R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE


R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE

* * *

[Pursuant to the UCC, delete Section R406.3 (N1106.3) and replace with ‘Reserved’.]

* * *

[Pursuant to the UCC, delete Section R-406.4 and replace as follows:]

EC-R406.4 (N1106.4) Energy rating index. The Energy Rating Index (ERI) shall be a numerical integer value that is based on a linear scale constructed such that the ERI reference design has an Index value of 100 and a residential building that uses no net purchased energy has an Index value of 0. Each integer value on the scale shall represent a 1 percent change in the total energy use of the rated design relative to the total energy use of the ERI reference design. The ERI shall consider all energy used in the residential building.

EC-R406.4.1 (N1106.4.1) ERI reference design. The ERI reference design shall be configured such that it meets the minimum requirements of the 2006 International Energy Conservation Code prescriptive requirements. The proposed residential building shall be shown to have an annual total normalized modified load less than or equal to the annual total loads of the ERI reference design.

* * *

[Pursuant to the UCC, delete Section R406.7.1 and replace as follows:]

EC-R406.7.1 (N1106.7.1) Compliance software tools. Documentation verifying that the methods and accuracy of the compliance software tools conform to the provisions of this section shall be provided to the code official.

* * *

[Pursuant to the UCC, delete Section R406.7.2 and replace as follows:]

EC-R406.7.2 (N1106.7.2) Compliance report. Compliance software tools shall generate a report that documents that the home and the ERI score of the rated design complies with Sections R406.2, R406.3 and R406.4. Compliance documentation shall be created for the proposed design and shall be submitted with the application for the building permit. Confirmed compliance documents of the built dwelling shall be created and submitted to the code official for review before a certificate is issued. Compliance reports shall include information in accordance with Sections R406.7.2.1 and R406.7.2.2.

EC-R406.7.2.1 (N1106.7.2.1) Proposed compliance report for permit application. Compliance reports submitted with the application for a building permit shall include the following:

1. Building Street address or other building site identification.

2. Declare ERI on title page and building plans.

3. The name of the individual performing the analysis and generating the compliance report.

4. The name and version of the compliance software tool.

5. Documentation of all inputs entered into the software used to produce the results for the reference design and/or the rated home.

6. A certificate indicating that the proposed design has an ERI less than or equal to the appropriate score indicated in Table R406.5 when compared to the ERI reference design. The certificate shall document the building component energy specifications that are included in the calculation, including: component level insulation R-values or U-factors; assumed duct and building envelope air leakage testing results; and the type and rated efficiencies of proposed heating, cooling, mechanical ventilation, and service water-hating equipment to be installed. If on-site renewable energy systems will be installed, the certificate shall report the type and production size of the proposed system.

7. When a site-specific report is not generated, the proposed design shall be based on the worst-case orientation and configuration of the rated home.

R406.7.2.2 (N1106.7.2.2) Confirmed compliance report for a certificate of occupancy. A confirmed compliance report submitted for obtaining the certificate of occupancy shall be made site and address specific and include the following:

1. Building street address or other building site identification.

2. Declaration of ERI on title page and on building plans.

3. The name of the individual performing the analysis and generating the compliance report.

4. The name and version of the compliance software tool.

5. Documentation of all inputs entered into the software used to produce the results for the reference design and/or the rated home.

6. A final confirmed certificate indicating that the confirmed rated design of the built home complies with Sections R406.2 (N1106.2) and R406.4 (N1106.4). The certificate shall report the energy features that were confirmed to be in the home, including: component-level insulation R-values or U-factors; results from any required duct system and building envelope air leakage testing; and the type and rated efficiencies of the heating cooling, mechanical ventilation, and service water- heating equipment installed. Where on-site renewable energy systems have been installed on or in the home, the certificate shall report the type and production size of the installed home.

* * *

[Pursuant to the UCC, delete Section R406.7.5 and R406.7.6:]

* * *

[Pursuant to the UCC, add Section R406.8 as follows:]

EC-R406.8 (N1106.8) Calculation software tools. Calculation software, where used, shall be in accordance with Sections R406.8.1 (N1106.8.1) through R406.8.3 (N1106.8.3).

EC-R406.8.1 (N1106.8.1) Minimum capabilities. Calculation procedures used to comply with this section shall be software tools capable of calculating the ERI as described in Section R406.4 (N1106.4), and shall include the following capabilities:

1. Computer generation of the ERI reference design using only the input for the rated design. The calculation shall not allow the user to directly modify the building component characteristics of the ERI reference design.

2. Calculation of the whole-building, as a single zone, sizing for the heating and cooling equipment in the ERI reference design residence in accordance with Section R403.7 (N1103.7).

3. Calculations that account for the effects of indoor and outdoor temperatures and part-load ratios on the performance of heating, ventilation, and air-conditioning equipment based on climate and equipment sizing.

4. Printed code official inspection checklist listing each of the rated design component characteristics determined by the analysis to provide compliance, along with their respective performance ratings.

EC-R406.8.2 (N1106.8.2) Specific Approval. Performance analysis tools meeting the applicable sections of Section R406 (N1106) shall be approved. Tools are permitted to be approved based on meeting a specified threshold for a jurisdiction. The code official shall approve tools for a specified application or limited scope.

EC-R406.8.3 (N1106.8.3) Input values. Where calculations require input values not specified by Section R402 (N1102), R403 (N1103), R404 (N1104), and R405 (N1105), those input values shall be taken from an approved source.

* * *