public way. Such path shall have a width of not less than 36 inches (914 mm). 4. Properties with in-fill lots that are sprinklered in accordance with Section 2904, and a minimum clear yard size of 80 sq ft (7.43 m2) shall be allowed to have access to the public way provided by a shared easement that is a minimum of 30 in (762 mm) wide. * * * [Delete R310.7 and replace as follows, but retain R310.7.1:] R-R310.7 Alterations or repairs of existing basements. An emergency escape and rescue opening is not required for existing basements undergoing alterations or repairs, where such alterations or repairs do not increase the existing story height of the basement. Exception: New sleeping rooms created in an existing basement shall be provided with emergency escape and rescue openings in accordance with Section R310.1. * * * SECTION R311 MEANS OF EGRESS * * * [Pursuant to the UCC, delete Section R311.7.4 and replace as follows:] R-R311.7.4 Walkline. The walkline across winder treads and landings shall be concentric to the turn and parallel to the direction of travel entering and exiting the turn. The walkline shall be located 12 inches (305 mm) from the inside of the turn. The 12-inch (305 mm) dimension shall be measured from the widest point of the clear stair width at the walking surface. Where winders are adjacent within a flight, the point of the widest clear stair width of the adjacent winders shall be used. [image] FIGURE R311.7.4 WINDER TREAD AND LANDING DETAIL * * * SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS * * * [Pursuant to the UCC, delete Section R313.2 and replace as follows:] R-R313.2 Detached one- and two-family dwellings. A builder of a one-family or two-family dwelling shall, at or before the time of entering into the purchase contract, do all of the following: 1. Offer to a buyer the option to install or equip, at the buyer’s expense, an automatic fire sprinkler system in the building or dwelling unit designed and installed in accordance with the provisions of P2904 or NFPA 13D. 2. Provide the buyer with information which explains the initial and ongoing cost of installing and equipping an automatic fire sprinkler system in the building or dwelling unit. 3. Provide the buyer with information, as made available by the State Fire Commissioner on the agency’s Internet website, on the possible benefits of installing an automatic sprinkler system. * * * SECTION R314 SMOKE ALARMS * * * [Pursuant to the UCC, delete Section R314.4 and replace as follows:] R-R314.4 Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling unit in accordance with Section R314.3, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual dwelling unit. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. Exception: Interconnection of smoke alarms in existing areas shall not be required where alterations or repairs do not result in removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available that could provide access for interconnection without the removal of interior finishes. * * * SECTION R322 FLOOD-RESISTANT CONSTRUCTION * * * [Delete Section R322.2.1 and replace as follows:] R-R322.2.1 Elevation requirements. 1. Buildings and structures in flood hazard areas shall have the lowest floors elevated to or above the base flood elevation plus 1-1/2 feet (457 mm), or the design flood elevation, whichever is higher. 2. In areas of shallow flooding (AO Zones), buildings and structures shall have the lowest floor (including basement) elevated to a height of not less than the highest adjacent grade as the depth number specified in feet (mm) on the FIRM plus 1-1/2 feet (457 mm), or not less than 3 feet (15 mm) if a depth number is not specified. 3. Basement floors that are below grade on all sides shall be elevated to or above base flood elevation plus 1-1/2 feet (457 mm), or the design flood elevation, whichever is higher. Exceptions: 1. Enclosed areas below the design flood elevation, including basements with floors that are not below grade on all sides, shall meet the requirements of Section R322.2.2. 2. Accessory structures in accordance with Section R-R322.2.1.1. R-R322.2.1.1 Accessory structures. Accessory structures are not required to be elevated to remain dry where they comply with all of the following requirements: 1. The structure shall not be designed or used for human habitation, but shall be limited to the parking of vehicles, or to the storage of tools, material, and equipment related to the principal use or activity; 2. The floor area shall not exceed 200 square feet; 3. The structure must have a low damage potential; 4. The structure must be located on the site so as to cause the least obstruction to the flow of flood waters; 5. Power lines, wiring, and outlets must be elevated to the elevation requirements of Section R-R322.2.1; 6. The structure shall not contain permanently affixed utility equipment and appliances such as furnaces, heaters, washers, dryers, etc.; 7. The structure shall not contain sanitary facilities; and 8. The structure shall be adequately anchored to prevent flotation, collapse, and lateral movement and shall be designed to automatically provide for the entry and exit of floodwater for the purpose of equalizing hydrostatic forces on the walls. Designs for meeting this requirement must either be certified by a registered design professional, or meet or exceed the following minimum criteria: a. a minimum of two openings having a net total area of not less than one (1) square inch for every square foot of enclosed space; b. the bottom of each opening shall be no more than one (1) foot above the higher of the finished interior floor or grade level and the finished exterior grade immediately under each opening; c. openings shall be installed on at least two walls of the enclosed area to allow for automatic entry and exit of floodwaters; d. openings shall not be less than 3 inches in any direction in the plane of the wall; e. openings may be equipped with screens, louvers, etc. or other coverings or devices provided that they permit the automatic entry and exit of flood waters. 9. Building materials and installation methods used for flooring and interior and exterior walls below the elevation required in R-R322.2.1 shall be flood damage-resistant materials that conform to the provisions of FEMA-TB-2. 10. A structure located in the coastal high-hazard area (including V Zones and Coastal A Zones, where designated), shall meet the requirements of Section R322.3.4 and R322.3.5. All electrical equipment and component installations to meet requirements of section R322.1.6. * * * SECTION R325 MEZZANINES * * * [Pursuant to the UCC, delete Section R325.5 and replace as follows:] R-R325.5 Openness. Mezzanines shall be open and unobstructed to the room in which they are located except for walls not more than 36 inches (914 mm) in height, columns and posts. Exception: Mezzanines or portions thereof are not required to be open to the room in which they are located, provided that the aggregate floor area of the enclosed space is not greater than 10 percent of the mezzanine area. * * * SECTION R326 HABITABLE ATTICS * * * [Pursuant to the UCC, delete Section R326.3 and replace as follows:] R-R326.3 Story above grade plane. A habitable attic shall be considered a story above grade plane. Exceptions: A habitable attic shall not be considered to be a story above grade plane provided that the habitable attic meets all the following: 1. The aggregate area of the habitable attic is either of the following: 1.1. Not greater than one-third of the floor area of the story below. 1.2. Not greater than one-half of the floor area of the story below where the habitable attic is located within a dwelling unit equipped with a fire sprinkler system in accordance with Section P2904. 2. The occupiable space is enclosed by the roof assembly above, knee walls, if applicable, on the sides and the floor-ceiling assembly below. * * * CHAPTER 5 FLOORS * * * SECTION R506 CONCRETE FLOORS (ON GROUND) * * * [Pursuant to the UCC, delete Section R506.2.3 and replace as follows:] R-R506.2.3 Vapor retarder. A minimum 6 mil (0.006 inch: 152 mm) polyethylene or approved vapor retarder with joints lapped not less than 6 inches (152 mm) shall be placed between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist. Exception: The vapor retarder is not required for the following: 1. Garages, utility buildings and other unheated accessory structures. 2. For unheated storage rooms having an area of less than 70 square feet (6.5 m2) and carports. 3. Driveways, walks, patios and other flatwork not likely to be enclosed and heated at a later date. 4. Where approved by the building official, based on local site conditions. * * * CHAPTER 6 WALL CONSTRUCTION * * * SECTION R602 WOOD WALL FRAMING. * * * [Pursuant to the UCC, delete Sections R602.10 and R.602.11 entirety and replace as follows:] R-R602.10 Wall bracing requirements. The wall bracing requirements of sections R602.10 through R602.11.3 of the 2006 International Residential Code shall apply. * * * CHAPTER 7 WALL COVERING * * * SECTION R703 EXTERIOR COVERING * * * [Pursuant to the UCC, delete Section R703.2 and replace as follows:] R-R703.2 Water-resistive barrier. Not fewer than one layer of water-resistive barrier shall be applied over studs or sheathing of all exterior walls with flashing as indicated in Section R703.4, in such a manner as to provide a continuous water-resistive barrier behind the exterior wall veneer. The water- resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. Where the water-resistive barrier also functions as a component of a continuous air barrier, the water-resistive barrier shall be installed as an air barrier in accordance with Section N1102.4.1.1. Water-resistive barrier materials shall comply with one of the following: 1. No. 15 felt complying with ASTM D226, Type 1. 2. ASTM E2568, Type 1 or 2. 3. Foam plastic insulating sheathing water-resistive barrier systems complying with Section R703.1.1 and installed in accordance with the manufacturer’s installation instructions. 4. ASTM E331 in accordance with Section R703.1.1. 5. Other approved materials in accordance with the manufacturer’s installation instructions. No.15 asphalt felt and water-resistive barriers complying with ASTM E2556 shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm), and where joints occur, shall be lapped not less than 6 inches (152 mm). Exception: A water-resistive barrier shall not be required in unconditioned detached tool sheds, playhouses, and other similar accessory structures provided all of the following requirements are met: 1. Exterior wall covering is limited to siding that is attached directly to the studs. 2. Exterior walls are uninsulated. 3. Interior side of exterior walls has no wall covering or wall finishes. * * * [Pursuant to the UCC, delete Section R703.3.1 and replace as follows:] R-R703.3.1 Exterior soffit installation. Exterior soffits shall comply with Section R704. * * * [Pursuant to the UCC, delete Section R703.4.1 and replace as follows:] R-R703.4.1 Flashing installation at exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to a water-resistive barrier complying with Section R-R703.2 for subsequent drainage. Air sealing shall be installed around all window and door openings on the interior side of the rough opening gap. Mechanically attached flexible flashings shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following: 1. The fenestration manufacturer’s installation and flashing instructions, or for applications not addressed in the fenestration manufacturer’s instructions, in accordance with the flashing or water-resistive barrier manufacturer’s instructions. Where flashing instructions or details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. 2. In accordance with the flashing design or method of a registered design professional. 3. In accordance with other approved methods. * * * [Pursuant to the UCC, delete Section R703.7 and replace as follows:] R-R703.7 Exterior plaster (stucco). Installation of exterior plaster shall be in compliance with ASTM C926-2018B, ASTM C1063-2018B and the provisions of this code. * * * SECTION R704 SOFFITS * * * [Pursuant to the UCC, delete Section R704.1 and replace as follows.] R-R704.1 General wind limitations. Where the design wind pressure is 30 pounds per square foot (1.44 kPa) or less, exterior soffits shall comply with Section R-R704.2. Where the design wind pressure exceeds 30 pounds per square foot (1.44 kPa), exterior soffits shall comply with Section R-R704.3. The design wind pressure on exterior soffits shall be determined using the component and cladding loads specified in Table R301.2.1(1) for walls using an effective wind area of 10 square feet (0.93 m2) and adjusted for height and exposure in accordance with Table R301.2.1(2). * * * [Pursuant to the UCC, delete Section R704.2 and replace as follows:] R-R704.2 Exterior soffit installation where the design wind pressure is 30 psf or less. Where the design wind pressure is 30 pounds per square foot (1.44 kPa) or less, exterior soffit installation shall comply with Section R-R704.2.1, R-R704.2.2, R-R704.2.3 or R-R704.2.4. Soffit materials not addressed in Sections R-R704.2.1 through R-R704.2.4 shall be in accordance with the manufacturer’s installation instructions. R-R704.2.1 Vinyl and aluminum soffit panels. Vinyl and aluminum soffit panels shall be installed using aluminum, galvanized, stainless steel or rust-preventative coated nails or staples or other approved corrosion-resistant fasteners specified by the manufacturer and shall be fastened at both ends to a supporting component such as a nailing strip, fascia or sub-fascia component in accordance with Figure R-R704.2.1(1). Where the unsupported span of soffit panels is greater than 16 inches (406 mm), intermediate nailing strips shall be provided in accordance with Figure R-R704.2.1(2). Vinyl and aluminum soffit panels shall be installed in accordance with the manufacturer’s installation instructions. Fascia covers shall be installed in accordance with the manufacturer’s installation instructions. FIGURE R-R704.2.1(1) TYPICAL SINGLE-SPAN VINYL AND ALUMINUM EXTERIOR SOFFIT PANEL SUPPORT [image] FIGURE R-R704.2.1(2) TYPICAL DOUBLE-SPAN VINYL AND ALUMINUM EXTERIOR SOFFIT PANEL SUPPORT [image] R-R704.2.2 Fiber-cement exterior soffit panels. Fiber-cement exterior soffit panels shall be a minimum of 1/4 inch (6.4 mm) in thickness and shall comply with the requirements of ASTM C1186, Type A, minimum Grade II, or ISO 8336, Category A, minimum Class 2. Panel joints shall occur over framing or over wood structural panel sheathing. Exterior soffit panels shall be installed with spans and fasteners in accordance with the manufacturer’s installation instructions. R-R704.2.3 Hardboard exterior soffit panels. Hardboard exterior soffit panels shall be not less than 7/16 inch (11.11 mm) in thickness and shall be fastened to framing or nailing strips with 2-1/2-inch by 0.113-inch (64 mm by 2.9 mm) siding nails spaced not more than 6 inches (152 mm) on center at panel edges and 12 inches (305 mm) on center at intermediate supports. R-R704.2.4 Wood structural panel exterior soffit. The minimum nominal thickness for wood structural panel soffits shall be 3/8-inch (9.5 mm) and shall be fastened to framing or nailing strips with 2-inch by 0.099-inch (51 mm by 2.5 mm) nails. Fasteners shall be spaced not more than 6 inches (152 mm) on center at panel edges and 12 inches (305 mm) on center at intermediate supports. [Pursuant to the UCC, delete Section R704.3 and replace as follows:] R-R704.3 Exterior soffit installation where the design wind pressure exceeds 30 psf. Where the design wind pressure is greater than 30 psf, exterior soffit installation shall comply with Section R-R704.3.1, R-R704.3.2, R-R704.3.3 or R-R704.3.4 . Exterior soffit materials not addressed in Sections R-R704.3.1 through R-R704.3.4 shall be in accordance with the manufacturer’s installation instructions. R-R704.3.1 Vinyl exterior soffit panels. Vinyl exterior soffit panels and their attachments shall be capable of resisting wind loads specified in Table R301.2.1(1) for walls using an effective wind area of 10 square feet (0.929 m2) and adjusted for height and exposure in accordance with Table R301.2.1(2). Vinyl exterior soffit panels shall be installed using fasteners specified by the manufacturer and shall be fastened at both ends to a supporting component such as a nailing strip, fascia or sub-fascia component in accordance with Figure R-R704.2.1(1). Where the unsupported span of exterior soffit panels is greater than 12 inches (305 mm), intermediate nailing strips shall be provided in accordance with Figure R-R704.2.1(2). Vinyl exterior soffit panels shall be installed in accordance with the manufacturer’s installation instructions. R-R704.3.2 Fiber-cement exterior soffit panels. Fiber-cement exterior soffit panels shall comply with Section R-R704.2.2 and shall be capable of resisting wind loads specified in Table R301.2.1(1) for walls using an effective wind area of 10 square feet (0.929 m2) and adjusted for height and exposure in accordance with Table R301.2.1(2). R-R704.3.3 Hardboard exterior soffit panels. Hardboard exterior soffit panels shall comply with the manufacturer’s installation instructions and shall be capable of resisting wind loads specified in Table R301.2.1(1) for walls using an effective wind area of 10 square feet (0.929 m2) and adjusted for height and exposure in accordance with Table R301.2.1(2). R-R704.3.4 Wood structural panel exterior soffit. Wood structural panel exterior soffits shall be capable of resisting wind loads specified in Table R301.2.1(1) for walls using an effective wind area of 10 square feet (0.929 m2) and adjusted for height and exposure in accordance with Table R301.2.1(2). Alternatively, wood structural panel exterior soffits shall be installed in accordance with Table R704.3.4. [Pursuant to the UCC, delete Footnote e of Table R704.3 and replace as follows:] e. Wood structural panels shall be attached to soffit framing members with specific gravity of at least 0.35. Where the specific gravity of the wood species used for sofit framing members is greater than or equal to 0.35 but less than 0.42 in accordance with AWC NDS, the fastener spacing shall be multiplied by 0.67 or the same fastener spacing as prescribed for galvanized steel nails shall be permitted to be used where RSRS-01 (2" × 0.099" × 0.266" head) nails replace 6d box nails and RSRS-03 (2-1/2" × 0.131" × 0.281" head) nails replace 8d common nails or 10d box nails. RSRS is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. Framing members shall be minimum 2 × 3 nominal with the larger dimension in the cross section aligning with the length of fasteners to provide sufficient embedment depths. CHAPTER 8 ROOF-CEILING CONSTRUCTION * * * SECTION R802 WOOD ROOF FRAMING [Pursuant to the UCC, delete Section R802.3 and replace as follows:] R-R802.3 Ridge. A ridge board used to connect opposing rafters shall be not less than 1 inch (25 mm) nominal thickness and not less in depth than the cut end of the rafter. Where ceiling joist or rafter ties do not provide continuous ties across the structure as required by Section R802.5.2, the ridge shall be supported by a wall or ridge beam designed in accordance with accepted engineering practice and supported on each end by a wall, or column, or girder. * * * SECTION R806 ROOF VENTILATION [Pursuant to the UCC, delete Section R806.1 and replace as follows:] R-R806.1 Ventilation required. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. Ventilation openings shall have a least dimension of 1/16 inch (1.6 mm) minimum and 1/4-inch (6.4 mm) maximum. Ventilation openings having a least dimension larger than 1/4 inch (6.4 mm) shall be provided with corrosion-resistant wire cloth screening, hardware cloth, perforated vinyl or similar material with openings having a least dimension of 1/16 inch (1.6 mm) minimum and 1/4-inch (6.4 mm) maximum. Openings in roof framing members shall conform to the requirements of Section R802.7. Required ventilation openings shall open directly to the outside air. [Pursuant to the UCC, delete Section R806.2 and replace as follows:] R-R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. Exception: The minimum net free ventilation area shall be 1/300 of the vented space provided one or more of the following conditions are met: 1. In Climate Zones 6, 7 and 8, a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling. 2. Not less than 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not more than 3 feet (914 mm) below the ridge or highest point of the space, measured vertically, with the balance of the required ventilation provided by eave or cornice vents. Where the location of wall or roof framing members conflicts with the installation of upper ventilators, installation more than 3 feet (914 mm) below the ridge or highest point of the space shall be permitted. [Pursuant to the UCC, delete Section R806.3 and replace as follows:] R-R806.3 Vent and insulation clearance. Where eave or cornice vents are installed, nothing shall not block the free flow of air. Not less than a 1-inch (25 mm) space shall be provided between the insulation and the roof sheathing and at the location of the vent. * * * CHAPTER 9 ROOF ASSEMBLIES * * * SECTION R905 REQUIREMENTS FOR ROOF COVERINGS [Add Section R-R905.18 as follows:] R-R905.18 Reflectance. Roof Coverings over conditioned spaces on low-slope roofs (roof slope < 2:12) on newly constructed buildings and additions to existing buildings shall be rated by the Cool Roof Rating Council as having: 1. a minimum three-year aged solar reflectance of 0.62 and minimum three-year aged thermal emittance of 0.75; or 2. a minimum Solar Reflectance Index of 75. Exceptions: 1. An addition to a roof that supports living vegetation and includes a synthetic, high quality waterproof membrane, drainage layer, soil layer and light weight medium plants shall be permitted to comprise part or all of the roof area. 2. Walking surfaces of occupiable rooftops. 3. An area including and adjacent to rooftop photovoltaic and solar thermal equipment, totaling not more than three times the area that is covered with such equipment. 4. Limited roof areas as determined by regulations promulgated by the Department of Licenses and Inspections. 5. A roof, the area of which is less than three (3) percent of the gross floor area of the building. 6. Any roof or portion of a roof composed of glass, metal, clay or concrete tile or plastic/rubber intended to simulate clay or concrete tile, wood, or slate. * * * CHAPTER 10 CHIMNEYS AND FIREPLACES * * * SECTION R1005 FACTORY-BUILT CHIMNEYS * * * [Pursuant to the UCC, delete Section R1005.8 and add the following:] R-R1005.8 Reserved. * * * CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS * * * SECTION M1305 APPLIANCE ACCESS * * * [Pursuant to the UCC, delete Section M1305.1.3.2 and replace as follows:] R-M1305.1.3.2 Excavations. Excavations for appliance installations shall extend to a depth of 6 inches (152 mm) below the appliance and 12 inches (305 mm) on all sides, except that the control side shall have a clearance of 30 inches (762 mm). * * * CHAPTER 14 HEATING AND COOLING EQUIPMENT AND APPLIANCES * * * SECTION M1404 REFRIGERATION COOLING EQUIPMENT [Delete Section 1404.1 and replace as follows:] R-M1404.1 Compliance. Refrigeration cooling equipment shall be listed and labeled in accordance with UL 484, UL 1995 or UL/CSA 60335-2-40. * * * SECTION M1411 HEATING AND COOLING EQUIPMENT [Delete Section M1411 and replace as follows:] R-M1411.1 Approved refrigerants. Refrigerants used in direct refrigerating systems shall conform to the applicable provisions of ANSI/ASHRAE 34. R-M1411.2 Refrigeration system listing. Refrigeration systems using Group A2L refrigerants shall be listed and labeled to Ul/CSA 60335-2-40. Refrigeration Systems using A1 refrigerants shall be listed to UL/CSA 60335-2-40 or UL 1995. The equipment shall be installed in accordance with the listing. R-M1411.3 Refrigeration system installation. Refrigeration systems shall be installed in accordance with the manufacturer’s installation instructions. After installation, the manufacturers installation instructions, owner’s manual, service manuals and any other product literature provided with equipment shall be attached to the indoor unit or left with the homeowner. R-M1411.4 Field-installed accessories. Field-installed accessories shall be installed in accordance with the accessory and equipment manufacturer’s installation instructions. Accessories installed in the ductwork of Group A2L refrigeration systems shall not contain electric heating elements, open flames, or devices switching electrical loads greater than 2.5 kVA. R-M1411.5 Signs and identification. Each refrigeration system using Group A2L refrigerant shall have the following information legibly and permanently indicated on a markable label provided by the equipment manufacturer. 1. Contact information of the company responsible that installed the refrigeration system. 2. The system refrigerant charge and the refrigerant number. R-M1411.6 Refrigerant charge. Refrigeration systems shall have refrigerant charge in compliance with the equipment manufacturer’s installation instructions and the requirements of the listing. Group A2L refrigerant charge for an individual refrigeration system shall not exceed 34.5 pounds (15.7 kg). R-M1411.7 Group A2L refrigerant piping testing. The piping system containing Group A2L refrigerant shall be tested in accordance with the manufacturer’s installation instructions and the requirements of the listing. R-M1411.8 Refrigeration coils in warm-air furnaces. Where a cooling coil is located in the supply plenum of a warm-air furnace, the furnace blower shall be rated at not less than 0.5-inch water column (124 Pa) static pressure unless the furnace is listed and labeled for use with a cooling coil. Cooling coils shall not be located upstream from heat exchangers unless listed and labeled for such use. Conversion of existing furnaces for use with cooling coils shall be permitted provided that the furnace will operate within the temperature rise specified for the furnace. R-M1411.9 Condensate disposal. Condensate from cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than 1/8 unit vertical in 12 units horizontal (1-percent slope). Condensate shall not discharge into a street, alley or other area where it would cause a nuisance. R-M1411.9.1 Auxiliary and secondary drain systems. In addition to the requirements of Section R-M1411.3, a secondary drain or auxiliary drain pan shall be required for each cooling or evaporator coil where damage to any building components will occur as a result of overflow from the equipment drain pan or stoppage in the condensate drain piping. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than 1/8 unit vertical in 12 units horizontal (1-percent slope). Drain piping shall be not less than 3/4-inch (19 mm) nominal pipe size. One of the following methods shall be used: 1. An auxiliary drain pan with a separate drain shall be installed under the coils on which condensation will occur. The auxiliary pan drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain. The pan shall have a minimum depth of 1.5 inches (38 mm), shall be not less than 3 inches (76 mm) larger than the unit or the coil dimensions in width and length and shall be constructed of corrosion-resistant material. Galvanized sheet steel pans shall have a minimum thickness of not less than 0.0236-inch (0.6010 mm) (No. 24 Gage). Nonmetallic pans shall have a minimum thickness of not less than 0.0625 inch (1.6 mm). 2. A separate overflow drain line shall be connected to the drain pan installed with the equipment. This overflow drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain. The overflow drain line shall connect to the drain pan at a higher level than the primary drain connection. 3. An auxiliary drain pan without a separate drain line shall be installed under the coils on which condensation will occur. This pan shall be equipped with a water level detection device conforming to UL 508 that will shut off the equipment served prior to overflow of the pan. The pan shall be equipped with a fitting to allow for drainage. The auxiliary drain pan shall be constructed in accordance with Item 1 of this section. 4. A water-level detection device conforming to UL 508 shall be installed that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line or the equipment-supplied drain pan, located at a point higher than the primary drain line connection and below the overflow rim of such pan. R-M1411.9.1.1 Water-level monitoring devices. On down-flow units and other coils that do not have secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. This device shall shut off the equipment served in the event that the primary drain becomes restricted. Devices shall not be installed in the drain line. R-M1411.9.1.2 Appliance, equipment and insulation in pans. Where appliances, equipment or insulation are subject to water damage when auxiliary drain pans fill, that portion of the appliance, equipment and insulation shall be installed above the rim of the pan. Supports located inside of the pan to support the appliance or equipment shall be water resistant and approved. R-M1411.9.2 Drain pipe materials and sizes. Components of the condensate disposal system shall be ABS, cast iron, copper, cross-linked polyethylene, CPVC, galvanized steel, PE-RT, polyethylene, polypropylene or PVC pipe or tubing. Components shall be selected for the pressure and temperature rating of the installation. Joints and connections shall be made in accordance with the applicable provisions of Chapter 30. Condensate waste and drain line size shall be not less than 3/4-inch (19 mm) nominal diameter from the drain pan connection to the place of condensate disposal. Where the drain pipes from more than one unit are manifolded together for condensate drainage, the pipe or tubing shall be sized in accordance with an approved method. R-M1411.9.3 Drain line maintenance. Condensate drain lines shall be configured to permit the clearing of blockages and performance of maintenance without requiring the drain line to be cut. R-M1411.9.4 Appliances, equipment and insulation in pans. Where appliances, equipment or insulation are subject to water damage when auxiliary drain pans fill, those portions of the appliances, equipment and insulation shall be installed above the flood level rim of the pan. Supports located inside of the pan to support the appliance or equipment shall be water resistant and approved. R-M1411.10 Condensate pumps. Condensate pumps located in uninhabitable spaces, such as attics and crawl spaces, shall be connected to the appliance or equipment served such that when the pump fails, the appliance or equipment will be prevented from operating. Pumps shall be installed in accordance with the manufacturer’s instructions. R-M1411.11 Auxiliary drain pan. Category IV condensing appliances shall have an auxiliary drain pan where damage to any building component will occur as a result of stoppage in the condensate drainage system. These pans shall be installed in accordance with the applicable provisions of Section R-M1411.3. Exception: Fuel-fired appliances that automatically shut down operation in the event of a stoppage in the condensate drainage system. R-M1411.12 Insulation of refrigerant piping. Piping and fittings for refrigerant vapor (suction) lines shall be insulated with insulation having a thermal resistivity of not less than R-3 and having external surface permeance not exceeding 0.05 perm [2.87 ng/(s × m2 × Pa)] when tested in accordance with ASTM E96. R-M1411.12.1 Refrigerant line insulation protection. Refrigerant piping insulation shall be protected in accordance with Section N1103.4.1. R-M1411.13 Location and protection of refrigerant piping. Refrigerant piping installed within 1-1/2 inches (38 mm) of the underside of roof decks shall be protected from damage caused by nails and other fasteners. R-M1411.14 Support of refrigerant piping. Refrigerant piping and tubing shall be securely fastened to a permanent support within 6 feet (1829 mm) of the condensing unit. R-M1411.15 Locking access port caps. Refrigerant circuit access ports located outdoors shall be fitted with locking-type tamper-resistant caps or shall be otherwise secured to prevent unauthorized access. * * * SECTION M1412 ABSORBTION COOLING EQUIPMENT [Delete Section 1412.1 and replace as follows:] R-M1412.1 Listed equipment. Absorption Systems shall be installed in accordance with the manufacturer’s instructions. Absorption equipment shall be listed and labeled in accordance with UL 1995 or UL/CSA/ANCE 60335-2-40 * * * CHAPTER 15 EXHAUST SYSTEMS * * * SECTION M1502 CLOTHES DRYER EXHAUST * * * [Pursuant to the UCC, delete Section M1502.3.1] * * * CHAPTER 20 BOILERS AND WATER HEATERS SECTION M2001 BOILERS * * * [Pursuant to the UCC, add Section R-M2001.1.2 as follows:] R-M2001.1.2 Coal-fired boilers. Coal-fired boilers shall not be subject to the stamping (labeling) requirements of Section M2001.1.1. * * * SECTION M2006 POOL HEATERS [Delete Section 2006.1 and replace as follows:] R-M2006.1 General. Pool and spa heater shall be installed in accordance with the manufacturer’s installation instructions. Oil-fired pool heaters shall be listed and labeled in accordance with UL 726. Electric pool and spa heaters shall be listed and labeled in accordance with UL 1261. Pool and spa heat pump water heaters shall be listed and labeled in accordance with UL1995 or UL/CSA/ANCE 60335-2-40. * * * CHAPTER 24 FUEL GAS * * * SECTION G2427 (503) VENTING OF APPLIANCES * * * [Pursuant to the UCC, delete Section G2427.2.2 and replace as follows:] R-G2427.2.2 (503.2.4) Appliances with integral vents. Appliances incorporating integral venting means shall be installed in accordance with Section G2427.8. * * * [Pursuant to the UCC, delete Section G2427.5.1 and replace as follows:] R-G2427.5.1 (503.5.1) Factory-built chimneys. Factory-built chimneys shall be listed in accordance with UL 103 and installed in accordance with manufacturer’s instructions. Factory-built chimneys used to vent appliances that operate at a positive vent pressure shall be listed for such application. * * * [Pursuant to the UCC, delete Section G2427.5.4 and replace as follows:] R-G2427.5.4 (503.5.5) Size of chimneys. The effective area of a chimney venting system serving listed appliances with draft hoods, Category I appliances, and other appliances listed for use with Type B vents shall be determined in accordance with one of the following methods: 1. The provisions of Section G2428. 2. The effective areas of the vent connector and chimney flue of a venting system serving a single appliance with a draft hood shall be not less than the area of the appliance flue collar or draft hood outlet, nor greater than seven times the draft hood outlet area. 3. The effective area of a chimney flue or a venting system serving two appliances with draft hoods, shall be not less than the area of the larger draft hood outlet plus 50 percent of the area of the smaller draft hood outlet. Nor greater than seven times the smallest draft hood outlet. 4. Chimney venting systems using mechanical draft shall be sized in accordance with approved engineering methods. 5. Other approved engineering methods. * * * [Pursuant to the UCC, delete Section G2427.5.10 and replace as follows:] R-G2427.5.10 (503.5.11) Insulation shield. Where a factory-built chimney passes through insulated assemblies, an insulation shield constructed of steel having a thickness of not less than 0.0187 inch (0.475 mm) (nominal 26 gage) shall be installed to provide clearance between the chimney and the insulation material. The clearance shall be not less than the clearance to combustibles specified by the chimney manufacturer’s installation instructions. Where chimneys pass through attic space, the shield shall terminate not less than 2 inches (51 mm) above the installation materials and shall be secured in place to prevent displacement. Insulation shields provided as part of a listed chimney system shall be installed in accordance with the manufacturer’s installation instructions. * * * CHAPTER 36 SERVICES (ELECTRICAL) * * * SECTION E3601 GENERAL SERVICES * * * [Pursuant to the UCC, delete Section E3601.8 and replace as follows:] R-E3601.8 Emergency disconnects. For one- and two-family detached dwelling units, all service conductors shall terminate in disconnecting means having a short-circuit current rating equal to or greater than the available fault current, installed in a readily accessible outdoor location. If more than one disconnect is provided, they shall be grouped. Each disconnect shall be one of the following: 1. Service disconnects marked as follows: EMERGENCY DISCONNECT, SERVICE DISCONNECT. 2. Meter disconnect switches that have a short-circuit current rating equal to or greater than the available fault current and all metal housings and service enclosures are grounded in accordance with Section E3908.7 and bonded in accordance with Section 3609. A meter disconnect switch shall be capable of interrupting the load served and shall be marked as follows: EMERGENCY DISCONNECT, METER DISCONNECT, NOT SERVICE EQUIPMENT. 3. Other listed disconnect switches or circuit breakers on the supply side of each service disconnect that are suitable for use as service equipment and marked as follows: EMERGENCY DISCONNECT, NOT SERVICE EQUIPMENT. Markings shall comply with Section E3404.12. [230.82 (3), 230.85] * * * CHAPTER 39 POWER AND LIGHTING DISTRIBUTION SECTION E3901 RECEPTACLE OUTLETS * * * [Pursuant to the UCC, delete Section E3901.4.2 and replace as follows:] R-E3901.4.2 Island countertop spaces. At least one receptacle outlet shall be installed at each island countertop space with a long dimension of 24 inches (610 mm) or greater and a short dimension of 12 inches (305 mm) or greater. [210.52(C)(2)] R-E3901.4.2.1 Peninsular countertop space. Not less than one receptacle outlet shall be installed at each peninsular countertop long dimension space having a long dimension of 24-inches (610 mm) or greater and a short dimension of 12 inches (305 mm) or greater. A peninsular countertop is measured from the connected perpendicular wall. [210.52(C)(3)] * * * [Pursuant to the UCC, delete Section E3901.11 and replace as follows:] R-E3901.11 Foyers. Foyers that are not part of a hallway in accordance with Section E3901.10 and that have an area that is greater than 60 ft2 (5.57 m2) shall have a receptacle(s) located in each wall space that is 6 feet (1829 mm) or more in width, but a minimum of one receptacle. Doorways, door-side windows that extend to the floor, and similar openings shall not be considered as wall space. [210.52(H)] * * * SECTION E3905 BOXES, CONDUIT BODIES AND FITTINGS * * * [Pursuant to the UCC, delete Section E3905.8 and replace as follows:] R-E3905.8 Boxes at fan outlets. Outlet boxes and outlet box systems used as the sole support of ceiling- suspended fans (paddle) shall be marked by their manufacturer as suitable for this purpose and shall not support ceiling-suspended fans (paddle) that weigh more than 70 pounds (31.8 kg). For outlet boxes and outlet box systems designed to support ceiling-suspended fans (paddle) that weigh more than 35 pounds (15.9 kg), the required marking shall include the maximum weight to be supported. Outlet boxes mounted in the ceilings of habitable rooms for the installation of a ceiling-suspended (paddle) fan shall comply with one of the following: 1. Listed for sole support of ceiling-suspended (paddle) fans. 2. An outlet box complying with the applicable requirements of Section E3905.6 and providing access to structural framing capable of supporting of a ceiling suspended (paddle) fan bracket or equipment. [314.27(C)] * * * CHAPTER 40 DEVICES AND LUMINARES * * * SECTION E4002 RECEPTACLES * * * [Pursuant to the UCC, delete Section E4002.11and replace as follows:] R-E4002.11 Bathtub and shower space. A receptacle shall not be installed within or directly over a bathtub or shower stall. [406.9(C)] * * * SECTION E4004 LUMINAIRE INSTALLATION * * * [Pursuant to the UCC, delete Section E4004.5 and replace as follows:] R-E4004.5 Means of support. Luminaires shall be permitted to be supported by outlet boxes or fittings installed as required by Sections E3905, and E3906. Outlet boxes complying with Section E3905.6.3 shall be considered lighting outlets as required by Section E3903. [410.36(A)] * * * CHAPTER 44 REFERENCED STANDARDS * * * [Delete ASHRAE and replace as follows:] ASHRAE A ASHRAE 34 2022 * * * [Delete UL and replace as follows:] UL UL/CSA 60335-2-40—2022 * * *