SECTION R326 HABITABLE ATTICS


SECTION R326 HABITABLE ATTICS

* * *

[Pursuant to the UCC, delete Section R326.3 and replace as follows:]

R-R326.3 Story above grade plane. A habitable attic shall be considered a story above grade plane.

Exceptions: A habitable attic shall not be considered to be a story above grade plane provided that the habitable attic meets all the following:

1. The aggregate area of the habitable attic is either of the following:

1.1. Not greater than one-third of the floor area of the story below.

1.2. Not greater than one-half of the floor area of the story below where the habitable attic is located within a dwelling unit equipped with a fire sprinkler system in accordance with Section P2904.

2. The occupiable space is enclosed by the roof assembly above, knee walls, if applicable, on the sides and the floor-ceiling assembly below.

* * *